999 resultados para contact hour


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Urquhart, C. (editor for JUSTEIS team), Spink, S., Thomas, R., Yeoman, A., Durbin, J., Turner, J., Armstrong, A., Lonsdale, R. & Fenton, R. (2003). JUSTEIS (JISC Usage Surveys: Trends in Electronic Information Services) Strand A: survey of end users of all electronic information services (HE and FE), with Action research report. Final report 2002/2003 Cycle Four. Aberystwyth: Department of Information Studies, University of Wales Aberystwyth with Information Automation Ltd (CIQM). Sponsorship: JISC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo pretende ser uma contribuição para a resposta aos apelos desafiadores de diversos autores e organizações internacionais, em particular das Nações Unidas, ao reconhecerem a importância da educação para a sustentabilidade através da proposta da Década da Educação para o Desenvolvimento Sustentável (2005-2014). A formação contínua de professores desenvolvida em comunidades de aprendizagem interdisciplinares, constituídas por professores de Ciências e de Filosofia, foi assumida nesta investigação com um instrumento que pode potenciar o incremento da interdisciplinaridade entre estas áreas do saber e promover o desenvolvimento profissional dos professores. O estudo realizado centra-se em três fases: Fase I – Diagnóstico de concepções de professores de Ciências e de Filosofia acerca da pertinência que atribuem às interacções intergrupais (Ciências/Filosofia) como contributo para a melhoria das suas práticas pedagógicas e das aprendizagens dos alunos no âmbito da educação para a sustentabilidade. Fase II – Concepção e implementação de um programa de formação contínua numa comunidade de aprendizagem interdisciplinar, constituída por professores de Ciências e de Filosofia de uma escola. Fase III – Avaliação das percepções dos professores/formandos sobre os impactes do programa de formação no incremento da interdisciplinaridade, na leccionação da temática Sustentabilidade na Terra, no desenvolvimento profissional dos participantes e nas práticas de formação contínua de professores. A Fase I incide sobre o diagnóstico de concepções de professores de Ciências e de Filosofia, para o qual foi concebido um questionário, aplicado em dezoito escolas do Ex-CAE de Viseu, e ao qual responderam 185 professores. Os indicadores obtidos revelam que os professores de Ciências e de Filosofia reconhecem a relevância das suas próprias áreas disciplinares para a formação dos alunos. No entanto, a interdisciplinaridade entre as Ciências e a Filosofia é escassa, apesar dos professores considerarem que pode ser útil na planificação das actividades lectivas. Consideram, também, que pode promover a implementação de estratégias de ensino mais diversificadas e contribuir para o incremento de uma cultura de colaboração nas escolas. Os professores de Ciências e de Filosofia reconhecem que a abordagem da temática Sustentabilidade na Terra necessita de conceitos para além dos que são abordados individualmente nas disciplinas leccionadas e pode ser facilitada se forem implementados materiais didácticos construídos com colegas do seu e de outros grupos disciplinares. A Fase II parte das concepções diagnosticadas, dos indicadores da investigação em Didáctica, das actuais perspectivas de ensino e de aprendizagem preconizadas para os Ensinos Básico e Secundário e de um modelo de formação reflexiva, crítica e ecológica (Bronfenbrenner, 1979; Alarcão, 1996; Sá-Chaves, 1997; Schön, 2000) e elabora-se um programa de formação contínua de professores de cariz interdisciplinar (Ciências e Filosofia). Este programa de formação foi implementado a vinte e quatro professores de Ciências e de Filosofia de uma Escola Secundária da região Centro-Norte de Portugal, durante o ano lectivo de 2008/2009 e teve a duração de cinquenta horas presenciais e cinquenta horas não presenciais. Nele aprofundam-se conhecimentos no âmbito da educação em Ciência e em Filosofia, promovendo a ligação entre ambas e facilitando, deste modo, a sua transposição didáctica. Promove-se a articulação entre a investigação e as práticas pedagógicas e proporciona-se a análise e o aprofundamento de temáticas transversais às Ciências e à Filosofia. Procura-se, deste modo, potenciar a especificidade das áreas do saber envolvidas e promover o enriquecimento de perspectivas nos participantes. Das dinâmicas estabelecidas emergem percursos formativos que permitem a construção de materiais didácticos, estruturados numa perspectiva construtivista de cariz interdisciplinar, para a temática Sustentabilidade da Terra, leccionada nas disciplinas de Ciências (Ensino Básico e Secundário) e de Filosofia (Ensino Secundário). Estes materiais didácticos são, posteriormente, implementados pelos professores de Ciências e Filosofia no contexto de sala de aula. Na Fase III desta investigação avaliam-se as percepções sobre os impactes do programa de formação no incremento da interdisciplinaridade entre os professores de Ciências e de Filosofia, na leccionação da temática Sustentabilidade na Terra, no desenvolvimento profissional dos professores que nele participaram e na melhoria das práticas de formação contínua de professores. Os indicadores obtidos apontam no sentido de que o processo formativo experienciado contribuiu para: - ajudar a derrubar barreiras disciplinares existentes entre os professores de Ciências e de Filosofia; - a construção, numa lógica interdisciplinar, de materiais didácticos diversificados para a temática Sustentabilidade na Terra, que foram reconhecidos pelos alunos como inovadores e importantes para a vivência de aprendizagens activas e contextualizadas; - a modificação de algumas práticas pedagógicas dos professores participantes; - a identificação de potencialidades das comunidades de aprendizagem interdisciplinares na formação contínua de professores. As conclusões obtidas nesta investigação levam a considerar que há necessidade de serem trilhados novos caminhos no campo da formação contínua de professores, procurando criar mecanismos de trabalho e de cooperação que permitam uma efectiva partilha de saberes e de valores entre professores de diferentes áreas disciplinares, que informem novas atitudes, reais e consentâneas com uma prática pedagógica reflexiva e interdisciplinar. Deste modo, considera-se que a adopção de um modelo reflexivo de formação contínua de professores, baseado na constituição de comunidades de aprendizagem interdisciplinares, ajuda os professores a terem uma visão mais integradora dos saberes e a reconhecerem as potencialidades da interdisciplinaridade entre as Ciências e a Filosofia na melhoria das práticas pedagógicas. Pode, também, constituir-se como resposta aos desafios da educação no século XXI, facilitando o exercício de uma cidadania de responsabilidade e participativa e apontando perspectivas para a resolução de problemas da sociedade actual, entre os quais se incluem os relacionados com a sustentabilidade do planeta Terra.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper investigates undergraduate programs in electrical and electronics engineering offered by twelve universities in Australia, Asia, Europe, and America. The investigation focuses on the structure and content of the programs, and the contact hour and assessment of the subjects involved in the programs. The investigation is carried out in four stages: selection of universities, collection of data, analysis of data, and formulation of outcomes. A list of subjects is created based on the content of the programs. The average percentage coverage of each subject in the twelve programs is calculated. The subjects are then grouped into nine program components. The average percentage coverage of each component per university is calculated. For each component, the total number of contact hours for lecture, tutorial, and practical is calculated. Also, the average percentage of four assessment methods for each component is found. Discussions on the outcome of the investigation are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations. Methods Scheimpflug imaging was captured before, immediately following and 3 hours after a short period (3 hours) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear. Results Small but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels three hours after lens removal. During the three hour recovery period significant corneal thinning (-13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = -0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean -0.144 ± 0.075 μm, p = 0.02). Conclusions Flattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand hygiene is critical in the healthcare setting and it is believed that methicillin-resistant Staphylococcus aureus (MRSA), for example, is transmitted from patient to patient largely via the hands of health professionals. A study has been carried out at a large teaching hospital to estimate how often the gloves of a healthcare worker are contaminated with MRSA after contact with a colonized patient. The effectiveness of handwashing procedures to decontaminate the health professionals' hands was also investigated, together with how well different healthcare professional groups complied with handwashing procedures. The study showed that about 17% (9–25%) of contacts between a healthcare worker and a MRSA-colonized patient results in transmission of MRSA from a patient to the gloves of a healthcare worker. Different health professional groups have different rates of compliance with infection control procedures. Non-contact staff (cleaners, food services) had the shortest handwashing times. In this study, glove use compliance rates were 75% or above in all healthcare worker groups except doctors whose compliance was only 27%.