970 resultados para edentulous ridge expansion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the healing and bony crest resorption at implants installed conventionally or applying an edentulous ridge expansion (ERE) technique in the maxilla.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted bilaterally. In the left side of the maxilla (Test), the flaps were elevated and the buccal plate of the alveoli and septa was removed. After 3 months of healing, partial-thickness (split) flaps were dissected and the residual alveolar bone was exposed. In the right side of the maxilla, an implant was installed conventionally (Type IV; Control) while, in the left side, the ERE technique was adopted. Hence, an expansion of the buccal bony crest was obtained, and the implant was subsequently installed (Test). After 3 months of healing, biopsies were obtained and ground sections were prepared for histological analyses.Results: A buccal vertical resorption of the bony crest of 2.2 +/- 1.2 mm and 1.6 +/- 0.7 mm was found at the test and control sites, respectively. The difference, however, did not reach statistical significance. The coronal level of osseointegration at the buccal aspect was located at 3.1 +/- 1.0 mm and 2.2 +/- 0.7 mm from the implant shoulder at the test and control sites, respectively, the difference being statistically significant. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 43% to 48% at the buccal and lingual sites. No differences reached statistical significance.Conclusions: Implants installed by applying an ERE technique may osseointegrate similarly to conventional implant installation. However, vertical and horizontal resorption of the displaced buccal bony wall occurred as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the hard tissue changes at implants installed applying edentulous ridge expansion (E.R.E.) at sites with a buccal bony wall thickness of 1 or 2 mm.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted, and the buccal alveolar bony plates and septa were removed. After 3 months of healing, partial-thickness flaps were dissected, and the E.R.E. was applied bilaterally. Hence, an expansion of the buccal bony crest was obtained in both sides of the maxilla with a displacement of either a 1- or a 2-mm-wide buccal bony plate at the test and control sites, respectively. After 3 months of healing, biopsies were obtained for histological analyses.Results: A buccal vertical resorption of the alveolar crest of 2.3 +/- 0.8 and 2.1 +/- 1.1 mm, and a coronal level of osseointegration at the buccal aspect of 2.7 +/- 0.5 and 2.9 +/- 0.9 mm were found at the test (1 mm) and control (2 mm) sites, respectively. The differences did not reach statistical significance. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 62% to 73% at the buccal and lingual sites. No statistically significant differences were found. Horizontal volume gains of 1.8 and 1.1 mm were observed at the test and control sites, respectively, and the difference being statistically significant.Conclusions: Implants installed using the E.R.E. technique yielded a high degree of osseointegration. It is suggested that the displacement of buccal bony plates of 1 mm thickness is preferable compared with that of wider dimensions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To describe the adaptation of the Edentulous Ridge Expansion (E.R.E.) technique for implant removal. Material and Methods: The E.R.E. technique for the removal of failed implants is described in detail. A clinical case is also reported. In a patient carrying a full arch removable prosthesis in the upper jaw, sustained by two bars, two out of five implants were found to be fractured. Bucco-lingual partial-thickness flaps were used to access the fractured implants. The implants were subsequently removed applying the E.R.E. technique. Two recipient sites were prepared in the same position, using bone expanders, and two new implants were installed. Results: After 4 months of healing, the implants were integrated and a new bar was fabricated, and the old prosthesis readapted. Conclusion: The ERE technique may be successfully applied for the removal of failed implants, and the immediate or delayed reinstallation of new implants. