981 resultados para clean-up


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR) biosensor screening assay was developed and validated to detect 11 benzimidazole carbamate (BZT) veterinary drug residues in milk. The polyclonal antibody used was raised in sheep against a methyl 5(6)-[(carboxypentyl)-thio]-2-benzimidazole carbamate protein conjugate. A sample preparation procedure was developed using a modified QuEChERS method. BZT residues were extracted from milk using liquid extraction/partition with a dispersive solid phase extraction clean-up step. The assay was validated in accordance with the performance criteria described in 2002/657/EC. The limit of detection of the assay was calculated from the analysis of 20 known negative milk samples to be 2.7 mu g kg(-1). The detection capability (CC beta) of the assay was determined to be 5 mu g kg(-1) for 11 benzimidazole residues and the mean recovery of analytes was in the range 81-116%. A comparison was made between the SPR-biosensor and UPLC-MS/MS analyses of milk samples (n = 26) taken from cows treated different benzimidazole products, demonstrating the SPR-biosensor assay to be fit for purpose. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 mug kg (-1) in liver and 5, 15 and 50 mug kg (-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 mug kg (-1), respectively. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ractopamine (RCT) is a phenethanolamine member of the family of beta-adrenergic agonists (beta-agonists), This class of compounds have become notable for their properties of enhancing the growth rates of farm animal species but are not licensed for use in Europe. An ELISA procedure employing a polyclonal antibody raised in a goat was developed to detect RCT residues in bovine urine samples, The assay had a high sensitivity (calibration curve mid-point of 22 pg per well), allowing the analysis of urine samples without the need for sample clean-up. In addition, an LC-MS-MS confirmatory procedure was developed which was able to act as a confirmatory procedure for the ELISA results. Four calves were orally treated with RCT (0.1 mg kg(-1) body mass for 17 d) and urine samples collected were assayed by both analytical procedures. It was observed that RCT residues were excreted mainly in the form of glucuronides and deconjugation could be achieved using two different sources of the enzyme beta-glucuronidase (Helix pomatia and Escherichia coli), High concentrations of RCT residues were found throughout the medication period (44-473 ng ml(-1); LC-MS-MS data) and remained present for several days following removal of the drug from the diet, RCT residues were no longer detectable 2 weeks after withdrawal, Good agreement (r(2) = 0.73) was achieved between the ELISA and LC-MS-MS results, especially when sample deconjugation was applied to the urine samples for both sets of analyses, The results show that an effective screening and confirmatory system was devised to detect RCT residues in urine samples taken during treatment and close to withdrawal, However, alternative matrices may have to be selected to allow the illegal use of the substance to be detected following prolonged withdrawal times.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A liquid chromatography-thermospray mass spectrometric assay was developed and validated to confirm the presence of illegal residues of the synthetic androgenic growth promoter, trenbolone acetate, in cattle. The assay was specific for 17alpha-trenbolone, the major bovine metabolite of trenbolone acetate. Methods were developed for the determination of 17alpha-trenbolone in both bile and faeces, the most appropriate matrices for the control of trenbolone acetate abuse. The clean-up.procedure developed relied on enzymatic hydrolysis, followed by sequential liquid-liquid and liquid-solid extraction. The extracts were then subjected to immunoaffinity chromatography. 17alpha-Trenbolone was detected by selected ion monitoring at m/z 271 using positive ion thermospray ionisation. The limit of detection was approximately 0.5 ng/g in faeces and 0.5 ng/ml in bile.