993 resultados para cryogenic vacuum extraction


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: When clinically indicated, common obstetric interventions can greatly improve maternal and neonatal outcomes. However, variation in intervention rates suggests that obstetric practice may not be solely driven by case criteria. Methods: Differences in obstetric intervention rates by private and public status in Ireland were examined using nationally representative hospital discharge data. A retrospective cohort study was performed on childbirth hospitalisations occurring between 2005 and 2010. Multivariate logistic regression analysis with correction for the relative risk was conducted to determine the risk of obstetric intervention (caesarean delivery, operative vaginal delivery, induction of labour or episiotomy) by private or public status while adjusting for obstetric risk factors. Results: 403,642 childbirth hospitalisations were reviewed; approximately one-third of maternities (30.2%) were booked privately. After controlling for relevant obstetric risk factors, women with private coverage were more likely to have an elective caesarean delivery (RR: 1.48; 95% CI: 1.45-1.51), an emergency caesarean delivery (RR: 1.13; 95% CI: 1.12-1.16) and an operative vaginal delivery (RR: 1.25; 95% CI: 1.22-1.27). Compared to women with public coverage who had a vaginal delivery, women with private coverage were 40% more likely to have an episiotomy (RR: 1.40; 95% CI: 1.38-1.43). Conclusions: Irrespective of obstetric risk factors, women who opted for private maternity care were significantly more likely to have an obstetric intervention. To better understand both clinical and non-clinical dynamics, future studies of examining health care coverage status and obstetric intervention would ideally apply mixed-method techniques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Little is known about the aetiology of childhood brain tumours. We investigated anthropometric factors (birth weight, length, maternal age), birth characteristics (e.g. vacuum extraction, preterm delivery, birth order) and exposures during pregnancy (e.g. maternal: smoking, working, dietary supplement intake) in relation to risk of brain tumour diagnosis among 7-19 year olds. The multinational case-control study in Denmark, Sweden, Norway and Switzerland (CEFALO) included interviews with 352 (participation rate=83.2%) eligible cases and 646 (71.1%) population-based controls. Interview data were complemented with data from birth registries and validated by assessing agreement (Cohen's Kappa). We used conditional logistic regression models matched on age, sex and geographical region (adjusted for maternal age and parental education) to explore associations between birth factors and childhood brain tumour risk. Agreement between interview and birth registry data ranged from moderate (Kappa=0.54; worked during pregnancy) to almost perfect (Kappa=0.98; birth weight). Neither anthropogenic factors nor birth characteristics were associated with childhood brain tumour risk. Maternal vitamin intake during pregnancy was indicative of a protective effect (OR 0.75, 95%-CI: 0.56-1.01). No association was seen for maternal smoking during pregnancy or working during pregnancy. We found little evidence that the considered birth factors were related to brain tumour risk among children and adolescents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We compare alkalinity and total dissolved inorganic carbon (DIC) measurements made during the Transient Tracers in the Ocean, North Atlantic Study (TTO-NAS) in 1981 with modern measurements from a TTO reoccupation cruise in 2004 (M60/5). We find that the TTO-NAS alkalinity values are 3.6 ± 2.3 µmol/kg higher than modern alkalinity data tied to Certified Reference Materials. The TTO-NAS DIC values re-calculated from original alkalinity and discrete-pCO2 data using currently accepted constants are 3.8 µmol/kg higher than those reported in the revised TTO data set. This difference is reduced to 0.7 µmol/kg when our suggested correction to the TTO-NAS alkalinity is applied. These re-calculated DIC values are 2.4 µmol/kg too low relative to contemporaneous measurements made by the vacuum extraction/manometric Certified method. Application of this correction brings the TTO data into almost perfect agreement with modern measurements for slowly-ventilated deep water of the eastern Atlantic.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using the mechanically controlled break junction technique at low temperatures and under cryogenic vacuum conditions we have studied atomic contacts of several magnetic (Fe, Co, and Ni) and nonmagnetic (Pt) metals, which recently were claimed to show fractional conductance quantization. In the case of pure metals we see no quantization of the conductance nor half quantization, even when high magnetic fields are applied. On the other hand, features in the conductance similar to (fractional) quantization are observed when the contact is exposed to gas molecules. Furthermore, the absence of fractional quantization when the contact is bridged by H2 indicates the current is never fully polarized for the metals studied here. Our results are in agreement with recent model calculations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Some psychological variables of women seem to be in close relationship with the clinical course of pregnancy and delivery outcome. However, about risk factors for