987 resultados para device-free


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel device-free stationary person detection and ranging method, that is applicable to ultra-wide bandwidth (UWB) networks. The method utilizes a fixed UWB infrastructure and does not require a training database of template waveforms. Instead, the method capitalizes on the fact that a human presence induces small low-frequency variations that stand out against the background signal, which is mainly affected by wideband noise. We analyze the detection probability, and validate our findings with numerical simulations and experiments with off-the-shelf UWB transceivers in an indoor environment. © 2007-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Passive person detection and localization is an emerging area in UWB localization systems, whereby people are not required to carry any UWB ranging device. Based on experimental data, we propose a novel method to detect static persons in the absence of template waveforms, and to compute distances to these persons. Our method makes very little assumptions on the environment and can achieve ranging performances on the order of 50 cm, using off-the-shelf UWB devices. © 2013 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Having to carry input devices can be inconvenient when interacting with wall-sized, high-resolution tiled displays. Such displays are typically driven by a cluster of computers. Running existing games on a cluster is non-trivial, and the performance attained using software solutions like Chromium is not good enough. This paper presents a touch-free, multi-user, humancomputer interface for wall-sized displays that enables completely device-free interaction. The interface is built using 16 cameras and a cluster of computers, and is integrated with the games Quake 3 Arena (Q3A) and Homeworld. The two games were parallelized using two different approaches in order to run on a 7x4 tile, 21 megapixel display wall with good performance. The touch-free interface enables interaction with a latency of 116 ms, where 81 ms are due to the camera hardware. The rendering performance of the games is compared to their sequential counterparts running on the display wall using Chromium. Parallel Q3A’s framerate is an order of magnitude higher compared to using Chromium. The parallel version of Homeworld performed on par with the sequential, which did not run at all using Chromium. Informal use of the touch-free interface indicates that it works better for controlling Q3A than Homeworld.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The papers in this special issue focus on the topic of location awareness for radio and networks. Localization-awareness using radio signals stands to revolutionize the fields of navigation and communication engineering. It can be utilized to great effect in the next generation of cellular networks, mining applications, health-care monitoring, transportation and intelligent highways, multi-robot applications, first responders operations, military applications, factory automation, building and environmental controls, cognitive wireless networks, commercial and social network applications, and smart spaces. A multitude of technologies can be used in location-aware radios and networks, including GNSS, RFID, cellular, UWB, WLAN, Bluetooth, cooperative localization, indoor GPS, device-free localization, IR, Radar, and UHF. The performances of these technologies are measured by their accuracy, precision, complexity, robustness, scalability, and cost. Given the many application scenarios across different disciplines, there is a clear need for a broad, up-to-date and cogent treatment of radio-based location awareness. This special issue aims to provide a comprehensive overview of the state-of-the-art in technology, regulation, and theory. It also presents a holistic view of research challenges and opportunities in the emerging areas of localization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite significant investment in school one-to-one device programs, little is known about which aspects of program implementation work and why. Through a comparison of two implementation models, adopter-diffusion and saturation, and using existing data from the One Laptop per Child Australia laptop program, we explored how factors of implementation may affect device diffusion, learning and educational outcomes, and program sustainability in schools. In this article we argue that more focused research into implementation of one-to-one device programs, moving beyond comparisons of “devices versus without devices,” is needed to provide reliable data to inform future program funding and advance this area of research.