915 resultados para dialysis fluid
Resumo:
The process of on-line generation of ultrapure dialysis fluid is a core prerequisite for the safe execution of modern renal replacement therapies such as on-line hemodiafiltration and high-flux hemodialysis. In these extracorporeal treatments with variable degrees of convection, significant volumes of plasma water are removed and replaced with dialysis fluid, which must occur without causing harm to the patient. Historically, on-line generation of sterile and pyrogen-free physiological substitution fluid by the process of membrane ultrafiltration of fresh dialysis fluid has its origin in hemofiltration, a purely convective therapy. Development of this and later therapies is described in the historical context of a successful effort over decades to overcome the above formidable challenge, which was provided jointly by pioneering clinical investigators and a resourceful dialysis industry.
Resumo:
This paper reports a case of peritonitis by Nocardia asteroides during continuous ambulatory peritoneal dialysis in a man who had systemic lupus erythematous and chronic renal failure. Diagnosis was established by microscopic examination (Gram and Kinyoun) and culture of centrifuged dialysis fluid and the patient was treated with Trimethoprin-Sulfamethoxazole by intraperitoneal route.
Resumo:
Introduction: Continuous exposition of the peritoneal membrane to conventional dialysis solutions is an important risk factor for inducing structural and functional alterations. Objective: To compare in vitro mouse fibroblast NIH-3T3 cell viability after exposition to a neutral pH dialysis solution in comparison to cells exposed to a standard solution. Methods: Experimental study to compare the effects of a conventional standard or a neutral-pH, low-glucose degradation products peritoneal dialysis solution on the viability of exposed fibroblasts in cell culture. Both solutions were tested in all the commercially available glucose concentrations. Cell viability was evaluated with tetrazolium salt colorimetric assay. Results: Fibroblast viability was significantly superior in the neutral pH solution in comparison to control, in all three glucose concentrations (Optical density in nm-means ± SD: 1.5% 0.295 ± 0.047 vs. 0.372 ± 0.042, p < 0.001; 2.3% 0.270 ± 0.036 vs. 0.337 ± 0.051, p < 0.001; 4.25% 0.284 ± 0.037 vs. 0.332 ± 0.032, p < 0.001; control vs. neutral pH respectively, Student t Test). There was no significant difference in cell viability between the three concentrations of glucose when standard solution was used (ANOVA p = 0.218), although cell viability was higher after exposition to neutral pH peritoneal dialysis fluid at 1.5% in comparison to 2.3 and 4.25% glucose concentrations (ANOVA p = 0.008: Bonferroni 1.5% vs. 2.3% p = 0.033, 1.5% vs. 4.25% p = 0.014, 2.3% vs. 4.25% p = 1.00). Conclusion: Cell viability was better in neutral pH dialysis solution, especially in the lower glucose concentration. A more physiological pH and lower glucose degradation products may be responsible for such results.
Resumo:
The majority of severe hypersensitivity reactions in hemodialysis patients have occurred due to sensitization to ethylene oxide or to nonbiocompatible membrane dialyzers. The use of polysulfone dialyzers rarely causes hypersensitivity reactions. In the present study, we describe a case of severe life-threatening reactions induced by polysulfone dialyzers (from different manufacturers subjected to a variety of sterilization methods), which occurred after 9 sessions of hemodialysis with the same prescription, exemplifying the complexity of such reactions.
Resumo:
The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 µm-pore membranes; for mycobacteria, 0.45 µm pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.
Resumo:
BACKGROUND: In a previous study we demonstrated that mild metabolic alkalosis resulting from standard bicarbonate haemodialysis induces hypotension. In this study, we have further investigated the changes in systemic haemodynamics induced by bicarbonate and calcium, using non-invasive procedures. METHODS: In a randomized controlled trial with a single-blind, crossover design, we sequentially changed the dialysate bicarbonate and calcium concentrations (between 26 and 35 mmol/l for bicarbonate and either 1.25 or 1.50 mmol/l for calcium). Twenty-one patients were enrolled for a total of 756 dialysis sessions. Systemic haemodynamics was evaluated using pulse wave analysers. Bioimpedance and BNP were used to compare the fluid status pattern. RESULTS: The haemodynamic parameters and the pre-dialysis BNP using either a high calcium or bicarbonate concentration were as follows: systolic blood pressure (+5.6 and -4.7 mmHg; P < 0.05 for both), stroke volume (+12.3 and +5.2 ml; P < 0.05 and ns), peripheral resistances (-190 and -171 dyne s cm(-5); P < 0.05 for both), central augmentation index (+1.1% and -2.9%; ns and P < 0.05) and BNP (-5 and -170 ng/l; ns and P < 0.05). The need of staff intervention was similar in all modalities. CONCLUSIONS: Both high bicarbonate and calcium concentrations in the dialysate improve the haemodynamic pattern during dialysis. Bicarbonate reduces arterial stiffness and ameliorates the heart tolerance for volume overload in the interdialytic phase, whereas calcium directly increases stroke volume. The slight hypotensive effect of alkalaemia should motivate a probative reduction of bicarbonate concentration in dialysis fluid for haemodynamic reasons, only in the event of failure of classical tools to prevent intradialytic hypotension.
