1000 resultados para doppler effect


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compute the shift in the frequency of the spin resonance in a solid that rotates in the field of a circularly polarized electromagnetic wave. Electron-spin resonance, nuclear magnetic resonance, and ferromagnetic resonance are considered. We show that contrary to the case of the rotating LC circuit, the shift in the frequency of the spin resonance has strong dependence on the symmetry of the receiver. The shift due to rotation occurs only when rotational symmetry is broken by the anisotropy of the gyromagnetic tensor, by the shape of the body or by magnetocrystalline anisotropy. General expressions for the resonance frequency and power absorption are derived and implications for experiment are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this Master Thesis we discuss issues related to the measurement of the effective scattering surface, based on the Doppler Effect. Modeling of the detected signal was made. Narrowband signal filtering using low-frequency amplifier was observed. Parameters of the proposed horn antennas were studied; radar cross section charts for three different objects were received.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

RESUMO: Enthesitis is the hallmark of spondyloarthritis (SpA), and is observed in all subtypes. Wide information on SpA abnormalities, including synovitis, tendinitis and enthesitis, can be efficiently perceived by Doppler ultrasound. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect enthesis alterations; and vascularized enthesitis detected by Doppler ultrasound appears to be a valuable diagnostic tool to confirm SpA diagnosis. However, data published until now concerning entheseal elementary alterations that characterize SpA enthesitis (enthesis inflammatory activity) or enthesopathy (permanent structural changes) reflect rather the authors’ empiric opinion than a methodological validation process. In this sense it seems crucial to identify elementary entheseal lesions associated with activity or damage, in order to improve monitoring and treatment response in SpA patients. The development of better assessment tools is today a challenge and a need in SpA. The first study of this thesis focused on the analysis of the reliability of inter-lector and inter-ultrasonography equipment of Madrid sonography enthesitis index (MASEI). Fundamental data for the remaining unrolling project validity. In the second and third studies we concerned about two entheseal elemental lesions: erosions and bursa. In literature erosions represent a permanent structural damage, being useful for monitoring joint injury, disease activity and therapeutic response in many rheumatic diseases; and to date, this concept has been mostly applied in rheumatoid arthritis (RA). Unquestionably, erosion is a tissue-related damage and a structural change. However, the hypothesis that we decided to test was if erosions represent a permanent structural change that can only grow and worsen over time, as occurs in RA, or a transitory alteration. A longitudinal study of early SpA patients was undertaken, and the Achilles enthesis was used as a model. Our results strongly suggested that previously detected erosions could disappear during the course of the disease, being consistent with the dynamic behavior of erosion over time. Based on these striking results it seems reasonable to suggest that the new-bone formation process in SpA could be associated with the resolution of cortical entheseal erosion over time. These results could also be in agreement with the apparent failure of anti-tumor necrosis factor (TNF) therapies to control bone proliferation in SpA; and with the relation of TNF-α, Dickkopf-related protein 1 (Dkk-1) and the regulatory molecule of the Wnt signaling pathway in the bone proliferation in SpA. In the same model, we then proceeded to study the enthesis bursa. Interestingly, the Outcome Measures in Rheumatology Clinical Trials (OMERACT) enthesopathy definition does not include bursa as an elementary entheseal lesion. Nonetheless, bursa was included in 46% of the enthesis studies in a recently systematic literature review, being in agreement with the concept of “synovio-entheseal complex” that includes the link between enthesitis and osteitis in SpA. It has been clarified in recent data that there is not only a close functional integration of the enthesis with the neighboring bone, but also a connection between enthesitis and synovitis. Therefore, we tried to assess the prevalence and relevance of the bursa-synovial lesion in SpA. Our findings showed a significant increase of Achilles bursa presence and thickness in SpA patients compared to controls (healthy/mechanical controls and RA controls). These results raise awareness to the need to improve the enthesopathy ultrasonographic definition. In the final work of this thesis, we have explored new perspectives, not previously reported, about construct validity of enthesis ultrasound as a possible activity outcome in SpA. We performed a longitudinal Achilles enthesis ultrasound study in patients with early SpA. Achilles ultrasound examinations were performed at baseline, six- and twelve-month time periods and compared with clinical outcome measures collected at basal visit. Our results showed that basal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are higher in patients with Doppler signal in enthesis, and even that higher basal ESR, CRP and Ankylosing Spondylitis Disease Activity Score (ASDAS) predicted a higher Doppler signal (an ultrasound alteration accepted as representative of inflammation) six months later. Patients with very high disease activity assessed by ASDAS (>3.5) at baseline had significantly higher Achilles total ultrasound score verified at the same time; and ASDAS <1.3 predicted no Doppler signal at six and twelve months. This seems to represent a connection between classical biomarkers and clinical outcomes associated with SpA activity and Doppler signal, not only at the same time, but also for the following months. Remarkably, patients with inactive disease (ASDAS < 1.3) at baseline had no Doppler signal at six and twelve months. These findings reinforce the potential use of ultrasound related techniques for disease progression assessment and prognosis purposes. Intriguingly, Ankylosing Spondylitis Disease Activity Index (BASDAI) didn’t show significant differences between different cut-offs concerning ultrasound lesions or Doppler signal, while verified with ASDAS. These results seem to indicate that ASDAS reflects better than BASDAI what happens in the enthesis. The work herein discussed clearly shows the potential utility of ultrasound in enthesis assessment in SpA patients, and can be important for the development of ultrasound activity and structural damage scores for diagnosis and monitoring purposes. Therefore, local promotion of this technique constitutes a medical intervention that is worth being tested in SpA patients for diagnosis, monitoring and prognosis purposes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The inverse scattering problem concerning the determination of the joint time-delayDoppler-scale reflectivity density characterizing continuous target environments is addressed by recourse to the generalized frame theory. A reconstruction formula,involving the echoes of a frame of outgoing signals and its corresponding reciprocalframe, is developed. A ‘‘realistic’’ situation with respect to the transmission ofa finite number of signals is further considered. In such a case, our reconstruction formula is shown to yield the orthogonal projection of the reflectivity density onto a subspace generated by the transmitted signals.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Hidrolipodistrofia ginóide (H.L.D.G.), a celulite, é comumente tratada com cosméticos contendo extratos vegetais. O estudo realizado foi: ultra-sonografia na avaliação da espessura da hipoderme e a microcirculação cutânea; uso de termômetro infravermelho na medida da temperatura e análise das medidas antropométricas da uma formulação cosmética anticelulítica contendo extrato hidroglicólico de Trichilia catigua e Ptychopetalum olacoides Bentham (catuaba e marapuama). Foram realizadas medidas iniciais e após aplicação da formulação. Os resultados apresentaram alterações estatisticamente significativas para a temperatura cutânea e medidas antropométricas. Não houve diferenças estatisticamente significativas nas medidas da hipoderme e microcirculação. Considerando os resultados, a formulação avaliada possui potencial ação coadjuvante na redução da hidrolipodistrofia ginóide. As técnicas podem ser associadas em conjunto com a avaliação sensorial e apreciabilidade cosmética. Os requisitos chaves para a reprodutibilidade das técnicas incluem ambiente controlado, monitoramento e climatização dos voluntários, procedimentos de medidas padronizados, protocolos de aplicação realístico e operadores qualificados.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Thesis (M.S.)--University of Illinois.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