preterm birth, it is necessary to deepen the knowledge of the psychological risk area to enable more effective prevention. Aim: To relate the result of delivery, with regard to gestational age, mode of delivery and infant characteristics with psychological variables assessed during pregnancy, prenatal maternal attachment, psychopathological symptomatology and coping. Methodology: A prospective, descriptive correlational study; participants were 395 women at the second trimester of pregnancy and at postpartum, who attended antenatal clinics at the center of Portugal. The following instruments were used: Clinical Questionnaire about the Result of Delivery; Sociodemographic and Clinical Questionnaire in Pregnancy; Maternal Antenatal Attachment Scale; Brief Symptoms Inventory (BSI); Problems’ Resolution Inventory (PRI). Results: Gestational age and birth weight of the baby, on one side, and variables of prenatal attachment, BSI and PRI, on the other side, did not correlate significantly. The quality of prenatal maternal attachment was higher in women who came to have a delivery by forceps or vacuum extraction, compared with those that had caesarean birth (p = .05). The majority of women had a healthy pregnancy (75.7%). Coping strategies like Interpersonal Sensitivity and Help-seeking seem to influence the occurrence of obstetrical pathology. Women with higher scores on Total Prenatal Attachment and Intensity of Preocupation are more likely to have newborns with health problems. There is an association between clinical variables, the newborn´s health at birth and obstetric pathology of the II and III trimesters. Conclusion: Prenatal psychological factors such as prenatal attachment do not seem to influence the obstetric condition or the result of delivery but appear to play an important role about how pregnant women experience pregnancy and labor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis discusses the use of sub- and supercritical fluids as the medium in extraction and chromatography. Super- and subcritical extraction was used to separate essential oils from herbal plant Angelica archangelica. The effect of extraction parameters was studied and sensory analyses of the extracts were done by an expert panel. The results of the sensory analyses were compared to the analytically determined contents of the extracts. Sub- and supercritical fluid chromatography (SFC) was used to separate and purify high-value pharmaceuticals. Chiral SFC was used to separate the enantiomers of racemic mixtures of pharmaceutical compounds. Very low (cryogenic) temperatures were applied to substantially enhance the separation efficiency of chiral SFC. The thermodynamic aspects affecting the resolving ability of chiral stationary phases are briefly reviewed. The process production rate which is a key factor in industrial chromatography was optimized by empirical multivariate methods. General linear model was used to optimize the separation of omega-3 fatty acid ethyl esters from esterized fish oil by using reversed-phase SFC. Chiral separation of racemic mixtures of guaifenesin and ferulic acid dimer ethyl ester was optimized by using response surface method with three variables per time. It was found that by optimizing four variables (temperature, load, flowate and modifier content) the production rate of the chiral resolution of racemic guaifenesin by cryogenic SFC could be increased severalfold compared to published results of similar application. A novel pressure-compensated design of industrial high pressure chromatographic column was introduced, using the technology developed in building the deep-sea submersibles (Mir 1 and 2). A demonstration SFC plant was built and the immunosuppressant drug cyclosporine A was purified to meet the requirements of US Pharmacopoeia. A smaller semi-pilot size column with similar design was used for cryogenic chiral separation of aromatase inhibitor Finrozole for use in its development phase 2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of non-evaporable Zr-V-Fe getters to enhance and maintain the vacuum of cryogenic systems have been studied. It has been shown that the pressur erise rate of the insulation space of these systems are significantly reduced by the getter activation. The gettering action is substantial even at abient temperature for many gases including hydrogen which can not be cryosorbed at LN2 temperatures. The getter can be activated several times and they can act as in-situ pumps for cryogenic systems, especially for field units.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single and two-stage Pulse Tube Cryocoolers (PTC) have been designed, fabricated and experimentally studied. The single stage PTC reaches a no-load temperature of similar to 29 K at its cold end, the two-stage PTC reaches similar to 2.9 K in its second stage cold end and similar to 60 K in its first stage cold end. The two-stage Pulse Tube Cryocooler provides a cooling power of similar to 250 mW at 4.2 K. The single stage system uses stainless steel meshes along with Pb granules as its regenerator materials, while the two-stage PTC uses combinations of Pb along with Er3Ni/HoCu2 as the second stage regenerator materials. Normally, the above systems are insulated by thermal radiation shields and mounted inside a vacuum chamber which is maintained at high vacuum. To evaluate the performance of these systems in the possible conditions of loss of vacuum with and without radiation shields, experimental