916 resultados para constructed wetlands
Potential of constructed wetlands in treating the eutrophic water: Evidence from Taihu Lake of China
Resumo:
Microorganisms play an important role in removing pollutants from constructed wetlands. We investigated the microbial characteristics in a novel integrated vertical-flow constructed wetland (IVCW), which has been in operation in Wuhan, China since 1998. We used phospholipid fatty acid (PLFA) and amoA gene to analyze the structure and diversity of the microbial community within the IVCW. PLFA results suggested that the amount of bacterial PLFA was significantly higher than that of fungal PLFA, but the total microbial biomass represented by PLFA index was low in the system. Microbial spatial distribution showed significantly higher bacterial (both G(+) and G(-)) and fungal biomass in the surface than in the subsurface layers. The ratios of monounsaturated to branched PLFA demonstrated that an anaerobic layer sandwiched by two aerobic layers existed in the IVCW, consistent with the redox potential results. Analysis of the amoA revealed the presence of Nitrosomonas-like sequences in the surface substrate of the downflow chamber and apparent diversities of ammonia-oxidizing bacteria in the system. These results suggest that microorganisms, despite their relatively low biomass, have inhabited the IVCW, and the results will offer some valuable information on microbe to system designers and managers.
Resumo:
The bioaccumulation of phthalate acid esters (PAEs) from industrial products and their mutagenic action has been suggested to be a potential threat to human health. The effects of the most frequently identified PAE, Di-n-butyl phthalate (DBP), and its biodegradation, were examined by comparison of two small scale plots (SSP) of integrated vertical-flow constructed wetlands. The influent DBP concentration was 9.84 mg l(-1) in the treatment plot and the control plot received no DBP. Soil enzymatic activities of dehydrogenase, catalase, protease, phosphatase, urease, cellulase, beta-glucosidase, were measured in the two SSP after DBP application for 1 month and 2 months, and 1 month after the final application. Both treatment and control had significantly higher enzyme activity in the surface soil than in the subsurface soil (P < 0.001) and greater enzyme activity in the down-flow chamber than in the up-flow chamber (P < 0.05). In the constructed wetlands, DBP enhanced the activities of dehydrogenase, catalase, protease, phosphatase and inhibited the activities of urease, cellulase and beta-glucosidase. However, urease, cellulase, beta-glucosidase activities were restored 1 month following the final DBP addition. Degradation of DBP was greater in the surface soil and was reduced in sterile soil, indicating that this process may be mediated by aerobic microorgansims. DBP degradation fitted a first-order model, and the kinetic equation showed that the rate constant was 0.50 and 0.17 d(-1), the half-life was 1.39 and 4.02 d, and the r(2) was 0.99 and 0.98, in surface and subsurface soil, respectively. These results indicate that constructed wetlands are able to biodegrade organic PA-Es such as DBP. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A twin-shaped constructed wetland (CW) comprising a vertical flow (inflow) chamber with Cyperus alternifolius followed by a reverse-vertical flow (outflow) chamber with Villarsia exaltata was assessed for decontamination of artificial wastewater polluted by heavy metals. After application of Cd, Cu, Pb, Zn over 150 days, together with Al and Mn during the final 114 days, no heavy metals with the exception of Mn could be detected in either the drainage zone at the bottom, shared by both chambers, or in the effluent. The inflow chamber was, therefore, seen to be predominantly responsible for the decontamination process of more toxic metal species with final concentrations far below WHO drinking-water standards. About one-third of the applied Cu and Mn was absorbed, predominantly by lateral roots of C. alternifolius. Lower accumulation levels were observed for Zn (5%), Cd (6%), Al (13%). and Pb (14%). Contents of Cd, Cu, Mn, and Zn in soil were highest in top layer, while Al and Pb were evenly distributed through the whole soil column. Metal species accumulating mainly in the top layer can be removed mechanically. A vertical flow CW with C. alternifolius is an effective tool in phytoremediation for treatment of water polluted with heavy metals. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
A study has been conducted focusing on how the phosphorus renrx)val efficiency of a constructed wetland (CW) can be optimized through the selective enrichment of the substratum. Activated alumina and powdered iron were examined as possible enrichment compounds. Using packed glass column trials it was found that alumina was not suitable for the renx)val of ortho-phosphate from solution, while mixtures of powdered iron and quartz sand proved to be very efficient. The evaluation of iron/sand mixtures in CWs planted with cattails was performed in three stages; first using an indoor lab scale wetland, then an outdoor lab scale wetland, and finally in a small scale pilot project. For the lab scale tests, three basic configurations were evaluated: using the iron/sand as a pre-filter, in the root bed. and as a post filter. Primary lagoon effluent was applied to the test cells to simulate actual CW conditions, and the total phosphorus and iron concentrations of the influent and effluent were nfK)nitored. The pilot scale trials were limited to using only a post filter design, due to in-progress research at the pilot site. The lab scale tests achieved average renrK>val efficiencies greater than 91% for all indoor configurations, and greater than 97% for all outdoor configurations. The pilot scale tests had an average renK)val efficiency of 60%. This relatively low efficiency in the pilot scale can be attributed to the post filters being only one tenth the size of the lab scale test in terms of hydraulic loading (6 cm/day vs. 60 cm/day).
