998 resultados para differential scanning calorimeters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glass transition temperature of spaghetti sample was measured by thermal and rheological methods as a function of water content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The output of a differential scanning fluorimetry (DSF) assay is a series of melt curves, which need to be interpreted to get value from the assay. An application that translates raw thermal melt curve data into more easily assimilated knowledge is described. This program, called “Meltdown,” conducts four main activities—control checks, curve normalization, outlier rejection, and melt temperature (Tm) estimation—and performs optimally in the presence of triplicate (or higher) sample data. The final output is a report that summarizes the results of a DSF experiment. The goal of Meltdown is not to replace human analysis of the raw fluorescence data but to provide a meaningful and comprehensive interpretation of the data to make this useful experimental technique accessible to inexperienced users, as well as providing a starting point for detailed analyses by more experienced users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differential scanning calorimetric studies on ammonium perchlorate have been carried out. The enthalpy values for the phase transition endotherm and the two exotherms have been reported in the present communication. A new method has been developed for the estimation of kinetic parameters from DSC the mograms. The values for activation energy as calculated by the above method for low temperature and high temperature exotherms are in close agreement with literature values. The present studies also confirm the presence of small exothermic peaks at the initial stages of high temperature exotherm. Explanation for the same has been given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments on Ge15Tc85-xSix glasses (2 <= x <= 12) using alternating differential scanning calorimetry (ADSC) indicate that these glasses exhibit one glass transition and two crystallization reactions upon heating. The glass transition temperature has been found to increase almost linearly with silicon content, in the entire composition tie-line. The first crystallization temperature (T-cl) exhibits an increase with silicon content for x<5; T-cl remains almost a constant in the composition range 5 < x <= 10 and it increases comparatively more sharply with silicon content thereafter. The specific heat change (Delta C-p) is found to decrease with an increase in silicon content, exhibiting a minimum at x=5 (average coordination number, (r) = 2.4); a continuous increase is seen in Delta C-p with silicon concentration above x = 5. The effects seen in the variation with composition of T-cl and Delta C-p at x=5, are the specific signatures of the mean-field stiffness threshold at (r) = 2.4. Furthermore, a broad trough is seen in the enthalpy change (Delta H-NR), which is indicative of a thermally reversing window in Ge15Te85-xSix glasses in the composition range 2 <= x <= 6 (2.34 <= (r) <= 2.42).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differential scanning calorimetry (DSC) can be used for obtaining various non-isothermal properties of glassy materials. The thermal properties of the Si-As-Te glass system are discussed in relation to the interesting information obtained on the local ordering in these glasses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of the addition of p-aminophenol and aniline-based epoxy diluents on the curing behavior of highly viscous tetraglycidyl diamino diphenyl methane resin with diamino diphenyl sulfone hardener have been investigated kinetically by differential scanning calorimetry. Dynamic scans were carried out over a temperature range 30–300°C for different resin formulations. Isothermal scans at four differnt temperatures have also been carried out for the evaluation of kinetic parameters. Heat flow measurements at different heating rates have indicated the evidence of autocatalytic behavior of curing reaction following a simple nth-order kinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments on Ge15Te85− x Si x glasses (2 ≤ x ≤ 12) using alternating differential scanning calorimetry (ADSC) indicate that these glasses exhibit one glass transition and two crystallization reactions upon heating. The glass transition temperature has been found to increase almost linearly with silicon content, in the entire composition tie-line. The first crystallization temperature (T c1) exhibits an increase with silicon content for x < 5; T c1 remains almost a constant in the composition range 5 < x ≤ 10 and it increases comparatively more sharply with silicon content thereafter. The specific heat change (ΔC p) is found to decrease with an increase in silicon content, exhibiting a minimum at x = 5 (average coordination number, r = 2.4); a continuous increase is seen in ΔC p with silicon concentration above x = 5. The effects seen in the variation with composition of T c1 and ΔC p at x = 5, are the specific signatures of the mean-field stiffness threshold at r = 2.4. Furthermore, a broad trough is seen in the enthalpy change (ΔH NR), which is indicative of a thermally reversing window in Ge15Te85− x Si x glasses in the composition range 2 ≤ x ≤ 6 (2.34 ≤ r ≤ 2.42).