studies have been performed. The heat-in-leak under such severe conditions has been estimated from the heat load characteristics of the respective stages. The experimental results are analyzed to obtain surface emissivities and effective thermal conductivities as a function of interspace pressure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The HIRFL (Heavy Ion Research Facility at Lanzhou) is a cyclotron complex. Its injector is a cector focusing cyclotron with K=69. Since the HIRFL started the operation in 1989, two bigger items of improvements have been finished, the species and intensity of the accelerated particles are increased obviously. But due to the lower extraction efficiency of the SFC, on one hand, a lot of beam lost, and on other hand, outgas from the surface of the electrostatic deflector is serious because of beam hitting. Even sometimes the vacuum press is destroyed. In the paper a new physical design is made to get an extraction system of the SFC with a higher efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of tetraalkylammonium methylcarbonate and hydrogencarbonate based ionic liquids are shown to be capable of reacting with the naphthenic acids contained in Doba crude oil via a neutralisation reaction. Spectral studies show that the ionic liquids neutralisation mechanism involves the formation of an ionic liquid-naphthenate complex, liberating methanol and carbon dioxide. Extraction of the neutralised complex into a separate methanol phase and subsequent regeneration using aqueous carbonic acid results in ∼70% of the ionic liquid being recovered for recycle. Isolation of the naphthenic acids shows that these make up to 0.85 wt% of the crude oil. Speciation of the naphthenic acids shows a mixture of monocyclic, through to tetracyclic structures with carbon numbers in the range C12-C40.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel extraction device for water and noble gases from speleothem samples for noble gas paleotemperature determination. The “combined vacuum crushing and sieving (CVCS) system” was designed to reduce the atmospheric noble gas contents from air inclusions in speleothem samples by up to 2 orders of magnitude without adsorbing atmospheric noble gases onto the freshly produced grain surfaces, a process that had often hampered noble gas temperature (NGT) determination in the past. We also present the results from first performance tests of the CVCS system processing stalagmite samples grown at a known temperature. This temperature is reliably reproduced by the NGTs derived from Ar, Kr, and Xe extracted from the samples. The CVCS system is, therefore, suitable for routine determinations of accurate NGTs. In combination with stalagmite dating, these NGTs will allow reconstructing past regional temperature evolutions, and also support the interpretation of the often complex stable isotope records preserved in the stalagmites' calcite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the development and optimization of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) based extraction technique coupled with a clean-up dispersive-solid phase extraction (dSPE) as a new, reliable and powerful strategy to enhance the extraction efficiency of free low molecular-weight polyphenols in selected species of dietary vegetables. The process involves two simple steps. First, the homogenized samples are extracted and partitioned using an organic solvent and salt solution. Then, the supernatant is further extracted and cleaned using a dSPE technique. Final clear extracts of vegetables were concentrated under vacuum to near dryness and taken up into initial mobile phase (0.1% formic acid and 20% methanol). The separation and quantification of free low molecular weight polyphenols from the vegetable extracts was achieved by ultrahigh pressure liquid chromatography (UHPLC) equipped with a phodiode array (PDA) detection system and a Trifunctional High Strength Silica capillary analytical column (HSS T3), specially designed for polar compounds. The performance of the method was assessed by studying the selectivity, linear dynamic range, the limit of detection (LOD) and limit of quantification (LOQ), precision, trueness, and matrix effects. The validation parameters of the method showed satisfactory figures of merit. Good linearity (View the MathML sourceRvalues2>0.954; (+)-catechin in carrot samples) was achieved at the studied concentration range. Reproducibility was better than 3%. Consistent recoveries of polyphenols ranging from 78.4 to 99.9% were observed when all target vegetable samples were spiked at two concentration levels, with relative standard deviations (RSDs, n = 5) lower than 2.9%. The LODs and the LOQs ranged from 0.005 μg mL−1 (trans-resveratrol, carrot) to 0.62 μg mL−1 (syringic acid, garlic) and from 0.016 μg mL−1 (trans-resveratrol, carrot) to 0.87 μg mL−1 ((+)-catechin, carrot) depending on the compound. The method was applied for studying the occurrence of free low molecular weight polyphenols in eight selected dietary vegetables (broccoli, tomato, carrot, garlic, onion, red pepper, green pepper and beetroot), providing a valuable and promising tool for food quality evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of ß-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A = 90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-fligh ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ< 1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported.