201 resultados para depiction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morgan, Huw, Habbal, S.R., Woo, R., (2006) 'The Depiction of Coronal Structure in White-Light Images', Solar Physics 236(2) pp.263-272 RAE2008

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The space of the prison is no longer on the margins in relation to societal `centres', but instead acts as an adjunct to the urban environment. With the disappearance of the Gothic prison from the archi-texture of contemporary cities, the meaning conveyed by its façade has lost much of its potency. It is now contemporary prison drama, as opposed to the physical façade, that represents the interface between the public and the prison. This article explores a dramatic representation of the prison (The Shawshank Redemption) through the lens of Freud's (1919/1955) notion of the uncanny and Bachelard's (1958/1994) poetics of domestic space. Incarceration, as depicted in film and television, reinforces the `place myths' of the prison (Shields, 1991). Contemporary prison drama portrays the prison as a marginal space in much the way that the Gothic façades of the 19th-century prison projected a particular message. The prison, as depicted on screen, is a simulacrum. It is a facsimile of an architectural idea that only ever existed as a façade - a façade that occluded as much as it projected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radiological depiction of stab wounds in soft-tissues using multislice computed tomography is difficult and the hereby obtained images often lack contrast. To overcome these shortcomings we tried a new method. We gently instilled the contrast medium Lipiodol((R)) Ultra-fluide into five experimentally induced stab wounds on a pork haunch. Subsequent MSCT reconstructions of the wounds delivered clear, for medical laymen easily appreciable images regarding the stab direction and the stab depth. We believe that this easy and rapid technique can be useful in the examination of stab wounds in living and dead victims of sharp trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent development of ultrasonographic equipment has allowed improved spatial resolution for visualizing normal and pathologic conditions of peripheral nerves. Regarding the brachial plexus, only ultrasonographic studies that have described the normal appearance have been reported. To the best of our knowledge, no case report regarding the ultrasonographic description of a brachial plexus lesion has been published. We report the ultrasonographic findings of a brachial plexus injury after extirpation of a suspected enlarged supraclavicular lymph node.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to delineate the anatomy of the precentral cerebellar vein, superior vermian vein, and internal occipital vein using reconstructions of computed tomographic and magnetic resonance imaging scans with navigation software. These data were compared with previous anatomic and angiographic findings to show the resolution and accuracy of the system. METHODS: We retrospectively reviewed 100 patients with intracranial pathologies (50 computed tomographic scans with contrast and 50 magnetic resonance imaging scans with gadolinium) using a neuronavigation workstation for 3-dimensional reconstruction. Particular attention was paid to depiction of the precentral cerebellar vein, superior vermian vein, and internal occipital vein. The data were reviewed and analyzed. RESULTS: The precentral cerebellar vein, superior vermian vein, and its tributary, the supraculminate vein, were depicted in 52 (52%) patients. The internal occipital vein was delineated on 99 (49.5%) sides and joined the basal vein and vein of Galen in 39 (39.4%) and 60 (60.6%) hemispheres, respectively. Comparing these results with previous angiographic studies, the ability of the neuronavigation system for depicting these vessels is similar to that of digital subtraction angiography. CONCLUSION: This study illustrates the possibility of depicting the small vessels draining into the pineal region venous complex using 3-dimensional neuronavigation with an accuracy comparable to that of digital subtraction angiography. This tool provides important information for both surgical planning and intraoperative orientation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Instillation of contrast medium into stab wounds has shown promising results regarding visibility and assessment of general stab direction with computed tomography. However, the accuracy of this method--and, incidentally also probing of stab wounds--has to our knowledge not previously been examined. Also the effect of bluntness of different stabbing objects on the examination of stab wounds was not considered before this study. METHODS Using a pocket-knife, a steak-knife, and a Phillips screwdriver, nine stab wounds each were inflicted to three pork haunches. The depths of the stab wounds were determined by probing and multislice computed tomography (MSCT) after instillation of a contrast medium (CM) and then compared to those observed by dissection, our internal "gold standard". RESULTS In stab wounds inflicted by knives, MSCT-CM and probing provided results which differed by roughly 10-11% from the dissection results. In screwdriver stabs MSCT-CM showed a deviation of almost 30%, probing over 33%. DISCUSSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate. CONCLUSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This atlas presents a comprehensive set of maps depicting a wide range of socioeconomic aspects of the population of Vietnam. All the maps based on sensus statistics included in this atlas are available at the commune level, which gives a very detailed picture of spatial patterns in population, education, and living conditions.