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effectiveness of different routes of equal channel angular pressing (A, B-c, and C) is studied for commercially pure copper. The stored energy and the activation energy of recrystallization for the deformed samples were quantified using differential scanning calorimetry and X-ray diffraction line profile analysis. Results of the study revealed that the dislocation density and the stored energy are higher in the case of route B-c deformed sample. The activation energy for recrystallization is lower for route B-c. (C) 2012 International Centre for Diffraction Data doi:10.1017/S0885715612000310]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The melting behavior of poly(methyl methacrylate)-grafted nascent polyethylene reactor powder by plasma irradiation was studied by differential scanning calorimetry (DSC). The grafting yield ranged hom 11 to 190%. Grafting was found to lower both melting point and heat of fusion during the first run of DSC determination. The heat of fusion was used to calculate the apparent grafting yield of the samples. There was little strain induced by plasma-irradiated grafting on the surface of the polyethylene crystals. A method to determine the covalent grafting yield in the graft copolymer systems was developed. (C) 1995 John Wiley & Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The crystallinity of two series of uniform oligo(oxyethylene) mono-n-alkyl ethers has been investigated: alpha-alkyl,omega-hydroxyoligo(oxyethylene)s, H(CH2)n(OCH2CH2)mOH, and alpha-alkyl,omega-methoxyoligo(oxyethylene)s, H(CH2)n(OCH2CH2)mOCH3. The hydroxy-ended oligomers formed bilayer crystals, and the methoxy-ended oligomers formed monolayer crystals. The helical oxyethylene blocks were oriented normal to the layer-crystal end-group plane, whilst the trans-planar alkyl blocks were generally tilted at an angle delta = 60-degrees. The melting temperature and enthalpy of fusion were higher for hydroxy-ended oligomers than for corresponding methoxy-ended oligomers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

All biological phenomena depend on molecular recognition, which is either intermolecular like in ligand binding to a macromolecule or intramolecular like in protein folding. As a result, understanding the relationship between the structure of proteins and the energetics of their stability and binding with others (bio)molecules is a very interesting point in biochemistry and biotechnology. It is essential to the engineering of stable proteins and to the structure-based design of pharmaceutical ligands. The parameter generally used to characterize the stability of a system (the folded and unfolded state of the protein for example) is the equilibrium constant (K) or the free energy (deltaG(o)), which is the sum of enthalpic (deltaH(o)) and entropic (deltaS(o)) terms. These parameters are temperature dependent through the heat capacity change (deltaCp). The thermodynamic parameters deltaH(o) and deltaCp can be derived from spectroscopic experiments, using the van't Hoff method, or measured directly using calorimetry. Along with isothermal titration calorimetry (ITC), differential scanning calorimetry (DSC) is a powerful method, less described than ITC, for measuring directly the thermodynamic parameters which characterize biomolecules. In this article, we summarize the principal thermodynamics parameters, describe the DSC approach and review some systems to which it has been applied. DSC is much used for the study of the stability and the folding of biomolecules, but it can also be applied in order to understand biomolecular interactions and can thus be an interesting technique in the process of drug design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To examine the thermal transition(s) between different polymorphic forms of Nifedipine and to define experimental conditions that lead to the generation of polymorph IV. Methods. Experiments were performed using a DSC 823e (Mettler Toledo). Nifedipine exists in four polymorphic forms, as well as an amorphous state. Examination of Nifedipine was conducted using the following method(s): cycle 1: 25ºC to 190ºC, 190ºC to 25ºC (formation of amorphous Nifedipine); cycle 2: 25ºC to X (60,70,80...150ºC), X to 25ºC; cycle 3: 25ºC to 190ºC and holding isothermally for 5 min between cycles (heating/cooling rate of 10ºC/min). Results. The amorphous state Nifedipine can sustain heating