A 300-strong Angus-Brahman cattle herd near Springsure, central Queensland, was being fed Acacia shirleyi (lancewood) browse during drought and crossed a 5-hectare, previously burnt area with an almost pure growth of Dysphania glomulifera subspecies glomulifera (red crumbweed) on their way to drinking water. Forty cows died of cyanide poisoning over 2 days before further access to the plant was prevented. A digital image of a plant specimen made on a flat-bed scanner and transmitted by email was used to identify D glomulifera. Specific advice on the plant's poisonous properties and management of the case was then provided by email within 2 hours of an initial telephone call by the field veterinarian to the laboratory some 600 km away. The conventional method using physical transport of a pressed dried plant specimen to confirm the identification took 5 days. D glomulifera was identified in the rumen of one of two cows necropsied. The cyanogenic potential of D glomulifera measured 4 days after collection from the site of cattle deaths was 18,600 mg HCN/kg in dry matter. The lethal dose of D glomulifera for a 420 kg cow was estimated as 150 to 190 g wet weight. The plant also contained 4.8% KNO3 equivalent in dry matter, but nitrate-nitrite poisoning was not involved in the deaths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sodium cyanide poison is potentially a more humane method to control wild dogs than sodium fluoroacetate (1080) poison. This study quantified the clinical signs and duration of cyanide toxicosis delivered by the M-44 ejector. The device delivered a nominal 0.88 g of sodium cyanide, which caused the animal to loose the menace reflex in a mean of 43 s, and the animal was assumed to have undergone cerebral hypoxia after the last visible breath. The mean time to cerebral hypoxia was 156 s for a vertical pull and 434 s for a side pull. The difference was possibly because some cyanide may be lost in a side pull. There were three distinct phases of cyanide toxicosis: the initial phase was characterised by head shaking, panting and salivation; the immobilisation phase by incontinence, ataxia and loss of the righting reflex; and the cerebral hypoxia phase by a tetanic seizure. Clinical signs that were exhibited in more than one phase of cyanide toxicosis included retching, agonal breathing, vocalisation, vomiting, altered levels of ocular reflex, leg paddling, tonic muscular spasms, respiratory distress and muscle fasciculations of the muzzle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides an overview of a series of pig- and fox-baiting research projects conducted 2005–2010. It is intended to collate and summarise the outcomes of these unpublished projects, including the completed pen and field trials, and provide recommendations for future research. This review will provide a useful reference document to support further research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen cyanide (HCN) is a toxic chemical that can potentially cause mild to severe reactions in animals when grazing forage sorghum. Developing technologies to monitor the level of HCN in the growing crop would benefit graziers, so that they can move cattle into paddocks with acceptable levels of HCN. In this study, we developed near-infrared spectroscopy (MRS) calibrations to estimate HCN in forage sorghum and hay. The full spectral NIRS range (400-2498 nm) was used as well as specific spectral ranges within the full spectral range, i.e., visible (400-750 nm), shortwave (800-1100 nm) and near-infrared (NIR) (1100-2498 nm). Using the full spectrum approach and partial least-squares (PLS), the calibration produced a coefficient of determination (R-2) = 0.838 and standard error of cross-validation (SECV) = 0.040%, while the validation set had a R-2 = 0.824 with a low standard error of prediction (SEP = 0.047%). When using a multiple linear regression (MLR) approach, the best model (NIR spectra) produced a R-2 = 0.847 and standard error of calibration (SEC) = 0.050% and a R-2 = 0.829 and SEP = 0.057% for the validation set. The MLR models built from these spectral regions all used nine wavelengths. Two specific wavelengths 2034 and 2458 nm were of interest, with the former associated with C=O carbonyl stretch and the latter associated with C-N-C stretching. The most accurate PLS and MLR models produced a ratio of standard error of prediction to standard deviation of 3.4 and 3.0, respectively, suggesting that the calibrations could be used for screening breeding material. The results indicated that it should be feasible to develop calibrations using PLS or MLR models for a number of users, including breeding programs to screen for genotypes with low HCN, as well as graziers to monitor crop status to help with grazing efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel chromogenic thiourea based sensors 4,4'-bis-[3-(4-nitrophenyl) thiourea] diphenyl ether 1 and 4,4'-bis-[3-(4-nitrophenyl) thiourea] diphenyl methane 2 having nitrophenyl group as signaling unit have been synthesized and characterized by spectroscopic techniques and X-ray crystallography. The both sensors show visual detection, UV-vis and NMR spectral changes in presence of fluoride and cyanide anions in organic solvent as well as in aqueous medium. The absorption spectra indicated the formation of complex between host and guest is in 1:2 stoichiometric ratios. