990 resultados para chemical separation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined procedure for separating Lu, Hf, Sm, Nd, and rare earth elements (REEs) from a single sample digest is presented. The procedure consists of the following five steps: (1) sample dissolution via sodium peroxide sintering; (2) separation of the high field strength elements from the REEs and other matrix elements by a HF-free anion-exchange column procedure; (3) purification of Hf on a cation-exchange resin; (4) separation of REEs from other matrix elements by cation exchange; (5) Lu, Sm, and Nd separation from the other REEs by reversed-phase ion chromatography. Analytical reproducibilities of Sm-Nd and Lu-Hf isotope systematics are demonstrated for standard solutions and international rock reference materials. Results show overall good reproducibilities for Sm-Nd systematics independent of the rock type analyzed. For the Lu-Hf systematics, the reproducibility of the parent/daughter ratio is much better for JB-1 (basalt) than for two analyzed felsic crustal rocks (DR-N and an Archaean granitoid). It is demonstrated that this poorer reproducibility of the Lu/Hf ratio is truly caused by sample heterogeneity; thus, results are geologically reasonable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chemical contamination of natural waters is a global problem with a worldwide impact. Considering the relevance of this problem, this thesis is intended, on one hand, to develop different separation/preconcentration techniques based on membranes ability to permeate anions for the transport of toxic oxyanions of chromium(VI) and arsenic contained in aqueous matrices. In particular, we have investigated supported liquid membranes and polymer inclusion membranes, both of which contain the commercial quaternary ammonium salt Aliquat 336 as a carrier, as well as commercial anion exchange membranes. On the other hand, we have focused on the development of chemical sensors to facilitate the monitoring of several metals from different aqueous matrices. Thus, a selective optical sensor for Cr(VI) based on polymeric membranes containing Aliquat 336 as an ionophore has been designed. Additionally, mercury-based screen-printed electrodes have been evaluated for for cadmium, lead, copper and zinc detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A future goal in nuclear fuel reprocessing is the conversion or transmutation of the long-lived radioisotopes of minor actinides, such as americium, into short-lived isotopes by irradiation with neutrons. In order to achieve this transmutation, it is necessary to separate the minor actinides(III), [An(Ill)], from the lanthanides(III), [Ln(Ill)], by solvent extraction (partitioning), because the lanthanides absorb neutrons too effectively and hence limit neutron capture by the transmutable actinides. Partitioning using ligands containing only carbon, hydrogen, nitrogen and oxygen atoms is desirable because they are completely incinerable and thus the final volume of waste is minimised [1]. Nitric acid media will be used in the extraction experiments because it is envisaged that the An(III)/Ln(III) separation process could take place after the PUREX process. There is no doubt that the correct design of a molecule that is capable of acting as a ligand or extraction reagent is required for the effective separation of metal ions such as actinides(III) from lanthanides. Recent attention has been directed towards heterocyclic ligands with for the preferential separation of the minor actinides. Although such molecules have a rich chemistry, this is only now becoming sufficiently well understood in relation to the partitioning process [2]. The molecules shown in Figures I and 2 will be the principal focus of this study. Although the examples chosen here are used rather specific, the guidelines can be extended to other areas such as the separation of precious metals [3].

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The partitioning of Green Fluorescent Protein (GFP) in poly(ethylene glycol)/Na-poly(acrylate) aqueous two-phase systems (PEG/NaPA-ATPS) has been investigated. The aqueous two-phase systems are formed by mixing the polymers with a salt and a protein solution. The protein partitioning in the two-phase system was investigated at 25 degrees C. The concentration of the GFP was measured by fluorimetry. It was found that the partitioning of GFP depends on the salt type, pH and concentration of PEG. The data indicates that GFP partitions more strongly to the PEG phase in presence of Na2SO4 relative to NaCl. Furthermore, the GFP partitions more to the PEG phase at higher pH. The partition to the PEG phase is strongly favoured in systems with larger tie-line lengths (i.e. systems with higher polymer concentrations). The molecular weight of PEG is important since the partition coefficient (K) of GFP gradually decreases with increasing PEG size, from K ca. 300-400 for PEG 400 to K equal to 1.19 for PEG 8000. A separation process was developed where GFP was separated from a homogenate in two extraction steps: the GFP is first partitioned to the PEG phase in a PEG 3000/NaPA 8000 system containing 3 wt% Na2SO4, where the K value of GFP was 8. The GFP is then re-extracted to a salt phase formed by mixing the previous top-phase with a Na2SO4 solution. The K-value of GFP in this back-extraction was 0.22. The total recovery based on the start material was 74%. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A knowledge of the physical and chemical properties of superheavy elements is expected to be of great value for the detection of these elements, owing to the need for chemical separation in their isolation and identification. The methods for predicting their electronic structures, expected trends in their chemical and physical properties and the results of such predictions for the individual superheavy elements are reviewed. The periodic table is extended up to element 172.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette thèse a été réalisée en cotutelle. Pour la forme, Gérard Jasniewicz était mon codirecteur 'officiel' en France, bien que mon codirecteur était plutôt Olivier Richard qui m'a encadré lorsque j'étais en France.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurden Experimente auf verschiedenen Gebieten der chemischen Charakterisierung der schwersten Elemente durchgeführt. So wurden Vorarbeiten zur Elektrochemie der superschweren Elemente geleistet. Hier konnte gezeigt werden, dass sich Po aus verdünnten Säuren auf Metallelektroden spontan abscheiden lässt. Als wichtigste Reaktionsparameter wurden Temperatur, Konvektion und Viskosität des Elektrolyten identifiziert. Für die Elektrodeposition ist es von Bedeutung, reproduzierbar saubere Elektroden einzusetzen. Auch hierzu konnten Erkenntnisse gewonnen werden. Auf dem Gebiet der Charakterisierung von Nukliden wurde der Elektroneneinfang in Db-263 untersucht. Aus diesem Zerfall geht Rf-263 hervor, welches mit einer Halbwertszeit von 15min überwiegend durch Spontanspaltung zerfällt. Im Experiment wurde Rf-263 mittels Ionenaustauschchromatographie und nachfolgender Flüssig-Flüssig-Extraktion von Db und Aktiniden getrennt. Das erhaltene Präparat wurde auf Alpha-Zerfall und Spontanspaltung untersucht. Die Zahl der Rf-263 Zerfälle lässt auf einen Zerfallszweig durch Elektroneneinfang in Db-263 von 3% schließen. Ein Großteil der Arbeit beschäftigt sich mit der Bestimmung des Kd-Wertes von Sg am Anionenaustauscher Aminex A27 in 0.1M HNO3/5E-3M HF. Beim mit dem ALOHA-System durchgeführten Experiment wurde die Mehrsäulentechnik (MCT) erstmals für die wässrige Chemie von Sg genutzt. Aufgrund zahlreicher Probleme konnte letztlich kein Kd-Wert bestimmt werden. Stattdessen wurde das Experiment einer Fehleranalyse unterzogen. Hier zeigte sich eine Anfälligkeit der MCT auf natürliche Radionuklide. Weiterhin konnten Probleme bei ALOHA aufgedeckt werden, die eine Wiederholung des Experiments ausschlossen. In der Folge wurde ein alternativer Anionenaustauscher charakterisiert, sowie die Elektrolysebedingungen, als wichtiger Schritt der chemischen Aufarbeitung bei der MCT, genauer spezifiziert.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Non-invasive molecular-imaging technologies are playing a key role in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various deceases in vivo. However, it is limited by the availability of vectors with high selectivity to the target and radionuclides with a physical half-life which matches the biological half-life of the observed process. The 68Ge/68Ga radionuclide generator makes the PET-nuclide anywhere available without an on-site cyclotron. Besides the perfect availability 68Ga shows well suited nuclide properties for PET, but it has to be co-ordinated by a chelator to introduce it in a radiopharmaceuticals.rnHowever, the physical half-life of 68Ga (67.7 min) might limit the spectrum of clinical applications of 68Ga-labelled radiodiagnostics. Furthermore, 68Ga-labelled analogues of endoradiotherapeuticals of longer biological half-live such as 90Y- or 177Lu-labeled peptides and proteins cannot be used to determine individual radiation dosimetry directly. rnThus, radionuclide generator systems providing positron emitting daughters of extended physical half-life are of renewed interest. In this context, generator-derived positron emitters with longer physical half-life are needed, such as 72As (T½ = 26 h) from the 72Se/72As generator, or 44Sc (T½ = 3.97 h) from the 44Ti/44Sc generator.rnIn this thesis the implementation of radioactive gallium-68 and scandium-44 for molecular imaging and nuclear medical diagnosis, beginning with chemical separation and purification of 44Ti as a radionuclide mother, investigation of pilot generators with different elution mode, building a prototype generator, development and investigation of post-processing of the generator eluate, its concentration and further purification, the labeling chemistry under different conditions, in vitro and in vivo studies of labeled compounds and, finally, in vivo imaging experiments are described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79 as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The 146Sm–142Nd system plays a central role in tracing the silicate differentiation of the Earth prior to 4.1 Ga. After this time, given its initial abundance, the 146Sm can be considered to be extinct. Upadhyay et al. (2009) reported unexpected negative 142Nd anomalies in 1.48 Ga rocks of the Khariar nepheline syenite complex (India) and inferred that an early enriched, low-Sm/Nd reservoir must have contributed to the mantle source rocks of the Khariar complex. As 146Sm had been effectively extinct for about 2.6 billion years before the crystallisation of the Khariar samples, this Nd signature should have remained isolated from the convective mantle for at least that long. It was thus suggested that the source rock of Khariar samples had been sequestered in the lithospheric root of the Indian craton. Using a different chemical separation method, and a different Thermal Ionization Mass Spectrometry (TIMS) analysis protocol, the present study attempted to replicate these negative 142Nd anomalies, but none were found. To determine which data set is correct, we investigated three possible sources of bias between them: imperfect cancellation of Faraday collector efficiencies during multidynamic TIMS analysis, rapid sample fractionation between the sequential measurement of 146Nd/144Nd and 142Nd/144Nd, and non-exponential law behaviour resulting from so-called “domain mixing.” Incomplete cancellation of collector efficiencies was found unlikely to cause resolvable biases at the estimated level of variation among collector efficiencies. Even in the case of highly variable efficiency and resolvable biases, there is no reason to suspect that they would reproducibly affect only four rocks out of 10 analysed by Upadhyay et al. (2009). Although domain mixing may explain apparent “reverse” fractionation trends observed in some TIMS analyses, it cannot be the cause of the apparent negative anomalies in the study of Upadhyay et al. (2009). It was determined that rapid mass fractionation during the course of a multidynamic TIMS analysis can bias all measured Nd ratios. After applying an approximate correction for this effect, only one rock from Upadhyay et al. (2009) retained an apparent negative 142Nd anomaly. This, in conjunction with our new, anomaly-free data set measured at fractionation rates too low to cause bias, leads to the conclusion that the anomalies reported by Upadhyay et al. (2009) are a subtle and reproducible analytical artefact. The absence of negative 142Nd anomalies in these rocks relaxes the need for a mechanism (other than crust formation) that can isolate a Nd reservoir from the convective mantle for billions of years.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development and improvement of MC-ICP-MS instruments have fueled the growth of Lu–Hf geochronology over the last two decades, but some limitations remain. Here, we present improvements in chemical separation and mass spectrometry that allow accurate and precise measurements of 176Hf/177Hf and 176Lu/177Hf in high-Lu/Hf samples (e.g., garnet and apatite), as well as for samples containing sub-nanogram quantities of Hf. When such samples are spiked, correcting for the isobaric interference of 176Lu on 176Hf is not always possible if the separation of Lu and Hf is insufficient. To improve the purification of Hf, the high field strength elements (HFSE, including Hf) are first separated from the rare earth elements (REE, including Lu) on a first-stage cation column modified after Patchett and Tatsumoto (Contrib. Mineral. Petrol., 1980, 75, 263–267). Hafnium is further purified on an Ln-Spec column adapted from the procedures of Münker et al. (Geochem., Geophys., Geosyst., 2001, DOI: 10.1029/2001gc000183) and Wimpenny et al. (Anal. Chem., 2013, 85, 11258–11264) typically resulting in Lu/Hf < 0.0001, Zr/Hf < 1, and Ti/Hf < 0.1. In addition, Sm–Nd and Rb–Sr separations can easily be added to the described two-stage ion-exchange procedure for Lu–Hf. The isotopic compositions are measured on a Thermo Scientific Neptune Plus MC-ICP-MS equipped with three 1012 Ω resistors. Multiple 176Hf/177Hf measurements of international reference rocks yield a precision of 5–20 ppm for solutions containing 40 ppb of Hf, and 50–180 ppm for 1 ppb solutions (=0.5 ng sample Hf 0.5 in ml). The routine analysis of sub-ng amounts of Hf will facilitate Lu–Hf dating of low-concentration samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to determine geochemical compositions of Late Cenozoic Arctic seawater, oxide fractions were chemically separated from 15 samples of hand-picked ferromanganese micronodules (50-300 mu m). The success of the chemical separation is indicated by the fact that >97% of the Sr in the oxide fraction is seawater-derived. Rare-earth element (REE) abundances of the Arctic micronodule oxide fractions are much lower than those of bulk Fe-Mn nodules from other ocean basins of the world (e.g., 33 vs. 145 ppm Nd), but the Arctic oxides are enriched in Ce relative to Nd (Ce-N/Nd-N=2.2+/-0.5) and have convex-upward, shale-normalized REE patterns (Nd-N/Gd-N=0.61+/-0.06, Gd-N/Yb-N = 1.5+/-0.2, Nd-N/Yb-N = 0.9+/-0.2), typical of other hydrogenous and diagenetic marine Fe-Mn-oxides. Bulk sediment samples from the central Arctic Ocean have REE abundances and patterns that are characteristic of those of post-Archean shale. Non-detrital fractions (calcite + oxide coatings) of Recent Arctic foraminifera have REE abundances and patterns similar to those of Recent foraminifera from the Atlantic Ocean. Electron microprobe analyses (n=178) of transition elements in 29 Arctic Fe-Mn micronodules from five different stratigraphic intervals of Late Cenozoic sediment indicate that oxide accretion occurred as a result of hydrogenetic and diagenetic processes close to the sediment-seawater interface. Transition element ratios suggest that no oxide accretion occurred during transitions from oxic to suboxic diagenetic conditions. Only K is correlated with Si and Al, and ratios of these elements suggest that they are associated with illite or phillipsite. Ca and Mg are correlated with Mn, which indicates variable substitution of these elements from seawater into the manganate phase. The geochemical characteristics of Arctic Fe-Mn micronodules indicate that the REEs of the oxide fractions were ultimately derived from seawater. However, because of minute contributions of Sr from siliciclastic detritus during diagenesis or during the chemical leaching procedure, Sr isotope compositions of the oxide fractions cannot be used to trace temporal changes in the Sr-87/Sr-86 ratio of Arctic seawater or to improve the chronostratigraphy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Planaltina, Mestrado em Ciências de Materias, 2016.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)