998 resultados para dynamic hip screw


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of the proximal femur are common in the elderly population. Intramedullary nailing has become the standard treatment for intertrochanteric fractures although several extramedullary implants (e.g. dynamic hip screw (DHS), blade plate, locking compression plate (LCP), etc.) exist. However, despite this being a very common operation in traumatology, there are numerous associated complications. We report the rare complication of the migration of the medial lag screw into the pelvis at five and a half weeks postoperatively. The implant was removed and replaced by a total hip arthroplasty with simultaneous grafting of the acetabular defect and strapping of the greater trochanter. The evolution was favourable. We also present a review of the literature and analyze our case.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Femoral neck fracture without associated trauma following consolidation of a transtrochanteric fracture is a rare event. The authors report a case of transtrochanteric fracture that was treated with PFN and which presented fracturing of the femoral neck two weeks after removal of the device. This occurrence was treated with partial arthroplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: Las fracturas intertrocantéricas han llegado a nuestros días con una mayor incidencia dado el envejecimiento de la población, con fracturas más complejas, menos estables y asociadas a osteoporosis, se estima que representan aproximadamente 1,75 millones de años de vida perdidos ajustados a discapacidad es decir 0,1% de la carga de morbilidad a nivel mundial. Existe consenso en el tratamiento quirúrgico de este tipo de fracturas, presentando una incidencia variable de fallos, principalmente cuando son inestables, entre estos el denominado “cuto ut”. La utilización de un método de fijación con placa y tornillo helicoidal (DHHS) aparentemente disminuye la incidencia de dichos fallos con respecto a otras técnicas. Metodología: Por medio de una muestra calculada en 128 de pacientes con fracturas intertrocantéricas operados con DHS y DHHS entre el 2007 y el 2012 en La Clínica San Rafael de la ciudad de Bogotá, Colombia, se realizó un análisis multivariado para determinar si existe o no diferencias significativas en los índices de fallo entre estas dos técnicas. Resultados: Los pacientes incluidos en el estudio 54 (42,1%) fueron hombres y 74 (57,8%) fueron mujeres. 75 fueron operados con DHHS y 53 con DHS; en cuanto a las comorbilidades las principales fueron Hipertensión con 40 pacientes para DHS y 30 para DHHS, para el caso de Diabetes Mellitus fueron 13 y 9 para DHS y DHHS, respectivamente; en cuanto al tipo de fractura más común la principal fue la clasificación Tronzo II con 9 pacientes para DHS y 13 para DHHS. Conclusión. Para el estudios se evidencia que para los 3 desenlaces principales evaluados, 1. El porcentaje de re intervención (p=0,282), 2. La supervivencia en el primer año (p=0,499) y 3. El desempeño funcional con la escala de Oxford (p=0,06); no hubo diferencias estadísticamente significativas entre los grupos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Las fracturas intertrocantericas son una importante causa de la morbimortalidad en los adultos mayores. Requieren la mayoria manejo quirurgico. No se ha logrado definir si es mejor el tratamiento con osteosintesis o artoplastia de cadera. Por esta razon decidimos realizar un estudio identificando los resultados en cada uno de los tratamientos con poblacion colombiana en el Hospital Universitario Mayor Mederi. Metodos: Estudio de serie de casos. Se analizó una cohorte retrospectiva de pacientes mayores de 59 años con fractura intertrocantérica en el Hospital Universitario Mayor Méderi. Resultados: Se reportaron un total de 179 pacientes con diagnóstico de fractura intertrocantérica. De los cuales se realizaron 100 osteosíntesis , 20 reemplazos totales de cadera y 59 hemiartroplastias. La mortalidad fueron 11 pacientes que corresponde al 6.1%, 3 fueron hombres y 8 mujeres, en cuanto al procedimiento realizado a 7 pacientes se les realizo osteosíntesis y a los 4 restantes se les realizo hemiartroplastia. En total 7 infecciones las cuales se presentaron respectivamente en 6 osteosíntesis y 1 hemiartroplastia. Discusión: La mortalidad fue mayor en la osteosíntesis con 7 pacientes que equivale al 63,6 % de la mortalidad total del estudio. Los porcentajes de infección postoperatoria fueron mayores en la osteosíntesis , encontrándose que del total de pacientes intervenidos 3,9% se infectaron y de estos el 85,7 % corresponden a osteosíntesis versus 14,3% de hemiartroplastia. El sangrado postoperatorio fue mayor a 500 cc en un 39% de las osteosíntesis y en un 44% en las hemiartroplastias. Conclusión: el tratamiento de las fracturas intertrocantéricas tuvo menor mortalidad y menor porcentaje de infección cuando los pacientes fueron tratados con hemiartroplastia y reemplazo total de cadera.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pereira, GR, Leporace, G, Chagas, DV, Furtado, LFL, Praxedes, J, and Batista, LA. Influence of hip external rotation on hip adductor and rectus femoris myoelectric activity during a dynamic parallel squat. J Strength Cond Res 24(10): 27492754, 2010-This study sought to compare the myoelectric activity of the hip adductors (HAs) and rectus femoris (RF) when the hip was in a neutral position or externally rotated by 30 degrees or 50 degrees (H0, H30, and H50, respectively) during a parallel squat. Ten healthy subjects performed 10 repetitions of squats in each of the 3 hip positions and the myoelectric activities of the HAs and RF were recorded. The signal was then divided into categories representing concentric (C) and eccentric (E) contractions in the following ranges of motion: 0-30 degrees (C1 and E1), 30-60 degrees (C2 and E2), and 60-90 degrees (C3 and E3) of knee flexion. From those signals, an root mean square (RMS) value for each range of motion in each hip position was obtained. All values were normalized to those obtained during maximum voluntary isometric contraction. We found that HAs showed a significant increase