955 resultados para common carotid artery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The long-term success of arterial bypass grafting with autologous saphenous veins is limited by neointimal hyperplasia (NIH), which seemingly develops preferentially at sites where hydrodynamic wall shear is low. Placement of a loose-fitting, porous stent around end-to-end, or end-to-side, autologous saphenous vein grafts on the porcine common carotid artery has been found significantly to reduce NIH, but the mechanism is unclear. In a preliminary study, we implanted autologous saphenous vein grafts bilaterally on the common carotid arteries of pigs, placing a stent around one graft and leaving the contralateral graft unstented. At sacrifice 1 month post implantation, the grafts were pressure fixed in situ and resin casts were made. Unstented graft geometry was highly irregular, with non-uniform dilatation, substantial axial lengthening, curvature, kinking, and possible long-pitch helical distortion. In contrast, stented grafts showed no major dilatation, lengthening or curvature, but there was commonly fine corrugation, occasional slight kinking or narrowing of segments, and possible long-pitch helical distortion. Axial growth of grafts against effectively tethered anastomoses could account for these changes. CFD studies are planned, using 3D MR reconstructions, on the effects of graft geometry on the flow. Abnormality of the flow could favour the development of vascular pathology, including NIH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Doppler ultrasound (DUS) examination provides quantitative and qualitative information concerning the blood flow in veins and arteries, enabling their morphological evaluation and the collection of hemodynamic data. Dogs and cats as well as humans may display neurological signs of brain hypoperfusion secondary to common carotid alterations. Hence, DUS examination might aid in the differential diagnosis of neurological disorders of ischemic origin, among other causes. The objective of this study was to register normal values for systolic peak velocity, minimum diastolic velocity, diameter and resistance index of both common carotid arteries of 12 healthy Labrador retriever dogs between 2 and 5 years of age. By gathering these values, we might be able to improve the sensitivity of hemodynamic studies in clinically important brain disorders. Results: There were no statistical differences between the values for the right and left vessels: the systolic peak velocity was 75.8 ± 16 cm/s, minimum diastolic velocity was 12.2 ± 4 cm/s, common carotid diameter was 0.545 ± 0.063 cm, and resistance index was 0.83 ± 0.07. Conclusions: The results of this study might be used to establish normal parameters for Labrador retriever dogs and thus help in the diagnosis of neurological disorders associated with alterations of the carotid arteries. Similar studies must be performed to evaluate the same parameters in other dog breeds of different sizes and skull conformations. © 2013 Svicero et al.; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors describe the use of the Cardica C-Port xA Distal Anastomosis System to perform an automated, high-flow extracranial-intracranial bypass. The C-Port system has been developed and tested in coronary artery bypass surgery for rapid distal coronary artery anastomoses. Air-powered, it performs an automated end-to-side anastomosis within seconds by nearly simultaneously making an arteriotomy and inserting 13 microclips into the graft and recipient vessel. Intracranial use of the device was first simulated in a cadaver prepared for microsurgical anatomical dissection. The authors used this system in a 43-year-old man who sustained a subarachnoid hemorrhage after being assaulted and was found to have a traumatic pseudoaneurysm of the proximal intracranial internal carotid artery. The aneurysm appeared to be enlarging on serial imaging studies and it was anticipated that a bypass would probably be needed to treat the lesion. An end-to-side bypass was performed with the C-Port system using a saphenous vein conduit extending from the common carotid artery to the middle cerebral artery. The bypass was demonstrated to be patent on intraoperative and postoperative arteriography. The patient had a temporary hyperperfusion syndrome and subsequently made a good neurological recovery. The C-Port system facilitates the performance of a high-flow extracranial-intracranial bypass with short periods of temporary arterial occlusion. Because of the size and configuration of the device, its use is not feasible in all anatomical situations that require a high-flow bypass; however it is a useful addition to the armamentarium of the neurovascular surgeon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report the authors' initial experience with carotid artery stent-grafts in a comparatively large patient series for the treatment of acute bleeding and impending rupture or the prevention of distal embolization. MATERIALS AND METHODS: This retrospective study was approved by the institutional review boards and performed according to HIPPA standards. Twenty-five patients were treated with 27 carotid artery stent-grafts (Gore Viabahn, n = 10; Bard Fluency, n = 9; polytetrafluoroethylene-covered Palmaz, n = 5; and Wallgraft, n = 3). Thirteen stent-grafts were placed in patients with carotid blow-out syndrome (including three patients with carotid-airway fistula), 12 in patients with either pseudoaneurysm (n = 9) or true aneurysm (n = 3), and two in patients with intractable high-grade bare stent restenosis. RESULTS: The technical success rate was 100% (27 of 27 cases). No acute procedural transient ischemic attacks or strokes occurred. Procedural dissections occurred in two of the 27 cases (7.4%). Short-term complications occurred in three of the 27 cases (11%) (repeat hemorrhage, n = 2; common carotid artery occlusion, n = 1). The overall patient mortality rate was 36% (nine of 25 patients, all with carotid blow-out syndrome). Six-month follow-up in 15 of the 16 living patients demonstrated widely patent stent-grafts. Two patients with pseudoaneurysm also demonstrated patent stents at 18- and 33-month follow-up. CONCLUSIONS: Stent-grafts may be useful in the treatment of carotid artery bleeding syndrome, aneurysm, and stenosis, with a high procedural success rate in selected cases. The results of mid-term follow-up are encouraging, but results of long-term follow-up must be evaluated in future studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Common carotid artery intima-media thickness (CCIMT) is widely used as a surrogate marker of atherosclerosis, given its predictive association with cardiovascular disease (CVD). The interpretation of CCIMT values has been hampered by the absence of reference values, however. We therefore aimed to establish reference intervals of CCIMT, obtained using the probably most accurate method at present (i.e. echotracking), to help interpretation of these measures. METHODS AND RESULTS We combined CCIMT data obtained by echotracking on 24 871 individuals (53% men; age range 15-101 years) from 24 research centres worldwide. Individuals without CVD, cardiovascular risk factors (CV-RFs), and BP-, lipid-, and/or glucose-lowering medication constituted a healthy sub-population (n = 4234) used to establish sex-specific equations for percentiles of CCIMT across age. With these equations, we generated CCIMT Z-scores in different reference sub-populations, thereby allowing for a standardized comparison between observed and predicted ('normal') values from individuals of the same age and sex. In the sub-population without CVD and treatment (n = 14 609), and in men and women, respectively, CCIMT Z-scores were independently associated with systolic blood pressure [standardized βs 0.19 (95% CI: 0.16-0.22) and 0.18 (0.15-0.21)], smoking [0.25 (0.19-0.31) and 0.11 (0.04-0.18)], diabetes [0.19 (0.05-0.33) and 0.19 (0.02-0.36)], total-to-HDL cholesterol ratio [0.07 (0.04-0.10) and 0.05 (0.02-0.09)], and body mass index [0.14 (0.12-0.17) and 0.07 (0.04-0.10)]. CONCLUSION We estimated age- and sex-specific percentiles of CCIMT in a healthy population and assessed the association of CV-RFs with CCIMT Z-scores, which enables comparison of IMT values for (patient) groups with different cardiovascular risk profiles, helping interpretation of such measures obtained both in research and clinical settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carotid artery disease is the most prevalent etiologic precursor of ischemic stroke, which is a major health hazard and the second most common cause of death in the world. If a patient presents with a symptomatic high-grade (>70%) stenosis in the internal carotid artery, the treatment of choice is carotid endarterectomy. However, the natural course of radiologically equivalent carotid lesions may be clinically quite diverse, and the reason for that is unknown. It would be of utmost importance to develop molecular markers that predict the symptomatic phenotype of an atherosclerotic carotid plaque (CP) and help to differentiate vulnerable lesions from stable ones. The aim of this study was to investigate the morphologic and molecular factors that associate with stroke-prone CPs. In addition to immunohistochemistry, DNA microarrays were utilized to identify molecular markers that would differentiate between symptomatic and asymptomatic CPs. Endothelial adhesion molecule expression (ICAM-1, VCAM-1, P-selectin, and E-selectin) did not differ between symptomatic and asymptomatic patients. Denudation of endothelial cells was associated with symptom-generating carotid lesions, but in studies on the mechanism of decay of endothelial cells, markers of apoptosis (TUNEL, activated caspase 3) were found to be decreased in the endothelium of symptomatic lesions. Furthermore, markers of endothelial apoptosis were directly associated with those of cell proliferation (Ki-67) in all plaques. FasL expression was significantly increased on the endothelium of symptomatic CPs. DNA microarray analysis revealed prominent induction of specific genes in symptomatic CPs, including those subserving iron and heme metabolism, namely HO-1, and hemoglobin scavenger receptor CD163. HO-1 and CD163 proteins were also increased in symptomatic CPs and associated with intraplaque iron deposits, which, however, did not correlate with symptom status itself. ADRP, the gene for adipophilin, was also overexpressed in symptomatic