1000 resultados para drug implant


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cardiac arrhythmias are a frequent cause of death and morbidity. Conventional antiarrhythmia therapy involving oral or intravenous medication is often ineffective and complicated by drug-associated side effects. Previous studies from our laboratory have demonstrated the advantages of cardiac drug-polymer implants for enhanced efficacy for cardiac arrhythmia therapy compared with conventional administration. However, these studies were based on systems that deliver drugs at a fixed release rate. Modulation of the drug delivery rate has the advantage of regulating the amount of the drug delivered depending upon the disease state of the patient. We hypothesized that iontophoresis could be used to modulate cardiac drug delivery. In this study, we report our investigations of a cardiac drug implant in dogs that is capable of iontophoretic modulation of the administration of the antiarrhythmic agent sotalol. We used a heterogeneous cation-exchange membrane (HCM) as an electrically sensitive and highly efficient rate-limiting barrier on the cardiac-contacting surface of the implant. Thus, electric current is passed only through the HCM and not the myocardium. The iontophoretic cardiac implant demonstrated in vitro drug release rates that were responsive to current modulation. In vivo results in dogs have confirmed that iontophoresis resulted in regional coronary enhancement of sotalol levels with current-responsive increases in drug concentrations. We also observed acute current-dependent changes in ventricular effective refractory periods reflecting sotalol-induced refractoriness due to regional drug administration. In 30-day dog experiments, iontophoretic cardiac implants demonstrated robust sustained function and reproducible modulation of drug delivery kinetics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes were implanted into rat subcutaneous tissue and the animals were sacrificed after 7 and 30 days. The undecalcified pieces were prepared for histological analysis with polarized light and von Kossa technique for mineralized tissues. Granulations birefringent to polarized light and an irregular structure like a bridge were observed next to the material; both were von Kossa positive. Also, in the dentin wall tubules a layer of birefringent granulations was observed. The results were similar to those reported for gray MTA, indicating that the mechanisms of action of the white and gray MTA are similar.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Postanesthetic pain is a relatively common complication after local anesthesia. This complication may be caused by the anesthetic technique or by the anesthetic solution used. Tissue reactions induced by the anesthetic solutions may be one of the factors resulting in pain after anesthesia. The objective of this study was to comparatively analyze tissue reactions induced by different anesthetic solutions in the subcutaneous tissue of rats. The following solutions were utilized: 2% lidocaine without vasoconstrictor; a 0.5% bupivacaine solution with 1:200,000 adrenaline; a 4% articaine solution and 2% mepivacaine, both with 1:100,000 adrenaline; and a 0.9% sodium chloride solution as a control. Sterilized absorbent paper cones packed inside polyethylene tubes were soaked in the solutions and implanted in the subcutaneous region. The sacrifice periods were 1, 2, 5, and 10 days after surgery. The specimens were prepared and stained with hematoxylin and eosin for histological analysis. The results showed that there is a difference in tissue irritability produced by the local anesthetic solutions. The results also showed that there is no relation between the concentration of the drug and the inflammatory intensity, that the mepivacaine and articaine solutions promoted less inflammatory reaction than the bupivacaine, and that the lidocaine solution produced the least intense inflammation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cochlear implants are neuroprostheses that are inserted into the inner ear to directly electrically stimulate the auditory nerve, thus replacing lost cochlear receptors, the hair cells. The reduction of the gap between electrodes and nerve cells will contribute to technological solutions simultaneously increasing the frequency resolution, the sound quality and the amplification of the signal. Recent findings indicate that neurotrophins (NTs) such as brain derived neurotrophic factor (BDNF) stimulate the neurite outgrowth of auditory nerve cells by activating Trk receptors on the cellular surface (1–3). Furthermore, small-size TrkB receptor agonists such as di-hydroxyflavone (DHF) are now available, which activate the TrkB receptor with similar efficiency as BDNF, but are much more stable (4). Experimentally, such molecules are currently used to attract nerve cells towards, for example, the electrodes