997 resultados para current facilities


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A current facilities management discourse seeks to discover how the built environment promotes or retards organisational change. However, whether or not significant change arises at all is yet to be definitively established. Hence, a contribution to the school of thought in this direction is considered important. This research investigated organisational performance relative to innovative work settings. The aim of the study was to determine whether organisational performance and, hence, change are indeed brought about by innovative work settings. A sample of 102 work settings was studied, and several null hypotheses on innovative work settings and organisational performance were tested using the Kruskal-Wallis H test. Although subtle shifts were observed in the aspects of organisational performance that seem predicated on innovative work settings, to some extent the proposition that the physical properties and design of the workplace can influence organisational performance was validated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context. Radiative transfer calculations have predicted intensity enhancements for optically thick emission lines, as opposed to the normal intensity reductions, for astrophysical plasmas under certain conditions. In particular, the results are predicted to be dependent both on the geometry of the emitting plasma and the orientation of the observer. Hence in principle the detection of intensity enhancement may provide a way of determining the geometry of an unresolved astronomical source.
Aims. To investigate such enhancements we have analysed a sample of active late-type stars observed in the far ultraviolet spectral region.
Methods. Emission lines of O vi in the FUSE satellite spectra of ϵ Eri, II Peg and Prox Cen were searched for intensity enhancements due to opacity.
Results. We have found strong evidence for line intensity enhancements due to opacity during active or flare-like activity for all three stars. The O vi 1032/1038 line intensity ratios, predicted to have a value of 2.0 in the optically thin case, are found to be up to ~30% larger during several orbital phases.
Conclusions. Our measurements, combined with radiative transfer models, allow us to constrain both the geometry of the O vi emitting regions in our stellar sources and the orientation of the observer. A spherical emitting plasma can be ruled out, as this would lead to no intensity enhancement. In addition, the theory tells us that the line-of-sight to the plasma must be close to perpendicular to its surface, as observations at small angles to the surface lead to either no intensity enhancement or the usual line intensity decrease over the optically thin value. For the future, we outline a laboratory experiment, that could be undertaken with current facilities, which would provide an unequivocal test of predictions of line intensity enhancement due to opacity, in particular the dependence on plasma geometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Memorial Stadium project will investigate the current conditions of facilities, study existing programs with regard to renovation and modification, and establish capacities for expansion. The project necessitates knowledge of sports facilities and the specific needs of the football program. This may involve research into the need of individuals ranging from the players themselves to the coaches, and ultimately the fans as well. The result will lead to a program which provides excellent solutions to the found needs. It is assumed that these needs will include updated training, locker room, and medical facilities for the athletes. Other programs include offices and meeting rooms for coaches, additional seating for fans—raising overall seating capacity of Memorial Stadium, as well as the possible addition of luxury skyboxes. Existing spaces will be scrutinized and renovation options will be explored. Programs may be changed or moved within the existing stadium spaces. Study will uncover the most feasible and reasonable solutions to programming spaces within the stadiums current facilities. This project will seek to connect the architecture of a stadium with the experience of the game. The design of athletic facilities and the addition of seating will embody the tradition of winning and the excitement of the future for Nebraska Football in Memorial Stadium. Mark Hoistad, mentor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent years have seen the introduction of formalised accreditation processes in both community and residential aged care, but these only partially address quality assessment within this sector. Residential aged care in Australia does not yet have a standardised system of resident assessment related to clinical, rather than administrative, outcomes. This paper describes the development of a quality assessment tool aimed at addressing this gap. Utilising previous research and the results of nominal groups with experts in the field, the 21-item Clinical Care Indicators (CCI) Tool for residential aged care was developed and trialled nationally. The CCI Tool was found to be simple to use and an effective means of collecting data on the state of resident health and care, with potential benefits for resident care planning and continuous quality improvement within facilities and organisations. The CCI Tool was further refined through a small intervention study to assess its utility as a quality improvement instrument and to investigate its relationship with resident quality of life. The current version covers 23 clinical indicators, takes about 30 minutes to complete and is viewed favourably by nursing staff who use it. Current work focuses on psychometric analysis and benchmarking, which should enable the CCI Tool to make a positive contribution to the measurement of quality in aged care in Australia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within contemporary inpatient