CPs. Adipophilin expression was markedly increased in ulcerated CPs and colocalized with extravasated red blood cells and cholesterol crystals. Taken together, the phenotypic characteristics and the numerous possible molecular mediators of the destabilization of carotid plaques provide potential platforms for future research. The denudation of the endothelial lining observed in symptomatic CPs may lead to direct thromboembolism and maintain harmful oxidative and inflammatory processes, predispose to plaque microhemorrhages, and contribute to lipid accumulation into the plaque, thereby making it vulnerable to rupture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of testosterone on the development of the pressor response to common carotid occlusion was investigated in control and median eminence-lesioned male rats. In control rats (N = 9), gonadectomy performed 21 days before the experiments reduced by 22% (from 51 +/- 2 to 40 +/- 2 mmHg) and treatment with testosterone (300-mu-g for 4 days before the measurements) increased the initial peak pressor response (from 51 +/- 2 to 57 +/- 2 mmHg) which depends on carotid innervation. The maintained response which is of central origin (probably ischemic) was less affected. In nongonadectomized rats (N = 6), lesions of the median eminence (6 days) decreased the initial peak by 19% (from 52 +/- 2 to 42 +/- 3 mmHg) and the maintained response by 56% (from 32 +/- 2 to 14 +/- 1 mmHg). Sham-operated rats served as controls. In gonadectomized animals (N = 6) the lesion reduced only the maintained response (from 23 +/- 2 to 11 +/- 1 mmHg). Testosterone supplementation restored the maintained response but did not alter the initial peak. These results indicate that the pressor response to common carotid occlusion in male rats is modulated by testosterone and that the depression in the maintained response caused by median eminence lesion can be reversed by steroid supplementation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mean arterial pressure and heart rate were determined in conscious, unrestrained groups of 10 male, female and androgenized female Wistar rats 20 s (early pressor response) and 1 min (late sustained response) after bilateral carotid artery occlusion. The early pressor response, which is of carotid reflex origin, was 40% greater in female than in male rats (45 +/- 2 vs 63 +/- 3 mmHg, respectively). The late sustained response, which is of central origin (probably ischemic), did not differ between male and female rats (32 +/- 2 vs 37 +/- 4 mmHg, respectively). The magnitude of the early pressor response of androgenized female tats (50 +/- 2 mmHg) was similar to that of male rats (45 +/- 2 mmHg) but the late sustained response was 19% smaller (26 +/- 2 mmHg). Common carotid occlusion caused increases in heart rate which were greater in female (51 +/- 9 and 34 +/- 9 beats/min in the early pressor response and late sustained response, respectively) than in male rats (31 +/- 5 and 8 +/- 4 beats/min, respectively). In androgenized female rats, heart rate decreased during common carotid occlusion (34 +/- 7 and 35 +/- 8 beats/min after 20 s and 1 min, respectively). These data provide evidence that there are substantial sex-related differences in the cardiovascular responses to common carotid occlusion in conscious rats and indicate that administration of androgens to newborn female rats affects the baroreceptor reflex control of their arterial pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose—To compare potential risk factors, clinical symptoms, diagnostic delay, and 3-month outcome between spontaneous internal carotid artery dissection (sICAD) and spontaneous vertebral artery dissection (sVAD). Methods—We compared patients with sICAD (n=668) and sVAD (n=302) treated in 3 university hospitals. Results—Patients with sICAD were older (46.3±9.6 versus 42.0±10.2 years; P<0.001), more often men (62.7% versus 53.0%; P=0.004), and presented more frequently with tinnitus (10.9% versus 3.4%; P<0.001) and more severe ischemic strokes (median National Institutes of Health Stroke Scale, 10±7.1 versus 5±5.9; P<0.001). Patients with sVAD had more often bilateral dissections (15.2% versus 7.6%; P<0.001) and were more often smokers (36.0% versus 28.7%; P=0.007). Thunderclap headache (9.2% versus 3.6%; P=0.001) and neck pain were more common (65.8% versus 33.5%; P<0.001) in sVAD. Subarachnoid hemorrhage (6.0% versus 0.6%; P<0.001) and ischemic stroke (69.5% versus 52.2%; P<0.001) were more frequent in sVAD. After multivariate analysis, sex difference lost its significance (P=0.21), and all other variables remained significant. Time to diagnosis was similar in sICAD and sVAD and improved between 2001 and 2012 compared with the previous 10-year period (8.0±10.5 days versus 10.7±13.2 days; P=0.004). In sVAD, favorable outcome 3 months after ischemic stroke (modified Rankin Scale, 0–2: 88.8% versus 58.4%; P<0.001), recurrent transient ischemic attack (4.8% versus 1.1%; P=0.001), and recurrent ischemic stroke (2.8% versus 0.7%; P=0.02) within 3 months were more frequent. Conclusions—sICAD and sVAD patients differ in many aspects. Future studies should perform separate analyses of these 2 entities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.