of cochlear implants. This paper analyses the scenarios of low dose aspects of controlled release of small-size Trk receptor agonists from the coated CI electrode array into the inner ear. The control must first ensure a sufficient dose for the onset of neurite growth. Secondly, a gradient in concentration needs to be maintained to allow directive growth of neurites through the perilymph-filled gap towards the electrodes of the implant. We used fluorescein as a test molecule for its molecular size similarity to DHF and investigated two different transport mechanisms of drug dispensing, which both have the potential to fulfil controlled low-throughput drug-deliverable requirements. The first is based on the release of aqueous fluorescein into water through well-defined 60-μm size holes arrays in a membrane by pure osmosis. The release was both simulated using the software COMSOL and observed experimentally. In the second approach, solid fluorescein crystals were encapsulated in a thin layer of parylene (PPX), hence creating random nanometer-sized pinholes. In this approach, the release occurred due to subsequent water diffusion through the pinholes, dissolution of the fluorescein and then release by out-diffusion. Surprisingly, the release rate of solid fluorescein through the nanoscopic scale holes was found to be in the same order of magnitude as for liquid fluorescein release through microscopic holes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the potential of 980-nm gallium aluminum arsenide (GaAlAs) and 1064-nm neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers to reduce bacteria after irradiation of implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis and on irradiated implant surface morphology. Background: Despite the frequency of implant success, some implant loss is related to peri-implantitis because of difficulty in eliminating the biofilm. Methods: Implants (3.75 x 13 mm) with machined surfaces, surfaces sand blasted with titanium oxide (TiO(2)), and sand-blasted and acid-etched surfaces were exposed to P. gingivalis and E. faecalis cultures and irradiated with 980-nm GaAlAs or 1064-nm Nd: YAG lasers. After laser treatments, the number of remaining colony-forming units and implant surface morphology were analyzed using scanning electron microscopy (SEM). Results: The Nd: YAG laser was able to promote a total contamination reduction on all implants irradiated. The results with the GaAlAs laser showed 100% bacteria reduction on the implants irradiated with 3 W. Irradiation with 2.5 W and 3 W achieved 100% of bacteria reduction on P. gingivalis-contaminated implants. Decontamination was not complete for the sand-blasted TiO(2) (78.6%) and acid-etched surfaces (49.4%) contaminated with E. faecalis and irradiated with 2.5 W. SEM showed no implant surface changes. Conclusion: The wavelengths used in this research provided bacteria reduction without damaging implant surfaces. New clinical research should be encouraged for the use of this technology in the treatment of peri-implantitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The search for an ideal filler for soft tissue augmentation still continues. Because aging changes are continuous, temporary fillers should be preferred against permanent ones. Since 1999, the poly-L-lactic acid filler (PLA) has been marketed in Europe as Newfill. As a synthetic biocompatible polymer, PLA originally was used in suture materials and screws. In 2004, the U.S. Food and Drug Administration approved PLA under the name of Sculptra for the treatment of human immunodeficiency virus-related facial lipoatrophy. This study aimed to evaluate a 3-year follow-up investigation into the effect of PLA implant injection for the treatment of sunken nasolabial folds. Between October 2003 and February 2004, 10 women with a median age of 54 years (range, 43-60 years) were injected with polylactic acid hydrogel (Newfill) in the nasolabial fold area for aesthetic reasons. All the patients underwent three injections: one injection per month for 3 months. Evaluation of the results based on clinical examination and photography was performed at each session, at 6 months, and then 36 months after the third session. Injectable PLA was able to correct nasolabial folds successfully with a more lasting result than absorbable fillers commonly used in clinical practice, such as hyaluronic acid and collagen. Careful and standardized photographic documentation is indispensable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetic macular oedema (DMO) is a leading cause of vision loss in the working-age population worldwide. Corticosteroid drugs have been demonstrated to inhibit the expression of both the vascular endothelial growth factor (VEGF) gene and other anti-inflammatory mediators, such as prostaglandins. Triamcinolone, fluocinolone and dexamethasone are the main steroids that have been studied for the treatment