470 resultados para collectors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the seroprevalence of HIV, hepatitis B and C and syphilis and to describe risk behaviors associated to their transmission among recyclable waste collectors. METHODS: A seroepidemiological survey was carried out in the city of Santos, Southeastern Brazil, in 2005. A total of 315 individuals were enrolled in the survey, of which 253 subjects underwent serological testing HIV, hepatitis B and C and syphilis. Statistical analysis consisted of univariate and bivariate analyses (cross-tabulation and odds ratio) and multivariate analysis (by logistic regression), relating HIV infection with established risk behaviors and seropositivity. RESULTS: Overall seroprevalences were: HIV, 8.9%; hepatitis B, 34.4%; hepatitis C, 12.4%; and syphilis, 18.4%. Subjects were characterized by a predominance of males with low educational and economic levels, subjected to parenteral and sexual exposures to HIV and other sexually transmitted infections. Multivariate analysis results indicated that risk factors for both sexually and parenterally related exposure were significantly associated with HIV in this community. CONCLUSIONS: Seroprevalences found in the study were approximately 10 to 12 times higher than the national average. These communities are socially marginalized and generally not recognized by national programs as potentially endangered populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the correlation between sociodemographic factors and working conditions of bus workers in a metropolitan area and violence against them.METHODS This cross-sectional study used a nonprobabilistic sample estimated according to the number of workers employed in bus companies located in three cities in the Belo Horizonte metropolitan region in 2012 (N = 17,470). Face-to-face interviews were conducted using a digital questionnaire. The factors associated with violence were analyzed in two stages using Poisson regression, according to each level. The magnitude of the association was evaluated using prevalence ratios with robust variance and a statistical significance of 5%, and 95% confidence intervals were obtained.RESULTS The study sample comprised 782 drivers and 691 fare collectors; 45.0% participants reported at least one act of violence in the workplace in the last 12 months, with passengers being predominantly responsible. The age of the bus workers was inversely associated with violence. Chronic diseases, sickness absenteeism, and working conditions were also associated with violence.CONCLUSIONS The findings on the correlation between violence and working conditions are essential for implementing prevention strategies by transportation service managers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The collection of recyclable waste materials is a widespread activity among the urban poor. Today, this occupation attracts an increasingly large number of individuals. Despite its economic and environmental importance, this activity is associated with unsafe and unhealthy working conditions. The aim of this study was to investigate the seroepidemiological profile of hepatitis B virus (HBV) infection in a population of recyclable waste collectors in central Brazil. Methods: Recyclable waste collectors from all 15 recycling cooperatives in Goiânia City were invited to participate in the study. The participants (n = 431) were interviewed and screened for hepatitis B surface antigen (HBsAg) and antibodies against HBsAg (anti-HBs) and hepatitis B core antigen (anti-HBc) by enzyme-linked immunosorbent assay (ELISA). HBsAg- and anti-HBc-positive samples were tested for HBV DNA and genotyped. Results: The overall prevalence of HBV infection (HBsAg- and/or anti-HBc-positive) was 12.8%. An age over 40 years and illicit drug use were associated with HBV infection. HBV DNA was detected in 2/3 HBsAg-positive samples and in 1/52 anti-HBc-positive/HBsAg-negative samples (an occult HBV infection rate of 1.9%), in which the genotypes/subgenotypes A/A1, D/D3 and F/F2 were identified. Only 12.3% of the recyclable waste collectors had serological evidence of previous HBV vaccination. Conclusions: These findings highlight the vulnerability of recyclable waste collectors to HBV infection and reinforce the importance of public health policies that address the health and safety of this socially vulnerable population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of hepatitis C virus (HCV) in a population of recyclable waste collectors (n = 431) was assessed using a cross-sectional survey in all 15 cooperatives in the city of Goiânia, Central-West Brazil. The HCV prevalence was 1.6% (95% confidence interval: 0.6-3.6) and a history of sexually transmitted infections was independently associated with this infection. HCV RNA (corresponding to genotype 1; subtypes 1a and 1b) was detected in five/seven anti-HCV-positive samples. Although the study population reported a high rate (47.3%) of sharps and needle accidents, HCV infection was not more frequent in recyclable waste collectors than in the general Brazilian population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Inhalation of bioaerosols has been hypothesised to cause "toxic pneumonitis" that should increase lung epithelial permeability at the bronchioloalveolar level. Serum Clara cell protein (CC16) and serum surfactant protein B (SPB) have been proposed as sensitive markers of lung epithelial injury. This study was aimed at looking for increased lung epithelial permeability by determining CC16 and SPB in workers exposed to bioaerosols from wastewater or garbage. METHODS: Subjects (778 wastewater, garbage and control workers; participation 61%) underwent a medical examination, lung function tests [American Thoracic Society (ATS) criteria], and determination of CC16 and SPB. Symptoms of endotoxin exposure and several potential confounders (age, gender, smoking, kidney function, obesity) were looked for. Results were examined with multiple linear or logistic regression. RESULTS: Exposure to bioaerosols increased CC16 concentration in the wastewater workers. No effect of exposure on SPB was found. No clue to work-related respiratory diseases was found. CONCLUSIONS: The increase in CC16 in serum supports the hypothesis that bioaerosols cause subclinical "toxic pneumonitis", even at low exposure. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El projecte "Gestor de col·lectors virtuals de dades" explica la implantació d'eines de programari lliure a l'empresa i la implementació d'un projecte amb aquestes eines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are two fundamental puzzles about trade credit: why does it appearto be so expensive,and why do input suppliers engage in the business oflending money? This paper addresses and answers both questions analysingthe interaction between the financial and the industrial aspects of thesupplier-customer relationship. It examines how, in a context of limitedenforceability of contracts, suppliers may have a comparative advantageover banks in lending to their customers because they hold the extrathreat of stopping the supply of intermediate goods. Suppliers may alsoact as lenders of last resort, providing insurance against liquidityshocks that may endanger the survival of their customers. The relativelyhigh implicit interest rates of trade credit result from the existenceof default and insurance premia. The implications of the model areexamined empirically using parametric and nonparametric techniques on apanel of UK firms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endotoxin causes an inflammation at the bronchial and alveolar level. The inflammation-induced increase in permeability of the bronchoalveolar epithelial barrier is supposed to cause a leakage of pneumoproteins. Therefore, their concentrations are expected to increase in the bloodstream.This study aimed at examining the association between occupational exposure to endotoxin and a serum pneumoprotein, surfactant protein A, to look for nonoccupational factors capable of confounding this association, and examine the relation between surfactant protein A and spirometry. There were 369 control subjects, 325 wastewater workers, and 84 garbage collectors in the study. Exposure to endotoxin was assessed through personal sampling and the Limulus amebocytes lysate assay. Surfactant protein A was determined by an in house sandwich enzyme-linked immunosorbent assay (ELISA) in 697 subjects. Clinical and smoking history were ascertained and spirometry carried out according to American Thoracic Society criteria. Multiple linear regression was used for statistical analysis. Exposure was fairly high during some tasks in wastewater workers but did not influence surfactant protein A. Surfactant protein A was lower in asthmatics. Interindividual variability was large. No correlation with spirometry was found. Endotoxin has no effect on surfactant protein A at these endotoxin levels and serum surfactant protein A does not correlate with spirometry. The decreased surfactant protein A secretion in asthmatics requires further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper examines building integrated solar collectors with absorbers of polymeric materials. Efficiency measurements of façade-integrated collectors with non-selective black and spectrally selective coloured absorbers are carried out. The performance of the polymeric absorber was compared with solar glass and polycarbonate twin-wall sheets as collector cover. Simulations demonstrate a high solar fraction for a solar combisystem with façade collectors for a well-insulated house in a Nordic climate. Two examples of house concepts with façade collectors are presented which address a new type of customer than the solar enthusiasts with special interest in renewable energy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Sweden solar irradiation and space heating loads are unevenly distributed over the year. Domestic hot water loads may be nearly constant. Test results on solar collector performance are often reported as yearly output of a certain collector at fixed temperatures, e g 25, 50 and 75 C. These data are not suitable for dimensioning of solar systems, because the actual performance of the collector depends heavily on solar fraction and load distribution over the year.At higher latitudes it is difficult to attain high solar fractions for buildings, due to overheating in summer and small marginal output for added collector area. Solar collectors with internal reflectors offer possibilities to evade overheating problems and deliver more energy at seasons when the load is higher. There are methods for estimating the yearly angular irradiation distribution, but there is a lack of methods for describing the load and the storage in such a way as to enable optical design of season and load adapted collectors.This report describes two methods for estimation of solar system performance with relevance for season and load adaption. Results regarding attainable solar fractions as a function of collector features, load profiles, load levels and storage characteristics are reported. The first method uses monthly collector output data at fixed temperatures from the simulation program MINSUN for estimating solar fractions for different load profiles and load levels. The load level is defined as estimated yearly collector output at constant collector temperature divided be yearly load. This table may examplify the results:CollectorLoadLoadSolar