mental health nursing practice, the psychodynamic model of care considered previously to be central to the nurse-patient relationship now seems a radical concept. It appears to exist only within primary care facilities and public health care practice settings. This naturalistic inquiry aimed to explicate mental health nurses' perspectives and expectations of providing psychodynamic therapeutic care in acute inpatient psychiatric facilities. Ten registered nurses working in acute inpatient mental health facilities were interviewed. Five themes emerged: a career for life, relating in a psychodynamic manner, swimming against the current, adopting a position of difference, and hopeful expectancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the policies and instruments adopted in Hong Kong to control the carbon emissions of construction facilities, including the whole building life cycle: production of material stage, construction stage, operation stage and demolition stage. This commences with a literature review comparing activities world-wide to those in Hong Kong to identify the main issues at stake, followed by a report on a series of local interviews to evaluate the present situation in Hong Kong, as well as future opportunities for local carbon mitigation. The interviewees included practitioners from engineering contracting firms, consulting firms, clients and energy provider, together with two university experts and a counsellor. A small case study is also provided of a building project in Hong Kong to illustrate some of the innovative design aspects being incorporated into buildings in Hong Kong as a result of the current emphasis on sustainability. The paper concludes with a summary of main findings and proposals for improvement in policy related to carbon mitigation and building sustainability in Hong Kong.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background On-site wastewater treatment system (OWTS) siting, design and management has traditionally been based on site specific conditions with little regard to the surrounding environment or the cumulative effect of other systems in the environment. The general approach has been to apply the same framework of standards and regulations to all sites equally, regardless of the sensitivity, or lack thereof, to the receiving environment. Consequently, this has led to the continuing poor performance and failure of on-site systems, resulting in environmental and public health consequences. As a result, there is increasing realisation that more scientifically robust evaluations in regard to site assessment and the underlying ground conditions are needed. Risk-based approaches to on-site system siting, design and management are considered the most appropriate means of improvement to the current standards and codes for on-site wastewater treatment systems. The Project Research in relation to this project was undertaken within the Gold Coast City Council region, the major focus being the semi-urban, rural residential and hinterland areas of the city that are not serviced by centralised treatment systems. The Gold Coast has over 15,000 on-site systems in use, with approximately 66% being common septic tank-subsurface dispersal systems. A recent study evaluating the performance of these systems within the Gold Coast area showed approximately 90% were not meeting the specified guidelines for effluent treatment and dispersal. The main focus of this research was to incorporate strong scientific knowledge into an integrated risk assessment process to allow suitable management practices to be set in place to mitigate the inherent risks. To achieve this, research was undertaken focusing on three main aspects involved with the performance and management of OWTS. Firstly, an investigation into the suitability of soil for providing appropriate effluent renovation was conducted. This involved detailed soil investigations, laboratory analysis and the use of multivariate statistical methods for analysing soil information. The outcomes of these investigations were developed into a framework for assessing soil suitability for effluent renovation. This formed the basis for the assessment of OWTS siting and design risks employed in the developed risk framework. Secondly, an assessment of the environmental and public health risks was performed specifically related the release of contaminants from OWTS. This involved detailed groundwater and surface water sampling and analysis to assess the current and potential risks of contamination throughout the Gold Coast region. Additionally, the assessment of public health risk incorporated the use of bacterial source tracking methods to identify the different sources of fecal contamination within monitored regions. Antibiotic resistance pattern analysis was utilised to determine the extent of human faecal contamination, with the outcomes utilised for providing a more indicative public health assessment. Finally, the outcomes of both the soil suitability assessment and ground and surface water monitoring was utilised for the development of the integrated risk framework. The research outcomes achieved through this project enabled the primary research aims and objects to be accomplished. This in turn would enable Gold Coast City Council to provide more appropriate assessment and management guidelines based on robust scientific knowledge which will ultimately ensure that the potential environmental and public health impacts resulting from on-site wastewater treatment is minimised. As part of the implementation of suitable management strategies, a critical point monitoring program (CPM) was formulated. This entailed the identification of the key critical parameters that contribute to the characterised risks at monitored locations within the study area. The CPM will allow more direct procedures to be implemented, targeting the specific hazards at sensitive areas throughout Gold Coast region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efficient management of domestic