64 resultados para charpy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprend : Les lymphatiques... Étude spéciale des lymphatiques des différentes parties du corps ; Système nerveux... Nerfs crâniens ; Les organes des sens. Le tégument externe et ses dérivés ; Oreille interne...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprend : Les lymphatiques... Étude spéciale des lymphatiques des différentes parties du corps ; Système nerveux... Nerfs crâniens ; Les organes des sens. Le tégument externe et ses dérivés ; Oreille interne...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprend : Les lymphatiques... Étude spéciale des lymphatiques des différentes parties du corps ; Système nerveux... Nerfs crâniens ; Les organes des sens. Le tégument externe et ses dérivés ; Oreille interne...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprend : Les lymphatiques... Étude spéciale des lymphatiques des différentes parties du corps ; Système nerveux... Nerfs crâniens ; Les organes des sens. Le tégument externe et ses dérivés ; Oreille interne...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The instrumentation applied to the Charpy test machine allows the accompaniment of the specimen answer front the impact load, in form of a sign characteristically dynamic representative of the deformation process and it fractures of material tested. The main advantages of the rehearsal conventional Charpy: low cost, manufacturing sample facilities and simple handle the machine. With the instrumentation, the number of information regarding the process of fracture of the specimen increases. In this work discusses the influence of the hammer geometry in determination of the force during the process of specimen fracture submitted to the instrumented impact test Charpy-V. The purpose is obtaining a hammer, in conformity with Norma ISO 14.556, with great sensibility to register the force during the impact. Two geometries different from hammers were instrumented and rehearsed with material of low tenacity, in this case the steel ABNT 4140 in the condition of having normalized. It could be proven as larger the sensibility of the hammer, adult will be the effects of the shock waves in the strain gages of the transducer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research project focused primarily on assessing the impact toughness of the weld and the base material of a steel pipe API 5L X70 submerged arc welded, used to conduct remote oil and gas (linepipes). The analysis followed strictly the Specification for Line Pipe - API 5L Standard, regarding the removal of the specimens of regions-of-proof-long section of the pipe, at 90o and 180o from the welded joint, and mechanical properties of toughness and Charpy-V, both the joint welded as the base material. Specimens of steel tube supplied by Tenaris Confab-SA were sized for tensile and Charpy-V, according to ASTM E 8M and ASTM E23, respectively. The result obtained showed that the API X70 steel tube has high Charpy-V toughness, near to each other at both 90o and 180o from the welded joint of the tube, and both higher than the weld metal. Microstructural and microhardness analysis complemented the present study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o decorrer dos anos o consumo de petróleo e seus derivados aumentou significativamente e com isso houve a necessidade de se investir em pesquisas para descobertas de novas jazidas de petróleo como o pré-sal. Porém, não apenas a localização dessas jazidas deve ser estudada, mas, também, sua forma de exploração. Essa exploração e extração, na maioria das vezes, se dão em ambientes altamente corrosivos e o transporte do produto extraído é realizado através de tubulações de aço de alta resistência e baixa liga (ARBL). Aços ARBL expostos a ambientes contendo H2S e CO2 (sour gas) sofrem corrosão generalizada que promovem a entrada de hidrogênio atômico no metal, podendo diminuir sua tenacidade e causar falha induzida pela presença de hidrogênio (Hydrogen Induced Cracking HIC), gerando falhas graves no material. Tais falhas podem ser desastrosas para o meio ambiente e para a sociedade. O objetivo deste trabalho é estudar a tenacidade, utilizando ensaio Charpy, de um tubo API 5L X65 sour após diferentes tempos de imersão em uma solução saturada com H2S. O eletrólito empregado foi a solução A (ácido acético contendo cloreto de sódio) da norma NACE TM0284 (2011), fazendo-se desaeração com injeção de N2, seguida de injeções de H2S. Os materiais foram submetidos a: ensaios de resistência a HIC segundo a norma NACE TM0284 (2011) e exames em microscópio óptico e eletrônico de varredura para caracterização microestrutural, de inclusões e trincas. As amostras foram submetidas a imersão em solução A durante 96h e 360h, sendo que, após doze dias do término da imersão, foram realizados os ensaios Charpy e exames fractográficos. Foram aplicados dois métodos: o de energia absorvida e o da expansão lateral, conforme recomendações da norma ASTM E23 (2012). As curvas obtidas, em função da temperatura de impacto, foram ajustadas pelo método da tangente hiperbólica. Esses procedimentos foram realizados nas duas seções do tubo (transversal e longitudinal) e permitiram a obtenção dos seguintes parâmetros: energias absorvidas e expansão lateral nos patamares superior e inferior e temperaturas de transição dúctil-frágil (TTDF) em suas diferentes definições, ou seja, TTDFEA, TTDFEA-DN, TTDFEA-FN, TTDFEL, TTDFEL-DN e TTDFEL-FN (identificação no item Lista de Abreviaturas e Siglas). No exame fractográfico observou-se que o material comportou-se conforme o previsto, ou seja, em temperaturas mais altas ocorreu fratura dúctil, em temperaturas próximas a TTDF obteve-se fratura mista e nas temperaturas mais baixas observou-se o aparecimento de fratura frágil. Os resultados mostraram que quanto maior o tempo de imersão na solução A, menor é a energia absorvida e a expansão lateral no patamar superior, o que pode ser explicado pelo (esperado) aumento do teor de hidrogênio em solução sólida com o tempo de imersão. Por sua vez, os resultados mostraram que há tendência à diminuição da temperatura de transição dúctil-frágil com o aumento do tempo de imersão, particularmente, as TTDFEA-DN e TTDFEL-DN das duas seções do