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report the fabrication of free-standing flexible inorganic/organic hybrid structures by exfoliating ZnO nanostructured films from the flat indium tin oxide (ITO)/silicon/sapphire substrates using poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS). Strong interaction between ZnO and PEDOT: PSS and the thermomechanical response of PEDOT: PSS are the key issues for the exfoliation to prevail. The performance of the free-standing hybrid structures as rectifiers and photodetectors is better as compared to ITO supported hybrid structures. It is also shown that device properties of hybrid structures can be tuned by using different electrode materials. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.4729550]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To compare measures of fat-free mass (FFM) by three different bioelectrical impedance analysis (BIA) devices and to assess the agreement between three different equations validated in older adult and/or overweight populations. Design: Cross-sectional study. Setting: Orthopaedics ward of Brisbane public hospital, Australia. Participants: Twenty-two overweight, older Australians (72 yr ± 6.4, BMI 34 kg/m2 ± 5.5) with knee osteoarthritis. Measurements: Body composition was measured using three BIA devices: Tanita 300-GS (foot-to-foot), Impedimed DF50 (hand-to-foot) and Impedimed SFB7 (bioelectrical impedance spectroscopy (BIS)). Three equations for predicting FFM were selected based on their ability to be applied to an older adult and/ or overweight population. Impedance values were extracted from the hand-to-foot BIA device and included in the equations to estimate FFM. Results: The mean FFM measured by BIS (57.6 kg ± 9.1) differed significantly from those measured by foot-to-foot (54.6 kg ± 8.7) and hand-to-foot BIA (53.2 kg ± 10.5) (P < 0.001). The mean ± SD FFM predicted by three equations using raw data from hand-to-foot BIA were 54.7 kg ± 8.9, 54.7 kg ± 7.9 and 52.9 kg ± 11.05 respectively. These results did not differ from the FFM predicted by the hand-to-foot device (F = 2.66, P = 0.118). Conclusions: Our results suggest that foot-to-foot and hand-to-foot BIA may be used interchangeably in overweight older adults at the group level but due to the large limits of agreement may lead to unacceptable error in individuals. There was no difference between the three prediction equations however these results should be confirmed within a larger sample and against a reference standard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flexible multilayer electrodes that combine high transparency, high conductivity, and efficient charge extraction have been deposited, characterised and used as the anode in organic solar cells. The anode consists of an AZO/Ag/AZO stack plus a very thin oxide interlayer whose ionization potential is fine-tuned by manipulating its gap state density to optimise charge transfer with the bulk heterojunction active layer consisting of poly(n-3- hexylthiophene-2,5-diyl) and phenyl-C61-butyric acid methyl ester (P3HT:BC61BM). The deposition method for the stack was compatible with the low temperatures required for polymer substrates. Optimisation of the electrode stack was achieved by modelling the optical and electrical properties of the device and a power conversion efficiency of 2.9% under AM1.5 illumination compared to 3.0% with an ITO-only anode and 3.5% for an ITO:PEDOT electrode. Dark I-V reverse bias characteristics indicate very low densities of occupied buffer states close to the HOMO level of the hole conductor, despite observed ionization potential being high enough. Their elimination should raise efficiency to that with ITO:PEDOT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The “third-generation” 3D graphene structures, T-junction graphene micro-wells (T-GMWs) are produced on cheap polycrystalline Cu foils in a single-step, low-temperature (270 °C), energy-efficient, and environment-friendly dry plasma-enabled process. T-GMWs comprise vertical graphene (VG) petal-like sheets that seemlessly integrate with each other and the underlying horizontal graphene sheets by forming T-junctions. The microwells have the pico-to-femto-liter storage capacity and precipitate compartmentalized PBS crystals. The T-GMW films are transferred from the Cu substrates, without damage to the both, in de-ionized or tap water, at room temperature, and without commonly used sacrificial materials or hazardous chemicals. The Cu substrates are then re-used to produce similar-quality T-GMWs after a simple plasma conditioning. The isolated T-GMW films are transferred to diverse substrates and devices and show remarkable recovery of their electrical, optical, and hazardous NO2 gas sensing properties upon repeated bending (down to 1 mm radius) and release of flexible trasparent display plastic substrates. The plasma-enabled mechanism of T-GMW isolation in water is proposed and supported by the Cu plasma surface modification analysis. Our GMWs are suitable for various optoelectronic, sesning, energy, and biomedical applications while the growth approach is potentially scalable for future pilot-scale industrial production.