896 resultados para contrast medium


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The involvement of nephrotoxic agents in acute renal failure (ARF) has increased over the last few decades. Among the drugs associated with nephrotoxic ARF are the radiologic contrast media whose nephrotoxic effects have grown, following the increasing diagnostic use of these agents. Methods: We evaluated the effect of iodinated contrast (IC) medium, administered in combination, or not, with hyperhydration or N-acetylcysteine (NAC), on creatinine clearance, production of urinary peroxides and renal histology of rats. Adult Wistar rats treated for 5 days were divided into the following groups: control (saline, 3 ml/kg/day, intraperitoneally [i.p.]), IC (sodium iothalamate meglumine, 3 ml/kg/day i.p.), IC + water (12 mL water, orally + IC, 3 ml/kg/day i.p. after 1 hour), IC + NAC (NAC, 150 mg/kg/day, orally + IC, 3 ml/kg/day i.p. after 1 hour) and IC + water + NAC. Results: IC medium reduced renal function, with maintenance of urinary flow. Hyperhydration did not reduce the nephrotoxic effect of the IC agent, which was observed in the group IC + NAC. The combination of hyperhydration and NAC had no superior protective effect compared with NAC alone. An increase in urinary peroxides was observed in the IC group, with NAC or water or the combination of both reducing this parameter. Histopathologic analysis revealed no significant alterations. Conclusions: In summary, given 5 days previously, NAC was found to be more effective than hyperhydration alone in the prevention of contrast-induced acute renal failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem angiography methods that use water soluble or lipid soluble liquid contrast compounds may potentially modify the composition of fluid-based biological samples and thus influence toxicological findings. In this study, we investigated whether toxicological investigations performed in urine collected prior to and post angiography using Angiofil? mixed with paraffin oil are characterized by different qualitative or quantitative results. In addition, we studied whether diluting samples with 1% and 3% contrast medium solution may modify molecule concentration. A postmortem angiography group consisting of 50 cases and a postmortem group without angiography consisting of 50 cases were formed. In the first group, toxicological investigations were performed in urine samples collected prior to and post angiography as well as in undiluted and diluted samples. In the second group, analyses were performed in undiluted and diluted urine, bile, gastric content, cerebrospinal and pericardial fluids collected during autopsy. The preliminary results indicate that differences may be observed between urine samples collected prior to and post angiography in the number of identified molecules in relation to specific cases. Analyses performed in diluted samples failed to reveal differences that might potentially alter the interpretation of toxicological results in all analyzed specimens for nearly all molecules, except for tetrahydrocannabinol and its metabolites. Though these findings suggest that toxicology might be effectively performed, in very special cases and for a large number of molecules, in biological samples collected after angiography, it remains recommendable to collect biological fluids for toxicology prior to contrast medium injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have demonstrated that the use of paramagnetic hepatobiliary contrast agents in the acquisition of magnetic resonance images remarkably improves the detection and differentiation of focal liver lesions, as compared with extracellular contrast agents. Paramagnetic hepatobiliary contrast agents initially show the perfusion of the lesions, as do extracellular agents, but delayed contrast-enhanced images can demonstrate contrast uptake by functional hepatocytes, providing further information for a better characterization of the lesions. Additionally, this intrinsic characteristic increases the accuracy in the detection of hepatocellular carcinomas and metastases, particularly the small-sized ones. Recently, a hepatobiliary contrast agent called gadolinium ethoxybenzyl dimeglumine, that is simply known as gadoxetic acid, was approved by the National Health Surveillance Agency for use in humans. The authors present a literature review and a practical approach of magnetic resonance imaging utilizing gadoxetic acid as contrast agent, based on patients' images acquired during their initial experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine if radiocontrast impairs vascular relaxation of the renal artery, segments (4-5 mm in length) of canine renal artery were suspended in vitro in organ chambers to measure isometric force (95% O2/5% CO2, at 37ºC). Arterial segments with and without endothelium were placed at the optimal point of their length-tension relation and incubated with 10 µM indomethacin to prevent synthesis of endogenous prostanoids. The presence of nonionic radiocontrast (iohexol, Omnipaque 350, 1 ml in 25 ml control solution, 4% (v/v)) did not alter endothelium-dependent relaxation to acetylcholine in rings precontracted with both norepinephrine and prostaglandin F2alpha (N = 6). When the rings were precontracted with prostaglandin F2alpha, the presence of ionic contrast did not inhibit the relaxation of the arteries. However, in canine renal arteries contracted with norepinephrine, the presence of ionic radiocontrast (diatrizoate meglumine and diatrizoate sodium, MD-76, 1 ml in 25 ml control solution, 4% (v/v)) inhibited relaxation in response to acetylcholine, sodium nitroprusside (N = 6 in each group), and isoproterenol (N = 5; P < 0.05). Rings were relaxed less than 50% of norepinephrine contraction. Following removal of the contrast, vascular relaxation in response to the agonists returned to normal. These results indicate that ionic radiocontrast nonspecifically inhibits vasodilation (both cAMP-mediated and cGMP-mediated) of canine renal arteries contracted with norepinephrine. This reversible impairment of vasodilation could inhibit normal renal perfusion and act as a mechanism of renal failure following radiocontrast infusion. In the adopted experimental protocol the isoproterenol-induced relaxation of renal arteries precontracted with norepinephrine was more affected, suggesting a pivotal role of the cAMP system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to assess experimentally the usefulness of some procedures employed in man to prevent venous thrombosis following phlebography, thrombosis was induced in rats using sodium diatrizoate in a temporarily isolated segment of a jugular vein. The prevention of thrombosis was attempted by washing out the vein with physiologic saline or saline plus heparin or by injecting saline plus heparin in the opposite jugular vein. Thrombosis occurred in all animals in the control group and in the group treated with saline alone. Both treatment schemes with heparin significantly reduced the incidence of thrombosis, the wash out with heparin being more effective than systemic heparin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lo scopo di questa tesi è lo studio degli aspetti procedurali e dosimetrici in angiografie periferiche che utilizzano la CO2 come mezzo di contrasto. La tecnica angiografica consiste nell’imaging radiologico di vasi sanguigni tramite l’iniezione di un mezzo di contrasto, e il suo uso è in costante incremento a causa dell’aumento di pazienti con malattie vascolari. I mezzi di contrasto iodati sono i più comunemente utilizzati e permettono di ottenere immagini di ottima qualità, ma presentano il limite di una elevata nefrotossicità. La CO2 è considerata un’interessante alternativa al mezzo iodato, per la sua acclarata biocompatibilità, soprattutto per pazienti con elevati fattori di rischio (diabete e/o insufficienza renale). Il suo utilizzo presenta comunque alcuni aspetti problematici, dovuti allo stato gassoso e al basso contrasto intrinseco rispetto alla soluzione iodata. Per quest’ultimo motivo si ritiene generalmente che l’utilizzo della CO2 comporti un aumento di dose rispetto ai mezzi di contrasto tradizionali. Il nostro studio, effettuato su diversi apparati radiologici, ha dimostrato che i parametri di emissione radiologica sono gli stessi per i protocolli di angiografia tradizionale, con iodio, e quelli che utilizzano CO2. Questa evidenza suggerisce che i protocolli CO2 operino solo sul trattamento delle immagini ottenute e non sulla modalità di acquisizione, e dal punto di vista dosimetrico l’angiografia con CO2 è riconducibile all’angiografia tradizionale. L’unico fattore che potrebbe portare a un effettivo incremento di dose al paziente è un allungamento dei tempi di scopia e di procedura, che andrebbe verificato con una campagna di misure in ambito clinico. Sulla base della stessa evidenza, si ritiene che la visualizzazione della CO2 possa essere ulteriormente migliorata attraverso l’ottimizzazione dei parametri di emissione radiologica (kVp, frame rate e durata degli impulsi) attualmente predisposti per l’uso di mezzi di contrasto iodati.