916 resultados para electrical conductivity in orchards
Resumo:
Some results of investigations of the connection of the parameters of thunderstorm activity with the air electrical conductivity are represented.
Resumo:
In order to assess the influence of the colostrum period on pH and, electrical conductivity, we collected 418 milk samples from 127 Jersey cows. The samples were collected from healthy udders that did not present any bacterial growth in the microbiological examination. They were divided into eight groups as follows < 1/2 day; 1/2 and 1 degrees day; 2 degrees day; 3 degrees day; 4 degrees and 5 degrees day; 6 degrees and 7 degrees day; 8 degrees to 15 degrees day; 16 degrees to 30 degrees days of lactation. The samples were collected before milking and the following analyses were conducted: pH, electrical conductivity. In the first 24 hours of lactation, there was an reduction in electrical conductivity value, associated with an increase in pH value. We observed that transition of secretion from colostrum to milk, occurs during the first week of lactation; from 6(rd) day of lactation for pH value and 3(th) day for electrical conductivity value. We recommend the use the following figures as normal ranges for the first 24 hours of lactation (colostrum period): pH <= 6,51 and electrical conductivity <= 6,33 mS/cm; while for the interval between 2(nd) and 7(th) days of lactation (transition from colostrum to milk) we suggest the use of the values as normal ranges: pH <= 6,66 and electrical conductivity <= 5,93 mS/cm.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the work was to study the effect of milking fraction on electrical conductivity of milk (EC) to improve its use in dairy goat mastitis detection using automatic EC measurements during milking. The experiment was carried out on a group of 84 Murciano-Granadina goats (28 primiparous and 56 multiparous). Goats were in the fourth month of lactation. A linear mixed model was used to analyse the relationship between EC or somatic cell count (SCC) of gland milk and parity, mammary gland health status, analysed fraction (first 100 mL=F-1; machine milk=F-2; and stripping milk=F-3) and their first order interactions. Additionally, the mastitis detection characteristics (sensitivity, specificity, positive predictive value and negative predictive value) of SCC and EC were studied at different thresholds.All factors considered were significant for EC and SCC. EC decreased significantly as milking progressed (from F-1 to F-3) in both healthy and infected glands. EC was not significantly different between healthy and infected glands in F-1 and F-2 fractions, but EC of healthy glands (5.01 mS/cm) was significantly lower than in infected glands (5.03 mS/cm) at F-3.Mastitis detection characteristics of EC did not differ amongst studied fractions. The small significant difference of EC between healthy and infected glands obtained in F-3 fraction did not yield better sensitivity results compared to F-1 and F-2. The best EC mastitis detection characteristics were obtained at 5.20 mS/cm threshold (sensitivity of 70% and specificity of 50%). The best SCC mastitis detection characteristics were obtained at 300,000 cells/mL threshold and F-3 fraction (sensitivity of 85% and specificity of 65%).It was concluded that mastitis detection characteristics of EC were similar in the three milking fractions analysed, being slightly better for SCC in F-3 fraction. As shown in previous studies, there are no factors other than the mammary gland health status that affect milk EC and should be considered in the algorithms for mastitis detection to improve the results. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Plasticized natural macromolecules-based polymer electrolyte samples were prepared and characterized. The plasticization of chitosonium acetate with glycerol increased the ionic conductivity value from 3.0 x 10(-7) S/cm to 1.1 x 10(-5) S/cm. The conductivity temperature relationship of the samples exhibits either VTF or Arrhenius type depending on the glycerol concentration in the sample. The dielectric studies evidencing the relaxation process in the plasticized sample at low frequency region are due to the electric polarization effect. Moreover, the samples were transparent in the Vis region, showed thermal stability up to 160 degrees C and good surface uniformity.
Resumo:
ABSTRACT Precision agriculture adoption in Brazilian apple orchards is still incipient. This study aimed at evaluating the spatial variability of certain soil properties as soil density, soil penetration resistance, electrical conductivity, yield, and fruit quality in an apple orchard through digital mapping, as well as assessing the correlation between these factors by means of geostatistics, establishing management zones. Forty representative points were set within 2.5 hectares of apple orchard, wherein soil samples were collected and analyzed, besides measurements of fruit quality (Brix degree, size or diameter, pulp firmness and color) to generate an overall index quality. We concluded that the fruit quality indexes, when isolated, did not show strong spatial dependence, unlike the index of fruit quality (FQI), derived from a combination of these parameters, allowing orchard planning according to management zones based on quality.
Resumo:
Four dispersion methods were used for the preparation of vapour grown carbon nanofibre (VGCNF)/epoxy composites. It is shown that each method induces certain levels of VGCNF dispersion and distribution within the matrix, and that these have a strong influence on the composite electrical properties. A homogenous VGCNF dispersion does not necessarily imply higher electrical conductivity. In fact, it is concluded that the presence of well distributed clusters, rather than a fine dispersion, is more important for achieving larger conductivities for a given VGCNF concentration. It is also found that the conductivity can be described by a weak disorder regime.
Resumo:
In this work it is demonstrated that the capacitance between two cylinders increases with the rotation angle and it has a fundamental influence on the composite dielectric constant. The dielectric constant is lower for nematic materials than for isotropic ones and this can be attributed to the effect of the filler alignment in the capacitance. The effect of aspect ratio in the conductivity is also studied in this work. Finally, based on previous work and by comparing to results from the literature it is found that the electrical conductivity in this type of composites is due to hopping between nearest fillers resulting in a weak disorder regime that is similar to the single junction expression.
