921 resultados para co-incineration of waste


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmentally harmful consequences of fossil fuel utilisation andthe landfilling of wastes have increased the interest among the energy producers to consider the use of alternative fuels like wood fuels and Refuse-Derived Fuels, RDFs. The fluidised bed technology that allows the flexible use of a variety of different fuels is commonly used at small- and medium-sized power plants ofmunicipalities and industry in Finland. Since there is only one mass-burn plantcurrently in operation in the country and no intention to build new ones, the co-firing of pre-processed wastes in fluidised bed boilers has become the most generally applied waste-to-energy concept in Finland. The recently validated EU Directive on Incineration of Wastes aims to mitigate environmentally harmful pollutants of waste incineration and co-incineration of wastes with conventional fuels. Apart from gaseous flue gas pollutants and dust, the emissions of toxic tracemetals are limited. The implementation of the Directive's restrictions in the Finnish legislation is assumed to limit the co-firing of waste fuels, due to the insufficient reduction of the regulated air pollutants in the existing flue gas cleaning devices. Trace metals emission formation and reduction in the ESP, the condensing wet scrubber, the fabric filter, and the humidification reactor were studied, experimentally, in full- and pilot-scale combustors utilising the bubbling fluidised bed technology, and, theoretically, by means of reactor model calculations. The core of the model is a thermodynamic equilibrium analysis. The experiments were carried out with wood chips, sawdust, and peat, and their refuse-derived fuel, RDF, blends. In all, ten different fuels or fuel blends were tested. Relatively high concentrations of trace metals in RDFs compared to the concentrations of these metals in wood fuels increased the trace metal concentrations in the flue gas after the boiler ten- to hundred-folds, when RDF was co-fired with sawdust in a full-scale BFB boiler. In the case of peat, lesser increase in trace metal concentrations was observed, due to the higher initial trace metal concentrations of peat compared to sawdust. Despite the high removal rate of most of the trace metals in the ESP, the Directive emission limits for trace metals were exceeded in each of the RDF co-firing tests. The dominat trace metals in fluegas after the ESP were Cu, Pb and Mn. In the condensing wet scrubber, the flue gas trace metal emissions were reduced below the Directive emission limits, whenRDF pellet was used as a co-firing fuel together with sawdust and peat. High chlorine content of the RDFs enhanced the mercuric chloride formation and hence the mercury removal in the ESP and scrubber. Mercury emissions were lower than theDirective emission limit for total Hg, 0.05 mg/Nm3, in all full-scale co-firingtests already in the flue gas after the ESP. The pilot-scale experiments with aBFB combustor equipped with a fabric filter revealed that the fabric filter alone is able to reduce the trace metal concentrations, including mercury, in the flue gas during the RDF co-firing approximately to the same level as they are during the wood chip firing. Lower trace metal emissions than the Directive limits were easily reached even with a 40% thermal share of RDF co-firing with sawdust.Enrichment of trace metals in the submicron fly ash particle fraction because of RDF co-firing was not observed in the test runs where sawdust was used as the main fuel. The combustion of RDF pellets with peat caused an enrichment of As, Cd, Co, Pb, Sb, and V in the submicron particle mode. Accumulation and release oftrace metals in the bed material was examined by means of a bed material analysis, mass balance calculations and a reactor model. Lead, zinc and copper were found to have a tendency to be accumulated in the bed material but also to have a tendency to be released from the bed material into the combustion gases, if the combustion conditions were changed. The concentration of the trace metal in the combustion gases of the bubbling fluidised bed boiler was found to be a summary of trace metal fluxes from three main sources. They were (1) the trace metal flux from the burning fuel particle (2) the trace metal flux from the ash in the bed, and (3) the trace metal flux from the active alkali metal layer on the sand (and ash) particles in the bed. The amount of chlorine in the system, the combustion temperature, the fuel ash composition and the saturation state of the bed material in regard to trace metals were discovered to be key