998 resultados para cooling strategies


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A realistic model of the dipole radiation forces in transverse Doppler cooling (with a s+-s- laser configuration) of an atomic beam of group 13 elements is studied within the quantum-kinetic equation framework. The full energy level sub-structure for such an atom with I = 0 (such as 66Ga) is analysed. Two cooling strategies are investigated; the first involving the 2P3/2 ? 2D5/2 transition and the second a dual laser cooling experiment involving transitions 2P1/2 and 2P3/2 ? 2S1/2. The latter scheme creates a velocity-independent dark-state resonance that inhibits a steady-state dipole cooling force. However, time-dependent calculations show that transient cooling forces are present that could be exploited for laser cooling purposes in pulsed laser fields.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El presente trabajo de investigación determina las características de la cerámica que más eficientemente se comporta a evaporación y a enfriamiento. Con el objeto de ser empleado como material integrado en la envolvente de los edificios para reducir su carga de refrigeración. La cerámica es un buen material para ser empleado para la refrigeración por evaporación. Es un sólido poroso inerte que, tras ser sometido a cocción a temperaturas por encima de los 900ºC, resulta uno de los materiales que mejor se comportan como contenedor de agua en su red capilar para, posteriormente, ir liberándola por evaporación al mismo tiempo que se enfría su superficie. La metodología general de investigación, se divide en tres etapas: Búsqueda y análisis del estado de la técnica y de la investigación. Estudio teórico de la eficacia del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura. Etapa experimental, desarrollada en tres fases: una primera de definición de los parámetros determinantes del Enfriamiento Evaporativo en piezas cerámicas, una segunda de selección cerámica y diseño de ensayos experimentales y una tercera de caracterización de la cerámica bajo criterios de evaporación y de enfriamiento. El recorrido por el estado de la cuestión ha identificado las aplicaciones tecnológicas y las investigaciones científicas que emplean el Enfriamiento Evaporativo con piezas cerámicas como técnica de enfriamiento. Como resultado se ha obtenido una tabla de clasificación de sistemas de enfriamiento evaporativo y se ha constatado que el conjunto de las aplicaciones están centradas en el diseño de piezas o sistemas pero que, sin embargo, no existe una definición de las características de la cerámica para su empleo como material de enfriamiento por evaporación. El estudio teórico de la eficacia del empleo del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura se ha realizado mediante cálculos de porcentaje de ampliación de horas en confort con empleo de técnicas de enfriamiento evaporativo directo e indirecto (EED y EEI). Como resultado se obtienen unos mapas para el ámbito español de potencial de aplicación del EED y EEI. Los resultados permiten afirmar que mediante EE se puede llegar a confort en prácticamente la totalidad de las horas de los días más cálidos del año en muchas localidades. La metodología experimental se ha desarrollado en tres fases. En la fase inicial, se han definido los parámetros determinantes del enfriamiento evaporativo en un medio cerámico mediante ensayos experimentales de capacidad de evaporación y de caracterización. Se realizaron un total de 12 ensayos. Se determinó que el material cerámico tiene una gran influencia en la capacidad de evaporación y enfriamiento en las piezas cerámicas, apoyando la hipótesis inicial y la necesidad de caracterizar el material. La primera fase empírica se centró en la selección cerámica y el diseño de los ensayos experimentales de comportamiento hídrico. Se seleccionaron muestras de 5 tipos de cerámica. Se realizaron 4 tipos de ensayos de caracterización y 6 tipos de ensayos experimentales de comportamiento hídrico (total 123 muestras ensayadas). Los resultados obtenidos son de dos tipos, por un lado, se determinó cuál es el tipo de cerámica que más eficientemente se comporta a EE y, por otro, se rediseñaron los ensayos de la última fase experimental. Para la segunda fase experimental se seleccionaron cerámicas de fabricación manual abarcando el mayor número de localidades del ámbito español. Se realizaron ensayos de caracterización de 7 tipos y ensayos de comportamiento hídrico de 5 tipos (total 197 muestras ensayadas). Los resultados de caracterización han permitido aportar unos rangos de las características de la cerámica que más eficientemente se comporta en los ensayos de comportamiento hídrico. Al final de la investigación se ha caracterizado el material cerámico aportando características acerca de su porosidad, capacidad de absorción, color, rugosidad y mineralogía. Así como datos de referencia de su comportamiento hídrico. Además se ha desarrollado una metodología de ensayo específica que permite evaluar la capacidad de enfriamiento eficiente de una pieza cerámica. ABSTRACT The purpose of this research is to determine the characteristics of ceramic materials having the most efficient performance in terms of evaporation and cooling, so that they can be integrated in building envelopes to reduce cooling loads. Ceramics are suitable materials for cooling through passive evaporation. After being fired at temperatures over 900 °C (1,652 °F), the capillary network of this inert porous medium turns to be excellent to retain water, which is progressively liberated by evaporation while the material surface gets colder. Research methodology has involved the following steps: Search and analysis on the state of the art in technology and research. Theoretical study on the efficiency of evaporation as passive cooling strategies in buildings. Experimental stage developed in three phases, namely: definition of parameters determining evaporative cooling in ceramic elements; ceramic selection and design of experimental tests; characterization of ceramic