965 resultados para drip-perfusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Segments of the canine internal mammary artery (35 mm in length) were suspended in vitro in an organ chamber containing physiological salt solution (95% O(2)/5% CO(2), pH = 7.4, 37 degrees C). Segments were individually cannulated and perfused at 5 ml/minute using a roller pump. Vasorelaxant activity of the effluent from the perfused internal mammary arteries was bioassayed by measuring the decrease in tension induced by the effluent of the coronary artery endothelium-free ring which had been contracted with prostaglandin F(2 alpha) (2 x 10(-6) M). Intraluminal perfusion of adenosine diphosphate (10(-5) M) induced significant increase in relaxant activity in the effluent from the perfused blood vessel. However, when adenosine diphosphate (10(-5) M) was added extraluminally to the internal mammary artery, no change in relaxant activity in the effluent was noted. In contrast, acetylcholine produced significant increase in the relaxant activity on the effluent of the perfused internal mammary artery with both intraluminal and extraluminal perfusion. The intraluminal and extraluminal release of endothelium-derived relaxing factor (EDRF) by acetylcholine (10(-5) M) can be inhibited by site-specific administration of atropine (10(-5) M). These experiments indicate that certain agonists can induce the release of EDRF only by binding to intravascular receptors while other agonists can induce endothelium-dependent vasodilatation by acting on neural side receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tabasco pepper production with CO(2) application using drip irrigation. Application of CO(2) through water reduces the soil solution pH, causing variations in nutrient mobility and consequent effects on the absorption. The objective of this study was to analyze the effects of carbon dioxide rates supplied by drip irrigation in the production of Capsicum frutescens L. crop. A randomized block design with four treatments and eight replications was used. The treatments were four rates of CO(2): 0 (T1), 451.95 (T2); 677.93 (T3) and 903.92 (T4) kg ha(-1). The fruits were counted and weighed; the length and the diameter were obtained from an average of 20 fruits per plant, randomly taken, from each treatment in the plot. The quadratic effect (p < 0.01) occurred for CO(2) on the yield and there was quadratic effect (p < 0.05) of the rates on the number of fruits. There were no effects of CO(2) rates on the green matter, dry matter and fruit length and diameter. The T2 treatment provided greater yield and higher number of fruits per plant with an increase of 16 and 26%, respectively in relation to T1 (without CO(2)). CO(2) application favored the increase in the yield because of the greater number of fruits per plant in the Tabasco pepper crop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increased use of marginal quality water with drip irrigation requires sound fertigation practices that reconcile environmental concerns with viable crop production objectives. We conducted experiments to characterize dynamics and patterns of soil solution within wet bulb formed by drip irrigation. Time-domain reflectometry probes were used to monitor the distribution of potassium nitrate (KNO(3)) and water distribution from drippers discharging at constant flow rates of 2, 4 and 8 L h(-1) in soil-filled containers. Considering results from different profiles, we observed greater solute storage near the dripper decreasing gradually towards the wetting front. About half of the applied KNO(3) solution (48%) was stored in the first layer (0-0.10 m) for all experiments, 29% was stored in the next layer (0.10-0.20 m). Comparing different dripper flow rates, we observed higher solution storage for 4 L h(-1), with 45, 53 and 47% of applied KNO(3) solution accumulating in the first layer (0-0.10 m) for dripper flow rates of 2, 4 and 8 L h(-1), respectively. The results suggest that based on the volume and frequency used in this experiment, it would be advantageous to apply small amounts of solution at more frequent intervals to reduce deep percolation losses of applied water and solutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to verify if the fungigation via drip irrigation is an alternative to the conventional method of spraying on tomato for controlling early blight. Tomato plants (variety Santa Clara) were grown in pots inside a greenhouse. Fifty days after transplanting, the plants were inoculated with Alternaria solani and treated with four different fungicides: azoxystrobin (8 g 100 L(-1)), difeconazole (50 mL 100 L(-1)), metiram+piraclostrobin (200 g 100 L(-1)) and tebuconazole (100 mL 100 L(-1)) using two applications methods: conventional spraying and fiingigation dripping. The control plants did not receive fungicide application. To assess the severity of the disease, we used a rating scale expressed as the area under the disease progress curve (AUDPC) and production factors, such as number, weight and average diameter of the fruit and its productivity. The experimental design was completely randomized in factorial scheme 4 x 2 + 1 with eight replicates. Each plot had one plant in one pot. A 27% reduction in disease severity was observed when compared with the control plants, with no significant difference noted regarding the application method. The number of fruits did not statistically differ between the treatments. The average weight and diameter of the fruits were superior in the plants that had fungicide application compared to the control plant, reflecting an increase in