971 resultados para catheter-related infection
Resumo:
PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.
Resumo:
Les infections liées aux accès vasculaires sont à l'origine d'une proportion importante des infections nosocomiales. Elles comprennent leur colonisation par des micro-organismes, les infections du site d'insertion et les bactériémies et fongémies qui leur sont associées ou attribuées. Une bactériémie complique l'insertion de 3 à 5 % des voies veineuses, correspondant à une incidence de 2 à 14 épisodes pour 1000 jourcathéters. Cette proportion ne représente toutefois que la partie visible de l'iceberg puisque la plupart des épisodes de sepsis clinique sans foyer infectieux associé sont également considérés comme liés aux accès vasculaires. Après un rappel de leur physiopathologie, cet article passe en revue les éléments importants pour leur prévention, y compris ceux concernant l'utilisation de cathéters imprégnés de désinfectants ou d'antibiotiques. Pour terminer, nous discutons en détail les stratégies préventives globales. Fondées sur la prise en compte d'un ensemble d'éléments spécifiques, ces approches sont centrées sur l'éducation du personnel au respect des règles d'hygiène de base et sur l'introduction de recommandations précises pour l'insertion et l'utilisation des accès vasculaires.
Resumo:
BACKGROUND: The risk of catheter-related infection or bacteremia, with initial and extended use of femoral versus nonfemoral sites for double-lumen vascular catheters (DLVCs) during continuous renal replacement therapy (CRRT), is unclear. STUDY DESIGN: Retrospective observational cohort study. SETTING & PARTICIPANTS: Critically ill patients on CRRT in a combined intensive care unit of a tertiary institution. FACTOR: Femoral versus nonfemoral venous DLVC placement. OUTCOMES: Catheter-related colonization (CRCOL) and bloodstream infection (CRBSI). MEASUREMENTS: CRCOL/CRBSI rates expressed per 1,000 catheter-days. RESULTS: We studied 458 patients (median age, 65 years; 60% males) and 647 DLVCs. Of 405 single-site only DLVC users, 82% versus 18% received exclusively 419 femoral versus 82 jugular or subclavian DLVCs, respectively. The corresponding DLVC indwelling duration was 6±4 versus 7±5 days (P=0.03). Corresponding CRCOL and CRBSI rates (per 1,000 catheter-days) were 9.7 versus 8.8 events (P=0.8) and 1.2 versus 3.5 events (P=0.3), respectively. Overall, 96 patients with extended CRRT received femoral-site insertion first with subsequent site change, including 53 femoral guidewire exchanges, 53 new femoral venipunctures, and 47 new jugular/subclavian sites. CRCOL and CRBSI rates were similar for all such approaches (P=0.7 and P=0.9, respectively). On multivariate analysis, CRCOL risk was higher in patients older than 65 years and weighing >90kg (ORs of 2.1 and 2.2, respectively; P<0.05). This association between higher weight and greater CRCOL risk was significant for femoral DLVCs, but not for nonfemoral sites. Other covariates, including initial or specific DLVC site, guidewire exchange versus new venipuncture, and primary versus secondary DLVC placement, did not significantly affect CRCOL rates. LIMITATIONS: Nonrandomized retrospective design and single-center evaluation. CONCLUSIONS: CRCOL and CRBSI rates in patients on CRRT are low and not influenced significantly by initial or serial femoral catheterizations with guidewire exchange or new venipuncture. CRCOL risk is higher in older and heavier patients, the latter especially so with femoral sites.
