983 resultados para domestic water heater
Resumo:
This paper presents major findings from a recent study aiming to systematically determine suitable river sections for local domestic water supply along the Yangtze River in Jiangsu Province, China. On the basis of analysis on the current riverbank utilization and bank stability, accessible and stable river sections in the region were selected. The water quality in these river sections was then studied using a two-dimensional unsteady flow and pollutant transport/transformation model, RBFVM-2D. The model was calibrated and verified against the hydrodynamic data, water quality data and remote sensing data collected from the river. The investigation on the pollution sources along the river identified 56 main pollution point sources. The pollution zones downstream of these point sources are the main threat for the water quality in the river. The model was used to compute the pollution zones. In particular, simulations were conducted to establish the relationship between the extent of the pollution zone and the wastewater discharge rate of the associated point source. These water quality simulation results were combined with the riverbank stability analysis to determine suitable river sections for local domestic water supply.
Resumo:
OBJECTIVE: To assess the impact of town planning, infrastructure, sanitation and rainfall on the bacteriological quality of domestic water supplies. METHODS: Water samples obtained from deep and shallow wells, boreholes and public taps were cultured to determine the most probable number of Escherichia coli and total coliform using the multiple tube technique. Presence of enteric pathogens was detected using selective and differential media. Samples were collected during both periods of heavy and low rainfall and from municipalities that are unique with respect to infrastructure planning, town planning and sanitation. RESULTS: Contamination of treated and pipe distributed water was related with distance of the collection point from a utility station. Faults in pipelines increased the rate of contamination (p<0.5) and this occurred mostly in densely populated areas with dilapidated infrastructure. Wastewater from drains was the main source of contamination of pipe-borne water. Shallow wells were more contaminated than deep wells and boreholes and contamination was higher during period of heavy rainfall (p<0.05). E. coli and enteric pathogens were isolated from contaminated supplies. CONCLUSIONS: Poor town planning, dilapidated infrastructure and indiscriminate siting of wells and boreholes contributed to the low bacteriological quality of domestic water supplies. Rainfall accentuated the impact.
Resumo:
UANL
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Hajautettu sähköntuotanto aurinkopaneeleilla on Suomessa kasvussa. Kotitalouksiin asennettujen aurinkopaneelijärjestelmien määrä kasvaa jatkuvasti, mutta suuri osa tuotetusta sähköenergiasta syötetään sähköverkkoon. Tämä johtuu aurinkosähkön tuotannon painottumisesta kesäpäiviin, jolloin kotitalouksien kulutus on pienimmillään. Suurin hyöty itse tuotetusta energiasta saadaan kuitenkin käyttämällä se tuotantokohteessa, jolla minimoidaan energiansiirto sähköverkon ja kotitalouden rajapinnassa. Siirtämällä kotitalouden suurimpia kuormia aurinkosähkön mukaan ohjatuksi, voidaan saavuttaa merkittäviä parannuksia tuotetun sähkön omakäyttöasteessa. Helpoimmillaan tämä onnistuu kellokytkimellä, joka ajoittaa kulutuksen parhaimman tuotannon ajalle. Tämä ei kuitenkaan poista ongelmaa tilanteissa, jossa aurinkosähkön tuotanto on häiriintynyt esimerkiksi pilvisyyden takia aamupäivällä ja huipputuotanto saavutetaan vasta iltapäivän puolella. Saatavilla on jo useita järjestelmiä, jotka ohjaavat kodin laitteita tuotannon mukaisesti. Suuri osa näistä järjestelmistä on kuitenkin suunniteltu toimimaan vain tuotetun energiamäärän mukaisesti, ottamatta huomioon kotitaloudessa olevaa muuta, automaation piiriin kuulumatonta kulutusta. Tässä kandidaatin työssä vertaillaan sähköenergian eri mittaustapoja ja niiden vaikutusta siirretyn energian laskennalliseen määrään. Lisäksi työssä tutkitaan lämminvesivaraajan kuormanohjausta käyttäen termostaatti-, kellokytkin- ja logiikkaohjausta. Työssä esitelty logiikkaohjaus hyödyntää siirretyn energian mittausta sähköverkon ja kotitalouden rajapinnassa, ottaen automaattisesti huomioon myös talouden muun kulutuksen. Työssä esitellään myös esimerkkilaitteisto, jolla suunniteltu logiikka voidaan toteuttaa.