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Addition of hydrogen cyanide to 9-methyl-Δ4-octalone-3 (IIb), as a model, yielded both cis- and trans-ketonitriles the configurations of which are assigned on the basis of IR spectra of the hydrolysed products. Similar addition of hydrogen cyanide to 9β-methyl-8β-hydroxy-Δ4-octalone-3 (IIc) gave the corresponding cis- and trans-hydroxy-keto-nitriles, configurations of which were proved by their conversion into cis- and trans-keto-nitriles obtained in the model study. In contrast to the model experiment where the trans-product predominated, the cis-isomer was the major product of addition to IIc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ab initio molecular orbital (MO) calculations with the 3-21G and 6-31G basis sets were performed on a series of ion-molecule and ion pair-molecule complexes for the H2O + LiCN system. Stabilisation energies (with counter-poise corrections), geometrical parameters, internal force constants and harmonic vibrational frequencies were evaluated for 16 structures of interest. Although the interaction energies are smaller, the geometries and relative stabilities of the monohydrated contact ion pair are reminiscent of those computed for the complexes of the individual ions. Thus, interaction of the oxygen lone pair with lithium leads to a highly stabilised C2v structure, while the coordination of water to the cyanide ion involves a slightly non-linear hydrogen bond. Symmetrical bifurcated structures are computed to be saddle points on the potential energy surface, and to have an imaginary frequency for the rocking mode of the water molecule. On optimisation the geometries of the solvent shared ion pair structures (e.g. Li+cdots, three dots, centered OH2cdots, three dots, centered CN−) revealed a proton transfer from the water molecule leading to hydrogen bonded forms such as Li-O-Hcdots, three dots, centered HCN. The variation in the force constants and harmonic frequencies in the various structures considered are discussed in terms of ion-molecular and ion pair-molecule interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Probes based on anthra[1,2-d]imidazole-6,11-dione were designed and synthesized for selective ion sensing. Each probe acted as strong colorimetric sensors for fluoride and cyanide ions and exhibited intramolecular charge transfer (ICT) band, which showed significant red-shifts after addition of either the F(-) or CN(-) ion. One of the probes (2) showed selective colorimetric sensing for both cyanide and fluoride ions. In organic medium, 2 showed selective color change with fluoride and cyanide, whereas in aqueous organic medium it showed a ratiometric response selectively for cyanide ion.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A waste fungal biomass containing killed cells of Aspergillus niger was efficiently used in the removal of toxic metal ions such as nickel, calcium, iron and chromium from aqueous solutions. The role of different parameters such as initial metal ion concentration, solution pH and biomass concentration on biosorption capacity was established. The maximum metal uptake was found to be dependent on solution pH and increased with biomass loading upto 10g/L. The adsorption densities for various metal ions could be arranged as Ca>Cr (III)>Ni>Fe>Cr (VI). The effect of the presence of various metal ions in binary, ternary and quaternary combinations on biosorption was also assessed. Ni uptake was significantly affected, while that of Cr (VI) the least, in the presence of other metal ions. Uptake of base metals from an industrial cyanide effluent was studied using different species of fungi such as Aspergillus niger, Aspergillus terreus and Penicillium funiculosum and yeast such as Saccharomyces cerevisiae which were isolated from a gold mine. Traces of gold present in the cyanide effluent could be efficiently recovered. Among the four base metal contaminants present in the cyanide effluent, zinc was found to be most efficiently biosorbed, followed by iron, copper and lead. The role of both living and dead biomass on biosorption was distinguished and probable mechanisms illustrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new bis-indolyl-based colorimetric probe has been synthesized. This allows a Michael-type adduct formation for the detection of cyanide ions. The probe shows a remarkable color change from red to colorless upon addition of the cyanide ions in pure water. The cyanide ion reacts with the probe and removes the conjugation of the bis-indolyl moiety of the probe with that of the 4-substituted aromatic ring. This renders the probe colorless. The mechanism of the reaction of the probe with the cyanide ion was established by using 1H and 13C NMR spectroscopy, mass spectrometry, and kinetic studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein we report the first applications of TCNQ as a rapid and highly sensitive off-the-shelf cyanide detector. As a proof-of-concept, we have applied a kinetically selective single-electron transfer (SET) from cyanide to deep-lying LUMO orbitals of TCNQ to generate a persistently stable radical anion (TCNQ(center dot-)), under ambient condition. In contrast to the known cyanide sensors that operate with limited signal outputs, TCNQ(center dot-) offers a unique multiple signaling platform. The signal readability is facilitated through multichannel absorption in the UV-vis-NIR region and scattering-based spectroscopic methods like Raman spectroscopy and hyper Rayleigh scattering techniques. Particularly notable is the application of the intense 840 nm NIR absorption band to detect cyanide. This can be useful for avoiding background interference in the UV-vis region predominant in biological samples. We also demonstrate the fabrication of a practical electronic device with TCNQ as a detector. The device generates multiorder enhancement in current with cyanide because of the formation of the conductive TCNQ(center dot-).