35 resultados para dipstick
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
INTRODUCTION: Various methods are used for the diagnosis of visceral leishmaniasis (VL), such as microscopic examination, culture and inoculation of laboratory animals; however, serological assays are commonly used for the detection of antibodies in serum samples with a wide range of specificity and sensitivity. METHODS: The purpose of this study was to compare three serological methods, including rA2-ELISA, the recombinant KE16 (rKE16) dipstick test and the direct agglutination test (DAT), for the detection of antibodies against VL antigens. The assays utilized 350 statistically based random serum samples from domestic dogs with clinical symptoms as well as samples from asymptomatic and healthy dogs from rural and urban areas of the Meshkinshahr district, northwestern Iran. RESULTS: Samples were assessed, and the following positive rates were obtained: 11.5% by rKE16, 26.9% by DAT and 49.8% by ELISA. The sensitivity among symptomatic dogs was 32.4% with rKE16, 100% with DAT and 52.9% with ELISA. Conversely, rA2-ELISA was less specific for asymptomatic dogs, at 46.5%, compared with DAT, at 88.9%. CONCLUSIONS : This study recommends rA2-ELISA as a parallel assay combined with DAT to detect VL infection among dogs. Further evaluations should be performed to develop an inexpensive and reliable serologic test for the detection of Leishmania infantum among infected dogs.
Resumo:
We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
Resumo:
The direct agglutination test (DAT) based on a freeze-dried antigen and the rK39 dipstick test were evaluated for the sero-diagnosis of visceral leishmaniasis (VL). The sensitivity and specificity of both tests were determined using sera from confirmed VL patients (n = 21), healthy controls (n = 19) and from patients with other confirmed infectious diseases (n = 42). The DAT had a sensitivity and a specificity of 100%. The rK39 had a sensitivity of 85.7% and a specificity of 82%. Both tests were also used to screen blood samples of confirmed VL patients (n = 15) and serum samples of VL suspects (n = 61). The DAT found all blood samples of confirmed VL patients positive and tested 98.4% of the serum samples of the VL suspects positive. In contrast, rK39 detected in 9/15 blood samples (60%) antibodies against Leishmania chagasi and found 85.3% of the serum samples of the suspected patients positive. Although the rK39 dipstick is more rapid and user friendlier than the DAT, the latter has a superior sensitivity and specificity. Furthermore, the reagents used for DAT do not require cold storage, whereas the buffer of the rK39 must be stored at 4ºC. Therefore, the DAT is the most suitable test for the sero-diagnosis of VL under field conditions.
Resumo:
BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.
Resumo:
INTRODUCTION Proteinuria (PTU) is an important marker for the development and progression of renal disease, cardiovascular disease and death, but there is limited information about the prevalence and factors associated with confirmed PTU in predominantly white European HIV+ persons, especially in those with an estimated glomerular filtration rate (eGFR) of 60 mL/min/1.73 m(2). PATIENTS AND METHODS Baseline was defined as the first of two consecutive dipstick urine protein (DPU) measurements during prospective follow-up >1/6/2011 (when systematic data collection began). PTU was defined as two consecutive DUP >1+ (>30 mg/dL) >3 months apart; persons with eGFR <60 at either DPU measurement were excluded. Logistic regression investigated factors associated with PTU. RESULTS A total of 1,640 persons were included, participants were mainly white (n=1,517, 92.5%), male (n=1296, 79.0%) and men having sex with men (n=809; 49.3%). Median age at baseline was 45 (IQR 37-52 years), and CD4 was 570 (IQR 406-760/mm(3)). The median baseline date was 2/12 (IQR 11/11-6/12), and median eGFR was 99 (IQR 88-109 mL/min/1.73 m(2)). Sixty-nine persons had PTU (4.2%, 95% CI 3.2-4.7%). Persons with diabetes had increased odds of PTU, as were those with a prior non-AIDS (1) or AIDS event and those with prior exposure to indinavir. Among females, those with a normal eGFR (>90) and those with prior abacavir use had lower odds of PTU (Figure 1). CONCLUSIONS One in 25 persons with eGFR>60 had confirmed proteinuria at baseline. Factors associated with PTU were similar to those associated with CKD. The lack of association with antiretrovirals, particularly tenofovir, may be due to the cross-sectional design of this study, and additional follow-up is required to address progression to PTU in those without PTU at baseline. It may also suggest other markers are needed to capture the deteriorating renal function associated with antiretrovirals may be needed at higher eGFRs. Our findings suggest PTU is an early marker for impaired renal function.