in myoelectric activity during C3 and E3 in the H30 and H50 positions, as compared with H0. Meanwhile, RF activity did not significantly differ between hip positions. Both muscles showed higher activation during 60-90 degrees (C3 and E3) of knee flexion, as compared with 0-30 degrees (C1 and E1) and 30-60 degrees (C2 and E2). The results suggest that if the aim is to increase HA activity despite the low percentage of muscle activation, squats should be performed with 30 degrees of external rotation and at least 90 degrees of knee flexion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Screw dislocations in bcc metals display non-planar cores at zero temperature which result in high lattice friction and thermally-activated strain rate behavior. In bcc W, electronic structure molecular statics calculations reveal a compact, non-degenerate core with an associated Peierls stress between 1.7 and 2.8 GPa. However, a full picture of the dynamic behavior of dislocations can only be gained by using more efficient atomistic simulations based on semiempirical interatomic potentials. In this paper we assess the suitability of five different potentials in terms of static properties relevant to screw dislocations in pure W. Moreover, we perform molecular dynamics simulations of stress-assisted glide using all five potentials to study the dynamic behavior of screw dislocations under shear stress. Dislocations are seen to display thermally-activated motion in most of the applied stress range, with a gradual transition to a viscous damping regime at high stresses. We find that one potential predicts a core transformation from compact to dissociated at finite temperature that affects the energetics of kink-pair production and impacts the mechanism of motion. We conclude that a modified embedded-atom potential achieves the best compromise in terms of static and dynamic screw dislocation properties, although at an expense of about ten-fold compared to central potentials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of the hip joint formulation on the kinematic response of the model of human gait is investigated throughout this work. To accomplish this goal, the fundamental issues of the modeling process of a planar hip joint under the framework of multibody systems are revisited. In particular, the formulations for the ideal, dry, and lubricated revolute joints are described and utilized for the interaction of femur head inside acetabulum or the hip bone. In this process, the main kinematic and dynamic aspects of hip joints are analyzed. In a simple manner, the forces that are generated during human gait, for both dry and lubricated hip joint models, are computed in terms of the system’s state variables and subsequently introduced into the dynamics equations of motion of the multibody system as external generalized forces. Moreover, a human multibody model is considered, which incorporates the different approaches for the hip articulation, namely ideal joint, dry, and lubricated models. Finally, several computational simulations based on different approaches are performed, and the main results presented and compared to identify differences among the methodologies and procedures adopted in this work. The input conditions to the models correspond to the experimental data capture from an adult male during normal gait. In general, the obtained results in terms of positions do not differ significantly when the different hip joint models are considered. In sharp contrast, the velocity and acceleration plotted vary significantly. The effect of the hip joint modeling approach is clearly measurable and visible in terms of peaks and oscillations of the velocities and accelerations. In general, with the dry hip model, intra-joint force peaks can be observed, which can be associated with the multiple impacts between the femur head and the cup. In turn, when the lubricant is present, the system’s response tends to be smoother due to the damping effects of the synovial fluid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To review, retrospectively, the possible causes of sub- or intertrochanteric fractures after screw fixation of intracapsular fractures of the proximal femur. METHODS: Eighty-four patients with an intracapsular fracture of proximal femur were operated between 1995 and 1998 by using three cannulated 6.25 mm screws. The screws were inserted in a triangular configuration, one screw in the upper part of the femoral neck and two screws in the inferior part. Between 1999 and 2001, we use two screws proximally and one screw distally. RESULTS: In the first series, two patients died within one week after operation. Sixty-four fractures healed without problems. Four patients developed an atrophic non-union; avascular necrosis of the femoral head was found in 11 patients. Three patients (3.6%) suffered a sub- and/or intertrochanteric fracture after a mean postoperative time of 30 days, in one case without obvious trauma. In all three cases surgical revision was necessary. Between 1999 and 2001 we did not observe any fracture after screwing. CONCLUSION: Two screws in the inferior part of the femoral neck create a stress riser in the subtrochanteric region, potentially inducing a fracture in the weakened bone. For internal fixation for proximal intracapsular femoral fracture only one screw must be inserted in the inferior part of neck.