factors affecting therelease process. During the co-firing of waste fuels with variable amounts of e.g. ash and chlorine, it is extremely important to consider the possible ongoingaccumulation and/or release of the trace metals in the bed, when determining the flue gas trace metal emissions. If the state of the combustion process in regard to trace metals accumulation and/or release in the bed material is not known,it may happen that emissions from the bed material rather than the combustion of the fuel in question are measured and reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Virtain kaupungissa sijaitseva vuodesta –79 toiminut lämpövoimala on pääasiassa kotimaisia polttoaineita käyttävä kaukolämpöä tuottava voimalaitos. Jätemurskeen (REF) osuus on tällä hetkellä noin 10 % laitoksen lämmöntuotosta. REF valmistetaan paikallisesti ja sen tuotantoa on tarkoitus lisätä lähivuosina voimakkaasti. EU:n uusi todennäköisesti loppuvuodesta-2000 hyväksyttävä jätteenpolttoa koskeva direktiivi asettaa jätteen rinnakkaispolttolaitoksille tiukat päästörajat ja mittausvelvoitteet. Tämä lisää tuntuvasti kustannuksia Virtain laitoksen kaltaisissa pienissä kierrätyspolttoainetta hyödyntävissä laitoksissa. Työssä selvitettiin jätteenpolttodirektiivistä aiheutuvat savukaasujen mittaamisen kokonaiskustannukset Virroilla. Taloudellisimman mittausjärjestelmän vuo-tuisiksi kokonaiskustannuksiksi saatiin 180 000 mk jakautuen seuraavasti: Jatkuvatoimiset mittauslaitteet käyttökuluineen 90 000 mk, jaksottaiset HF, HCl ja SO2 -mittaukset 20 000 mk, raskasmetallien, dioksiinien ja furaanien määräaikainen mittaaminen 40 000 mk ja vertailumittaukset 30 000 mk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena oli kartoittaa jätteenpolttolaitosten nykytilannetta ja tulevaisuuden näkymiä aina vuoteen 2015 asti viidessä Euroopan maassa (Saksa, Ranska, Iso-Britannia, Espanja ja Italia). Jätteenpoltolla ja jätteenpolttolaitoksella käsitettiin tässä tutkimuksessa kaikki jätteenpolttodirektiivin 2000/76/EY alaisuuteen kuuluva jätteen polttaminen. Tutkimus oli luonteeltaan kvalitatiivista eli laadullista. Tutkimusmenetelmänä käytettiin asiantuntijahaastatteluita. Asiantuntijat olivat useista Euroopan maista ja edustivat eri organisaatioita. Haastattelut toteutettiin puhelimen ja sähköpostin välityksellä. Tutkimuksen johtopäätöksenä oli, että jätteenpoltto on kasvava ala kaikissa tutkimuksen kohdemaissa ja että uusia jätteenpolttolaitoksia tullaan rakentamaan kaikkiin viiteen maahan. Eräänä tärkeimmistä syistä oli ns. kaatopaikkadirektiivin 1999/31/EY asettamat rajoitukset kaatopaikoille vietävän jätteen määrälle. Jätteiden rinnakkaispoltto ja jätteistä jalostettujen polttoaineiden käyttö tunnistettiin tulevaisuuden kannalta merkittäviksi trendeiksi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research of advanced technologies for energy generation contemplates a series of alternatives that are introduced both in the investigation of new energy sources and in the improvement and/or development of new components and systems. Even though significant reductions are observed in the amount of emissions, the proposed alternatives require the use of exhaust gases cleaning systems. The results of environmental analyses based on two configurations proposed for urban waste incineration are presented in this paper; the annexation of integer (Boolean) variables to the environomic model makes it possible to define the best gas cleaning routes based on exergetic cost minimisation criteria. In this first part, the results for steam cogeneration system analysis associated with the incineration of municipal solid wastes (MSW) is presented. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first paper of this paper (Part I), conditions were presented for the gas cleaning technological route for environomic optimisation of a cogeneration system based in a thermal cycle with municipal solid waste incineration. In this second part, an environomic analysis is presented of a cogeneration system comprising a combined cycle composed of a gas cycle burning natural gas with a heat recovery steam generator with no supplementary burning and a steam cycle burning municipal solid wastes (MSW) to which will be added a pure back pressure steam turbine (another one) of pure condensation. This analysis aims to select, concerning some scenarios, the best atmospheric pollutant emission control routes (rc) according to the investment cost minimisation, operation and social damage criteria. In this study, a comparison is also performed with the results obtained in the Case Study presented in Part I. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy from waste (E/W) technologies in the form o f biogas plants, CHP plants and other municipal solid waste (MSW) conversion technologies, have been gaining steady ground in the provision o f energy throughout Europe and the UK. Urban Waste Water Treatment Plants (UWWTP) are utilising much o f the same biochemical processes common to these E/W plants. Previous studies on Centralised Anaerobic Digestion (CAD) within Ireland found that the legislative and economic conditions were not conducive to such an operation on the grounds o f low energy price for electric and heat energy, and due to the restrictive nature o f the allowable feedstocks. Recent changes to the Irish REFIT tariff on energy produced from Anaerobic digestion; alterations to the regulation o f the allowable use o f animal by products(ABP); the recent enactment o f the Renewable Energy D irective (09/28/EC) and a subsequent review o f the draft Biowaste Directive (2001) required that the issue o f decentralised energy production in Ireland be reassessed. In this instance the feasibility study is based on a extant rural community, centred around the village o f Woodford Co Galway. The review found that the prevailing conditions were now such that it was technically and economically feasible for this biochemical process to provide energy and waste treatment facilities at the above location. The review also outlines the last item which is preventing this process from becoming achievable, specifically the lack o f a digestate regulation on land spreading which deals specifically with biowaste. The study finds that the implementation o f the draft EU biowaste regulations, with amendments for Cr and Hg levels to match the proposed Irish regulation for compost, would ensure that Ireland has some o f the most restrictive regulations in Europe for this application. The delay in completing this piece o f legislation is preventing national energy and waste issues from being resolved in a planned and stepwise fashion. A proposed lay out for the new Integrated Waste from Energy Plant (IW/EP) is presented. Budget economic projections and alternative revenue streams are outlined. Finally a review o f the national policies regarding the Rural Development Plan (RDP), the Rural Planning Guidelines (RPG) and the National Renewable Energy Action Plan (NREAP) are examined against the relevant EU directives.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dioxins and furans, PCDD/Fs, are highly toxic substances formed in post combustion zones in furnaces. PCDD/F emissions are regulated by a waste incineration directive which relates also to co-incineration plants. Several observations of dioxin and furan enhancements in wet scrub- bers have been reported previously. This is thought to be due to the so-called "memory effect" which occurs when dioxins and furans absorb into plastic material in scrubbers and desorb when ambient circumstances alter significantly. At the co-incineration plant involved, dioxins and furans are controlled with a wet scrubber, the tower packing of which is made of plastic in which activated carbon particles are dispersed. This should avoid the memory effect and act as a dioxin and furan sink since dioxins and furans are absorbed irreversibly into the packing ma- terial. In this case, the tower packing in the scrubber is covered with a white layer that has been found to be mainly aluminium. The aim of this thesis was to determine the aluminium balance and the dioxin and furan behaviour in the scrubber and, thus, the impacts that the foul- ing has on dioxin and furan removal. The source of aluminium, reasons for fouling and further actions to minimize its impacts on dioxin and furan removal were also to be discovered. Measurements in various media around the scrubber and in fuels were made and a profile analysis of PCDD/F and mass balance calculations were carried out. PCDD/F content de- creased in the scrubber. The reduced PCDD/F was not discharged into scrubbing water. The removal mechanism seems to work in spite of the fouling, at least with low PCDD/F loads. Most of the PCDD/F in excess water originates from the Kymijoki River which is used as feeding water in the scrubber. Fouling turned out to consist mainly of aluminium hydroxides. Sludge combusted in the furnace was found to be a significant source of aluminium. Ways to minimize the fouling would be adjustment of pH to a proper lever, installation of a mechanical filter to catch the loose material from the scrubbing water and affecting the aluminium content of the sludge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first paper of this paper (Part I), conditions were presented