Resumo:
Proteinuria was associated with cardiovascular events and mortality in community-based cohorts. The association of proteinuria with mortality and cardiovascular events in patients undergoing percutaneous coronary intervention (PCI) was unknown. The association of urinary dipstick proteinuria with mortality and cardiovascular events (composite of death, myocardial infarction, or nonhemorrhagic stroke) in 5,835 subjects of the EXCITE trial was evaluated. Dipstick urinalysis was performed before PCI, and proteinuria was defined as trace or greater. Subjects were followed up for 210 days/7 months after enrollment for the occurrence of events. Multivariate Cox regression analysis evaluated the independent association of proteinuria with each outcome. Mean age was 59 years, 21% were women, 18% had diabetes mellitus, and mean estimated glomerular filtration rate was 90 ml/min/1.73 m(2). Proteinuria was present in 750 patients (13%). During follow-up, 22 subjects (2.9%) with proteinuria and 54 subjects (1.1%) without proteinuria died (adjusted hazard ratio 2.83, 95% confidence interval [CI] 1.65 to 4.84, p <0.001). The severity of proteinuria attenuated the strength of the association with mortality after PCI (low-grade proteinuria, hazard ratio 2.67, 95% CI 1.50 to 4.75; high-grade proteinuria, hazard ratio 3.76, 95% CI 1.24 to 11.37). No significant association was present for cardiovascular events during the relatively short follow-up, but high-grade proteinuria tended toward increased risk of cardiovascular events (hazard ratio 1.45, 95% CI 0.81 to 2.61). In conclusion, proteinuria was strongly and independently associated with mortality in patients undergoing PCI. These data suggest that such a relatively simple and clinically easy to use tool as urinary dipstick may be useful to identify and treat patients at high risk of mortality at the time of PCI. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1151-1155)
Resumo:
Current visceral leishmaniasis (VL) control programs in Brazil include the infected dog elimination but, despite this strategy, the incidence of human VL is still increasing. One of the reasons is the long delay between sample collection, analysis, control implementation and the low sensitivity of diagnostic tests. Due to the high prevalence of asymptomatic dogs, the diagnosis of these animals is important considering their vector infection capacity. Hence, a rapid and accurate diagnosis of canine visceral leishmaniasis is essential for an efficient surveillance program. In this study we evaluated the performance of rK39 antigen in an immunochromatographic format to detect symptomatic and asymptomatic Leishmania chagasi infection in dogs and compared the results with those using a crude antigen ELISA. The sensitivity of rK39 dipstick and ELISA were 83% vs. 95%, respectively, while the specificity was both 100%. Our results also demonstrated that the dipstick test was able to detect infected dogs presenting different clinical forms. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.
Resumo:
HIV/AIDS-associated visceral leishmaniasis may display the characteristics of an aggressive disease or without specific symptoms at all, thus making diagnosis difficult. The present study describes the results of diagnostic tests applied to a series of suspected VL cases in HIV-infected/AIDS patients admitted in referral hospitals in Pernambuco, Brazil. From a total of 14 eligible patients with cytopenias and/or fever of an unknown etiology, and indication of bone marrow aspirate, 10 patients were selected for inclusion in the study. Diagnosis was confirmed by the following examinations: Leishmania detection in bone marrow aspirate, direct agglutination test, indirect immunofluorescence, rK39 dipstick test, polymerase chain reaction and latex agglutination test. Five out of the ten patients were diagnosed with co-infection. A positive direct agglutination test was recorded for all five co-infected patients, the Leishmania detection and latex agglutination tests were positive in four patients, the rK39 dipstick test in three, the indirect immunofluorescence in two and a positive polymerase chain reaction was recorded for one patient. This series of cases was the first to be conducted in Brazil using this set of tests in order to detect co-infection. However, no consensus has thus far been reached regarding the most appropriate examination for the screening and monitoring of this group of patients.
Resumo:
SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.
Resumo:
Os programas de controle da hanseníase se beneficiariam de um método fácil para estimar prevalência e avaliar o impacto das ações de controle na prevalência da doença. A determinação da soroprevalência de anticorpos contra PGL-I através de estudos com crianças em idade escolar foi sugerida como indicador útil da taxa de prevalência da hanseníase a nível municipal.Para investigar se a soropositividade estaria associada aos coeficientes de detecção da hanseníase e se poderia ser usada como indicador da prevalência em outras áreas, 7.073 crianças em três estados endêmicos de hanseníase no Brasil foram testadas. Resultados mostram uma considerável variação da distribuição de soropositividade nas comunidades, independente do número de casos de hanseníase detectados. A soroprevalência foi significativamente menor nos colégios. Nenhuma diferença na distribuição da soropositividade determinada por ELISA ou dipstick foi observada. Nenhuma correlação entre o coeficiente de detecção da hanseníase e soropositividade pôde ser estabelecida.