1000 resultados para cromatografia líquida de alta eficiência


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Emerging organic pollutants (EOP) include many environmental contaminants based on commercial products such as pharmaceuticals, personal care products, detergents, gasoline, polymers, etc. EOP may be candidates for future regulation as they offer potential risk to environmental and human health due to their continual entrance into the environment and to the fact that even the most modern wastewater treatment plants are not able to totally transform / remove these compounds. High performance liquid chromatography is recommended to separate emerging organic pollutants with characteristics of high polarity and low volatility, especially pharmaceuticals, from environmental matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Tecnologia e Segurança Alimentar

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar e validar um método para deteminação de resíduos de sulfatiazol (STZ), sulfametazina (SMZ) e sulfadimetoxina (SDM) em leite UHT integral. A extração foi realizada com diclorometano e coluna de extração em fase sólida de sílica. Os resíduos, após derivação com fluorescamina, foram quantificados por cromatografia líquida de alta eficiência com detector de fluorescência. O limite de detecção das três sulfas em amostra de leite integral foi 0,3 µg L-1 e o limite de quantificação foi 1 µg L-1 para STZ e SMZ e 2,5 µg L-1 para SDM, com coeficientes de variação entre 4,4 e 6,6%. Os valores de recuperação para STZ, SMZ e SDM foram 63,2, 91,2 e 63,2%, respectivamente. Considerando o limite máximo de resíduo estabelecido pela legislação brasileira de 100 µg kg-1 para a soma das concentrações totais de STZ, SMZ e SDM, o método descrito permite a determinação simultânea dos três analitos em amostras de leite UTH integral.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar uma alternativa para a quantificação simultânea de sulfatiazol, sulfametazina e sulfadimetoxina no leite, na forma de azoderivados, por meio de cromatografia líquida de alta eficiência (CLAE). O isolamento e concentração das sulfas foram conduzidos por extração em fase sólida (C18), com metanol como eluente. Após a extração, os analitos foram transformados em sais de diazônio e submetidos ao acoplamento com resorcinol. Os derivados foram separados e quantificados por CLAE (coluna C8, λ = 430 nm, MeOH/KH2PO4 aq.). Foram obtidas recuperações entre 65 e 78%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Particles of porous silica or other solvent resistent inorganic oxides can be functionalized by aliphatic (e.g., C-8 or C-18) or other groups to give stationary phases for use in reversed phase HPLC. The functionalization can be done by bonding of individual groups to the surface of the support particles, by producing an organic polymeric film from pre-polymers, or by adsorbing/immobilizing pre-formed polymers on the surfaces. These three types of functionalization are reviewed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of 60Co ionizing radiations in doses of 0, 75, 100, 150, 200 and 250Gy on garlic, upon the alpha-tocopherol concentration were studied. The alpha-tocopherol contents were established by high performance liquid chromatography (HPLC), after direct hexane extraction from the garlic samples. The alpha-tocopherol was determined through normal-phase column, and mobile phase was composed by hexane: iso-propyl alcohol (99:01 v/v), with 2mL/min flow rate and fluorescence detector. It is statistically shown that an irradiation dose of up to 150 Gy does not affect the garlic alpha-tocopherol content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work reviews recent advances in the preparation of new reversed phase packing materials such as sterically protected, bidentate, hybrid organic-inorganic and monolithic phases and phases containing embedded polar groups. The bonding chemistry involved in the preparation of these phases as well as their advantages over conventional C8 and C18 reversed phases are discussed. Understanding the reasons behind the development of these newer column packings helps analysts select the best stationary phase for a given application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high performance liquid chromatography method was developed to quantify lamivudine, stavudine and nevirapine combined in tablets. The separation was carried out in less than 10 min using a phosphate buffer of pH 3.0 and acetonitrile (75:25, v/v) as mobile phase, a LiChrospher ODS column and UV detection at 266 nm. The method was linear over the range of 15-135 µg/mL (lamivudine), 4-36 µg/mL (stavudine) and 20-180 µg/mL (nevirapine). The accuracy ranged from 98.56 to 102.04% and intra-day and inter-day precision was less than 1% for the three drugs. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A reverse phase liquid chromatography method was developed for simultaneous determination of trigonelline, caffeine, nicotinic and chlorogenic (5-CQA) acids in roasted coffee. A gradient of acetic acid/acetonitrile was used as mobile phase and detection was carried out in the UV. The samples were extracted with acetonitrile/water (5:95 v/v) at 80 ºC/10 min. Good recovery (89 to 104%), repeatability and linearity were obtained. Detection limits of 0.01, 0.15, 0.04 and 0.04 mg mL-1 were observed for nicotinic acid, trigonelline, 5-CQA and caffeine. The method, applied to arabica and robusta coffees with different degrees of roasting, was efficient and fast (~35 min) and also allowed identification of cinnamic acids.