993 resultados para capillary separation techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) is a modern analytical technique, which is electrokinetic separation generated by high voltage and taken place inside the small capillaries. In this dissertation, several advanced capillary electrophoresis methods are presented using different approaches of CE and UV and mass spectrometry are utilized as the detection methods. ^ Capillary electrochromatography (CEC), as one of the CE modes, is a recent developed technique which is a hybrid of capillary electrophoresis and high performance liquid chromatography (HPLC). Capillary electrochromatography exhibits advantages of both techniques. In Chapter 2, monolithic capillary column are fabricated using in situ photoinitiation polymerization method. The column was then applied for the separation of six antidepressant compounds. ^ Meanwhile, a simple chiral separation method is developed and presented in Chapter 3. Beta cycodextrin was utilized to achieve the goal of chiral separation. Not only twelve cathinone analytes were separated, but also isomers of several analytes were enantiomerically separated. To better understand the molecular information on the analytes, the TOF-MS system was coupled with the CE. A sheath liquid and a partial filling technique (PFT) were employed to reduce the contamination of MS ionization source. Accurate molecular information was obtained. ^ It is necessary to propose, develop, and optimize new techniques that are suitable for trace-level analysis of samples in forensic, pharmaceutical, and environmental applications. Capillary electrophoresis (CE) was selected for this task, as it requires lower amounts of samples, it simplifies sample preparation, and it has the flexibility to perform separations of neutral and charged molecules as well as enantiomers. ^ Overall, the study demonstrates the versatility of capillary electrophoresis methods in forensic, pharmaceutical, and environmental applications.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) is a modern analytical technique, which is electrokinetic separation generated by high voltage and taken place inside the small capillaries. In this dissertation, several advanced capillary electrophoresis methods are presented using different approaches of CE and UV and mass spectrometry are utilized as the detection methods. Capillary electrochromatography (CEC), as one of the CE modes, is a recent developed technique which is a hybrid of capillary electrophoresis and high performance liquid chromatography (HPLC). Capillary electrochromatography exhibits advantages of both techniques. In Chapter 2, monolithic capillary column are fabricated using in situ photoinitiation polymerization method. The column was then applied for the separation of six antidepressant compounds. Meanwhile, a simple chiral separation method is developed and presented in Chapter 3. Beta cycodextrin was utilized to achieve the goal of chiral separation. Not only twelve cathinone analytes were separated, but also isomers of several analytes were enantiomerically separated. To better understand the molecular information on the analytes, the TOF-MS system was coupled with the CE. A sheath liquid and a partial filling technique (PFT) were employed to reduce the contamination of MS ionization source. Accurate molecular information was obtained. It is necessary to propose, develop, and optimize new techniques that are suitable for trace-level analysis of samples in forensic, pharmaceutical, and environmental applications. Capillary electrophoresis (CE) was selected for this task, as it requires lower amounts of samples, it simplifies sample preparation, and it has the flexibility to perform separations of neutral and charged molecules as well as enantiomers. Overall, the study demonstrates the versatility of capillary electrophoresis methods in forensic, pharmaceutical, and environmental applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the effect of semen storage and separation techniques on sperm DNA fragmentation. Design: Controlled clinical study. Setting: An assisted reproductive technology laboratory. Patient(s): Thirty normoozospermic semen samples obtained from patients undergoing infertility evaluation. Intervention(s): One aliquot from each sample was immediately prepared (control) for the sperm chromatin dispersion assay (SCD). Aliquots used to assess storage techniques were treated in the following ways: snap frozen by liquid nitrogen immersion, slow frozen with Tris-yolk buffer and glycerol, kept on ice for 24 hours or maintained at room temperature for 4 and 24 hours. Aliquots used to assess separation techniques were processed by the following methods: washed and centrifuged in media, swim-up from washed sperm pellet, density gradient separation, density gradient followed by swim-up. DNA integrity was then measured by SCD. Main Outcome Measure(s): DNA fragmentation