"Contract no. NAS 8-1520."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El entorno aéreo es, a día de hoy, uno de los escenarios más complicados a la hora de establecer enlaces de comunicación fiables. Esto es debido, principalmente, a las altas velocidades a las que circulan los aviones, que propician una gran degradación del rendimiento des sistema si no se estima de forma continua el canal. Además el entorno aéreo es susceptible a sufrir muchos otros efectos que provocan la degradación de la señal, como la difracción, la reflexión, etc. Por este motivo en este proyecto se hace un estudio de dos escenarios típicos de vuelo: arrival (aterrizaje) y on route (vuelo en ruta). En el escenario on route los aviones circulan a más de el doble de velocidad que en el escenario arrival, de esta manera se podrá ver el efecto de sufrir un doppler mayor. Para realizar el estudio se utiliza un sistema multiportadora con solapamiento de subcanales, OFDM, y se toman inicialmente parámetros típicos de la tecnología WiMAX, que se variarán con el objetivo de mejorar el rendimiento del sistema.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is a need to measure energy expenditure in man for a period of 24 h or even several days. The respiration chamber offers a unique opportunity to reach this goal. It allows the study of energy and nutrient balance; from the latter, acute changes in body composition can be obtained. The respiration chamber built in Lausanne is an air-tight room (5 m long, 2.5 m wide, and 2.5 m high) which forms an open circuit ventilated indirect calorimeter. The physical activity of the subject inside the chamber is continuously measured using a radar system based on the Doppler effect. Energy expenditure of obese and lean women was continuously measured over 24 h and diet-induced thermogenesis was assessed by using an approach which allows one to subtract the energy expended for physical activity from the total energy expenditure. Expressed in absolute terms, total energy expenditure was more elevated in the obese than in the lean controls. Basal metabolic rate was also higher in the obese than in the controls, but diet-induced thermogenesis was found to be blunted in the obese. In a second study, the effect of changing the carbohydrate/lipid content of the diet on fuel utilization was assessed in young healthy subjects with the respiration chamber. After a 7-day adaptation to a high-carbohydrate low-fat diet, the fuel mixture oxidized matched the change in nutrient intake. A last example of the use of the respiration chamber is the thermogenic response and changes in body composition due to a 7-day overfeeding of carbohydrate. Diet-induced thermogenesis was found to be 27%; on the last day of overfeeding, carbohydrate balance was reached by oxidation of 50% of the carbohydrate intake, the remaining 50% being converted into lipid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quality control on fruits requires reliable methods, able to assess with reasonable accuracy and possibly in a non-destructive way their physical and chemical characteristics. More specifically, a decreased firmness indicates the presence of damage or defects in the fruit or else that the fruit has exceeded its “best before date”, becoming unsuitable for consumption. In high-value exotic fruits, such as mangoes, where firmness cannot be easily measured from a simple observation of texture, colour changes and unevenness of fruits surface, the use of non-destructive techniques is highly recommendable. In particular, the application of Laser vibrometry, based on the Doppler effect, a non-contact technique sensitive to differences in displacements inferior to the nanometre, appears ideal for a possible on-line control on food. Previous results indicated that a phase shift can be in a repeatable way associated with the presence of damage on the fruit, whilst a decreased firmness results in significant differences in the displacement of the fruits under the same excitation signal. In this work, frequency ranges for quality control via the application of a sound chirp are suggested, based on the measurement of the signal coherence. The variations of the average vibration spectrum of a grid of points, or of point-by-point signal velocity allows the go-no go recognition of “firm” and “over-ripe” fruits, with notable success in the particular case of mangoes. The future exploitation of this work will include the application of this method to allow on-line control during conveyor belt distribution of fruits.