Resumo:
Chlamydia-related bacteria classified in the Chlamydiales order, are strictly intracellular bacteria and are able for the most to replicate in free-living amoebae. Amoebae, ubiquitous in the environment and especially in water, are very resistant to disinfection used in drinking water production. Thus, amoebae may reach easily the distribution and domestic water system, potentially sheltering amoeba-resisting bacteria including Legionella, mycobacteria and Chlamydiales. Indeed, some of these amoeba-resisting bacteria have been shown to cause respiratory infections in people inhaling contaminated water. Therefore, an environmental and clinical study was conducted to determine if Chlamydiales bacteria are also involved in respiratory infections and if a transmission through domestic drinking water could occur. First, large scale molecular and serological tools specific of Chlamydia-related bacteria were developed and then were applied on clinical samples from patients with and without pneumonia. Simultaneously, water and biofilm samples from households of the same patients were investigated using molecular and culture methods for the presence of Chlamydiales bacteria. Chlamydiales were detected in the nasopharyngeal flora from patients with and without pneumonia. However, no significant difference was observed between both groups. Conversely, serological investigations showed that antibody reactivity against members of the Criblamydiaceae was associated with pneumonia. The thesis provided very efficient tools that showed the presence of Chlamydiales in human nasopharyngeal flora as well as in the majority of the domestic drinking water. However, no transmission from domestic drinking water to human could be demonstrated. These tools will help in the future specifying the ecology and pathogenicity of the Chlamydia-re\ated bacteria and especially of the species belonging to the Criblamydiaceae family.
Resumo:
Nowadays there are several ways of supplying hot water for showers in residential buildings. One of them is the use of electric storage water heaters (boilers). This equipment raises the water temperature in a reservoir (tank) using the heat generated by an electric resistance. The behavior of this equipment in Brazil is still a research object and there is not a standard in the country to regulate its efficiency. In this context, an experimental program was conducted aiming to collect power consumption data to evaluate its performance. The boilers underwent an operation cycle to simulate a usage condition aiming to collect parameters for calculating the efficiency. This 1-day cycle was composed of the following phases: hot water withdrawal, reheating and standby heat loss. The methods allowed the identification of different parameters concerning the boilers work, such as: standby heat loss in 24 h, hot water withdrawal rate, reheating time and energy efficiency. The average energy efficiency obtained was of 75%. The lowest efficiency was of 62% for boiler 2 and the highest was of 85% for boiler 9. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Concern about the neurotoxicity of lead, particularly in infants and young children, has led to a revision of blood lead levels which are considered to involve an acceptable level of human exposure. Drinking water guidelines have also been reviewed in order to reduce this source of population exposure to lead. In the last 20 years, guidelines have been reduced from 100 to 50 to 10 mu g/litre. Lead in tap water used to be a major public health problem in Glasgow because of the high prevalence of houses with lead service pipes, the low pH of the public water supply and the resulting high levels of lead in water used for public consumption. Following two separate programmes of water treatment, involving the addition of lime and, a decade later, lime supplemented with orthophosphate, it is considered that maximal measures have been taken to reduce lead exposure by chemical treatment of the water supply. Any residual problem of public exposure would require large scale replacement of lead service pipes. In anticipation of the more stringent limits for lead in drinking water, we set out to