as measured by SCD. Result(s): There was no significant difference in fragmentation among the snap frozen, slow frozen, and wet-ice groups. Compared to other storage methods short-term storage at room temperature did not impact DNA fragmentation yet 24 hours storage significantly increased fragmentation. Swim-up, density gradient and density gradient/swim-up had significantly reduced DNA fragmentation levels compared with washed semen. Postincubation, density gradient/swim-up showed the lowest fragmentation levels. Conclusion(s): The effect of sperm processing methods on DNA fragmentation should be considered when selecting storage or separation techniques for clinical use. (Fertil Steril (R) 2010;94:2626-30. (C) 2010 by American Society for Reproductive Medicine.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present a method for blind deconvolution of linear channels based on source separation techniques, for real word signals. This technique applied to blind deconvolution problems is based in exploiting not the spatial independence between signals but the temporal independence between samples of the signal. Our objective is to minimize the mutual information between samples of the output in order to retrieve the original signal. In order to make use of use this idea the input signal must be a non-Gaussian i.i.d. signal. Because most real world signals do not have this i.i.d. nature, we will need to preprocess the original signal before the transmission into the channel. Likewise we should assure that the transmitted signal has non-Gaussian statistics in order to achieve the correct function of the algorithm. The strategy used for this preprocessing will be presented in this paper. If the receiver has the inverse of the preprocess, the original signal can be reconstructed without the convolutive distortion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prediction filters are well known models for signal estimation, in communications, control and many others areas. The classical method for deriving linear prediction coding (LPC) filters is often based on the minimization of a mean square error (MSE). Consequently, second order statistics are only required, but the estimation is only optimal if the residue is independent and identically distributed (iid) Gaussian. In this paper, we derive the ML estimate of the prediction filter. Relationships with robust estimation of auto-regressive (AR) processes, with blind deconvolution and with source separation based on mutual information minimization are then detailed. The algorithm, based on the minimization of a high-order statistics criterion, uses on-line estimation of the residue statistics. Experimental results emphasize on the interest of this approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Darunavir, a protease inhibitor used in the treatment of HIV infection, presents few methods for its determination in pharmaceuticals. Infrared (IR) spectroscopy offers the possibility of obtaining spectra relatively quickly, providing interesting information, analytically, qualitatively or quantitatively. Capillary electrophoresis (CE) performs separations of high efficiency in shorter time with reagents and samples in small quantity. These two methods are cost-benefitted when we evaluate the green level and the cost of analysis. Faster and cheaper methods without generating organic waste by IR and CE for the quantification of darunavir were developed and validated, focusing socioeconomic impact of analytical decisions. If the cost of acquisition, maintenance, production, analysis and conditioning of drugs and pharmaceuticals is high, consequently the price of this product in the market will be higher and it cannot be accessible to the patient. Treatment failure not only affects the quality of life of patients, but also contributes significantly to the economic burden of the health system. In this context there is a tool called Analysis of the Life Cycle, which comes to make us think in a multidimensional way focusing the whole, the parts and especially the interaction among the parts of a system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays microfluidic is becoming an important technology in many chemical and biological processes and analysis applications. The potential to replace large-scale conventional laboratory instrumentation with miniaturized and self-contained systems, (called lab-on-a-chip (LOC) or point-of-care-testing (POCT)), offers a variety of advantages such as low reagent consumption, faster analysis speeds, and the capability of operating in a massively parallel scale in order to achieve high-throughput. Micro-electro-mechanical-systems (MEMS) technologies enable both the fabrication of miniaturized system and the possibility of developing compact and portable systems. The work described in this dissertation is towards the development of micromachined separation devices for both high-speed gas