Resumo:
Els Sistemes d'Aiguamolls Construïts (SAC) de Flux Subsuperficial Horitzontal (FSH) és una tecnologia apropiada pel sanejament d'aigües residuals procedents de nuclis de població petits. No obstant els SAC de FSH són considerats una tecnologia natural, l'operació i manteniment d'aquestes depuradores és crucial per a garantir el seu correcte funcionament. Aquestes necessitats d'operació i manteniment varien entre depuradores segons (1) les característiques de la comunitat, (2) la configuració de la depuradora i el disseny del SAC de FSH i (3) les característiques del medi receptor. En aquest sentit, en aquesta tesi es presenta el desenvolupament d'un Sistema d'Ajuda a la Decisió (SAD) per a la definició de protocols d'operació i manteniment per a SAC de FSH tenint en compte els factors que causen variabilitat entre aquest tipus de depuradores (1, 2 i 3).
Resumo:
Two projects of water treatment for public water supply were developed and operated by using combined systems of constructed wetlands. One of the projects was carried out in the town of Analandia, Sao Paulo, Brazil and wetlands with floating aquatic plants associated to the HDS system were used. Nearly 6480 inhabitants were supplied. The other conducted project was an experimental station in partnership with SABESP (Sao Paulo State Sanitation Agency/Brazil), for the pretreatment of 1700 l.s-1 of waters from the Cotia River, which is used for the population's supply after conventional treatment at the Lower Cotia Water Treatment Station. For this pilot project, wetlands with emergents and floating plants associated to the HDS system were used. The proposed objectives were achieved in both projects.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new instrument and method are described that allow the hydraulic conductivities of highly permeable porous materials, such as gravels in constructed wetlands, to be determined in the field. The instrument consists of a Mariotte siphon and a submersible permeameter cell with manometer take-off tubes, to recreate in-situ the constant head permeameter test typically used with excavated samples. It allows permeability to be measured at different depths and positions over the wetland. Repeatability obtained at fixed positions was good (normalised standard deviation of 1–4%), and results obtained for highly homogenous silica sand compared well when the sand was retested in a lab permeameter (0.32 mm.s–1 and 0.31 mm.s–1 respectively). Practical results have a ±30% associated degree of uncertainty because of the mixed effect of natural variation in gravel core profiles, and interstitial clogging disruption during insertion of the tube into the gravel. This error is small, however, compared to the orders of magnitude spatial variations detected. The technique was used to survey the hydraulic conductivity profile of two constructed wetlands in the UK, aged 1 and 15 years respectively. Measured values were high (up to 900 mm.s –1) and varied by three orders of magnitude, reflecting the immaturity of the wetland. Detailed profiling of the younger system suggested the existence of preferential flow paths at a depth of 200 mm, corresponding to the transition between more coarse and less coarse gravel layers (6–12 mm and 3–6 mm respectively), and transverse drift towards the outlet.