productivity. Fungigation through water dripping is an alternative to the conventional method of spraying cultured tomatoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isolated limb perfusion (ILP) with melphalan is used to treat recurrent melanoma. This study aimed to develop a microdialysis technique for melphalan tissue concentration measurement during ILP. The effects of melphalan concentration (50-600 mu g/ml), microdialysis flow rate (0.55-17.5 mu l/min), probe length (5-50 mm) and temperature (25-41.5 degrees C) on in vitro recovery were studied. In addition, in vivo recovery was measured in rat hindlimbs perfused with melphalan using 50 mm microdialysis probes implanted subcutaneously and into muscle. Both dialysate and tissue sample melphalan concentrations were determined by high performance liquid chromatography. The in vitro recovery of melphalan was not affected by melphalan concentration or temperature, but increased with probe length and decreased with flow rate. The melphalan concentrations in subcutaneous and muscle dialysates were not significantly different. A linear relationship was found between tissue dialysate concentrations and actual tissue concentrations of melphalan (r(2) = 0.97). Microdialysis is a potential method for tissue drug monitoring which may assist in the efficacious use of cytotoxics in human ILP. (C) 2000 Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion- and perfusion-weighted magnetic resonance imaging provides important pathophysiological information in acute bra-in ischemia. We performed a prospective study in 19 sub-6-hour stroke patients using serial diffusion- and perfusion-weighted imaging before intravenous thrombolysis, with repeat studies, both subacutely and at outcome. For comparison of ischemic lesion evolution and clinical outcome, we used a historical control group of 21 sub-6-hour ischemic stroke patients studied serially with diffusion- and perfusion-weighted imaging. The two groups were well matched for the baseline National Institutes of Health Stroke Scale and magnetic resonance parameters. Perfusion-weighted imaging-diffusion-weighted imaging mismatch was present in 16 of 19 patients treated with tissue plasminogen activator, and 16 of 21 controls. Perfusion-weighted imaging-diffusion-weighted imaging mismatch patients treated with tissue plaminogen activator had higher recanalization rates and enhanced reperfusion at day 3 (81% vs 47% in controls), and a greater proportion of severely hypoperfused acute mismatch tissue not progressing to infarction (82% vs -25% in controls). Despite similar baseline diffusion-weighted imaging lesions, infarct expansion was less in the recombinant tissue plaminogen activator group (14cm(3) vs 56cm(3) in controls). The positive effect of thrombolysis on lesion growth in mismatch patients translated into a greater improvement in baseline to outcome National Institutes of Health Stroke Scale in the group treated with recombinant tissue plaminogen activator, and a significantly larger proportion of patients treated with recombinant tissue plaminogen activator having a clinically meaningful improvement in National Institutes of Health Stroke Scale of;2:7 points. The natural evolution of acute perfusion-weighted imaging-diffusion-weighted imaging mismatch tissue may be altered by thrombolysis, with improved stroke outcome. This has implications for the use of diffusion- and perfusion-weighted imaging in selecting and monitoring patients for thrombolytic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The progressive changes in the water distribution within rabbit muscles were studied by nuclear magnetic resonance microscopy during the first 24 h postmortem. T-2 images revealed development of interspersed lines with higher signal intensities in the muscle, reflecting formation of channels containing mobile water. The appearance of the interspersed lines progressed throughout the measuring period and became increasingly evident. After about 3 h postmortem the signal intensity also increased in areas near the surface of the samples, which reflects migration of the mobile water to the sample surface. Proton density images showed the presence of a chemical shift artifact in the interspersed lines, implying that the intrinsic development of water channels progressed in close proximity to the connective tissue. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose-The Echoplanar Imaging Thrombolysis Evaluation Trial ( EPITHET) tests the hypothesis that perfusion-weighted imaging (PWI)-diffusion-weighted imaging (DWI) mismatch predicts the response to thrombolysis. There is no accepted standardized definition of PWI-DWI mismatch. We compared common mismatch definitions in the initial 40 EPITHET patients. Methods-Raw perfusion images were used to generate maps of time to peak (TTP), mean transit time (MTT), time to peak of the impulse response (Tmax) and first moment transit time (FMT). DWI, apparent diffusion coefficient ( ADC), and PWI volumes were measured with planimetric and thresholding techniques. Correlations between mismatch volume (PWIvol-DWIvol) and DWI expansion (T2(Day) (90-vol)-DWIAcute-vol) were also assessed. Results-Mean age was 68 +/- 11, time to MRI 4.5 +/- 0.7 hours, and median National Institutes of Health Stroke Scale (NIHSS) score 11 (range 4 to 23). Tmax and MTT hypoperfusion volumes were significantly lower than those calculated with TTP and FMT maps (P < 0.001). Mismatch >= 20% was observed in 89% (Tmax) to 92% (TTP/FMT/MTT) of patients. Application of a +4s ( relative to the contralateral hemisphere) PWI threshold reduced the frequency of positive