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Endocrine disruptors (EDs) are compounds known to interfere with the endocrine system by disturbing the action or pathways of natural hormones which may lead to infertility or cancer.Our diet is considered to be one of the main exposure routes to EDs. Since milk and dairy products are major components of our diet they should be monitored for ED contamination. Most assays developed to date utilise targeted, chromatography based methods which lack information on the biological activity and mixture effects of the monitored compounds.A biological reporter gene assay (RGA) was developed to assess the total estrogen hormonal load in milk. It has been validated according to EU decision 2002/657/EC. Analytes were extracted by liquid-liquid extraction with acetonitrile followed by clean up on a HLB column which yielded good recovery and small matrix effects. The method has been shown to be estrogen specific, repeatable and reproducible, with covariance values below 20%. In conclusion, this method enables the detection of low levels of estrogen hormonal activity in milk with a detection capability of 36pgg EEQ and has been successfully applied in testing a range of milk samples. © 2014 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A series of imprinted polymers targeting nucleoside metabolites, prepared using a template analogue approach, are presented. These were prepared following selection of the optimum functional monomer by solution association studies using 1H-NMR titrations whereby methacrylic acid was shown to be the strongest receptor with and affinity constant of 621 ± 51 L mol-1 vs. 110 ± 16 L mol-1 for acrylamide. The best performing polymers were prepared using methanol as porogenic co-solvent and although average binding site affinities were marginally reduced, 2.3×104 L mol-1 vs. 2.7×104 L mol-1 measured for a polymer prepared in acetonitrile, these polymers contained the highest number of binding sites, 5.27 μmol g-1¬¬ vs. 1.64 μmol g-1, while they also exhibited enhanced selectivity for methylated guanosine derivatives. When applied as sorbents in the extraction of nucleoside derivative cancer biomarkers from synthetic urine samples, significant sample clean-up and recoveries of up to 90% for 7-methylguanosine were achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Integrating analysis and design models is a complex task due to differences between the models and the architectures of the toolsets used to create them. This complexity is increased with the use of many different tools for specific tasks using an analysis process. In this work various design and analysis models are linked throughout the design lifecycle, allowing them to be moved between packages in a way not currently available. Three technologies named Cellular Modeling, Virtual Topology and Equivalencing are combined to demonstrate how different finite element meshes generated on abstract analysis geometries can be linked to their original geometry. Cellular models allow interfaces between adjacent cells to be extracted and exploited to transfer analysis attributes such as mesh associativity or boundary conditions between equivalent model representations. Virtual Topology descriptions used for geometry clean-up operations are explicitly stored so they can be reused by downstream applications. Establishing the equivalence relationships between models enables analysts to utilize multiple packages for specialist tasks without worrying about compatibility issues or substantial rework.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Subsistence farmers are exposed to a range of mycotoxins. This study applied novel urinary multi-mycotoxin LC-MS/MS methods to determine multiple exposure biomarkers in the high oesophageal cancer region, Transkei, South Africa. Fifty-three female participants donated part of their maize-based evening meal and first void morning urine, which was analysed both with sample clean-up (single and multi-biomarker) and by a 'dilute-and-shoot' multi-biomarker method. Results were corrected for recovery with LOD for not detected. A single biomarker method detected fumonisin B1 (FB1) (87% incidence; mean±standard deviation 0.342±0.466 ng/mg creatinine) and deoxynivalenol (100%; mean 20.4±49.4 ng/mg creatinine) after hydrolysis with β-glucuronidase. The multi-biomarker 'dilute-and-shoot' method indicated deoxynivalenol-15-glucuronide was predominantly present. A multi-biomarker method with β-glucuronidase and immunoaffinity clean-up determined zearalenone (100%; 0.529±1.60 ng/mg creatinine), FB1 (96%; 1.52±2.17 ng/mg creatinine), α-zearalenol (92%; 0.614±1.91 ng/mg creatinine), deoxynivalenol (87%; 11.3±27.1 ng/mg creatinine), β-zearalenol (75%; 0.702±2.95 ng/mg creatinine) and ochratoxin A (98%; 0.041±0.086 ng/mg creatinine). These demonstrate the value of multi-biomarker methods in measuring exposures in populations exposed to multiple mycotoxins. This is the first finding of urinary deoxynivalenol, zearalenone, their conjugates, ochratoxin A and zearalenols in Transkei.