Resumo:
Aims: The aim of this study was to identify and determine the diversity, occurrence and distribution of fungi in water used at a haemodialysis centre.Methods and Results: Samples in the hydraulic circuit for the distribution of the water, dialysate samples and samples of sterilization solution from dialysers were collected over a 3-month period, and 500 ml of each sample was filtered through membranes. All together 116 isolates of fungi were recovered from 89% of all water samples collected inside the haemodialysis unit, with prevalence of moulds in tap water samples and of yeasts in dialysate samples. Fusarium spp. was the most abundant genus found, whereas Candida parapsilosis was the predominant yeast species.Conclusions: This study demonstrated that various fungi were present in the water system. These data suggest the inclusion of the detection and quantification of fungi in the water of haemodialysis.Significance and Impact of the Study: The recovery of fungi from aqueous haemodialysis environments implies a potential risk for haemodialysis patients and indicates the need for continuous maintenance and monitoring. Further studies on fungi in haemodialysis water systems are required to investigate the organism ability to persist, their role in biofilm formation and their clinical significance.
Resumo:
The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 mu m-pore membranes; for mycobacteria, 0.45 mu m pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.
Resumo:
Accumulating evidence suggests an association between body volume overload and inflammation in chronic kidney diseases. The purpose of this study was to evaluate the effect of dialysate sodium concentration reduction on extracellular water volume, blood pressure (BP), and inflammatory state in hemodialysis (HD) patients. In this prospective controlled study, adult patients on HD for at least 90 days and those with C-reactive protein (CRP) levels ≥ 0.7 mg/dL were randomly allocated into two groups: group A, which included 29 patients treated with reduction of dialysate sodium concentration from 138 to 135 mEq/L; and group B, which included 23 HD patients not receiving dialysate sodium reduction (controls). Of these, 20 patients in group A and 18 in group B completed the protocol study. Inflammatory, biochemical, hematological, and nutritional markers were assessed at baseline and after 8 and 16 weeks. Baseline characteristics were not significantly different between the two groups. Group A showed a significant reduction in serum concentrations of tumor necrosis factor-α, and interleukin-6 over the study period, while the BP and extracellular water (ECW) did not change. In Group B, there were no changes in serum concentrations of inflammatory markers, BP, and ECW. Dialysate sodium reduction is associated with attenuation of the inflammatory state, without changes in the BP and ECW, suggesting inhibition of a salt-induced inflammatory response. Copyright © 2013 Informa Healthcare USA, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: There is no consensus on the optimal method to measure delivered dialysis dose in patients with acute kidney injury (AKI). The use of direct dialysate-side quantification of dose in preference to the use of formal blood-based urea kinetic modeling and simplified blood urea nitrogen (BUN) methods has been recommended for dose assessment in critically-ill patients with AKI. We evaluate six different blood-side and dialysate-side methods for dose quantification. Methods: We examined data from 52 critically-ill patients with AKI requiring dialysis. All patients were treated with pre-dilution CWHDF and regional citrate anticoagulation. Delivered dose was calculated using blood-side and dialysis-side kinetics. Filter function was assessed during the entire course of therapy by calculating BUN to dialysis fluid urea nitrogen (FUN) ratios q/12 hours. Results: Median daily treatment time was 1,413 min (1,260-1,440). The median observed effluent volume per treatment was 2,355 mL/h (2,060-2,863) (p<0.001). Urea mass removal rate was 13.0 +/- 7.6 mg/min. Both EKR (r(2)=0.250; p<0.001) and K-D (r(2)=0.409; p<0.001) showed a good correlation with actual solute removal. EKR and K-D presented a decline in their values that was related to the decrease in filter function assessed by the FUN/BUN ratio. Conclusions: Effluent rate (ml/kg/h) can only empirically provide an estimated of dose in CRRT. For clinical practice, we recommend that the delivered dose should be measured and expressed as K-D. EKR also constitutes a good method for dose comparisons over time and across modalities.