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The existing internet computing resource, Biomolecules Segment Display Device (BSDD), has been updated with several additional useful features. An advanced option is provided to superpose the structural motifs obtained from a search on the Protein Data Bank (PDB) in order to see if the three-dimensional structures adopted by identical or similar sequence motifs are the same. Furthermore, the options to display structural aspects like inter- and intra-molecular interactions, ion-pairs, disulphide bonds, etc. have been provided.The updated resource is interfaced with an up-to-date copy of the public domain PDB as well as 25 and 90% non-redundant protein structures. Further, users can upload the three-dimensional atomic coordinates (PDB format) from the client machine. A free molecular graphics program, JMol, is interfaced with it to display the three-dimensional structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES Based on self-reported measures, sedentary time has been associated with chronic disease and mortality. This study examined the validity of the wrist-worn GENEactiv accelerometer for measuring sedentary time (i.e. sitting and lying) by posture classification, during waking hours in free living adults. DESIGN Fifty-seven participants (age=18-55 years 52% male) were recruited using convenience sampling from a large metropolitan Australian university. METHODS Participants wore a GENEActiv accelerometer on their non-dominant wrist and an activPAL device attached to their right thigh for 24-h (00:00 to 23:59:59). Pearson's Correlation Coefficient was used to examine the convergent validity of the GENEActiv and the activPAL for estimating total sedentary time during waking hours. Agreement was illustrated using Bland and Altman plots, and intra-individual agreement for posture was assessed with the Kappa statistic. RESULTS Estimates of average total sedentary time over 24-h were 623 (SD 103) min/day from the GENEActiv, and 626 (SD 123) min/day from the activPAL, with an Intraclass Correlation Coefficient of 0.80 (95% confidence intervals 0.68-0.88). Bland and Altman plots showed slight underestimation of mean total sedentary time for GENEActiv relative to activPAL (mean difference: -3.44min/day), with moderate limits of agreement (-144 to 137min/day). Mean Kappa for posture was 0.53 (SD 0.12), indicating moderate agreement for this sample at the individual level. CONCLUSIONS The estimation of sedentary time by posture classification of the wrist-worn GENEActiv accelerometer was comparable to the activPAL. The GENEActiv may provide an alternative, easy to wear device based measure for descriptive estimates of sedentary time in population samples

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blends of poly (ethylene-co-methacrylic acid) (PEMA) and poly (vinyl alcohol-co-ethylene) (EVOH) were studied for encapsulating Schottky structured organic devices. A calcium degradation test was used to determine water vapor transmission rates and to determine the moisture barrier performance of neat and blend films. Moisture barrier analysis for the neat and blend compositions was discussed concerning the interactions in the blend, diffusivity of water molecules through the unit cell systems, and the occupiable free volumes available in the unit cells using molecular dynamics simulations. The experimental results of water vapor permeation were correlated with diffusion behavior predicted from molecular dynamics simulations results. The effectiveness of the blend as a suitable barrier material in increasing the lifetime of an encapsulated Schottky structured organic device was determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transfer free processes using Cu films greatly simplify the fabrication of reliable suspended graphene devices. In this paper, the authors report on the use of electrodeposited Cu films on Si for transfer free fabrication of suspended graphene devices. The quality of graphene layers on optimized electrodeposited Cu and Cu foil are found to be the same. By selectively etching the underlying Cu, the authors have realized by a transfer free process metal contacted, suspended graphene beams up to 50 mu m in length directly on Si. The suspended graphene beams do not show any increase in defect levels over the as grown state indicating the efficiency of the transfer free process. Measured room temperature electronic mobilities of up to 5200 cm(2)/V.s show that this simpler and CMOS compatible route has the potential to replace the foil based route for such suspended nano and micro electromechanical device arrays. (C) 2014 American Vacuum Society.