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the suitability of a minipig model for the study of bone healing and osseointegration of dental implants following bone splitting and expansion of narrow ridges. MATERIAL AND METHODS In four minipigs, the mandibular premolars and first molars were extracted together with removal of the buccal bone plate. Three months later, ridge splitting and expansion was performed with simultaneous placement of three titanium implants per quadrant. On one side of the mandible, the expanded bone gap between the implants was filled with an alloplastic biphasic calcium phosphate (BCP) material, while the gap on the other side was left unfilled. A barrier membrane was placed in half of the quadrants. After a healing period of 6 weeks, the animals were sacrificed for histological evaluation. RESULTS In all groups, no bone fractures occurred, no implants were lost, all 24 implants were osseointegrated, and the gap created by bone splitting was filled with new bone, irrespective of whether BCP or a barrier membrane was used. Slight exposure of five implants was observed, but did not lead to implant loss. The level of the most coronal bone-to-implant contact varied without being dependent on the use of BCP or a barrier membrane. In all groups, the BCP particles were not present deep in the bone-filled gap. However, BCP particles were seen at the crestal bone margin, where they were partly integrated in the new bone. CONCLUSIONS This new minipig model holds great promise for studying experimental ridge splitting/expansion. However, efforts must be undertaken to reduce implant exposure and buccal bone resorption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of the periosteum in preserving the buccal bone after ridge splitting and expansion with simultaneous implant placement. MATERIAL AND METHODS In 12 miniature pigs, the mandibular premolars and first molars were removed together with the interdental bone septa and the buccal bone. Three months later, ridge splitting and expansion of the buccal plate was performed with simultaneous placement of two titanium implants per quadrant. Access by a mucosal flap (MF) was prepared on test sides, while a mucoperiosteal flap (MPF) with complete denudation of the buccal bone was increased on control sides. After healing periods of six and 12 weeks, the animals were sacrificed for histologic and histometric evaluation. RESULTS In the MF group, all 16 implants were osseointegrated, while in the MPF group, four of 16 implants were lost. Noticeable differences of bone levels on the implant surface and of the bone crest (BC) were found between the MF and the MPF group. Buccally after 6 weeks, the median distance between the implant shoulder (IS) and the coronal-most bone on the implant (cBIC) was for the MF group -1.42 ± 0.42 mm and for the MPF group -4.80 ± 2.72 mm (P = 0.15). The median distance between the IS and the buccal BC was -1.24 ± 0.51 mm and -2.78 ± 1.98 mm (P = 0.12) for the MF and MPF group, respectively. After 12 weeks, median IS-cBIC was -2.12 ± 0.84 mm for MF and -7.19 mm for MPF, while IS-BC was -2.08 ± 0.79 mm for MF and -5.96 mm for MPF. After 6 weeks, the median buccal bone thickness for MF and MPF was 0.01 and 0 mm (P < 0.001) at IS, 1.48 ± 0.97 mm and 0 ± 0.77 mm (P = 0.07) at 2 mm apical to IS, and 2.12 ± 1.19 mm and 1.72 ± 01.50 mm (P = 0.86) at 4 mm apical to IS, respectively. After 12 weeks, buccal bone thickness in the MF group was 0 mm at IS, 0.21 mm at 2 mm apical to IS, and 2.56 mm at 4 mm apical to IS, whereas complete loss of buccal bone was measured from IS to 4 mm apical to IS for the MPF group. CONCLUSIONS In this ridge expansion model in miniature pigs, buccal bone volume was significantly better preserved when the periosteum remained attached to the bone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to observe the clinical outcome of bone spreading and standardized dilation of horizontally resorbed bone during immediate implant placement using a "screw-type" configuration of expansion and threadformers. Fifty-three patients were included in this study, and 41 edentulous areas in anterior and posterior maxillas were treated. Sixty-eight implants were placed using an insertion torque of at least 40 Ncm. Abutments were delivered 4 to 6 months after implant placement. The overall failure percentage was 4.41% (3 failures). A retrieved analysis of I implant removed at 3 years after placement demonstrated bone resorption down to the level of the third thread. The bone spreader technique is different from Summers' osteotome, both in clinical use and in armamentarium. The main advantage of the crest-expanding technique is that it is a less invasive procedure; the facial wall expands after the medullary bone is compressed against the cortical wall. Within the limits of this preliminary study, the cumulative survival rate for this method of implant placement is 95.58% at 3 years. This study confirms that a bone spreader used in the maxilla shows an unusually low failure rate after 3 years.