wastewater is a primary requirement for human well being. Failure to adequately address issues of wastewater collection, treatment and disposal can lead to adverse public health and environmental impacts. The increasing spread of urbanisation has led to the conversion of previously rural land into urban developments and the more intensive development of semi urban areas. However the provision of reticulated sewerage facilities has not kept pace with this expansion in urbanisation. This has resulted in a growing dependency on onsite sewage treatment. Though considered only as a temporary measure in the past, these systems are now considered as the most cost effective option and have become a permanent feature in some urban areas. This report is the first of a series of reports to be produced and is the outcome of a research project initiated by the Brisbane City Council. The primary objective of the research undertaken was to relate the treatment performance of onsite sewage treatment systems with soil conditions at site, with the emphasis being on septic tanks. This report consists of a ‘state of the art’ review of research undertaken in the arena of onsite sewage treatment. The evaluation of research brings together significant work undertaken locally and overseas. It focuses mainly on septic tanks in keeping with the primary objectives of the project. This report has acted as the springboard for the later field investigations and analysis undertaken as part of the project. Septic tanks still continue to be used widely due to their simplicity and low cost. Generally the treatment performance of septic tanks can be highly variable due to numerous factors, but a properly designed, operated and maintained septic tank can produce effluent of satisfactory quality. The reduction of hydraulic surges from washing machines and dishwashers, regular removal of accumulated septage and the elimination of harmful chemicals are some of the practices that can improve system performance considerably. The relative advantages of multi chamber over single chamber septic tanks is an issue that needs to be resolved in view of the conflicting research outcomes. In recent years, aerobic wastewater treatment systems (AWTS) have been gaining in popularity. This can be mainly attributed to the desire to avoid subsurface effluent disposal, which is the main cause of septic tank failure. The use of aerobic processes for treatment of wastewater and the disinfection of effluent prior to disposal is capable of producing effluent of a quality suitable for surface disposal. However the field performance of these has been disappointing. A significant number of these systems do not perform to stipulated standards and quality can be highly variable. This is primarily due to houseowner neglect or ignorance of correct operational and maintenance procedures. The other problems include greater susceptibility to shock loadings and sludge bulking. As identified in literature a number of design features can also contribute to this wide variation in quality. The other treatment processes in common use are the various types of filter systems. These include intermittent and recirculating sand filters. These systems too have their inherent advantages and disadvantages. Furthermore as in the case of aerobic systems, their performance is very much dependent on individual houseowner operation and maintenance practices. In recent years the use of biofilters has attracted research interest and particularly the use of peat. High removal rates of various wastewater pollutants have been reported in research literature. Despite these satisfactory results, leachate from peat has been reported in various studies. This is an issue that needs further investigations and as such biofilters can still be considered to be in the experimental stage. The use of other filter media such as absorbent plastic and bark has also been reported in literature. The safe and hygienic disposal of treated effluent is a matter of concern in the case of onsite sewage treatment. Subsurface disposal is the most common and the only option in the case of septic tank treatment. Soil is an excellent treatment medium if suitable conditions are present. The processes of sorption, filtration and oxidation can remove the various wastewater pollutants. The subsurface characteristics of the disposal area are among the most important parameters governing process performance. Therefore it is important that the soil and topographic conditions are taken into consideration in the design of the soil absorption system. Seepage trenches and beds are the common systems in use. Seepage pits or chambers can be used where subsurface conditions warrant, whilst above grade mounds have been recommended for a variety of difficult site conditions. All these systems have their inherent advantages and disadvantages and the preferable soil absorption system should be selected based on site characteristics. The use of gravel as in-fill for beds and trenches is open to question. It does not contribute to effluent treatment and has been shown to reduce the effective infiltrative surface area. This is due to physical obstruction and the migration of fines entrained in the gravel, into the soil matrix. The surface application of effluent is coming into increasing use with the advent of aerobic treatment systems. This has the advantage that treatment is undertaken on the upper soil horizons, which is chemically and biologically the most effective in effluent renovation. Numerous research studies have demonstrated the feasibility of this practice. However the overriding criteria is the quality of the effluent. It has to be of exceptionally good quality in order to ensure that there are no resulting public health impacts due to aerosol drift. This essentially is the main issue of concern, due to the unreliability of the effluent quality from aerobic systems. Secondly, it has also been found that most householders do not take adequate care in the operation of