up to 90ºC without significant changes in its composition. Cycle 2 of amorphous material heated up to 90ºC shows only the glass transition at ~44ºC. In cycle 3 of the same material, a glass transition has been recorded at ~44ºC, followed by two exotherms (~100 and ~115ºC (crystallisation of polymorph III and II, respectively) and an endotherm (169ºC (melting of polymorphs I/II)). Samples that have been heated to temperatures between 100ºC and 120ºC in the second cycle showed a glass transition at ~44ºC and an additional exotherm at ~95ºC (crystallisation of polymorph III) on cooling a exotherm was observed at ~40ºC (crystallisation of polymorph IV). The same material showed no glass transition in cycle 3 but an endotherm at around 62ºC (melting of polymorph IV) an exotherm (~98ºC) and an endotherm (169ºC) melting of polymorph I/II. Heating the sample to a temperatures greater than 130ºC in cycle two results in a glass transition at ~44ºC, and two exotherms at ~102 and 125ºC (crystallisation of polymorphs III and I, respectively). Conclusions. DSC data suggests that polymorph IV can only be produced from amorphous or polymorph III samples. The presence of polymorph I or II drives the conversion of the less stable polymorphic form IV into the most stable form, I. Although form IV of Nifedipine can easily be created, following defined experimental conditions, it may only coexist with amorphous or polymorph III states. When polymorphs I and II are present in the sample polymorph IV cannot be etected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To study thermal stability of Aspirin and define thermal events that are associated with the thermal degradation of aspirin. Methods. Experiments were performed using a DSC 823e (Mettler Toledo, Swiss). Aspirin is prone to thermal degradation upon exposure to high temperatures. The melting point of aspirin is 140.1±0.4ºC (DSC). Aspirin has been examined by heating samples to 120ºC, 155ºC and 185ºC with subsequent cooling to -55ºC and a final heating to 155ºC. Although different heating and cooling ranges have been used, only results obtained at a rate of 10ºC/min will be presented. All runs where conducted in hermetically sealed pans. Results. Upon heating the sample to 120ºC no significant thermal event can be detected. After cooling the sample and reheating a glass transition can be observed at ~-8ºC, followed by the melting of aspirin at ~139ºC. By heating the sample to 155ºC melting of aspirin has been detected at ~139ºC. On cooling and subsequent heating a glass transition occurs at ~-32ºC, together with a broad crystallisation (onset at ~38ºC and peak maximum at ~57ºC) followed by a broad melting with an onset at 94ºC and peak maximum at ~112ºC. Finally, by heating the sample to 185ºC melting at ~ 139ºC was observed, and upon cooling and reheating a glass transition was detected at ~-26ºC and no further events could be recorded. Conclusions. This research demonstrates that the degradation steps of Aspirin depend on the thermal treatment. The main degradation products of different thermal treatments are currently unknown it is clear that acetic acid, which is one of the degradation products, acts as an antiplasticiser by lowering the glass transition temperature. In addition, due to the presence of the degradation products in liquid form (observed by hot stage microscopy), Aspirin is still present in the sample and recrystallises during the second heating step and melts at much lower temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subambient behavior of aqueous mannitol solutions is of considerable relevance to the preparation of freeze dried formulations. In this investigation the properties of 3% w/v mannitol solutions were investigated using differential scanning calorimetry (DSC), cold stage microscopy (CSM), and X-ray diffraction (XRD) to identify the thermal transitions and structural transformations undergone by this system. It was found that on cooling from ambient the system formed ice at circa -20°C while a further exotherm was seen at approximately -30°C. Upon reheating an endotherm was seen at circa -30°C followed immediately by an exotherm at circa -25°C. Temperature cycling indicated that the thermal transitions observed upon reheating were not reversible. Modulated temperature DSC (MTDSC) indicated that the transitions observed upon reheating corresponded to a glass transition immediately followed by recrystallization, XRD data showed that recrystallization was into the ß form. Annealing at -35°C for 40 min prior to cooling and reheating resulted in a maximum enthalpy being observed for the reheating exotherm. It is concluded that on cooling 3% w/v aqueous mannitol solutions an amorphous phase is formed that subsequently recrystallises into the ß form. The study has also shown that DSC, CSM, and XRD are useful complementary techniques for the study of frozen systems