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The uses of a new bone spreading technique with simultaneous implant placement are discussed. The spreading system is an alternative technique to Summers' osteotome. Specific screw designs (spreader) served to laterally compress the bone to increase the cancellous density adjacent to the site. The spreader achieved a controlled and standardized dilation of horizontal bone. The advantages, material selection, and the application of this new procedure are detailed. (Implant Dent 2009; 18:119-125)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550®) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550® denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II® reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II® reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner® material. Both hard chairside reline materials failed adhesively across Lucitone 550® denture base resin, in both periods of time. © 1999 Blackwell Science Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many techniques have been proposed for root coverage. However, none of them presents predictable results in deep and wide recessions. Objective: The aim of this case series report is to describe an alternative technique for root coverage at sites showing deep recessions and attachment loss >4 mm at buccal sites. Material and Methods: Four patients presenting deep recession defects at buccal sites (>= 4 mm) were treated by the newly forming bone graft technique, which consists in the creation of an alveolar socket at edentulous ridge and transferring of granulation tissue present in this socket to the recession defect after 21 days. Clinical periodontal parameters, including recession depth (RD), probing depth (PD), clinical attachment level (CAL), bleeding on probing (BOP), plaque index (PI) and keratinized gingiva width (KGW) were evaluated by a single examiner immediately before surgery and at 1, 3, 6 and 9 months postoperatively. Results: All cases showed reduction in RD and PD, along with CAL gain, although no increase in KGW could be observed. These findings suggest that the technique could favor periodontal regeneration along with root coverage, especially in areas showing deep recessions and attachment loss.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this investigation was to determine the fate of thin buccal bone encasing the prominent roots of maxillary anterior teeth following extraction. Resorption of the buccal plate compromises the morphology of the localized edentulous ridge and makes it challenging to place an implant in the optimal position for prosthetic restoration. In addition, the use of Bio-Oss as a bone filler to maintain the form of the edentulous ridge was evaluated. Nine patients were selected for the extraction of 36 maxillary anterior teeth. Nineteen extraction sockets received Bio-Oss, and seventeen sockets received no osteogenic material. All sites were completely covered with soft tissue at the conclusion of surgery. Computerized tomographic scans were made immediately following extraction and then at 30 to 90 days after healing so as to assess the fate of the buccal plates and resultant form of the edentulous sites. The results were assessed by an independent radiologist, with a crest width of 6 mm regarded as sufficient to place an implant. Those sockets treated with Bio-Oss demonstrated a loss of less than 20% of the buccal plate in 15 of 19 test sites (79%). In contrast, 12 of 17 control sockets (71%) demonstrated a loss of more than 20% of the buccal plate. In conclusion, the Bio-Oss test sites outperformed the control sites by a significant margin. No investigator was able to predict which site would be successful without the grafting material even though all were experienced clinicians. This leads to the conclusion that a patient has a significant benefit from receiving grafting materials at the time of extraction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A presente Tese de Mestrado em Medicina Dentária tem como tema a Piezocirurgia e, sobre ela, pretende-se saber a sua aplicabilidade no consultório do Médico Dentista, nomeadamente na área da Cirurgia oral. A pesquisa bibliográfica foi realizada através de bases de dados, como a Medline, Science Direct e a Pub-Med, entre outras. Limitou-se a pesquisa, temporalmente, entre 2000 e 2016, e nas línguas Portuguesa e Inglesa. Excluiu-se todas as referências a estudos animais e, todas as que, em nada, contribuiríam para o conteúdo especificado. A cirurgia Piezoeléctrica é uma técnica de osteotomia atraumática, quando comparada a técnicas convencionais, e que revoluciona a área da Cirurgia Oral, através do seu corte preciso e altamente selectivo, mas também através do fenómeno de cavitação que a caracteriza, e que garante um campo operatório livre, uma óptima visibilidade, e, consequentemente, uma maior segurança do operador, culminando tudo isto no sucesso do tratamento. A sua maior desvantagem é o tempo de trabalho que requere, contudo este tende a diminuir, e a ser ainda menor que o tempo de trabalho exigido na cirurgia convencional. Inúmeras são as aplicações da Piezocirurgia, mas na área da Medicina Dentária, nomeadamente na Cirurgia Oral, destaca-se o levantamento do seio maxilar, o aumento da crista óssea, a extracção dos terceiros molares impactados e a cirurgia ortognática.