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The platelet surface is a dynamic interface that changes rapidly in response to stimuli to coordinate the formation of thrombi at sites of vascular injury. Tight control is essential as loss of organisation may result in the inappropriate formation of thrombi (thrombosis) or excessive bleeding. In this paper we describe the comparative analysis of resting and thrombin-stimulated platelet membrane proteomes and associated proteins to identify proteins important to platelet function. Surface proteins were labelled using a biotin tag and isolated by NeurtrAvidin affinity chromatography. Liquid phase IEF and SDS-PAGE were used to separate proteins, and bands of increased intensity in the stimulated platelet fractions were digested and identified by FT-ICR mass spectrometry. Novel proteins were identified along with proteins known to be translocated to the platelet surface. Furthermore, many platelet proteins revealed changes in location associated with function, including G6B and Hip-55. HIP-55 is an SH3-binding protein important in T-cell receptor signalling. Further analysis of HIP-55 revealed that this adaptor protein becomes increasingly associated with both Syk and integrin beta 3 upon platelet activation. Analysis of HIP-55 deficient platelets revealed reduced fibrinogen binding upon thrombin stimulation, suggesting HIP-55 to be an important regulator of platelet function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The literature indicated that the majority of professional ballet dancers present static and active dynamic range of motion difference between left and right lower limbs, however, no previous study focused this difference in non-professional ballet dancers. In this study we aimed to evaluate active movements of the hip in non-professional classical dancers.Methods: We evaluated 10 non professional ballet dancers (16-23 years old). We measured the active range of motion and flexibility through Well Banks. We compared active range of motion between left and right sides (hip flexion and abduction) and performed correlation between active movements and flexibility.Results: There was a small difference between the right and left sides of the hip in relation to the movements of flexion and abduction, which suggest the dominant side of the subjects, however, there was no statistical significance. Bank of Wells test revealed statistical difference only between the 1st and the 3rd measurement. There was no correlation between the movements of the hip (abduction and flexion, right and left sides) with the three test measurements of the bank of Wells.Conclusion: There is no imbalance between the sides of the hip with respect to active abduction and flexion movements in non-professional ballet dancers. © 2011 Valenti et al; licensee BioMed Central Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Among the locked internal fixators is one denominated S.P.S. (Synthesis Pengo System) Free-Block, which was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw angulation on the resistance of the S.P.S. Free--Block plate. Methods: Forty synthetic bone cylinders with 10 mm fracture gap were used. Forty seven-hole 3.5 mm stainless steel plates (two AO-like dynamic compression holes and five locked holes) were assembled according to the orientation of the locked screws: mono cortical screws were positioned at 90° to the long axis of the cylinder (Group 1), and monocortical screws were positioned at 70° to its cylinder long axis (Group 2). In both groups, AO-like dynamic compression hole screws were positioned bicortically and neutrally. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure --seven by bending and seven in compression. Results: No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. Clinical significance: In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block to tests of axial compression and four-point bending. © Schattauer 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The literature indicated that the majority of professional ballet dancers present static and active dynamic range of motion difference between left and right lower limbs, however, no previous study focused this difference in non-professional ballet dancers. In this study we aimed to evaluate active movements of the hip in non-professional classical dancers. Methods We evaluated 10 non professional ballet dancers (16-23 years old). We measured the active range of motion and flexibility through Well Banks. We compared active range of motion between left and right sides (hip flexion and abduction) and performed correlation between active movements and flexibility. Results There was a small difference between the right and left sides of the hip in relation to the movements of flexion and abduction, which suggest the dominant side of the subjects, however, there was no statistical significance. Bank of Wells test revealed statistical difference only between the 1st and the 3rd measurement. There was no correlation between the movements of the hip (abduction and flexion, right and left sides) with the three test measurements of the bank of Wells. Conclusion There is no imbalance between the sides of the hip with respect to active abduction and flexion movements in non-professional ballet dancers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last 10 years the number of mobile devices has grown rapidly. Each person usually brings at least two personal devices and researchers says that in a near future this number could raise up to ten devices per person. Moreover, all the devices are becoming more integrated to our life than in the past, therefore the amount of data exchanged increases accordingly to the improvement of people's lifestyle. This is what researchers call Internet of Things. Thus, in the future there will be more than 60 billions of nodes and the current infrastructure is not ready to keep track of all the exchanges of data between them. Therefore, infrastructure improvements have been proposed in the last years, like MobileIP and HIP in order to facilitate the exchange of packets in mobility, however none of them have been optimized for the purpose. In the last years, researchers from Mid Sweden University created The MediaSense Framework. Initially, this framework was based on the Chord protocol in order to route packets in a big network, but the most important change has been the introduction of PGrids in order to create the Overlay and the persistence. Thanks to this technology, a lookup in the trie takes up to 0.5*log(N), where N is the total number of nodes in the network. This result could be improved by further optimizations on the management of the nodes, for example by the dynamic creation of groups of nodes. Moreover, since the nodes move, an underlaying support for connectivity management is needed. SCTP has been selected as one of the most promising upcoming standards for simultaneous multiple connection's management.