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The performances of four LC-MS/MS methodologies for determination of up to eight mycotoxin biomarkers in human urines were compared by involving three laboratories that analysed common urine samples spiked at two levels of each biomarker. Each laboratory received a calibration solution, spiked urines and the corresponding unspiked urine. The two spiking levels for each biomarker were chosen by considering the levels naturally occurring in human urines and the limits of quantification of the LC-MS/MS methodologies used by the participating laboratories. The results of each laboratory were evaluated for their z-score values. The percentage of satisfactory z-scores (vertical bar z vertical bar 2) were obtained for fumonisin B-1 (7/12 results), ochratoxin A (4/8 results) and alpha-zearalenol (1/8 results). The percentage of satisfactory z-scores for fumonisin B-1 and ochratoxin A increased from 42 to 83% for fumonisin B-1 and from 50 to 62% for ochratoxin A when laboratories 1 and 2 used own calibrants. Factors that could explain the different results obtained for fumonisin B-1 and ochratoxin A with provided and own calibration solutions could not be identified in this study and should be carefully investigated in future studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel photocatalytic reactor has been developed to remediate oily wastewaters. In the first instance degradation rates of model organic compounds, methylene blue (MB) and 4-c hlorophenol (4-CP) were determined. The experimental set-up investigated a 1:10 w/v catalyst to organic solution volume, 30 g catalyst, 300 mls MB (10 μM) or 4-CP (100 μM). The catalyst investigated was a pellet catalyst to improve separation of the remediated volume from the catalyst following treatment. MB concentration decreased by 93% after 15 mins irradiation whilst 4-CP concentration decreased by 94% following 90 mins irradiation. Oily waste water (OWW) from an interceptor tank typically containing diesel oils was obtained from Sureclean, an environmental clean-up company. The OWW was treated using the same conditions as MB and 4-CP, the model organic compounds. Levels of total organic carbon (TOC) and total petroleum hydrocarbon (TPH) were used to monitor the efficacy of the photocatalytic reactor. TOC reduced by 45% following two 90 mins treatment cycles. TPH reduced by 45% following 90 mins irradiation and by a further 25% during a second stage of treatment. This reactor can be used as a polishing technique assembled within a wastewater treatment plant. Allowing for more than one pass through the reactor improves its efficiency. 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Intake of heterocyclic amines (HCAs, carcinogens produced during cooking of meat/fish, the most abundant being PhIP, DiMeIQx and MeIQx) is influenced by many factors including type/thickness of meat and cooking method/temperature/duration. Thus, assessment of HCA dietary exposure is difficult. Protein adducts of HCAs have been proposed as potential medium-term biomarkers of exposure, e.g. PhIP adducted to serum albumin or haemoglobin. However, evidence is still lacking that HCA adducts are viable biomarkers in humans consuming normal diets. The FoodCAP project, supported by World Cancer Research Fund, developed a highly sensitive mass spectrometric method for hydrolysis, extraction and detection of acid-labile HCAs in blood and assessed their validity as biomarkers of exposure. Multiple acid/alkaline hydrolysis conditions were assessed, followed by liquid-liquid extraction, clean-up by cation-exchange SPE and quantification by UPLC-ESI-MS/ MS. Blood was analysed from volunteers who completed food diaries to estimate HCA intake based on the US National Cancer Institute’s CHARRED database. Standard HCAs were recovered quantitatively from fortified blood. In addition, PhIP/MeIQx adducts bound to albumin and haemoglobin prepared in vitro using a human liver microsome system were also detectable in blood fortified at low ppt concentrations. However, except for one sample (5pg/ml PhIP), acid-labile PhIP, 7,8-DiMeIQx, 4,8-DiMeIQx and MeIQx were not observed above the 2pg/ml limit of detection in plasma (n=35), or in serum, whole blood or purified albumin, even in volunteers with high meat consumption (nominal HCA intake >2µg/day). It is concluded that HCA blood protein adducts are not viable biomarkers of exposure. Untargeted metabolomic analyses may facilitate discovery of suitable markers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Semiconductor-sensitised photocatalysis is a well-established and growing area of research, innovation and commercialisation; the latter being mostly limited to the use of TiO2 as the semiconductor. Most of the work on semiconductor photocatalytic systems uses oxygen as the electron acceptor and explores a wide range of electron donors; such systems can be considered to be examples of oxidative photocatalysis, OP. OP underpins most current examples of commercial self-cleaning materials, such as: glass, tiles, concrete, paint and fabrics. OP, and its myriad of applications, have been reviewed extensively over the years both in this journal and