materials under evaporation and cooling criteria. Search and analysis on the state of the art in this field have been useful to identify technology applications and scientific research where ceramics are employed for evaporative cooling. The resulting table shows that applications are wholly focused on the design of pieces and systems. Nonetheless, there is lack of definition of material characteristics in this scope. The theoretical study on efficiency of the passive strategy applied to buildings has been realized by calculation of the percentage increase in comfort hours through direct/indirect evaporative cooling techniques (DEC/IEC). The mapping of their potential application in Spain clearly shows that comfort conditions can be reached in almost all the hours of the hottest days in many towns. In the initial phase of the experimental stage, parameters determining evaporative cooling in ceramic media have been defined. For this purpose, characterization tests and evaporation and cooling rates experiments have been carried out; the number of samples tested amounted to 12. It has been concluded that material characteristics have great influence on these rates, which supports the initial hypothesis and the need for their characterization. The first empirical phase has focused on ceramic selection and design of water behaviour experimental methods. The samples covered five different kinds of ceramic materials. Four different characterization tests and six different water behaviour experiments were carried out; the number of samples tested amounted to 123. The experimental testing procedures served to determine the most efficient types of ceramic materials in terms of evaporative cooling efficiency and, at the same time, made it necessary to change the original designed experimental test for the last phase. In the second phase, a number of varied hand-made ceramic tiles have been selected. Seven different characterization tests and five different water behaviour tests were carried out; the number of samples amounted to 197. The results of characterization served to establish a range of features in ceramic materials according to their efficiency in water behaviour experiments. Finally, ceramic materials have been characterized according to porosity, water absorption, colour, surface roughness and mineralogy. Also, reference data regarding water behaviour have been included. Moreover, an innovative and specific experimental test to evaluate cooling efficiency of ceramic tiles has been developed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil no Ramo de Edificações

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a holistic approach to comfort and greenhouse gas emissions in mixed mode offices. It is based on parametric studies for a typical cellular office in the Mediterranean climate of Athens, Greece, using building simulation.

Considered parameters are the influence of different building design, varying occupant behaviour and internal heat loads, as well as of an exceptionally hot summer. Additionally, the performance of a cooling strategy following the comfort limits according to the EN 15251 adaptive model is compared with the common fixed cooling set point 22°C.

The performance of mixed mode offices is evaluated regarding thermal comfort, daylight autonomy and related greenhouse gas emissions. Results indicate strategies to improve sustainability in mixed mode offices in Athens, by balancing the influencing parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article investigates the context dependency of comfort and energy performance in mixed-mode offices in the climate of Athens, Greece. It is based on a parametric study using the simulation software EnergyPlus. Context refers to different building design priorities on the real estate market (prestige, low cost and green), occupant behaviour scenarios (ideal and worst case) and cooling strategies (fixed and adaptive set points). Results are evaluated according to energy consumption and related greenhouse gas emissions, daylight autonomy, view and percentage of working time when heating and cooling are operating. The results indicate that a holistic approach to comfort and energy performance evaluation focused on the specific context of a building and its occupants is necessary to develop appropriate optimization strategies. In early design stages, such specific information is not yet available and ideal/worst-case scenarios can indicate the magnitude of influence of occupants compared to building design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the effects of a low-frequency electrical stimulation (LFES; Veinoplus® Sport, Ad Rem Technology, Paris, France), a low-frequency electrical stimulation combined with a cooling vest (LFESCR) and an active recovery combined with a cooling vest (ACTCR) as recovery strategies on performance (racing time and pacing strategies), physiologic and perceptual responses between two sprint kayak simulated races, in a hot environment (∼32 wet-bulb-globe temperature). Eight elite male kayakers performed two successive 1000-m kayak time trials (TT1 and TT2), separated by a short-term recovery period, including a 30-min of the respective recovery intervention protocol, in a randomized crossover design. Racing time, power output, and stroke rate were recorded for each time trial. Blood lactate concentration, pH, core, skin and body temperatures were measured before and after both TT1 and TT2 and at mid- and post-recovery intervention. Perceptual ratings of thermal sensation were also collected. LFESCR was associated with a very likely effect in performance restoration compared with ACTCR (99/0/1%) and LFES conditions (98/0/2%). LFESCR induced a significant decrease in body temperature and thermal sensation at post-recovery intervention, which is not observed in ACTCR condition. In conclusion, the combination of LFES and wearing a cooling vest (LFESCR) improves performance restoration between two 1000-m kayak time trials achieved by elite athletes, in the