885 resultados para contrast sensitivity
Resumo:
PURPOSE: To explore the effects of glaucoma and aging on low-spatial-frequency contrast sensitivity by using tests designed to assess performance of either the magnocellular (M) or parvocellular (P) visual pathways. METHODS: Contrast sensitivity was measured for spatial frequencies of 0.25 to 2 cyc/deg by using a published steady- and pulsed-pedestal approach. Sixteen patients with glaucoma and 16 approximately age-matched control subjects participated. Patients with glaucoma were tested foveally and at two midperipheral locations: (1) an area of early visual field loss, and (2) an area of normal visual field. Control subjects were assessed in matched locations. An additional group of 12 younger control subjects (aged 20-35 years) were also tested. RESULTS: Older control subjects demonstrated reduced sensitivity relative to the younger group for the steady (presumed M)- and pulsed (presumed P)-pedestal conditions. Sensitivity was reduced foveally and in the midperiphery across the spatial frequency range. In the area of early visual field loss, the glaucoma group demonstrated further sensitivity reduction relative to older control subjects across the spatial frequency range for both the steady- and pulsed-pedestal tasks. Sensitivity was also reduced in the midperipheral location of "normal" visual field for the pulsed condition. CONCLUSIONS: Normal aging results in a reduction of contrast sensitivity for the low-spatial-frequency-sensitive components of both the M and P pathways. Glaucoma results in a further reduction of sensitivity that is not selective for M or P function. The low-spatial-frequency-sensitive channels of both pathways, which are presumably mediated by cells with larger receptive fields, are approximately equivalently impaired in early glaucoma.
Resumo:
To determine the age-related change in the peripheral short-wavelength-sensitive (SWS) grating contrast sensitivity function (CSF), cut-off spatial frequency (acuity) and contrast sensitivity for both a detection and resolution task were measured at 8 degrees eccentricity under conditions of SWS-cone isolation for 51 subjects (19-72 years). The acuity for both the detection and resolution task declined with age, the detection acuity being significantly higher than the resolution acuity at all ages (p
Resumo:
What is the best luminance contrast weighting-function for image quality optimization? Traditionally measured contrast sensitivity functions (CSFs), have been often used as weighting-functions in image quality and difference metrics. Such weightings have been shown to result in increased sharpness and perceived quality of test images. We suggest contextual CSFs (cCSFs) and contextual discrimination functions (cVPFs) should provide bases for further improvement, since these are directly measured from pictorial scenes, modeling threshold and suprathreshold sensitivities within the context of complex masking information. Image quality assessment is understood to require detection and discrimination of masked signals, making contextual sensitivity and discrimination functions directly relevant. In this investigation, test images are weighted with a traditional CSF, cCSF, cVPF and a constant function. Controlled mutations of these functions are also applied as weighting-functions, seeking the optimal spatial frequency band weighting for quality optimization. Image quality, sharpness and naturalness are then assessed in two-alternative forced-choice psychophysical tests. We show that maximal quality for our test images, results from cCSFs and cVPFs, mutated to boost contrast in the higher visible frequencies.
Resumo:
We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.
Resumo:
The purpose of this study was to compare contrast sensitivity estimated from transient visual evoked potentials (VEPs) elicited by achromatic pattern-reversal and pattern-onset/offset modes. The stimuli were 2-cpd, achromatic horizontal gratings presented either as a 1 Hz pattern reversal or a 300 ms onset/700 ms offset stimulus. Contrast thresholds were estimated by linear regression to amplitudes of VEP components vs. the logarithm of the stimulus contrasts, and these regressions were extrapolated to the zero amplitude level. Contrast sensitivity was defined as the inverse of contrast threshold. For pattern reversal, the relation between the P100 amplitude and log of the stimulus contrast was best described by two separate linear regressions. For the N135 component, a single straight line was sufficient. In the case of pattern onset/offset for both the C1 and C2 components, single straight lines described their amplitude vs. log contrast relations in the medium-to-low contrast range. Some saturation was observed for C2 components. The contrast sensitivity estimated from the low-contrast limb of the P100, from the N135, and from the C2 were all similar but higher than those obtained from the high-contrast limb of the P100 and C1 data, which were also similar to each other. With 2 cpd stimuli, a mechanism possibly driven by the M pathway appeared to contribute to the P100 component at medium-to-low contrasts and to the N135 and C2 components at all contrast levels, whereas another mechanism, possibly driven by the P and M pathways, appeared to contribute to the P100 component at high contrast and C1 component at all contrast levels.
Resumo:
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.
Resumo:
The luminance contrast sensitivity function has been investigated using behavioral and electrophysiological methods in many vertebrate species. Some features are conserved across species as a shape of the function, but other features, such as the contrast sensitivity peak value, spatial frequency contrast sensitivity peak, and visual acuity have changed. Here, we review contrast sensitivity across different classes of vertebrates, with an emphasis on the frequency contrast sensitivity peak and visual acuity. We also correlate the data obtained from the literature to test the power of the association between visual acuity and the spatial frequency of the contrast sensitivity function peak.