elsewhere. However, the ability of TiO2, and other semiconductor sensitisers, to promote reductive photocatalysis, RP, especially of dyes, is significant and, although less well-known, is of growing importance. In such systems, the source of the electrons is some easily oxidised species, such as glycerol. One recent, significant example of a RP process is with respect to photocatalyst activity indicator inks. paiis, which provide a measure of the activity of a photocatalytic film under test via the rate of change of colour of the dye in the ink coating due to irreversible RP. In contrast, by incorporating the semiconductor sensitiser in the ink, rather than outside it, it is possible to create an effective UV dosimeter, based on RP, which can be used as a sun-burn warning indicator. In the above examples the dye is reduced irreversibly, but when the photocatalyst in an ink is used to reversibly photoreduce a dye, a novel, colourimetric oxygen-sensitive indicator ink can be created, which has commercial potential in the food packaging industry. Finally, if no dye is present in the ink, and the semiconductor photocatalyst-loaded ink film coats an easily reduced substrate, such as a metal oxide film, then it can be used to reduce the latter and so, for example, clean up tarnished steel. The above are examples of smart inks, i.e. inks that are active and provide either dynamic information (such as UV dose or O2 level) or a useful function (such as tarnish removal), and all work via a RP process and are reviewed here

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The potential of ectomycorrhizal (ECM) associations to facilitate clean-up of soil contaminated with persistent organic pollutants (POPs) is considered. Most ECM fungi screened for degradation of POPs (e.g. polyhalogenated biphenyls, polyaromatic hydrocarbons, chlorinated phenols, and pesticides) are able to transform these compounds. Mineralization of toluene, tetrachloroethylene and 2,4-dichlorophenol in intact ECM-association rhizospheres has also been demonstrated. We review and consider the likely mechanisms by which ECM fungi can transform pollutants, the extent to which these capabilities may be utilized practically in bioremediation, along with the potential advantages and disadvantages of using ECM associations in bioremediation. (C) 2000 Elsevier Science Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Glibenclamide (GLIB), an oral antidiabetic medication of the sulphonylurea drugs family, was stoichiometrically imprinted using tetrabutylammonium methacrylate as the functional monomer, for the first time in molecular imprinting, and utilising the sulphonylurea affinity for carboxylate anions. Solution association between the drug and the novel functional monomer was studied by 1H-NMR titrations, whereby evidence of sulphonylurea deprotonation followed by the formation of “narcissistic” GLIB dimers was found when tested in CDCl3, while an affinity constant in excess of 105 L mol-1 was measured in DMSO-d6. Detailed analysis of GLIB binding on the subsequently prepared imprinted and non-imprinted polymers confirmed deactivation of binding sites by exchange of a proton between GLIB and methacrylate, followed by extraction of the tetrabutylammonium counterion from the polymer matrix, resulting in overall reduced binding capacities and affinities by the imprinted material under equilibrium conditions. An optimised MI-SPE protocol, which included a binding site re-activation step, was developed for the extraction of GLIB from blood serum, whereby recoveries of up to 92.4% were obtained with exceptional sample clean-up.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O Mercúrio é um dos metais pesados mais tóxicos existentes no meio ambiente, é persistente e caracteriza-se por bioamplificar e bioacumular ao longo da cadeia trófica. A poluição com mercúrio é um problema à escala global devido à combinação de emissões naturais e emissões antropogénicas, o que obriga a políticas ambientais mais restritivas sobre a descarga de metais pesados. Consequentemente o desenvolvimento de novos e eficientes materiais e de novas tecnologias para remover mercúrio de efluentes é necessário e urgente. Neste contexto, alguns materiais microporosos provenientes de duas famílias, titanossilicatos e zirconossilicatos, foram investigados com o objectivo de avaliar a sua capacidade para remover iões Hg2+ de soluções aquosas. De um modo geral, quase todos os materiais estudados apresentaram elevadas percentagens de remoção, confirmando que são bons permutadores iónicos e que têm capacidade para serem utilizados como agentes descontaminantes. O titanossilicato ETS-4 foi o material mais estudado devido à sua elevada eficiência de remoção (>98%), aliada à pequena quantidade de massa necessária para atingir essa