for the gas cleaning technological route for environomic optimisation of a cogeneration system based in a thermal cycle with municipal solid waste incineration. In this second part, an environomic analysis is presented of a cogeneration system comprising a combined cycle composed of a gas cycle burning natural gas with a heat recovery steam generator with no supplementary burning and a steam cycle burning municipal solid wastes (MSW) to which will be added a pure back pressure steam turbine (another one) of pure condensation. This analysis aims to select, concerning some scenarios, the best atmospheric pollutant emission control routes (rc) according to the investment cost minimisation, operation and social damage criteria. In this study, a comparison is also performed with the results obtained in the Case Study presented in Part I. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research of advanced technologies for energy generation contemplates a series of alternatives that are introduced both in the investigation of new energy sources and in the improvement and/or development of new components and systems. Even though significant reductions are observed in the amount of emissions, the proposed alternatives require the use of exhaust gases cleaning systems. The results of environmental analyses based on two configurations proposed for urban waste incineration are presented in this paper; the annexation of integer (Boolean) variables to the environomic model makes it possible to define the best gas cleaning routes based on exergetic cost minimisation criteria. In this first part, the results for steam cogeneration system analysis associated with the incineration of municipal solid wastes (MSW) is presented. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot-scale study was completed to determine the feasibility of high-solids anaerobic digestion (HSAD) of a mixture of food and landscape wastes at a university in central Pennsylvania (USA). HSAD was stable at low loadings (2g COD/L-day), but developed inhibitory ammonia concentrations at high loadings (15g COD/L-day). At low loadings, methane yields were 232L CH4/kg COD fed and 229L CH4/kg VS fed, and at high loadings yields were 211L CH4/kg COD fed and 272L CH4/kg VS fed. Based on characterization and biodegradability studies, food waste appears to be a good candidate for HSAD at low organic loading rates; however, the development of ammonia inhibition at high loading rates suggests that the C:N ratio is too low for use as a single substrate. The relatively low biodegradability of landscape waste as reported herein made it an unsuitable substrate to increase the C:N ratio. Codigestion of food waste with a substrate high in bioavailable carbon is recommended to increase the C:N ratio sufficiently to allow HSAD at loading rates of 15g COD/L-day. Copyright 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - Occupational exposures are characterized by being complex and associated to co-exposure to several contaminants by different exposure routes. Even if exposure occurs to only a chemical agent, it can have different exposure routes and can result in different health effects. The waste management setting is recognized by the presence of several chemical and biologic agents in the workplaces. Recently, it was reported occupational exposure to Aflatoxin B1 (AFB1) in one Portuguese waste management industry. However, data regarding to fungal burden showed that exposure to other mycotoxins should be expected. Aim of the study - The aim of the present work was to know if workers from this waste management industry were exposed to other mycotoxins besides AFB1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article is intended to evaluate the density and the mechanical, acoustic and thermal properties of compression moulded plates composed of granulate from electrical cables wastes. Those cable wastes are the insulation part from the electric cables, and are composed of PVC, PE, EMP and PEX rubber. After these materiais lose their initial properties and cease to be useful as insulation material, due to safety requirements, it is possible to reuse them into new applications like industrial or playground floorings, as sound insulation material to be applied in walls or floors, or to dampen vibrations from equipments. Recovering electric cable waste has been a major concern to the European Commission due to its leveis of toxicity when incineration and land fill ing is the solution to dispose this material. Such as the European Commission's study for DG Xl[1] suggested that recycling may be the most favourable future waste management option.