927 resultados para counting rates
Resumo:
Counting-rate meters normally used for finding pulse frequencies are sluggish in their response to any rapid change in the pulse repetition frequency (P.R.F.). An instrument is described which measures each pulse interval and provides immediately afterwards an output voltage proportional to the reciprocal of interval duration. A response to a change in the P.R.F. as rapidly as is physically possible is obtained. The instrument has wide application in low level radiation detection and in several other fields especially for rapidly varying counting-rates.
Resumo:
In this work we use magnetic resonant x-ray diffraction to study the magnetic properties of a 1.5 mu m EuTe film and an EuTe/PbTe superlattice (SL). The samples were grown by molecular beam epitaxy on (111) oriented BaF(2) substrates. The measurements were made at the Eu L(2) absorption edge, taking profit of the resonant enhancement of more than two orders in the magnetically diffracted intensity. At resonance, high counting rates above 11000 cps were obtained for the 1.5 gm EuTe film, allowing to check for the type II antiferromagnetic order of EuTe. An equal population of the three possible in-plane magnetic domains was found. The EuTe/PbTe SL magnetic peak showed a satellite structure, indicating the presence of magnetic correlations among the 5 ML (monolayers) EuTe layers across the 15 ML PbTe non-magnetic spacers. The temperature dependence of the integrated intensities of the film and the SL yielded different Neel temperatures T(N). The lower T(N) for the SL is explained considering the higher influence of the surface atoms, with partial bonds lost.
Resumo:
Among all possible realizations of quark and antiquark assembly, the nucleon (the proton and the neutron) is the most stable of all hadrons and consequently has been the subject of intensive studies. Mass, shape, radius and more complex representations of its internal structure are measured since several decades using different probes. The proton (spin 1/2) is described by the electric GE and magnetic GM form factors which characterise its internal structure. The simplest way to measure the proton form factors consists in measuring the angular distribution of the electron-proton elastic scattering accessing the so-called Space-Like region where q2 < 0. Using the crossed channel antiproton proton <--> e+e-, one accesses another kinematical region, the so-called Time-Like region where q2 > 0. However, due to the antiproton proton <--> e+e- threshold q2th, only the kinematical domain q2 > q2th > 0 is available. To access the unphysical region, one may use the antiproton proton --> pi0 e+ e- reaction where the pi0 takes away a part of the system energy allowing q2 to be varied between q2th and almost 0. This thesis aims to show the feasibility of such measurements with the PANDA detector which will be installed on the new high intensity antiproton ring at the FAIR facility at Darmstadt. To describe the antiproton proton --> pi0 e+ e- reaction, a Lagrangian based approach is developed. The 5-fold differential cross section is determined and related to linear combinations of hadronic tensors. Under the assumption of one nucleon exchange, the hadronic tensors are expressed in terms of the 2 complex proton electromagnetic form factors. An extraction method which provides an access to the proton electromagnetic form factor ratio R = |GE|/|GM| and for the first time in an unpolarized experiment to the cosine of the phase difference is developed. Such measurements have never been performed in the unphysical region up to now. Extended simulations were performed to show how the ratio R and the cosine can be extracted from the positron angular distribution. Furthermore, a model is developed for the antiproton proton --> pi0 pi+ pi- background reaction considered as the most dangerous one. The background to signal cross section ratio was estimated under different cut combinations of the particle identification information from the different detectors and of the kinematic fits. The background contribution can be reduced to the percent level or even less. The corresponding signal efficiency ranges from a few % to 30%. The precision on the determination of the ratio R and of the cosine is determined using the expected counting rates via Monte Carlo method. A part of this thesis is also dedicated to more technical work with the study of the prototype of the electromagnetic calorimeter and the determination of its resolution.
Resumo:
Future experiments in nuclear and particle physics are moving towards the high luminosity regime in order to access rare processes. In this framework, particle detectors require high rate capability together with excellent timing resolution for precise event reconstruction. In order to achieve this, the development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging and expensive. Thus, a current trend in R&D is towards flexible FEE that can be easily adapted to a great variety of detectors, without impairing the required high performance. This thesis reports on a novel FEE for two different detector types: imaging Cherenkov counters and plastic scintillator arrays. The former requires high sensitivity and precision for detection of single photon signals, while the latter is characterized by slower and larger signals typical of scintillation processes. The FEE design was developed using high-bandwidth preamplifiers and fast discriminators which provide Time-over-Threshold (ToT). The use of discriminators allowed for low power consumption, minimal dead-times and self-triggering capabilities, all fundamental aspects for high rate applications. The output signals of the FEE are readout by a high precision TDC system based on FPGA. The performed full characterization of the analogue signals under realistic conditions proved that the ToT information can be used in a novel way for charge measurements or walk corrections, thus improving the obtainable timing resolution. Detailed laboratory investigations proved the feasibility of the ToT method. The full readout chain was investigated in test experiments at the Mainz Microtron: high counting rates per channel of several MHz were achieved, and a timing resolution of better than 100 ps after walk correction based on ToT was obtained. Ongoing applications to fast Time-of-Flight counters and future developments of FEE have been also recently investigated.
