1000 resultados para determinação simultânea


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The simultaneous determination of cobalt and nickel is a classical analytical problem. A great number of reagents associated with several techniques of analysis have been applied to achieve this determination. In this review 117 references, which appeared between 1996-1980, are described and classified according to the technique applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the analysis of cations by capillary electrophoresis is reviewed from the theoretical and practical point of view. Separation mechanisms and detection modes are discussed and illustrated. A thorough compilation of the literature over the last ten years, regarding applications of the technique to the analysis of cations in real matrices, is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Genetic algorithm was used for variable selection in simultaneous determination of mixtures of glucose, maltose and fructose by mid infrared spectroscopy. Different models, using partial least squares (PLS) and multiple linear regression (MLR) with and without data pre-processing, were used. Based on the results obtained, it was verified that a simpler model (multiple linear regression with variable selection by genetic algorithm) produces results comparable to more complex methods (partial least squares). The relative errors obtained for the best model was around 3% for the sugar determination, which is acceptable for this kind of determination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A very simple spectrophotometric method is described for resolving binary mixture of the food colorants Sunset Yellow (INS 110) and Tartrazine Yellow (INS 102) by using the first derivative spectra with measurements at zero-crossing wavelengths. Before the spectrophotometric measurements, the dyes were sorbed onto polyurethane foam and recovered in N,N-dimethilformamide. Commercial food products (gelatine and juice powder) were analysed by using the proposed method and the HPLC technique. The results are in very good agreement and the differences between the methods is not statistically important. Therefore, the first-order derivative spectrophotometric method is accurate, precise, reliable and could be applied to the routine analysis of food samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A micellar electrokinetic chromatographic method (MEKC) is described for determining residues of amphenicols(chloramphenicol,thiamphenicol and florfenicol) in bovine milk. MEKC is conducted by using a separation buffer consisting of 20 mM Na2HPO4, 10 mM Na2B4O7, 50 mM SDS at pH 8.0; UV detection at 210 nm and 10 kV of voltage. The limit of detection ranged from 4.3-5.3 µg L-1. The MEKC method was applied for the simultaneous determination of amphenicols in milk samples spiked with amphenicols at three concentration levels: 10, 30 and 50 µg L-1. Recoveries ranging from 91-105% were obtained by following a simple extraction/preconcentration procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the quantitation of lamivudine, zidovudine and nevirapine in the fixed-dose combination film-coated tablet by high performance liquid chromatography, in accordance with RE No. 899/2003, National Sanitary Surveillance Agency. It was based on an isocratic elution system with a potassium phosphate buffer pH 3.0: acetonitrile (60:40 v/v) mobile phase, C18, 250 x 46 mm column, 10µm particle size, λ 270 nm. The statistically evaluated results have shown that the method is specific, precise, accurate, and robust, ensuring the analytical safety of 3TC, AZT and NVP determination, which emerges as a new therapeutic alternative for antiretroviral treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was determining the main organic acids in pulp and juices, as well as evaluating their stability, after opening the package, by liquid chromatography in a C18 column with isocratic elution and UV detection. In açaí pulp tartaric, malic and citric acids were found. Cashew samples presented all of the organic acids evaluated, besides high concentrations of ascorbic and malic acids. Acerola pulp had the highest ascorbic acid concentration. A small decrease in organic acid content during storage was observed. Malic and citric acids seem to be more stable than tartaric and ascorbic acids.