Hydraulic conductivity in response to exchangeable sodium percentage and solution salt concentration
Resumo:
Hydraulic conductivity is determined in laboratory assays to estimate the flow of water in saturated soils. However, the results of this analysis, when using distilled or deionized water, may not correspond to field conditions in soils with high concentrations of soluble salts. This study therefore set out to determine the hydraulic conductivity in laboratory conditions using solutions of different electrical conductivities in six soils representative of the State of Pernambuco, with the exchangeable sodium percentage adjusted in the range of 5-30%. The results showed an increase in hydraulic conductivity with both decreasing exchangeable sodium percentage and increasing electrical conductivity in the solution. The response to the treatments was more pronounced in soils with higher proportion of more active clays. Determination of hydraulic conductivity in laboratory is routinely performed with deionized or distilled water. However, in salt affected soils, these determinations should be carried out using solutions of electrical conductivity different from 0 dS m-1, with values close to those determined in the saturation extracts.
Resumo:
The effect of controlled In3+ substitution on to the B-site in the perovskite oxygen ion conductor La0.9Sr0.1Ga0.8Mg0.2O2.85 (LSGM) has been examined with a view to exploring the influence on oxygen ion conductivity. In combination with the electrical conductivity study, detailed microstructural analysis was used to verify the location of the substituting cation and to determine the nature of secondary phase formation. The indium species clearly substituted for Ga3+ on the B-site of the lattice and the electrical conductivity showed a gradual decrease as the In+3 content increased. The interpretation of this data was complicated by the formation of the secondary phases LaInO3 and LaSrGaO4. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Electrical conductivity versus dopant ionic radius studies in zirconia- and ceria-based, solid oxide fuel cell (SOFC) electrolyte systems have shown that oxygen-ion conductivity is highest when the host and dopant ions are similar in size [J. Am. Ceram. Soc. 48 (1965) 286; Solid State Ionics 37 (1989) 67; Solid State Ionics 5 (1981) 547]. Under these conditions, it is thought that the conduction paths within the crystal lattice become less distorted [Solid State Ionics 8 (1983) 201]. In this study, binary ZrO2-M2O3 unit cells were expanded, via the partial substitution of Ce+4 for Zr+4 into the lattice, in an attempt to identify new, ternary, zirconia/ceria-based electrolyte systems with enhanced electrical conductivity. The compositions Zr0.75Ce0.08M0.17O1.92 (M = Nd, Sm, Gd, Dy, Ho, Y, Yb, Sc) were prepared using traditional solid state techniques. Bulk phase characterisation and precise lattice parameter measurements were performed with X-ray diffraction techniques. Four-probe DC conductivity measurements between 400 and 900 degreesC showed that the dopant-ion radius influenced electrical conductivity. The conductivity versus dopant-ion radius trends previously observed in zirconia-based, binary systems are clearly apparent in the ternary systems investigated in this study. The addition of ceria was found to have a negative influence on the electrical conductivity over the temperature range 400-900 degreesC. It is suggested that distortion of the oxygen-ion conduction path by the presence of the larger M+3 and Ce+4 species (relative to Zr+4) is the reason for the decreasing electrical conductivity as a function of increasing dopant size and ceria addition, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Tiivistelmä: Turvekasvualustan sähkönjohtavuuden ja vesipitoisuuden riippuvuus mitattuna TDR-käsimittarilla
Resumo:
ABSTRACT Soil solution samplers may have the same working principle, but they differ in relation to chemical and physical characteristics, cost and handling, and these aspects exert influence on the chemical composition of the soil solution obtained. This study was carried out to evaluate, over time, the chemical composition of solutions extracted by Suolo Acqua, with the hydrophilic membrane (HM) as a standard, using soils with contrasting characteristics, and to determine the relationship between electrical conductivity (EC) and concentration of ions and pH of soil solution samples. This study was carried out under laboratory conditions, using three soils samples with different clay and organic matter (OM) contents. Soil solution contents of F−, Cl−, NO−3, Br−, SO42−, Na+, NH4+, K+, Mg2+, Ca2+, were analyzed, as well as inorganic, organic, and total C contents, pH, and EC, in four successive sampling times. Soil solution chemical composition extracted by the Suolo Acqua sampler is similar to that collected by the HM, but the Suolo Acqua extracted more Na+ and soluble organic C than the HM solution. Solution EC, cation and anion concentrations, and soluble C levels are higher in the soil with greater clay and OM contents (Latossolo and Cambissolo in this case). Soil solution composition varied over time, with considerable changes in pH, EC, and nutrient concentrations, especially associated with soil OM. Thus, single and isolated sampling of the soil solution must be avoided, otherwise composition of the soil solution may not be correctly evaluated. Soil solution EC was regulated by pH, as well as the sum of cation and anion concentrations, and the C contents determined in the soil liquid phase.
Resumo:
Precision agriculture based on the physical and chemical properties of soil requires dense sampling to determine the spatial variability of these properties. This dense sampling is often expensive and time-consuming. One technique used to reduce sample numbers involves defining management zones based on information collected in the field. Some researchers have demonstrated the importance of soil electrical variables in defining management zones. The objective of this study was to evaluate the relationship between the spatial variability of the apparent electrical conductivity and the soil properties in the coffee production of mountain regions. Spatial variability maps were generated using a geostatistical method. Based on the spatial variability results, a correlation analysis, using bivariate Moran's index, was done to evaluate the relationship between the apparent electrical conductivity and soil properties. The maps of potassium (K) and remaining phosphorus (P-rem) were the closest to the spatial variability pattern of the apparent electrical conductivity.
Resumo:
Four distinct peaks are observed at 140, -26, -132 and -140°C in the sigma x* against T-1 plot between 200 and - 196°C for (NH4)3H(SO4)2, corresponding to four different phase transitions of which the one at -26°C is reported here for the first time. Data on doped samples reveal the charge transport mechanism in the crystal.