spray irrigation systems or in the maintenance of the irrigation area. Under these circumstances surface disposal of effluent should be approached with caution and would require appropriate householder education and stringent compliance requirements. However despite all this, the efficiency with which the process is undertaken will ultimately rest with the individual householder and this is where most concern rests. Greywater too should require similar considerations. Surface irrigation of greywater is currently being permitted in a number of local authority jurisdictions in Queensland. Considering the fact that greywater constitutes the largest fraction of the total wastewater generated in a household, it could be considered to be a potential resource. Unfortunately in most circumstances the only pretreatment that is required to be undertaken prior to reuse is the removal of oil and grease. This is an issue of concern as greywater can considered to be a weak to medium sewage as it contains primary pollutants such as BOD material and nutrients and may also include microbial contamination. Therefore its use for surface irrigation can pose a potential health risk. This is further compounded by the fact that most householders are unaware of the potential adverse impacts of indiscriminate greywater reuse. As in the case of blackwater effluent reuse, there have been suggestions that greywater should also be subjected to stringent guidelines. Under these circumstances the surface application of any wastewater requires careful consideration. The other option available for the disposal effluent is the use of evaporation systems. The use of evapotranspiration systems has been covered in this report. Research has shown that these systems are susceptible to a number of factors and in particular to climatic conditions. As such their applicability is location specific. Also the design of systems based solely on evapotranspiration is questionable. In order to ensure more reliability, the systems should be designed to include soil absorption. The successful use of these systems for intermittent usage has been noted in literature. Taking into consideration the issues discussed above, subsurface disposal of effluent is the safest under most conditions. This is provided the facility has been designed to accommodate site conditions. The main problem associated with subsurface disposal is the formation of a clogging mat on the infiltrative surfaces. Due to the formation of the clogging mat, the capacity of the soil to handle effluent is no longer governed by the soil’s hydraulic conductivity as measured by the percolation test, but rather by the infiltration rate through the clogged zone. The characteristics of the clogging mat have been shown to be influenced by various soil and effluent characteristics. Secondly, the mechanisms of clogging mat formation have been found to be influenced by various physical, chemical and biological processes. Biological clogging is the most common process taking place and occurs due to bacterial growth or its by-products reducing the soil pore diameters. Biological clogging is generally associated with anaerobic conditions. The formation of the clogging mat provides significant benefits. It acts as an efficient filter for the removal of microorganisms. Also as the clogging mat increases the hydraulic impedance to flow, unsaturated flow conditions will occur below the mat. This permits greater contact between effluent and soil particles thereby enhancing the purification process. This is particularly important in the case of highly permeable soils. However the adverse impacts of the clogging mat formation cannot be ignored as they can lead to significant reduction in the infiltration rate. This in fact is the most common cause of soil absorption systems failure. As the formation of the clogging mat is inevitable, it is important to ensure that it does not impede effluent infiltration beyond tolerable limits. Various strategies have been investigated to either control clogging mat formation or to remediate its severity. Intermittent dosing of effluent is one such strategy that has attracted considerable attention. Research conclusions with regard to short duration time intervals are contradictory. It has been claimed that the intermittent rest periods would result in the aerobic decomposition of the clogging mat leading to a subsequent increase in the infiltration rate. Contrary to this, it has also been claimed that short duration rest periods are insufficient to completely decompose the clogging mat, and the intermediate by-products that form as a result of aerobic processes would in fact lead to even more severe clogging. It has been further recommended that the rest periods should be much longer and should be in the range of about six months. This entails the provision of a second and alternating seepage bed. The other concepts that have been investigated are the design of the bed to meet the equilibrium infiltration rate that would eventuate after clogging mat formation; improved geometry such as the use of seepage trenches instead of beds; serial instead of parallel effluent distribution and low pressure dosing of effluent. The use of physical measures such as oxidation with hydrogen peroxide and replacement of the infiltration surface have been shown to be only of short-term benefit. Another issue of importance is the degree of pretreatment that should be provided to the effluent prior to subsurface application and the influence exerted by pollutant loadings on the clogging mat formation. Laboratory studies have shown that the total mass loadings of BOD and suspended solids are important factors in the formation of the clogging mat. It has also been found that the nature of the suspended solids is also an important factor. The finer particles from extended aeration systems when compared to those from septic tanks will penetrate deeper into the soil and hence will ultimately cause a more dense clogging mat. However the importance