Resumo:
Este estudo prospectivo avaliou os métodos semiquantitativo e qualitativo de cultura de cateter para o diagnóstico de infecção relacionada a cateter (IRC) em recém-nascidos (RN). Foram incluídas pontas de cateteres provenientes de recém-nascidos internados na Unidade Neonatal do Hospital das Clínicas da Faculdade de Medicina de Botucatu, UNESP. Foram utilizadas as técnicas semiquantitativa e qualitativa de cultura de cateter. Para o diagnóstico de IRC, os microrganismos isolados das culturas de cateteres e de hemoculturas periféricas foram identificados e submetidos ao teste de sensibilidade a antimicrobianos. O padrão ouro correspondeu ao diagnóstico de certeza de IRC, com o isolamento do mesmo microrganismo (espécie e perfil de sensibilidade a antimicrobianos) isolado em hemocultura periférica. Foram estudados 85 cateteres provenientes de 63 RN. A cultura semiquantitativa, embora tenha apresentado menor sensibilidade (90%), apresentou uma maior especificidade (71%) em comparação à sensibilidade de 100% e especificidade de 60% encontradas na cultura qualitativa. Através da identificação dos microrganismos obtidos nas culturas de cateteres, observou-se uma predominância de espécies de Estafilococos coagulase-negativa (ECN). A espécie Staphylococcus epidermidis foi a prevalente (77,5%) nos cateteres com culturas semiquantitativas positivas. Dos 11 episódios de IRC diagnosticados, 8 (72,7%) foram associados a espécies de ECN, dos quais 6 eram da espécie S. epidermidis. Também foram detectados dois casos de IRC por S. aureus e um caso por Candida parapsilosis. O método de cultura semiquantitativo cateter apresentou vantagens para o diagnóstico de IRC em RN quando comparado com o método qualitativo tradicional.
Resumo:
An observational study was conducted in a SICU to determine the frequency of subclavian vein catheter-related infection at 72 hours, to identify the hospital cost of exchange via a guidewire and the estimated hospital cost-savings of a 72 hour vs 144 hour exchange policy.^ An overall catheter-related infection ($\geq$15 col. by Maki's technique (1977)) occurred in 3% (3/100) of the catheter tips cultured. Specific infections rates were: 9.7% (3/31) for triple lumen catheters, 0% (0/30) for Swan-Ganz catheters, 0% (0/30) for Cordes catheters, and 0% (0/9) for single lumen catheters.^ An estimated annual hospital cost-savings of $35,699.00 was identified if exchange of 72 hour policy were changed to every 144 hours.^ It was recommended that a randomized clinical trial be conducted to determine the effect of changing a subclavian vein catheter via a guidewire every 72 hours vs 144 hours. ^
Resumo:
Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.
Resumo:
The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.
Resumo:
Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
INTRODUCTION. Multimodal strategy targeted at prevention of catheter-related infection combine education to general measures of hygiene with specific guidelines for catheter insertion and dressing (1). OBJECTIVES. In this context, we tested the introduction of chlorhexidine(CHX)-impregnated sponges (2). METHODS. In our 32-beds mixed ICU, prospective surveillance of primary bacteremia and of microbiologically documented catheter-related bloodstream infections (CRBSI) is performed according to standardized definitions. New guidelines for central venous catheter (CVC) dressing combined a CHX-impregnated sponge (BioPatch_) with a transparent occlusive dressing (Tegaderm _) and planning for refection every 7 days. To contain costs, Biopatch_ was used only for internal jugular and femoral sites. Other elements of the prevention were not modified (overall compliance to hand hygiene 65-68%; non coated catheters except for burned patients [173 out of 9,542 patients];maximal sterile barriers for insertion; alcoholic solution ofCHXfor skin disinfection). RESULTS. Median monthly CVC-days increased from 710, to 749, 855 and 965 in 2006, 2007, 2008 and 2009, respectively (p\0.01). Following introduction of the new guidelines (4Q2007), the average monthly rate of infections decreased from 3.7 (95% CI: 2.6-4.8) episodes/1000 CVC-days over the 24 preceding months to 2.2 (95% CI: 1.5-2.8) over the 24 following months (p = 0.031). Dressings needed to be changed every 3-4 days. The decrease of catheter-related infections we observed in all consecutive admitted patients is comparable to that recently showed in a placeborandomized trial2. Further generalization to all CVC and arterial catheters access may be justified. CONCLUSIONS. Our data strongly suggest that combined with occlusive dressings, CHXimpregnated sponges for dressing of all CVC catheters inserted in internal jugular and/or femoral sites, significantly reduces the rate of primary bacteremia and CRBSI. REFERENCES. (1) Eggimann P, Harbarth S, Constantin MN, Touveneau S, Chevrolet JC, Pittet D. Impact of a prevention strategy targeted at vascular-access care on incidence of infections acquired in intensive care. Lancet 2000; 355:1864-1868. (2) Timsit JF, Schwebel C, Bouadma L, Geffroy A, Garrouste-Org, Pease S et al. Chlorhexidine- impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial. JAMA 2009; 301(12):1231-1241.