Resumo:
Horizontal Subsurface Flow Treatment Wetlands (HSSF TWs) are used by Severn Trent Water as a low-cost tertiary wastewater treatment for rural locations. Experience has shown that clogging is a major operational problem that reduces HSSF TW lifetime. Clogging is caused by an accumulation of secondary wastewater solids from upstream processes and decomposing leaf litter. Clogging occurs as a sludge layer where wastewater is loaded on the surface of the bed at the inlet. Severn Trent systems receive relatively high hydraulic loading rates, which causes overland flow and reduces the ability to mineralise surface sludge accumulations. A novel apparatus and method, the Aston Permeameter, was created to measure hydraulic conductivity in situ. Accuracy is ±30 %, which was considered adequate given that conductivity in clogged systems varies by several orders of magnitude. The Aston Permeameter was used to perform 20 separate tests on 13 different HSSF TWs in the UK and the US. The minimum conductivity measured was 0.03 m/d at Fenny Compton (compared with 5,000 m/d clean conductivity), which was caused by an accumulation of construction fines in one part of the bed. Most systems displayed a 2 to 3 order of magnitude variation in conductivity in each dimension. Statistically significant transverse variations in conductivity were found in 70% of the systems. Clogging at the inlet and outlet was generally highest where flow enters the influent distribution and exits the effluent collection system, respectively. Surface conductivity was lower in systems with dense vegetation because plant canopies reduce surface evapotranspiration and decelerate sludge mineralisation. An equation was derived to describe how the water table profile is influenced by overland flow, spatial variations in conductivity and clogging. The equation is calibrated using a single parameter, the Clog Factor (CF), which represents the equivalent loss of porosity that would reproduce measured conductivity according to the Kozeny-Carman Equation. The CF varies from 0 for ideal conditions to 1 for completely clogged conditions. Minimum CF was 0.54 for a system that had recently been refurbished, which represents the deviation from ideal conditions due to characteristics of non-ideal media such as particle size distribution and morphology. Maximum CF was 0.90 for a 15 year old system that exhibited sludge accumulation and overland flow across the majority of the bed. A Finite Element Model of a 15 m long HSSF TW was used to indicate how hydraulics and hydrodynamics vary as CF increases. It was found that as CF increases from 0.55 to 0.65 the subsurface wetted area increases, which causes mean hydraulic residence time to increase from 0.16 days to 0.18 days. As CF increases from 0.65 to 0.90, the extent of overland flow increases from 1.8 m to 13.1 m, which reduces hydraulic efficiency from 37 % to 12 % and reduces mean residence time to 0.08 days.
Resumo:
Clogging is the main operational problem associated with horizontal subsurface flow constructed wetlands (HSSF CWs). The measurement of saturated hydraulic conductivity has proven to be a suitable technique to assess clogging within HSSF CWs. The vertical and horizontal distribution of hydraulic conductivity was assessed in two full-scale HSSF CWs by using two different in situ permeameter methods (falling head (FH) and constant head (CH) methods). Horizontal hydraulic conductivity profiles showed that both methods are correlated by a power function (FH= CH 0.7821, r 2=0.76) within the recorded range of hydraulic conductivities (0-70 m/day). However, the FH method provided lower values of hydraulic conductivity than the CH method (one to three times lower). Despite discrepancies between the magnitudes of reported readings, the relative distribution of clogging obtained via both methods was similar. Therefore, both methods are useful when exploring the general distribution of clogging and, specially, the assessment of clogged areas originated from preferential flow paths within full-scale HSSF CWs. Discrepancy between methods (either in magnitude and pattern) aroused from the vertical hydraulic conductivity profiles under highly clogged conditions. It is believed this can be attributed to procedural differences between the methods, such as the method of permeameter insertion (twisting versus hammering). Results from both methods suggest that clogging develops along the shortest distance between water input and output. Results also evidence that the design and maintenance of inlet distributors and outlet collectors appear to have a great influence on the pattern of clogging, and hence the asset lifetime of HSSF CWs. © Springer Science+Business Media B.V. 2011.
Resumo:
In this work we demonstrate the potential of permanent magnet based magnetic resonance sensors to monitor and assess the extent of pore clogging in water filtration systems. The performance of the sensor was tested on artificially clogged gravel substrates and on gravel bed samples from constructed wetlands used to treat wastewater. Data indicate that the spin lattice relaxation time is linearly related to the hydraulic conductivity in such systems. In addition, within biologically active filters we demonstrate the ability to determine the relative ratio of biomass to abiotic solids, a measurement which is not possible using alternative techniques. © 2011 The Royal Society of Chemistry.