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The radiological depiction of stab wounds in soft-tissues using multislice computed tomography is difficult and the hereby obtained images often lack contrast. To overcome these shortcomings we tried a new method. We gently instilled the contrast medium Lipiodol((R)) Ultra-fluide into five experimentally induced stab wounds on a pork haunch. Subsequent MSCT reconstructions of the wounds delivered clear, for medical laymen easily appreciable images regarding the stab direction and the stab depth. We believe that this easy and rapid technique can be useful in the examination of stab wounds in living and dead victims of sharp trauma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Evidence-based information is limited on distribution of local anaesthetic solution following perineural analgesia of the palmar (Pa) and palmar metacarpal (PaM) nerves in the distal aspect of the metacarpal (Mc) region ('low 4-point nerve block'). OBJECTIVES: To demonstrate the potential distribution of local anaesthetic solution after a low 4-point nerve block using a radiographic contrast model. METHODS: A radiodense contrast medium was injected subcutaneously over the medial or the lateral Pa nerve at the junction of the proximal three-quarters and distal quarter of the Mc region (Pa injection) and over the ipsilateral PaM nerve immediately distal to the distal aspect of the second or fourth Mc bones (PaM injection) in both forelimbs of 10 mature horses free from lameness. Radiographs were obtained 0, 10 and 20 min after injection and analysed subjectively and objectively. Methylene blue and a radiodense contrast medium were injected in 20 cadaver limbs using the same techniques. Radiographs were obtained and the limbs dissected. RESULTS: After 31/40 (77.5%) Pa injections, the pattern of the contrast medium suggested distribution in the neurovascular bundle. There was significant proximal diffusion with time, but the main contrast medium patch never progressed proximal to the mid-Mc region. The radiological appearance of 2 limbs suggested that contrast medium was present in the digital flexor tendon sheath (DFTS). After PaM injections, the contrast medium was distributed diffusely around the injection site in the majority of the limbs. In cadaver limbs, after Pa injections, the contrast medium and the dye were distributed in the neurovascular bundle in 8/20 (40%) limbs and in the DFTS in 6/20 (30%) of limbs. After PaM injections, the contrast and dye were distributed diffusely around the injection site in 9/20 (45%) limbs and showed diffuse and tubular distribution in 11/20 (55%) limbs. CONCLUSIONS AND POTENTIAL RELEVANCE: Proximal diffusion of local anaesthetic solution after a low 4-point nerve block is unlikely to be responsible for decreasing lameness caused by pain in the proximal Mc region. The DFTS may be penetrated inadvertently when performing a low 4-point nerve block.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P < 0.001), homogeneity of the luminal content (P < 0.001), delineation of the bowel-wall to the lumen (P < 0.001) and to the mesentery (P < 0.001) and artifacts (P < 0.001), leading to a significant better overall image quality (P < 0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P < 0.001) and wall to lumen delineation (P < 0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Proximal diffusion of local anaesthetic solution after perineural anaesthesia may lead to the desensitisation of structures other than those intended. However, there is no evidence-based study demonstrating the potential distribution and diffusion of local anaesthetic solution after perineural analgesia in the distal limb. OBJECTIVE: To document the potential diffusion of local anaesthetic solution using a radiopaque contrast model and to evaluate the influence of walking compared with confinement in a stable after injection. METHODS: Radiopaque contrast medium was injected subcutaneously over one palmar nerve at the base of the proximal sesamoid bones in 6 nonlame mature horses. Horses were assigned randomly to stand still or walk after injection. Radiographs were obtained 0, 5, 10, 15, 20 and 30 min after injection and were analysed to determine the distribution and diffusion of the contrast medium. RESULTS: In 89% of injections an elongated pattern of the contrast medium was observed suggesting distribution along the neurovascular bundle. After 49% of injections a fine radiopaque line extended proximally from the contrast 'patch', and in 25% of injections a line extended distally. There was significant proximal and distal diffusion with time when sequential radiographs of each limb were compared. The greatest diffusion occurred in the first 10 min. Walking did not significantly influence the extent of either proximal or distal diffusion. CONCLUSIONS AND POTENTIAL RELEVANCE: Significant proximal diffusion occurs in the first 10 min after perineural injection in the distal aspect of the limb and should be considered when interpreting nerve blocks. Distribution of local anaesthetic solution outside the fascia surrounding the neurovascular bundle or in lymphatic vessels may explain delayed or decreased effects.