measure current lead exposure From tap water in the population of Glasgow served by the Loch Katrine water supply. to compare the current situation with 12 years previously and to assess the public health implications of different limits. The study was based on mothers of young children since maternal blood lead concentrations and the domestic water that mothers use to prepare bottle feeds are the principal sources of foetal and infant lead exposure. An estimated 17% of mothers lived in households with tap water lead concentrations of 10 mu g/litre (the WHO guideline) or above in 1993 compared with 49% in 1981. Mean maternal blood lead concentrations fell by 69% in 12 years. For a given water lead concentration, maternal blood lead concentrations were 67% lower. The mean maternal blood lead concentration was 3.7 mu g/litre in the population at large, compared with 3.3 mu g/litre in households with negligible or absent tap water lead. Nevertheless, between 63% and 76% of cases of mothers with blood lead concentrations of 10 mu g/dl or above were attributable to tap water lead. The study found that maternal blood lead concentrations were well within limits currently considered safe for human health. About 15% of infants may be exposed via bottle feeds to tap water lead concentrations that exceed the WHO guideline of 10 mu g/litre. In the context of the health and social problems which affect the well-being and development of infants and children in Glasgow, however, current levels of lend exposure are considered to present a relatively minor health problem. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
We evaluated the influence of water-related human activities, contaminative behaviour, house location, education and socio-economic status on endemic Schistosoma mansoni infection. The study was conducted in a hilry non-irrigated area of rural northeast Brazil amongst a defined population of subsistence farmers, of whom 93% were infected by age 20. The area was mapped, water bodies were surveyed, and a detailed questionnaire was performed on each household. Infection was assessed by duplicate stool examinations using the sensitive Bell technique to quantify egg excretion. For each household, and index of intensity of infection was computed by grouping individual log-transformed egg counts as an age-sex adjusted Z score. Few households had a sanitary installation or a domestic water supply. However, neither water-contact nor contaminative behavior were indiscriminate. The people made considerable effort to defaecate far from a water source, to obtain household drinking water from the cleanest source, and to bathe only at certain sites where privacy is assured. Land ownership and literacy correlated poorly with the household index of intensity of infection. The key influence on infection status was the relative location of the house and snail-free or snail colonized water sources. In this area, a safe domestic water supply is the critical input needed to achieve definitive control of endemic Schistosomiasis.
Estudo de uma bomba de calor de expansão direta assistida por energia solar para a preparação de AQS
Resumo:
Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.
Resumo:
Although there are many ways to cut you water heating bills, the all fall into two broad categories: reducing the amount of hot water you use and making your water heating system more efficient. Fortunately, there are several strategies that can help you consume less energy and save money - and still meet you hot water needs without sacrificing comfort or practicality. The booklet was designed to answer common questions about hot water systems and to provide you with the information necessary to make informed decision about a wide variety of topics, ranging from repairing hot water faucet leaks an insulation water supply pipes to installing low-flow shower heads and tuning you your existing water heather. You'll also find details on what to consider when it's time to go comparison shopping for a new water heater-including an evaluation of the alternatives to the common gas or electric storage tank unit that's found in the majority of homes in Iowa and across the country.