of improved pretreatment in clogging mat formation may need to be qualified in view of other research studies. It has also shown that effluent quality may be a factor in the case of highly permeable soils but this may not be the case with fine structured soils. The ultimate test of onsite sewage treatment system efficiency rests with the final disposal of effluent. The implication of system failure as evidenced from the surface ponding of effluent or the seepage of contaminants into the groundwater can be very serious as it can lead to environmental and public health impacts. Significant microbial contamination of surface and groundwater has been attributed to septic tank effluent. There are a number of documented instances of septic tank related waterborne disease outbreaks affecting large numbers of people. In a recent incident, the local authority was found liable for an outbreak of viral hepatitis A and not the individual septic tank owners as no action had been taken to remedy septic tank failure. This illustrates the responsibility placed on local authorities in terms of ensuring the proper operation of onsite sewage treatment systems. Even a properly functioning soil absorption system is only capable of removing phosphorus and microorganisms. The nitrogen remaining after plant uptake will not be retained in the soil column, but will instead gradually seep into the groundwater as nitrate. Conditions for nitrogen removal by denitrification are not generally present in a soil absorption bed. Dilution by groundwater is the only treatment available for reducing the nitrogen concentration to specified levels. Therefore based on subsurface conditions, this essentially entails a maximum allowable concentration of septic tanks in a given area. Unfortunately nitrogen is not the only wastewater pollutant of concern. Relatively long survival times and travel distances have been noted for microorganisms originating from soil absorption systems. This is likely to happen if saturated conditions persist under the soil absorption bed or due to surface runoff of effluent as a result of system failure. Soils have a finite capacity for the removal of phosphorus. Once this capacity is exceeded, phosphorus too will seep into the groundwater. The relatively high mobility of phosphorus in sandy soils have been noted in the literature. These issues have serious implications in the design and siting of soil absorption systems. It is not only important to ensure that the system design is based on subsurface conditions but also the density of these systems in given areas is a critical issue. This essentially involves the adoption of a land capability approach to determine the limitations of an individual site for onsite sewage disposal. The most limiting factor at a particular site would determine the overall capability classification for that site which would also dictate the type of effluent disposal method to be adopted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to examine the quality of service of a South East Asian country's military facilities management organisation. Design/methodology/approach – An interview survey and questionnaire survey were used to obtain a description and summary of stakeholders’ expectations and the extent to which they were being satisfied by the services provided. Findings – The method provides a useful means of identifying and prioritising varying expectations between stakeholder groups and of indicating any mismatch in expectations in the management of military facilities. Social implications – The development and use of a method to test and improve the effectiveness and efficiency of the management of military facilities helps in providing better value for money. Originality/value – In addition to re-affirming Parasuraman's overall dimensions of service expectation, the empirical summary of the stakeholders’ expectations obtained in this way is of practical value for the service provider in developing a strategy for expectation management. For the case studied, it is also apparent that although the current processes in service delivery are well understood by all involved stakeholders, there is a need for further improvement with regards to their expectation levels. It is also one of the very few reported studies on the management of military facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Australian subacute rehabilitation facilities face significant challenges from the ageing population with increased burden of chronic disease. High risk foot complications are a negative consequence of many chronic diseases. With the rapid expansion of subacute services, it seems imperative to investigate the prevalence of foot complications in this population. The primary aim of this study was to quantify the high risk foot complication prevalence in a subacute rehabilitation population. Methods Eligible participants were all adults admitted overnight, over two 4 week periods, into a large Australian subacute rehabilitation facility. Consenting participants underwent a short non-invasive foot examination by a podiatrist. The standard Queensland Health High Risk Foot Form collected data on age, sex, co-morbidities and foot complications. Descriptive statistics, logistic regression and odds ratios were used to determine the prevalence of foot complications and associations with explanatory variables. Results Overall, 85 of 97 eligible participants consented; mean age 80(9) and 71% were female. At least one foot complication was present in 56.5% participants; including 21.2% defined as high risk and 11.8% current foot ulcer. A previous diagnosis of neuropathy increased the risk of presenting with a high risk foot by 13-fold (OR 13.504, p = 0.001). Conclusion This study highlights the significance of foot complications in the subacute population. It appears that one in every two patients present with a foot complication and one in eight with a foot ulcer. It is suggested all patients admitted to subacute rehabilitation services