Resumo:
Concerning catheter-related infections, many studies have been conducted until the last consensus conference of the Sociétéde réanimation de langue française (SRLF) in 1994. This text is the synthesis of the considerable amount of work performed by the experts of the society to review recent studies. The experts' texts as well as extensive bibliography are available at http://www.srlf.org.
Resumo:
BACKGROUND: Early catheter-related infection is a serious complication in cancer treatment, although risk factors for its occurrence are not well established. The authors conducted a prospective study to identify the risk factors for developing early catheter-related infection. METHODS: All consecutive patients with cancer who underwent insertion of a central venous catheter were enrolled and were followed prospectively during 1 month. The study endpoint was occurrence of early catheter-related infection. RESULTS: Over 10,392 catheter-days of follow-up, 14 of 371 patients had early catheter-related infections (14 patients in 10,392 catheter-days or 1.34 per 1000 catheter-days). The causative pathogens were gram positive in 11 of 14 patients. In univariate analysis, the risk factors for early catheter-related infection were aged <10 years (P = .0001), difficulties during insertion (P < 10(-6)), blood product administration (P < 10(-3)), parenteral nutrition (P < 10(-4)), and use >2 days (P < 10(-6)). In multivariate analysis, 3 variables remained significantly associated with the risk of early catheter-related infection: age <10 years (odds ratio [OR], 18.4; 95% confidence interval [95% CI], 1.9-106.7), difficulties during insertion procedure (OR, 25.6; 95% CI, 4.2-106), and parenteral nutrition (OR, 28.5; 95% CI, 4.2-200). CONCLUSIONS: On the day of insertion, 2 variables were identified that were associated with a high risk of developing an early catheter-related infection: young age and difficulties during insertion. The results from this study may be used to identify patients who are at high risk of infection who may be candidates for preventive strategies.
Resumo:
2000 Mathematics Subject Classification: 62J12, 62P10.
Resumo:
La sospita de bacterièmia relacionada a catèter (BRC) necessita la retirada d’aquest, confirmant-se a posteriori només en un 15-25%. La diferencia en el temps de positivització d´ hemocultius (DTP) ha demostrat ser un mètode fiable per el diagnòstic de BRC evitant la retirada del catèter. Amb la intenció de comprovar la utilitat clínica de la DTP, l’hem comparada amb un mètode diagnòstic estàndard. Hem inclòs 133 pacients ingressats a una unitat de cures intensives portadors de catèters venosos centrals. 56 pacients s’han aleatoritzats. No hem trobat diferències significatives en quant a morbi-mortalitat en els 2 grups havent evitat 70% de retirada innecessària de catèters en el grup de DTP.
Resumo:
Background: Surveillance programmes have become the most effective tool for controlling catheter-related bloodstream infections (CRBSI). However, few studies have investigated programmes covering all hospital settings. Aim: To describe the results of a control and prevention programme for CRBSI based on compliance with recommendations for insertion and maintenance, using annual burden of disease in a tertiary level hospital. Methods: A CRBSI control and prevention programme involving all hospital settings was implemented. The programme consisted of CRBSI surveillance, direct observation of insertion and maintenance of catheters to determine performance, and education for healthcare workers. Findings: In total, 2043 short-term catheters were inserted in 1546 patients for 18,570 catheter-days, and 279 long-term catheters were inserted in 243 patients for 40,440 catheter-days. The annual incidence density was 5.98 (first semester 6.40, second semester 5.64) CRBSI per 1000 catheter-days for short-term catheters, and 0.57 (first semester 0.66, second semester 0.43) CRBSI per 1000 catheter-days for long-term catheters. One hundred and forty insertion procedures were observed, with an average insertion time of 13 (standard deviation 7) min. Compliance with recommendations was as follows: hand hygiene, 86.8%; use of alcoholic chlorhexidine solution for skin disinfection, 35.5%; use of mask, 93.4%; use of gloves, 98.7%; use of gown, 75.0%; use of sterile cloth, 93.8%; use of cap, 92.2%; bandage application, 62.7%; and use of aseptic technique, 89.5%. Forty-five maintenance procedures were observed, and compliance rates were as follows: hand hygiene, 42.1%; use of gloves, 78.1%; and port disinfection with alcoholic chlorhexidine solution, 32.5%. Conclusion: The CRBSI control and prevention programme implemented at the study hospital has decreased the rate of CRBSI, provided important information about the total burden of disease, and revealed possible ways to improve interventions in the future.