Käyttövesivaraajan ekosuunnitteluvaatimusten merkityksen arvioiminen rakennusten energianhallinnassa
Resumo:
Työn lähtökohtana ovat veden lämmittimiä koskeva ekosuunnittelulainsäädäntö ja sen vaatiman testausjärjestelmän laatiminen. Työn tavoitteena on arvioida ekosuunnittelulainsäädännön vaikutusta varaajan toimintaan osana rakennusten energianhallintaa. Työssä laaditaan käyttövesivaraajalle tuoteryhmäkohtaisen ekosuunnittelulainsäädännön mukainen mittausjärjestelmä energiatehokkuuden, lämpimän veden saannon, vuosittaisen sähkönkulutuksen sekä energiamerkinnän määrittämiseksi. Lisäksi tarkastellaan ekosuunnittelulainsäädännön tarkoituksenmukaisuutta, selvitetään varaajan toimintaperiaatteet sekä keinoja käyttöveden tarvitseman energian vähentämiseksi. Testattu käyttövesivaraaja täyttää ekosuunnitteluvaatimukset. Lämmitysenergian vähentäminen käyttövesivaraajan toimintaa tehostamalla on kuitenkin vaikeaa. Hybridijärjestelmien hyödyntäminen sähkölämmityksen ohella muita energianlähteitä ja esim. käyttöveden lämmöntalteenottoa käyttäen on toimivin keino vähentää käyttöveden energiankulutusta sekä parantaa varaajan energiatehokkuutta. Lämpimän käyttöveden energiankulutuksen osuus rakennuksen energiankulutuksesta kasvaa lainsäädännön pakottamana rakennusten kokonaisenergiankäytön vähentyessä. Ekosuunnittelulainsäädännön suora merkitys rakennusten energianhallintaan on Suomessa vähäistä nykyisen energiatehokkuustason ollessa suhteellisen korkea, jolloin käyttöveden tarvitseman energian vähentämiskeinoina on hyödynnettävä vaihtoehtoisia ratkaisuja.
Resumo:
Changing precipitation patterns and temperature relate directly to water resources and water security. This report presents the findings of an assessment of the water sector in Grenada with respect to the projected impact of climate change. Grenada‘s water resources comprise primarily surface water, with an estimated groundwater potential to satisfy about 10%-15% of the present potable requirement. On the smaller islands Carriacou and Petite Martinique, domestic water is derived exclusively from rainwater catchments. Rainfall seasonality is marked and the available surface water during the dry season declines dramatically. Changing land use patterns, increase in population, expansion in tourism and future implementation of proposed irrigation schemes are projected to increase future water requirements. Economic modeling approaches were implemented to estimate sectoral demand and supply between 2011 and 2050. Residential, tourism and domestic demand were analysed for the A2, B2 and BAU scenarios as illustrated. The results suggest that water supply will exceed forecasted water demand under B2 and BAU during all four decades. However under the A2 scenario, water demand will exceed water supply by the year 2025. It is important to note that the model has been constrained by the omission of several key parameters, and time series for climate indicators, data for which are unavailable. Some of these include time series for discharge data, rainfall-runoff data, groundwater recharge rates, and evapotranspiration. Further, the findings which seem to indicate adequacy of water are also masked by seasonality in a given year, variation from year to year, and spatial variation within the nation state. It is imperative that some emphasis be placed on data generation in order to better project for the management of Grenada‘s water security. This analysis indicates the need for additional water catchment, storage and distribution infrastructure, as well as institutional strengthening, in order to meet the future needs of the Grenadian population. Strategic priorities should be adopted to increase water production, increase efficiency, strengthen the institutional framework, and decrease wastage. Grenada has embarked on several initiatives that can be considered strategies toward adaptation to the variabilities associated with climate change. The Government should ensure that these programs be carried out to the optimal levels for reasons described above. The ―no-regrets approach‖ which intimates that measures will be beneficial with or without climate change should be adopted. A study on the Costs of Inaction for the Caribbean in the face of climate change listed Grenada among the countries which would experience significant impacts on GDP between now and 2100 without adaptation interventions. Investment in the water sector is germane to building Grenada‘s capacity to cope with the multivariate impact of changes in the parameters of climate.
Resumo:
Rainwater harvesting (RWH) has a long history and has been supported as an appropriate technology and relatively cheap source of domestic water supply. This study compares the suitability of RWH and piped water systems in three rural Dominican communities seeking to improve their water systems. Ethnographic methods considering the views of residents and feasibility and cost analysis of the options were used to conclude that RWH is not a feasible or cost-effective solution for domestic water needs of all households in the communities studied. RWH investment is best left to individual households that can implement informal RWH with incremental increases in storage volume. Piped water distribution (PWD) systems perceived as too large or expensive to implement have much lower capital costs and are more supported by residents as a solution because they provide large quantities of water needed to maintain water services beyond mere survival levels.