tubo (longitudinal e transversal). Esse comportamento controverso, que pode ser denominado de tenacificação com o decorrer do tempo de imersão na solução A, foi explicado pelo aparecimento de trincas secundárias durante o impacto (Charpy). Isso indica uma limitação do ensaio Charpy para a avaliação precisa de materiais hidrogenados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effect of simulated microwave disinfection (SMD) on the linear dimensional changes, hardness and impact strength of acrylic resins under different polymerization cycles. Metal dies with referential points were embedded in flasks with dental stone. Samples of Classico and Vipi acrylic resins were made following the manufacturers' recommendations. The assessed polymerization cycles were: A-- water bath at 74ºC for 9 h; B-- water bath at 74ºC for 8 h and temperature increased to 100ºC for 1 h; C-- water bath at 74ºC for 2 h and temperature increased to 100ºC for 1 h;; and D-- water bath at 120ºC and pressure of 60 pounds. Linear dimensional distances in length and width were measured after SMD and water storage at 37ºC for 7 and 30 days using an optical microscope. SMD was carried out with the samples immersed in 150 mL of water in an oven (650 W for 3 min). A load of 25 gf for 10 sec was used in the hardness test. Charpy impact test was performed with 40 kpcm. Data were submitted to ANOVA and Tukey's test (5%). The Classico resin was dimensionally steady in length in the A and D cycles for all periods, while the Vipi resin was steady in the A, B and C cycles for all periods. The Classico resin was dimensionally steady in width in the C and D cycles for all periods, and the Vipi resin was steady in all cycles and periods. The hardness values for Classico resin were steady in all cycles and periods, while the Vipi resin was steady only in the C cycle for all periods. Impact strength values for Classico resin were steady in the A, C and D cycles for all periods, while Vipi resin was steady in all cycles and periods. SMD promoted different effects on the linear dimensional changes, hardness and impact strength of acrylic resins submitted to different polymerization cycles when after SMD and water storage were considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effect of simulated microwave disinfection (SMD) on the linear dimensional changes, hardness and impact strength of acrylic resins under different polymerization cycles. Metal dies with referential points were embedded in flasks with dental stone. Samples of Classico and Vipi acrylic resins were made following the manufacturers' recommendations. The assessed polymerization cycles were: A) water bath at 74 ºC for 9 h; B) water bath at 74 ºC for 8 h and temperature increased to 100 ºC for 1 h; C) water bath at 74 ºC for 2 h and temperature increased to 100 ºC for 1 h; and D) water bath at 120 ºC and pressure of 60 pounds. Linear dimensional distances in length and width were measured after SMD and water storage at 37 ºC for 7 and 30 days using an optical microscope. SMD was carried out with the samples immersed in 150 mL of water in an oven (650 W for 3 min). A load of 25 gf for 10 s was used in the hardness test. Charpy impact test was performed with 40 kpcm. Data were submitted to ANOVA and Tukey's test (5%). The Classico resin was dimensionally steady in length in the A and D cycles for all periods, while the Vipi resin was steady in the A, B and C cycles for all periods. The Classico resin was dimensionally steady in width in the C and D cycles for all periods, and the Vipi resin was steady in all cycles and periods. The hardness values for Classico resin were steady in all cycles and periods, while the Vipi resin was steady only in the C cycle for all periods. Impact strength values for Classico resin were steady in the A, C and D cycles for all periods, while Vipi resin was steady in all cycles and periods. SMD promoted different effects on the linear dimensional changes, hardness and impact strength of acrylic resins submitted to different polymerization cycles when after SMD and water storage were considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the impact and fracture resistance of acrylic resins: a heat-polymerized resin, a high-impact resin and an experimental polymethyl methacrylate with elastomer in different proportions (10, 20, 40 and 60%). 120 specimens were fabricated and submitted to conventional heat-polymerization. For impact test, a Charpy-type impact tester was used. Fracture resistance was assessed with a 3-point bending test by using a mechanical testing machine. Ten specimens were used for each test. Fracture (MPa) and impact resistance values (J.m-1) were submitted to ANOVA - Bonferroni's test - 5% significance level. Materials with higher amount of elastomer had statistically significant differences regarding to impact resistance (p < 0.05). Fracture resistance was superior (p < 0.01) for high-resistance acrylic resin. The increase in elastomer concentration added to polymethyl methacrylate raised the impact resistance and decreased the fracture resistance. Processing the material by injection decreased its resistance to impact and fracture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alpha prime formation leads to material embrittlement and deterioration of corrosion resistance. In the present study, the mechanical and corrosion behavior of super duplex stainless steel UNS S32520 aged at 475 degrees C from 0.5 h to 1,032 h was evaluated using microhardness measurements, Charpy impact tests, electrochemical impedance spectroscopy, and cyclic polarization curves. The sensibility of these tests to the effects of alpha prime phase was investigated. The microhardness test showed a gradual increase in hardness with aging time, whereas the impact tests revealed losses of about 80% in the energy absorption capacity for the material aged for 12 h in comparison with the solution-annealed samples. The most responsive analysis was the impact test, which indirectly revealed the presence of this deleterious phase in samples aged for 0.5 h. The electrochemical impedance spectroscopy and polarization tests were not highly sensitive to the alpha prime phase unless these are present in large amounts in the stainless steel.