of macular oedema. Over the last few years, several studies have suggested an important role for dexamethasone in the management of DMO. The dexamethasone intravitreal implant (DEX implant) (Ozurdex®; Allergan, Inc., Irvine, CA) is a novel approach approved by the US Food and Drug Administration (FDA) and by the EU for the intravitreal treatment of macular oedema after branch or central retinal vein occlusion, and for the treatment of non-infectious uveitis affecting the posterior segment of the eye. We reviewed manuscripts that had investigated the pharmacokinetics, efficacy and safety of the DEX implant regarding DMO treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nexplanon (Schering-Plough Limited/Merck Sharp & Dohme Limited (MSD)) is a long active reversible contraceptive method that provides effective contraception for 3 years. It consists of a single, flexible, rod-shaped implant, containing 68 mg etonogestrel. It is 4 cm long, consists of an ethylene vinyl acetate copolymer, a non-absorbable material, and also contains 15 mg of barium sulfate, which makes it visible by X-ray. We describe a case of a 39-year-old woman who experienced a local reaction to the barium sulfate in Nexplanon. She was given medical treatment, but only the removal of the implant resolved the symptoms. After removal there was gradual improvement and 72 h later the patient was asymptomatic. Allergic reaction to barium sulfate is extremely rare: until now, there have only been two cases associated with Nexplanon described in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Limited treatment options are available for implant-associated infections caused by methicillin (meticillin)-resistant Staphylococcus aureus (MRSA). We compared the activity of daptomycin (alone and with rifampin [rifampicin]) with the activities of other antimicrobial regimens against MRSA ATCC 43300 in the guinea pig foreign-body infection model. The daptomycin MIC and the minimum bactericidal concentration in logarithmic phase and stationary growth phase of MRSA were 0.625, 0.625, and 20 microg/ml, respectively. In time-kill studies, daptomycin showed rapid and concentration-dependent killing of MRSA in stationary growth phase. At concentrations above 20 microg/ml, daptomycin reduced the counts by >3 log(10) CFU/ml in 2 to 4 h. In sterile cage fluid, daptomycin peak concentrations of 23.1, 46.3, and 53.7 microg/ml were reached 4 to 6 h after the administration of single intraperitoneal doses of 20, 30, and 40 mg/kg of body weight, respectively. In treatment studies, daptomycin alone reduced the planktonic MRSA counts by 0.3 log(10) CFU/ml, whereas in combination with rifampin, a reduction in the counts of >6 log(10) CFU/ml was observed. Vancomycin and daptomycin (at both doses) were unable to cure any cage-associated infection when they were given as monotherapy, whereas rifampin alone cured the infections in 33% of the cages. In combination with rifampin, daptomycin showed cure rates of 25% (at 20 mg/kg) and 67% (at 30 mg/kg), vancomycin showed a cure rate of 8%, linezolid showed a cure rate of 0%, and levofloxacin showed a cure rate of 58%. In addition, daptomycin at a high dose (30 mg/kg) completely prevented the emergence of rifampin resistance in planktonic and adherent MRSA cells. Daptomycin at a high dose, corresponding to 6 mg/kg in humans, in combination with rifampin showed the highest activity against planktonic and adherent MRSA. Daptomycin plus rifampin is a promising treatment option for implant-associated MRSA infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug-eluting microspheres are used for embolization of hypervascular tumors and allow for local controlled drug release. Although the drug release from the microspheres relies on fast ion-exchange, so far only slow-releasing in vitro dissolution methods have been correlated to in vivo data. Three in vitro release methods are assessed in this study for their potential to predict slow in vivo release of sunitinib from chemoembolization spheres to the plasma, and fast local in vivo release obtained in an earlier study in rabbits. Release in an orbital shaker was slow (t50%=4.5h, 84% release) compared to fast release in USP 4 flow-through implant cells (t50%=1h, 100% release). Sunitinib release in saline from microspheres enclosed in dialysis inserts was prolonged and incomplete (t50%=9 days, 68% release) due to low drug diffusion through the dialysis membrane. The slow-release profile fitted best to low sunitinib plasma AUC following injection of sunitinib-eluting spheres. Although limited by lack of standardization, release in the orbital shaker fitted best to local in vivo sunitinib concentrations. Drug release in USP flow-through implant cells was too fast to correlate with local concentrations, although this method is preferred to discriminate between different sphere types.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.