Improvementtypeprofile levelfractionover flat plateFlat plateDHW 75 %59 %Load adaptedDHW 75 %66 %12 %Flat plateSpace heating 50 %22 %Load adaptedSpace heating 50 %28 %29 %The second method utilises simulations with one-hour timesteps for collectors connected to a simplified storage and a variable load. Collector output, optical and thermal losses, heat overproduction, load level and storage temperature are presented as functions of solar incidence angles. These data are suitable for optical design of load adapted solar collectors. Results for a Stockholm location indicate that a solar combisystem with a solar fraction around 30 % should have collectors that reduce heat production at solar heights above 30 degrees and have optimum efficiency for solar heights between 8 and 30 degrees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of measurements on the performance of solar cell string modules with low-concentrating CPC reflectors with a concentration factor C ˜ 4X have been carried out. To minimise the reduction in efficiency due to high cell temperatures, the modules were cooled. Four different way of cooling were tested:1) The thermal mass of the module was increased, 2) passive air cooling was used by introducing a small air gap between the module and the reflector, 3) the PV cells were cooled by a large cooling fin, 4) the module was actively cooled by circulating cold water on the back. The best performance was given with the actively cooled PV module which gave 2,2 times the output from a reference module while for the output from the module with a cooling fin the value was 1,8.Active cooling is also interesting due to the possibility of co-generation of thermal and electrical energy which is discussed in the paper. Simulations, based on climate data from Stockholm, latitude 59.4°N, show that there are good prospects for producing useful temperatures of the cooling fluid with only a slightly reduced performance of the electrical fraction of the PV thermal hybrid system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sealed gas filled flat plate solar collectors will have stresses in the material since volume and pressure varies in the gas when the temperature changes. Several geometries were analyzed and it could be seen that it is possible reducing the stresses and improve the safety factor of the weakest point in the construction by using larger area and/or reducing the distance between glass and absorber and/or change width and height relationship so the tubes are getting longer. Further it could be shown that the safety factor won't always get improved with reinforcements. It is so because when an already strong part of the collector gets reinforced it will expose weaker parts for higher stresses. The finite element method was used for finding out the stresses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With a suitable gas filling used between cover glass and absorber in a flat plate solar collector, it is possible achieving better thermal performance at the same time as the distance betweenabsorber and glass can be reduced. Though, even if there is no vacuum inside the box, there will be potential risks for exhaustion due to stresses depending on the gas volume varies as the temperature varies. This study found out that it is possible build such a collector with less material in the absorber and the tubes and still getting better performance, without risks for exhaustion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dagens kombisolvärmesystem för enfamiljshus har i storleksordningen 10 m2 solfångare och kan täcka i runda tal 10 ? 30 % av det årliga värmebehovet. Ökar man solfångarytan för att öka solvärmetäckningsgraden uppstår det vanligtvis en överproduktion av värme sommartid viket kan orsaka problem i form av termisk utmattning av material, att material förstörs eller att säkerhetsventiler utlöses med driftsstopp som följd. Vidare förkortas glykolens livslängd radikalt och detta kan ge följdskador såsom korrosion, beläggningar i rören och t o m igensättning av systemet. Ett sätt att undvika problemen med överhettning i solvärmesystem med hög täckningsgrad är att använda lastanpassade solfångare. Med detta menas solfångare som har en verkningsgrad som är beroende av solhöjden och varierar över året. Verkningsgraden är hög när värmelasten är hög (vanligtvis sen höst, vinter och tidig vår) medan verkningsgraden är låg då värmelasten är låg (vanligtvis sen vår, sommar och tidig höst). I denna rapport visas att det är möjligt att bygga lastanpassade solfångarsystem med hög täckningsgrad för enfamiljshus med solfångarytor som täcker hela villatak (>= 40 m2), utan att den termiska påfrestningen på systemet blir större än för vanliga solvärmesystem med 10 m2 plana solfångare. Detta kan göras med samma systemkomponenter som finns i system med plana solfångare. De lastanpassade solfångarna levererar ungefär samma energimängd per m2 som plana solfångare, men de bör kunna bli billigare, på grund av lägre materialkostnad. Det finns även en potential att konstruera lastanpassade solvärmesystem med begränsad stagnationstemperatur, vilket kan möjliggöra användandet av billigare material. En och samma solfångartyp är lämplig för såväl stora som små system och för olika takvinklar. I rapporten redovisas optimerade solfångargeometrier för lastanpassade solvärmesystem, geometrier och optiska egenskaper för praktiskt möjliga solfångare samt beräkningar av förväntat årsutbyte, stagnationstemperaturer, stagnationstider och kostnader. Testresultat för två prototyper av lastanpassade solfångare presenteras. Optimeringsalgoritmer för design av optiken för lastanpassade solfångare i system samt ett ray-tracingverktyg och snabba men ändå tillräckligt noggranna simuleringsverktyg har utvecklats.