814 resultados para communication performance assessment
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
This study evaluates the influence of different cartographic representations of in-car navigation systems on visual demand, subjective preference, and navigational error. It takes into account the type and complexity of the representation, maneuvering complexity, road layout, and driver gender. A group of 28 drivers (14 male and 14 female) participated in this experiment which was performed in a low-cost driving simulator. The tests were performed on a limited number of instances for each type of representation, and their purpose was to carry out a preliminary assessment and provide future avenues for further studies. Data collected for the visual demand study were analyzed using non-parametric statistical analyses. Results confirmed previous research that showed that different levels of design complexity significantly influence visual demand. Non-grid-like road networks, for example, influence significantly visual demand and navigational error. An analysis of simple maneuvers on a grid-like road network showed that static and blinking arrows did not present significant differences. From the set of representations analyzed to assess visual demand, both arrows were equally efficient. From a gender perspective, women seem to took at the display more than men, but this factor was not significant. With respect to subjective preferences, drivers prefer representations with mimetic landmarks when they perform straight-ahead tasks. For maneuvering tasks, landmarks in a perspective model created higher visual demands.
Resumo:
Developing a herd localization system capable to operate unattended in communication-challenged areas arises from the necessity of improving current systems in terms of cost, autonomy or any other facilities that a certain target group (or overall users) may demand. A network architecture of herd localization is proposed with its corresponding hardware and a methodology to assess performance in different operating conditions. The system is designed taking into account an eventual environmental impact hence most nodes are simple, cheap and kinetically powered from animal movements-neither batteries nor sophisticated processor chips are needed. Other network elements integrating GPS and batteries operate with selectable duty cycles, thus reducing maintenance duties. Equipment has been tested on Scandinavian reindeer in Lapland and its element modeling is integrated into a simulator to analyze such localization network applicability for different use cases. Performance indicators (detection frequency, localization accuracy and delay) are fitted to assess the overall performance; system relative costs are enclosed also for a range of deployments.
Resumo:
Part 16: Performance Measurement Systems
Resumo:
This paper deals with a hierarchical structure composed by an event-based supervisor in a higher level and two distinct proportional integral (PI) controllers in a lower level. The controllers are applied to a variable speed wind energy conversion system with doubly-fed induction generator, namely, the fuzzy PI control and the fractional-order PI control. The event-based supervisor analyses the operation state of the wind energy conversion system among four possible operational states: park, start-up, generating or brake and sends the operation state to the controllers in the lower level. In start-up state, the controllers only act on electric torque while pitch angle is equal to zero. In generating state, the controllers must act on the pitch angle of the blades in order to maintain the electric power around the nominal value, thus ensuring that the safety conditions required for integration in the electric grid are met. Comparisons between fuzzy PI and fractional-order PI pitch controllers applied to a wind turbine benchmark model are given and simulation results by Matlab/Simulink are shown. From the results regarding the closed loop point of view, fuzzy PI controller allows a smoother response at the expense of larger number of variations of the pitch angle, implying frequent switches between operational states. On the other hand fractional-order PI controller allows an oscillatory response with less control effort, reducing switches between operational states. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Apresentação realizada na Conferência "Changing Public Sevice in a Changing World" realizada em Budapeste a 24 de Abril de 2009
Resumo:
Previous work by our group introduced a novel concept and sensor design for “off-the-person” ECG, for which evidence on how it compares against standard clinical-grade equipment has been largely missing. Our objectives with this work are to characterise the off-the-person approach in light of the current ECG systems landscape, and assess how the signals acquired using this simplified setup compare with clinical-grade recordings. Empirical tests have been performed with real-world data collected from a population of 38 control subjects, to analyze the correlation between both approaches. Results show off-the-person data to be correlated with clinical-grade data, demonstrating the viability of this approach to potentially extend preventive medicine practices by enabling the integration of ECG monitoring into multiple dimensions of people’s everyday lives. © 2015, IUPESM and Springer-Verlag Berlin Heidelberg.
Resumo:
Materials Science Forum Vols. 730-732 (2013) pp 617-622
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
We formulate performance assessment as a problem of causal analysis and outline an approach based on the missing data principle for its solution. It is particularly relevant in the context of so-called league tables for educational, health-care and other public-service institutions. The proposed solution avoids comparisons of institutions that have substantially different clientele (intake).
Resumo:
We formulate performance assessment as a problem of causal analysis and outline an approach based on the missing data principle for its solution. It is particularly relevant in the context of so-called league tables for educational, health-care and other public-service institutions. The proposed solution avoids comparisons of institutions that have substantially different clientele (intake).
Resumo:
OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.
Resumo:
Introduction : Décrire les patients d'une structure gériatrique offrant des hospitalisations de courte durée, dans un contexte ambulatoire, pour des situations gériatriques courantes dans le canton de Genève (Suisse). Mesurer les performances de cette structure en termes de qualité des soins et de coûts. Méthodes : Des données relatives au profil des 100 premiers patients ont été collectées (huit mois), ainsi qu'aux prestations, aux ressources et aux effets (réadmissions, décès, satisfaction, complications) de manière à mesurer différents indicateurs de qualité et de coûts. Les valeurs observées ont été systématiquement comparées aux valeurs attendues, calculées à partir du profil des patients. Résultats : Des critères d'admission ont été fixés pour exclure les situations dans lesquelles d'autres structures offrent des soins mieux adaptés. La spécificité de cette structure intermédiaire a été d'assurer une continuité des soins et d'organiser d'emblée le retour à domicile par des prestations de liaison ambulatoire. La faible occurrence des réadmissions potentiellement évitables, une bonne satisfaction des patients, l'absence de décès prématurés et le faible nombre de complications suggèrent que les soins médicaux et infirmiers ont été délivrés avec une bonne qualité. Le coût s'est révélé nettement plus économique que des séjours hospitaliers après ajustement pour la lourdeur des cas. Conclusion : L'expérience-pilote a démontré la faisabilité et l'utilité d'une unité d'hébergement et d'hospitalisation de court séjour en toute sécurité. Le suivi du patient par le médecin traitant assure une continuité des soins et évite la perte d'information lors des transitions ainsi que les examens non pertinents. INTRODUCTION: To describe patients admitted to a geriatric institution, providing short-term hospitalizations in the context of ambulatory care in the canton of Geneva. To measure the performances of this structure in terms of quality ofcare and costs. METHOD: Data related to the clinical,functioning and participation profiles of the first 100 patients were collected. Data related to effects (readmission, deaths, satisfaction, complications), services and resources were also documented over an 8-month period to measure various quality and costindicators. Observed values were systematically compared to expected values, adjusted for case mix. RESULTS: Explicit criteria were proposed to focus on the suitable patients, excluding situations in which other structures were considered to be more appropriate. The specificity of this intermediate structure was to immediately organize, upon discharge, outpatient services at home. The low rate of potentially avoidable readmissions, the high patient satisfaction scores, the absence of premature death and the low number of iatrogenic complications suggest that medical and nursing care delivered reflect a good quality of services. The cost was significantly lower than expected, after adjusting for case mix. CONCLUSION: The pilot experience showed that a short-stay hospitalization unit was feasible with acceptable security conditions. The attending physician's knowledge of the patients allowed this system tofocus on essential issues without proposing inappropriate services.