should be screened for foot complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deoxyribonucleic acid (DNA) extraction has considerably evolved since it was initially performed back in 1869. It is the first step required for many of the available downstream applications used in the field of molecular biology. Whole blood samples are one of the main sources used to obtain DNA, and there are many different protocols available to perform nucleic acid extraction on such samples. These methods vary from very basic manual protocols to more sophisticated methods included in automated DNA extraction protocols. Based on the wide range of available options, it would be ideal to determine the ones that perform best in terms of cost-effectiveness and time efficiency. We have reviewed DNA extraction history and the most commonly used methods for DNA extraction from whole blood samples, highlighting their individual advantages and disadvantages. We also searched current scientific literature to find studies comparing different nucleic acid extraction methods, to determine the best available choice. Based on our research, we have determined that there is not enough scientific evidence to support one particular DNA extraction method from whole blood samples. Choosing a suitable method is still a process that requires consideration of many different factors, and more research is needed to validate choices made at facilities around the world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Overview The incidence of skin tears, pressure injuries and chronic wounds increases with age [1-4] and therefore is a serious issue for staff and residents in Residential Aged Care Facilities (RACFs). A pilot project funded in Round 2 of the Encouraging Best Practice in Residential Aged Care (EBPRAC) program by the then Australian Government Department of Health and Ageing found that a substantial proportion of residents in aged care facilities experienced pressure injuries, skin tears or chronic wounds. It also found the implementation of the evidence based Champions for Skin Integrity (CSI) model of wound care was successful in significantly decreasing the prevalence and severity of wounds in residents, improving staff skills and knowledge of evidence based wound management, increasing staff confidence with wound management, increasing implementation of evidence based wound management and prevention strategies, and increasing staff awareness of their roles in evidence based wound care at all levels [5]. Importantly, during the project, the project team developed a resource kit on evidence based wound management. Two critical recommendations resulting from the project were that: - The CSI model or a similar strategic approach should be implemented in RACFs to facilitate the uptake of evidence based wound management and prevention - The resource kit on evidence based wound management should be made available to all Residential Aged Care Facilities and interested parties A proposal to disseminate or rollout the CSI model of wound care to all RACFs across Australia was submitted to the department in 2012. The department approved funding from the Aged Care Services Improvement Healthy Ageing Grant (ACSIHAG) at the same time as the Round 3 of the Encouraging Better Practice in Aged Care (EBPAC) program. The dissemination involved two crucial elements: 1. The updating, refining and distribution of a Champions for Skin Integrity Resource Kit, more commonly known as a CSI Resource Kit and 2. The presentation of intensive one day Promoting Healthy Skin “Train the Trainer” workshops in all capital cities and major regional towns across Australia Due to demand, the department agreed to fund a second round of workshops focussing on regional centres and the completion date was extended to accommodate the workshops. Later, the department also decided to host a departmental website for a number of clinical domains, including wound management, so that staff from the residential aged care sector had easy access to a central repository of helpful clinical resource material that could be used for improving the health and wellbeing of their older adults, consumers and carers. CSI Resource Kit Upgrade and Distribution: At the start of the project, a full evidence review was carried out on the material produced during the EBPRAC-CSI Stage 1 project and the relevant evidence based changes were made to the documentation. At the same time participants in the EBPRAC-CSI Stage 1 project were interviewed for advice on how to improve the resource material. Following this the documentation, included in the kit, was sent to independent experts for peer review. When this process was finalised, a learning designer and QUT’s Visual Communications Services were engaged to completely refine and update the design of the resources, and combined resource kit with the goal of keeping the overall size of the kit suitable for bookshelf mounting and the cost at reasonable levels. Both goals were achieved in that the kit is about the same size as a 25 mm A4 binder and costs between $19.00 and $28.00 per kit depending on the size of the print run. The dissemination of the updated CSI resource kit was an outstanding success. Demand for the kits was so great that a second print run of 2,000 kits was arranged on top of the initial print run of 4,000 kits. All RACFs across Australia were issued with a kit, some 2,740 in total. Since the initial distribution another 1,100 requests for kits has been fulfilled as well as 1,619 kits being distributed to participants at the Promoting Healthy Skin workshops. As the project was winding up a final request email was sent to all workshop participants asking if they required additional kits or resources to distribute the remaining kits and resources. This has resulted in requests for 200 additional kits and resources. Feedback from the residential aged care sector and other clinical providers who have interest in wound care has been very positive regarding the utility of the