mismatch volumes (TTP 73%/FMT 68%/Tmax 54%/MTT 43%). Mismatch was not significantly different when assessed with ADC maps. Mismatch volume, calculated with all parameters and thresholds, was not significantly correlated with DWI expansion. In contrast, reperfusion was correlated inversely with infarct growth (R= -0.51; P = 0.009). Conclusions-Deconvolution and application of PWI thresholds provide more conservative estimates of tissue at risk and decrease the frequency of mismatch accordingly. The precise definition may not be critical; however, because reperfusion alters tissue fate irrespective of mismatch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The main purpose of the present investigation was to describe a model of intestinal denervation and in situ intestinal ischemia-reperfusion injury in adult rats, with utilization of the distal branch of the superior mesenteric artery close to the cecum for perfusion. Methods. In the root of the mesentery, the mesenteric artery and vein were completely isolated. Close to the cecal valve, a lymphatic node served as the reference point for the localization of the cecal artery, which was cannulated for perfusion with cold lactated Ringer`s solution. One hundred adult male rats were utilized in the study. Results. In a pilot study, we demonstrated that the cold ischemia time was sufficient to promote histopathologic intestinal changes characteristic of ischemia-reperfusion injury. Among 88 operated animals, 62 (70.5%) survived the procedure. Conclusion. The experimental model described herein has the advantage of preserving the entire intestine, which makes it more suitable for studies of physiological and morphological alterations after intestinal transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conditions which influence the viability, integrity, and extraction efficiency of the isolated perfused rat liver were examined to establish optimal conditions for subsequent work in reperfusion injury studies including the choice of buffer, use of oncotic agents, hematocrit, perfusion flow rate, and pressure. Rat livers were perfused with MOPS-buffered Ringer solution with or without erythrocytes. Perfusates were collected and analyzed for blood gases, electrolytes, enzymes, radioactivity in MID studies, and lignocaine in extraction studies. Liver tissue was sampled for histological examinations, and wet:dry weight of the liver was also determined. MOPS-buffered Ringer solution was found to be superior to Krebs bicarbonate buffer, in terms of pH control and buffering capacity, especially during any prolonged period of liver perfusion. A pH of 7.2 is chosen for perfusion since this is the physiological pH of the portal blood. The presence of albumin was important as an oncotic agent, particularly when erythrocytes were used in the perfusate. Perfusion pressure, resistance, and vascular volume are how-dependent and the inclusion of erythrocytes in the perfusate substantially altered the flow characteristics for perfusion pressure and resistance but not vascular volume. Lignocaine extraction was relatively flow-independent. Perfusion injury as defined by enzyme release and tissue fine structure was closely related to the supply of O-2. The optimal conditions for liver perfusion depend upon an adequate supply of oxygen. This can be achieved by using either erythrocyte-free perfusate at a how rate greater than 6 ml/min/g liver or a 20% erythrocyte-containing perfusate at 2 ml/min/g. (C) 1996 Academic Press, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, stress myocardial computed tomographic perfusion (CTP) was shown to detect myocardial ischemia. Our main objective was to evaluate the feasibility of dipyridamole stress CTP and compare it to single-photon emission computed tomography (SPECT) to detect significant coronary stenosis using invasive conventional coronary angiography (CCA; stenosis >70%) as the reference method. Thirty-six patients (62 +/- 8 years old, 20 men) with previous positive results with SPECT (<2 months) as the primary inclusion criterion and suspected coronary artery disease underwent a customized multidetector-row CT protocol with myocardial perfusion evaluation at rest and during stress and coronary CT angiography (CTA). Multidetector-row computed tomography was performed in a 64-slice scanner with dipyridamole stress perfusion acquisition before a second perfusion/CT angiographic acquisition at rest. Independent blinded observers performed analysis of images from CTP, CTA, and CCA. All 36 patients completed the CT protocol with no adverse events (mean radiation dose 14.7 +/- 3.0 mSv) and with interpretable scans. CTP results were positive in 27 of 36 patients (75%). From the 9 (25%) disagreements, 6 patients had normal coronary arteries and 2 had no significant stenosis (8 false-positive results with SPECT, 22%). The remaining patient had an occluded artery with collateral flow confirmed by conventional coronary angiogram. Good agreement was demonstrated between CTP and SPECT on a per-patient analysis (kappa 0.53). In 26 patients using CCA as reference, sensitivity, specificity, and positive and negative predictive values were 88.0%, 79.3%, 66.7%, and 93.3% for CTP and 68.8, 76.1%, 66.7%, and 77.8%, for SPECT, respectively (p = NS). In conclusion, dipyridamole CT myocardial perfusion at rest and during stress is feasible and results are similar to single-photon emission CT scintigraphy. The anatomical-perfusion information provided by this combined CT protocol may allow identification of false-positive results by SPECT. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:310-315)