Resumo:
Tese (Doutoramento)
Resumo:
Mode of access: Internet.
Resumo:
The current crime decrease is defying traditional criminological theories such as those espoused by Bonger (1916) who researched the relationship between crime and economic conditions and stated that when unemployment rises so does crime. In both the USA and the UK crime has dropped dramatically while unemployment has risen. Both the USA and the UK have been in a deep recession since 2008 but the crime rate has decreased dramatically in both countries. Over the past 20 years it has halved in England and Wales. So how do we explain this phenomenon? Crime is down across the West but more so in Britain (see Figure 1). In England and Wales crime has decreased by 8% in a single year (2013). Vandalism is down by 14% and burglaries and vehicle crime by 11%. The murder rate in the UK is at its lowest since 1978; in 2013, 540 people were killed. Some less serious offences are vanishing too; antisocial behaviour has fallen from just under 4million incidents in 2007-08 to 2.4million. (The Economist 20/4/13). According to the most recent annual results from the Crime Survey for England and Wales (CSEW), crime is at its lowest level since the survey began in 1981; the most recent annual figures from the survey, Latest figures from the CSEW show there were an estimated 7.3 million incidents of crime against households and resident adults (aged 16 and over) in England and Wales for the year ending March 2014. This represents a 14% decrease compared with the previous year’s survey, and is the lowest estimate since the survey began in 1981.
Resumo:
In public places, crowd size may be an indicator of congestion, delay, instability, or of abnormal events, such as a fight, riot or emergency. Crowd related information can also provide important business intelligence such as the distribution of people throughout spaces, throughput rates, and local densities. A major drawback of many crowd counting approaches is their reliance on large numbers of holistic features, training data requirements of hundreds or thousands of frames per camera, and that each camera must be trained separately. This makes deployment in large multi-camera environments such as shopping centres very costly and difficult. In this chapter, we present a novel scene-invariant crowd counting algorithm that uses local features to monitor crowd size. The use of local features allows the proposed algorithm to calculate local occupancy statistics, scale to conditions which are unseen in the training data, and be trained on significantly less data. Scene invariance is achieved through the use of camera calibration, allowing the system to be trained on one or more viewpoints and then deployed on any number of new cameras for testing without further training. A pre-trained system could then be used as a ‘turn-key’ solution for crowd counting across a wide range of environments, eliminating many of the costly barriers to deployment which currently exist.
Resumo:
The discharge pulse rates at different magnitude levels are often used as criteria for monitoring the partial-discharge aging of insulation systems. Use of suggested corrections for errors in cumulative probability counting leads to better use of available counters.
Resumo:
The Santana Cave is located at the Upper Ribeira Touristic State Park (PETAR-Parque Estadual Turistico do Alto Ribeira) in southern São Paulo State, Brazil. This paper describes Pb-210 activity concentration data in soda straw stalactites samples collected at Salao das Flores in Santana Cave that is a fossil tributary of the cave river. Non-expensive alpha counting following some analytical steps for extracting and depositing Pb-210 were used for providing the Pb-210 data. In the analyzed samples, Pb-210 values of increasingly older samples fitted an exponential curve, thus suggesting that the production of Pb-210 has been constant with time. Also, the near-ideal fit indicated that the growth was uniform and there was no break in the continuous growth. The soda straw growth rates were determined from the best fit to the exponential curve through the Pb-210 activity concentration. The results of the measurements allowed estimate a longitudinal rate corresponding to 1.3 mm/yr and a lateral rate of 0.01 mm/yr, which permitted calculate times of 70 years and 317-498 years for their formation, respectively. The lateral growth rate is compatible with values from studies of chemical weathering rates held under laboratory and natural conditions. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Many epidemiological studies and clinical trials have been performed concerning actinic keratoses. The most eligible endpoint in the majority of articles is counting of actinic keratoses before and after treatments, nevertheless some authors support that this is not a reliable form of evaluation. The aim of this study was to evaluate the actinic keratoses counting by various raters and suggest approaches to increase the reliability. Cross-sectional study: forty-three patients were evaluated by four raters (inter- and intra-rater assessment) on the face and forearms. The mean actinic keratoses counts on the face and forearms were 7.7 and 9.1. The overall agreement among the raters for the facial and forearm actinic keratoses was 0.74 and 0.77. The intra-rater assessment showed high rates of agreement for the face (ICC = 0.93) and forearms (ICC = 0.83). Higher agreement occurred when counting up to five lesions. Four raters led to increased measurement variability and loss of reliability. Higher rates of agreement may be achieved with small number of lesions, limitation and/or segmentation of body areas to reduce their number, in AK prevention designs, are strategies that may lead to a greater reliability of these measurements. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Objective. To evaluate bacterial growth inhibition, mechanical properties, and compound release rate and stability of copolymers incorporated with anthocyanin (ACY; Vaccinium macrocarpon). Methods. Resin samples were prepared (Bis-GMA/TEGDMA at 70/30 mol%) and incorporated with 2 w/w% of either ACY or chlorhexidine (CHX), except for the control group. Samples were individually immersed in a bacterial culture (Streptococcus mutans) for 24 h. Cell viability (n = 3) was assessed by counting the number of colony forming units on replica agar plates. Flexural strength (FS) and elastic modulus (E) were tested on a universal testing machine (n = 8). Compound release and chemical stability were evaluated by UV spectrophotometry and (1)H NMR (n = 3). Data were analyzed by one-way ANOVA and Tukey's test ( α = 0.05). Results. Both compounds inhibited S. mutans growth, with CHX being most effective (P < 0.05). Control resin had the lowest FS and E values, followed by ACY and CHX, with statistical difference between control and CHX groups for both mechanical properties (P < 0.05). The 24 h compound release rates were ACY: 1.33 μg/mL and CHX: 1.92 μg/mL. (1)H NMR spectra suggests that both compounds remained stable after being released in water. Conclusion. The present findings indicate that anthocyanins might be used as a natural antibacterial agent in resin based materials.
Resumo:
Studies about natural and artificial radionuclides in areas such as the Antarctic are key to understand natural and dynamic processes in marine environments. These studies are important to determine levels of radioactive elements and local sedimentation rates. Five marine sediment cores were collected in different points of Admiralty Bay, in the Antarctic Peninsula. The purpose of this study was to determine 137Cs, 226Ra and 210Pb and sedimentation rates at each site. 137Cs, 210Pb and 226Ra were assayed by gamma-counting through direct measurement of the peak at 661 keV, 47 keV and 609 keV, respectively. Sedimentation rates were obtained by 137Cs and 210Pb (CIC and CRS). The activities for 137Cs ranged from 0.84 to 7.09 Bq kg-1; to 226Ra from 6.77 to 31.07 Bq kg-1 and for 210Pb ranged from 1.10 to 36.90 Bq kg-1. The sedimentation rates obtained by the three models ranged from 0.11±0.01 cm y-1 to 0.46±0.05 cm y-1. The levels of 137Cs registered in this study, as well as in other studies in the Antarctic region indicate that global fallout is the main cause of artificial radionuclides present in this environment, since the Antarctic has not suffered a direct action of human activities that released radioactive elements. The possible grain size variations that occur in the studied points of Admiralty Bay may explain the differences found in the vertical distribution of radionuclides, because of the different values of sedimentation rates and respective dating determined in their profiles
Resumo:
Performing experiments with transactinide elements demands highly sensitive detection methods due to the extremely low production rates (one-atom-at-a-time conditions). Preseparation with a physical recoil separator is a powerful method to significantly reduce the background in experiments with sufficiently long-lived isotopes (t1/2≥0.5 s). In the last years, the new gas-filled TransActinide Separator and Chemistry Apparatus (TASCA) was installed and successfully commissioned at GSI. Here, we report on the design and performance of a Recoil Transfer Chamber (RTC) for TASCA—an interface to connect various chemistry and counting setups with the separator. Nuclear reaction products recoiling out of the target are separated according to their magnetic rigidity within TASCA, and the wanted products are guided to the focal plane of TASCA. In the focal plane, they pass a thin Mylar window that separates the ∼1 mbar atmosphere in TASCA from the RTC kept at ∼1 bar. The ions are stopped in the RTC and transported by a continuous gas flow from the RTC to the ancillary setup. In this paper, we report on measurements of the transportation yields under various conditions and on the first chemistry experiments at TASCA—an electrochemistry experiment with osmium and an ion exchange experiment with the transactinide element rutherfordium.
Resumo:
Strict next-to-leading order (NLO) results for the dilepton production rate from a QCD plasma at temperatures above a few hundred MeV suffer from a breakdown of the loop expansion in the regime of soft invariant masses M 2 ≪ (πT)2. In this regime an LPM resummation is needed for obtaining the correct leading-order result. We show how to construct an interpolation between the hard NLO and the leading-order LPM expression, which is theoretically consistent in both regimes and free from double counting. The final numerical results are presented in a tabulated form, suitable for insertion into hydrodynamical codes.