Resumo:
Contrast sensitivity (CS) was evaluated in 41 former workers from a lamp manufacturing plant who were on disability retirement due to exposure to mercury and 14 age-matched controls. The CS was measured monocularly using the sweep visual evoked potential (sVEP) paradigm at 6 spatial frequencies (0.2, 0.8, 2.0, 4.0, 15.0, and 30 cpd). Statistical difference (p < 0.05) was found between the controls and the patient right and left eyes for 2.0 and 4.0 cpd. According the results in those spatial frequencies the eyes were classified in best and worst. Statistical differences were found between the controls and the best eyes for 2.0 and 4.0 cpd and for 0.8, 2.0, and 4.0 cpd for their worst eyes. No correlation was found between CS results and the time of exposure (mean 8.9 yr +/- 4.1), time away from the mercury source (mean = 6.0 yr +/- 3.9), urinary mercury level at the time of work (mean = 40.6 mu g/g +/-36.3) or with the mercury level at the CS measurement time (mean = 1.6 mu g/g +/-1.1). We show the first evidence of a permanent impairment in CS measured objectively with the sVEP. Our data complement the previous psychophysical works reporting a diffuse impairment in the CS function showing a CS reduction in the low to middle spatial frequencies. In conclusion, non-reversible CS impairment was found in occupational exposure to mercury vapor. We suggest that CS measurement should be included in studies of the mercury effects of occupational exposure. (C) 2007 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE. To evaluate achromatic contrast sensitivity (CS) with magnocellular-(M) and parvocellular-(P) probing stimuli in type 2 diabetics, with (DR) or without (NDR) nonproliferative retinopathy. METHODS. Inferred M-and P-dominated responses were assessed with a modified version of the steady-/pulsed-pedestal paradigm (SP/PP) applied in 26 NDR (11 male; mean age, 55 +/- 9 years; disease duration, 5 +/- 4 years); 19 DR (6 male; mean age, 58 +/- 7 years; disease duration = 9 +/- 6 years); and 18 controls (CTRL; 12 male; mean age, 55 +/- 10 years). Thresholds were measured with pedestals at 7, 12, and 19 cd/m(2), and increment durations of 17 and 133 ms. The thresholds from the two stimulus durations were used to estimate critical durations (Tc) for each data set. RESULTS. Both DR and NDR patients had significant reduction in CS in both SP and PP paradigms in relation to CTRL (Kruskal-Wallis, P < 0.01). Patients` critical duration estimates for either paradigm were not significantly different from CTRL. CONCLUSIONS. The significant reduction of CS in both paradigms is consistent with losses of CS in both M and P pathways. The CS losses were not accompanied by losses in temporal processing speed in either diabetic group. Significant CS loss in the group without retinopathy reinforces the notion that neural changes associated with the cellular and functional visual loss may play an important role in the etiology of diabetic visual impairment. In addition, the results show that the SP/PP paradigm provides an additional tool for detection and characterization of the early functional damage due to diabetes. (Invest Ophthalmol Vis Sci. 2011; 52:1151-1155) DOI:10.1167/iovs.09-3705
Resumo:
The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.
Resumo:
Purpose: To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. Methods: Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injection. Patients were submitted to a complete evaluation including best corrected visual acuity, contrast sensitivity and optical coherence tomography measurements before treatment and one and three months after injection. Visual acuity, contrast sensitivity and optical coherence tomography measurements were compared to baseline values. Results: Mean visual acuity measurement improved from 0.77 logMAR at baseline to 0.613 logMAR one month after injection (P=0.0001) but worsened to 0.75 logMAR after three months. Contrast sensitivity test demonstrated significant improvement at spatial frequencies of 3, 6, 12 and 18 cycles/degree one month after injection and at the spatial frequency of 12 cycles/degree three months after treatment. Mean +/- standard deviation baseline central macular thickness (552 +/- 150 mu m) reduced significantly one month (322 +/- 127 mu m, P=0.0001) and three months (439 perpendicular to 179 mu m, P=0.01) after treatment. Conclusions: Bevacizumab injection improves visual acuity and contrast sensitivity and reduces central macular thickness one month after treatment. Visual acuity returns to baseline levels at the 3-month follow-up, but some beneficial effect of the treatment is still present at that time, as evidenced by optical coherence tomography-measured central macular thickness and contrast sensitivity measurements.
Resumo:
Early malnutrition refers to inadequate nutrition during the critical period of nervous system development followed by nutritional recovery, resulting in a short stature according to age but normal weight according to short stature. We measured the effects of early malnutrition on contrast sensitivity (CS) to concentric circular gratings in 18 children of both sexes, aged 8 to 11 years (mean = 9.2 years, standard deviation = .99 years). Nine of the children were eutrophic (E group), and nine experienced early malnutrition (EM group) based on state healthcare records and Waterlow's anthropometric parameters. Contrast sensitivity to four spatial frequencies (.25, 1.0, 2.0, and 8.0 cycles per degree [cpd]) was measured using a temporal two-alternative forced-choice psychophysical method with mean luminance of 40.1 cd/m². Statistical analyses showed significant differences between groups and a group × frequency interaction. EM group was significantly less sensitive than the E group to the 8.0 cpd frequency and needed 1.49-times more contrast to detect the gratings. These results suggest that early malnutrition impairs CS to high-spatial-frequency concentric circular gratings in children. Therefore, early malnutrition, which is known to affect primary visual cortical areas, may also affect higher visual cortical areas such as V4 and the inferotemporal cortex.
Resumo:
The aim of this study was to evaluate the visual acuity of adult zebrafish by assessing the optokinetic reflex. Using a modified commercially available optomotor device (OptoMotry®), virtual three-dimensional gratings of variable spatial frequency or contrast were presented to adult zebrafish. In a first experiment, visual acuity was evaluated by changing the spatial frequency at different angular velocities. Thereafter, contrast sensitivity was evaluated by changing the contrast level at different spatial frequencies.