heat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a typical thermoelectric device, a junction is formed from two different conducting materials, one containing positive charge carriers (holes) and the other negative charge carriers (electrons). When an electric current is passed in the appropriate direction through the junction, both types of charge carriers move away from the junction and convey heat away, thus cooling the junction. Similarly, a heat source at the junction causes carriers to flow away from the junction, making an electrical generator. Such devices have the advantage of containing no moving parts, but low efficiencies have limited their use to specialty applications, such as cooling laser diodes. The principles of thermoelectric devices are reviewed and strategies for increasing the efficiency of novel materials are explored. Improved materials would not only help to cool advanced electronics but could also provide energy benefits in refrigeration and when using waste heat to generate electrical power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The probabilistic projections of climate change for the United Kingdom (UK Climate Impacts Programme) show a trend towards hotter and drier summers. This suggests an expected increase in cooling demand for buildings – a conflicting requirement to reducing building energy needs and related CO2 emissions. Though passive design is used to reduce thermal loads of a building, a supplementary cooling system is often necessary. For such mixed-mode strategies, indirect evaporative cooling is investigated as a low energy option in the context of a warmer and drier UK climate. Analysis of the climate projections shows an increase in wet-bulb depression; providing a good indication of the cooling potential of an evaporative cooler. Modelling a mixed-mode building at two different locations, showed such a building was capable of maintaining adequate thermal comfort in future probable climates. Comparing the control climate to the scenario climate, an increase in the median of evaporative cooling load is evident. The shift is greater for London than for Glasgow with a respective 71.6% and 3.3% increase in the median annual cooling load. The study shows evaporative cooling should continue to function as an effective low-energy cooling technique in future, warming climates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to exploit the passive energy potential of the building envelope, it is important to provide a right combination of insulation thickness, heat capacity and night-time ventilation. In this paper, this issue will be tackled with reference to an historic building in Catania (Southern Italy). The building was built at the end of the XIX century, and its opaque envelope is entirely made with lava stones, which is typical of traditional architecture in this area. Starting from the current configuration of the building, many hypotheses for refurbishment are considered, combined with different strategies for passive cooling, such as night-time ventilation, use of shading devices and adoption of highly-reflective coatings. The effectiveness of each solution in terms of summer thermal comfort is evaluated through dynamic thermal simulations carried out with EnergyPlus. The results show the synergic effect of these strategies, as well as their individual impact, and allow to draw some general conclusions about the behaviour of heavyweight buildings under moderately hot weather conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-rise apartments provide 90% of the living requirements in Hong Kong. (Lam 1995) The construction material of these buildings is primarily concrete for both external wall and interior partitions with little or no thermal insulation. Due to the hot and humid climatic conditions and expectations of an ever-increasing standard of living, occupants are installing air-conditioning systems into their apartments. This has generated a tremendous electrical demand as well as an environmental (greenhouse gas emission) concern. This paper explores some of the low energy strategies that can be applied to this building typology. The effect of seven energy-saving strategies ranging from thermal insulation to different window systems and shading devices was investigated. The results show that there is the potential to reduce the annual cooling energy consumption and peak cooling load by 40% and 33% respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevention of ischaemia and the adequate restitution of blood flow to ischaemic tissue are pivotal to halt the progression of cellular injury associated with decreased oxygen and nutrient supply. Accordingly, the search for novel strategies which aim at preventing ischaemia-reperfusion-induced tissue damage is still of major interest in flap surgery. Preconditioning represents an elegant approach to render the tissue more resistant against deleterious ischaemic insults. For many decades, 'surgical delay' has been the standard method of tissue preconditioning. During the last 10 years, ischaemic preconditioning was added to the repertoire of plastic surgeons to protect flaps from ischaemic necrosis. The invasiveness and expenditure of time of these procedures, however, have always been major drawbacks, hindering a wide distribution in clinical practice. Consequently, the motivation has all along been to further refine and simplify protective strategies. Recent experimental studies have now shown that efficient protection from ischaemic necrosis can also be achieved by remote preconditioning or pretreatment with chemical agents and growth factors, which mimic the action of surgical delay and ischaemic preconditioning. In addition, the local application of unspecific stressors, including both heating and cooling, have been shown to effectively improve flap microcirculation and, thus, tissue survival. In view of successful translational research, it is now time that the efficacy of these novel preconditioning procedures is proven in prospective randomised clinical trials.