Resumo:
Dialysate regeneration by sorbents is an alternative to conventional single-pass dialysis. Little is known about the capacity of sorbents to clear dialysate of “middle molecules” and protein-bound uremic toxins. We studied p-cresol sulfate (PCS) and β-2-microglobulin (β2M) removal from dialysate by a sorbent: 1. PCS (40 mg PCS dissolved in 4 L of fresh dialysate) was recirculated through a sorbent cartridge (SORB Technology, Inc.) for analysis of PCS removal. 2. Spent peritoneal dialysate was recirculated on the “blood” side of a high-flux dialyzer. On the “dialysate” side of the membrane, bicarbonate dialysate was recirculated through a sorbent cartridge. β2M was measured in both streams. Two results are of particular importance for the use of regenerated fluid in chronic dialysis: 1. PCS was virtually completely removed from the dialysate. On average, PCS concentration was reduced to 1.4% of the starting concentration after 60 minutes. PCS extraction across the sorbent was nearly complete at any time. 2. β2M was on average reduced to 14.3% of the starting concentration after 60 minutes. Postsorbent concentrations were consistently below the validated range of the test method. We conclude that PCS and β2M are efficiently removed from the dialysate by commercially available sorbent technology. Spent peritoneal dialysis fluid can be cleared of β2M when circulated against sorbent-regenerated dialysate using a high-flux membrane.
Resumo:
Background Icodextrin is a high molecular weight, starch-derived glucose polymer, which is capable of inducing sustained ultrafiltration over prolonged (12–16 hour) peritoneal dialysis (PD) dwells. The aim of this study was to evaluate the ability of icodextrin to alleviate refractory, symptomatic fluid overload and prolong technique survival in PD patients. Methods A prospective, open-label, pre-test/post-test study was conducted in 17 PD patients (8 females/9 males, mean age 56.8 ± 2.9 years) who were on the verge of being transferred to haemodialysis because of symptomatic fluid retention that was refractory to fluid restriction, loop diuretic therapy, hypertonic glucose exchanges and dwell time optimisation. One icodextrin exchange (2.5 L 7.5%, 12-hour dwell) was substituted for a long-dwell glucose exchange each day. Results Icodextrin significantly increased peritoneal ultrafiltration (885 ± 210 ml to 1454 ± 215 ml, p < 0.05) and reduced mean arterial pressure (106 ± 4 to 96 ± 4 mmHg, p < 0.05), but did not affect weight, plasma albumin concentration, haemoglobin levels or dialysate:plasma creatinine ratio. Diabetic patients (n = 12) also experienced improved glycaemic control (haemoglobin Alc decreased from 8.9 ± 0.7% to 7.9 ± 0.7%, p < 0.05). Overall PD technique survival was prolonged by a mean of 11.6 months (95% CI 6.0–17.3 months). On multivariate Cox proportional hazards analysis, extension of technique survival by icodextrin was only significantly predicted by baseline net daily peritoneal ultrafiltration (adjusted HR 2.52, 95% CI 1.13–5.62, p < 0.05). Conclusions Icodextrin significantly improved peritoneal ultrafiltration and extended technique survival in PD patients with symptomatic fluid overload, especially those who had substantially impaired peritoneal ultrafiltration.
Resumo:
Intermittent hemodialysis (IHD) and continuous renal replacement therapies (CRRT) are used as Acute Kidney Injury (AKI) therapy and have certain advantages and disadvantages. Extended daily dialysis (EDD) has emerged as an alternative to CRRT in the management of hemodynamically unstable AKI patients, mainly in developed countries.Objectives: We hypothesized that EDD is a safe option for AKI treatment and aimed to describe metabolic and fluid control of AKI patients undergoing EDD and identify complications and risk factors associated with death.Study Selection: This is an observational and retrospective study describing introduction of EDD at our institution. A total of 231 hemodynamically unstable AKI patients (noradrenalin dose between 0.3 and 1.0 ucg/kg/min) were assigned to 1367 EDD session. EDD consisted of 6-8 h of HD 6 days a week, with blood flow of 200 ml/min, dialysate flows of 300 ml/min.Data Synthesis: Mean age was 60.6 +/- 15.8 years, 97.4% of patients were in the intensive care unit, and sepsis was the main etiology of AKI (76.2). BUN and creatinine levels stabilized after four sessions at around 38 and 2.4 mg/dl, respectively. Fluid balance decreased progressively and stabilized around zero after five sessions. Weekly delivered Kt/V was 5.94 +/- 0.7. Hypotension and filter clotting occurred in 47.5 and 12.4% of treatment session, respectively. Regarding AKI outcome, 22.5% of patients presented renal function recovery, 5.6% of patients remained on dialysis after 30 days, and 71.9% of patients died. Age and focus abdominal sepsis were identified as risk factors for death. Urine output and negative fluid balance were identified as protective factors.Conclusions: EDD is effective for AKI patients, allowing adequate metabolic and fluid control. Age, focus abdominal sepsis, and lower urine output as well as positive fluid balance after two EDD sessions were associated significantly with death.