kit, (see Appendix 4). Promoting Healthy Skin Workshops The workshops also exceeded the project team’s initial objective. Our goal of providing workshop training for staff from one in four facilities and 450 participants was exceeded, with overwhelming demand for workshop places resulting in the need to provide a second round of workshops across Australia. At the completion of the second round, 37 workshops had been given, with 1286 participants, representing 835 facilities. A number of strategies were used to promote the workshops ranging from invitations included in the kit, to postcard mail-outs, broadcast emailing to all facilities and aged care networks and to articles and paid advertising in aged care journals. The most effective method, by far, was directly phoning the facilities. This enabled the caller to contact the relevant staff member and enlist their support for the workshop. As this is a labour intensive exercise, it was only used where numbers needed bolstering, with one venue rising from 3 registrants before the calls to 53 registrants after. The workshops were aimed at staff who had the interest and the capability of implementing evidence-based wound management within their facility or organisation. This targeting was successful in that a large proportion (68%) of participants were Registered Nurses, Nurse Managers, Educators or Consultants. Twenty percent were Endorsed Enrolled Nurses with the remaining 12% being made up of Personal Care Workers or Allied Health Professionals. To facilitate long term sustainability, the workshop employed train-the-trainer strategies. Feedback from the EBPRAC-CSI Stage 1 interviews was used in the development of workshop content. In addition, feedback from the workshop conducted at the end of the EBPRAC-CSI Stage 1 project suggested that change management and leadership training should be included in the workshops. The program was trialled in the first workshop conducted in Brisbane and then rolled out across Australia. Participants were asked to complete pre and post workshop surveys at the beginning and end of the workshop to determine how knowledge and confidence improved over the day. Results from the pre and post surveys showed significant improvements in the level of confidence in attendees’ ability to implement evidence based wound management. The results also indicated a significant increase in the level of confidence in ability to implement change within their facility or organisation. This is an important indication that the inclusion of change management/leadership training with clinical instruction can increase staff capacity and confidence in translating evidence into practice. To encourage the transfer of the evidence based content of the workshop into practice, participants were asked to prepare an Action Plan to be followed by a simple one page progress report three months after the workshop. These reports ranged from simple (e.g. skin moisturising to prevent skin tears), to complex implementation plans for introducing the CSI model across the whole organisation. Outcomes described in the project reports included decreased prevalence of skin tears, pressure injuries and chronic wounds, along with increased staff and resident knowledge and resident comfort. As stated above, some organisations prepared large, complex plans to roll out the CSI model across their organisation. These plans included a review of the organisation’s wound care system, policies and procedures, the creation of new processes, the education of staff and clients, uploading education and resource material onto internal electronic platforms and setting up formal review and evaluation processes. The CSI Resources have been enthusiastically sought and incorporated into multiple health care settings, including aged care, acute care, Medicare Local intranets (e.g. Map of Medicine e-pathways), primary health care, community and home care organisations, education providers and New Zealand aged and community health providers. Recommendations: Recommendations for RACFs, aged care and health service providers and government  Skin integrity and the evidence-practice gap in this area should be recognised as a major health issue for health service providers for older adults, with wounds experienced by up to 50% of residents in aged care settings (Edwards et al. 2010). Implementation of evidence based wound care through the Champions for Skin Integrity model in this and the pilot project has demonstrated the prevalence of wounds, wound healing times and wound infections can be halved.  A national program and Centre for Evidence Based Wound Management should be established to: - expand the reach of the model to other aged care facilities and health service providers for older adults - sustain the uptake of models such as the Champions for Skin Integrity (CSI) model - ensure current resources, expertise and training are available for consumers and health care professionals to promote skin integrity for all older adults  Evidence based resources for the CSI program and similar projects should be reviewed and updated every 3 – 4 years as per NH&MRC recommendations  Leadership and change management training is fundamental to increasing staff capacity, at all levels, to promote within-organisation dissemination of skills and knowledge gained from projects providing evidence based training Recommendations for future national dissemination projects  A formal program of opportunities for small groups of like projects to share information and resources, coordinate activities and synergise education programs interactively would benefit future national dissemination projects - Future workshop programs could explore an incentive program to optimise attendance and reduce ‘no shows’ - Future projects should build in the capacity and funding for increased follow-up with workshop attendees, to explore the reasons behind those who are unable to translate workshop learnings into the workplace and identify factors to address these barriers.