elevada percentagem de remoção. Com apenas 4 mg⋅dm-3 de ETS-4 foi possível tratar uma solução com uma concentração igual ao valor máximo admissível para descargas de efluentes em cursos de água (50 μg⋅dm-3) e obter água com qualidade para consumo humano (<1.0 μg⋅dm-3), de acordo com a legislação Portuguesa (DL 236/98). Tal como para outros adsorbentes, a capacidade de remoção de Hg2+ do ETS- 4 depende de várias condições experimentais, tais como o tempo de contacto, a massa, a concentração inicial de mercúrio, o pH e a temperatura. Do ponto de vista industrial as condições óptimas para a aplicação do ETS-4 são bastante atractivas, uma vez que não requerem grandes quantidades de material e o tratamento da solução pode ser feito à temperatura ambiente. A aplicação do ETS-4 torna-se ainda mais interessante no caso de efluentes hospitalares, de processos de electro-deposição com níquel, metalúrgica, extracção de minérios, especialmente ouro, e indústrias de fabrico de cloro e soda cáustica, uma vez que estes efluentes apresentam valores de pH semelhantes ao valor de pH óptimo para a aplicação do ETS-4. A cinética do processo de troca iónica é bem descrita pelo modelo Nernst-Planck, enquanto que os dados de equilíbrio são bem ajustados pelas isotérmicas de Langmuir e de Freundlich. Os parâmetros termodinâmicos, ΔG° and ΔH° indicam que a remoção de Hg2+ pelo ETS-4 é um processo espontâneo e exotérmico. A elevada eficiência do ETS-4 é confirmada pelos valores da capacidade de remoção de outros materiais para os iões Hg2+, descritos na literatura. A utilização de coluna de ETS-4 preparada no nosso laboratório, para a remoção em contínuo de Hg2+ confirma que este material apresenta um grande potencial para ser utilizado no tratamento de águas. ABSTRACT: Mercury is one of the most toxic heavy metals, exhibiting a persistent character in the environment and biota as well as bioamplification and bioaccumulation along the food chain. Natural inputs combined with the global anthropogenic sources make mercury pollution a planetary-scale problem, and strict environmental policies on metal discharges have been enforced. The development of efficient new materials and clean-up technologies for removing mercury from effluents is, thus, timely. In this context, in my study, several microporous materials from two families, titanosilicates and zirconosilicates were investigated in order to assess their Hg2+ sorption capacity and removal efficiency, under different operating conditions. In general, almost all microporous materials studied exhibited high removal efficiencies, confirming that they are good ion exchangers and have potential to be used as Hg2+ decontaminant agents. Titanosilicate ETS-4 was the material most studied here, by its highest removal efficiency (>98%) and lowest mass necessary to attain it. Moreover, according with the Portuguese legislation (DL 236/98) it is possible to attain drinking water quality (i.e. [Hg2+]< 1.0 μg⋅dm-3) by treating a solution with a Hg2+ concentration equal to the maximum value admissible for effluents discharges into water bodies (50 μg⋅dm-3), using only 4 mg⋅dm-3 of ETS-4. Even in the presence of major freshwater cations, ETS-4 removal efficiency remains high. Like for other adsorbents, the sorption capacity of ETS-4 for Hg2+ ions is strongly dependent on the operating conditions, such as contact time, mass, initial Hg2+ concentration and solution pH and, to a lesser extent, temperature. The optimum operating conditions found for ETS-4 are very attractive from the industrial point of view because the application of ETS-4 for the treatment of wastewater and/or industrial effluents will not require larges amounts of adsorbent, neither energy supply for temperature adjustments becoming the removal process economically competitive. These conditions become even more interesting in the case of medical institutions liquid, nickel electroplating process, copper smelter, gold ore tailings and chlor-alkali effluents, since no significant pH adjustments to the effluent are necessary. The ion exchange kinetics of Hg2+ uptake is successfully described by the Nernst-Planck based model, while the ion exchange equilibrium is well fitted by both Langmuir and Freundlich isotherms. Moreover, the feasibility of the removal process was confirmed by the thermodynamic parameters (ΔG° and ΔH°) which indicate that the Hg2+ sorption by ETS-4 is spontaneous and exothermic. The higher efficiency of ETS-4 for Hg2+ ions is corroborate by the values reported in literature for the sorption capacity of other adsorbents for Hg2+ ions. The use of an ETS-4 fixed-bed ion exchange column, manufactured in our laboratory, in the continuous removal of Hg2+ ions from solutions confirms that this titanosilicate has potential to be used in industrial water treatment.