chromatography (HSGC) and gravitational field-flow fractionation (GrFFF) using MEMS technologies. Concerning the HSGC, a complete platform of three MEMS-based GC core components (injector, separation column and detector) is designed, fabricated and characterized. The microinjector consists of a set of pneumatically driven microvalves, based on a polymeric actuating membrane. Experimental results demonstrate that the microinjector is able to guarantee low dead volumes, fast actuation time, a wide operating temperature range and high chemical inertness. The microcolumn consists of an all-silicon microcolumn having a nearly circular cross-section channel. The extensive characterization has produced separation performances very close to the theoretical ideal expectations. A thermal conductivity detector (TCD) is chosen as most proper detector to be miniaturized since the volume reduction of the detector chamber results in increased mass and reduced dead volumes. The microTDC shows a good sensitivity and a very wide dynamic range. Finally a feasibility study for miniaturizing a channel suited for GrFFF is performed. The proposed GrFFF microchannel is at early stage of development, but represents a first step for the realization of a highly portable and potentially low-cost POCT device for biomedical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Research Institute, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper is to study metal separation from a sample composed of a mixture of the main types of spent household batteries, using a hydrometallurgical route, comparing selective precipitation and liquid-liquid extraction separation techniques. The preparation of the solution consisted of: grinding the waste of mixed batteries, reduction and volatile metals elimination using electric furnace and acid leaching. From this solution two different routes were studied: selective precipitation with sodium hydroxide and liquid-liquid extraction using Cyanex 272 [bis(2,4,4-trimethylpentyl) phosphoric acid] as extracting agent. The best results were obtained from liquid-liquid extraction in which Zn had a 99% extraction rate at pH 2.5. More than 95% Fe was extracted at pH 7.0, the same pH at which more than 90% Ce was extracted. About 88% Mn, Cr and Co was extracted at this pH. At pH 3.0, more than 85% Ni was extracted, and at pH 3.5 more than 80% of Cd and La was extracted. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Résumé La protéomique basée sur la spectrométrie de masse est l'étude du proteome l'ensemble des protéines exprimées au sein d'une cellule, d'un tissu ou d'un organisme - par cette technique. Les protéines sont coupées à l'aide d'enzymes en plus petits morceaux -les peptides -, et, séparées par différentes techniques. Les différentes fractions contenant quelques centaines de peptides sont ensuite analysées dans un spectromètre de masse. La masse des peptides est enregistrée et chaque peptide est séquentiellement fragmenté pour en obtenir sa séquence. L'information de masse et séquence est ensuite comparée à une base de données de protéines afin d'identifier la protéine d'origine. Dans une première partie, la thèse décrit le développement de méthodes d'identification. Elle montre l'importance de l'enrichissement de protéines comme moyen d'accès à des protéines de moyenne à faible abondance dans le lait humain. Elle utilise des injections répétées pour augmenter la couverture en protéines et la confiance dans l'identification. L'impacte de nouvelle version de base de données sur la liste des protéines identifiées est aussi démontré. De plus, elle utilise avec succès la spectrométrie de masse comme alternative aux anticorps, pour valider la présence de 34 constructions de protéines pathogéniques du staphylocoque doré exprimées dans une souche de lactocoque. Dans une deuxième partie, la thèse décrit le développement de méthodes de quantification. Elle expose de nouvelles approches de marquage des terminus des protéines aux isotopes stables et décrit la première méthode de marquage des groupements carboxyliques au niveau protéine à l'aide de réactifs composé de carbone 13. De plus, une nouvelle méthode, appelée ANIBAL, marquant tous les groupements amines et carboxyliques au niveau de la protéine, est exposée. Summary Mass spectrometry-based proteomics is the study of the proteome -the set of all expressed proteins in a cell, tissue or organism -using mass spectrometry. Proteins are cut into smaller pieces - peptides - using proteolytic enzymes and separated using different separation techniques. The different fractions containing several hundreds of peptides are than analyzed by mass spectrometry. The mass of the peptides entering the instrument are recorded and each peptide is sequentially fragmented to obtain its amino acid sequence. Each peptide sequence with its corresponding mass is then searched against a protein database to identify the protein to which it belongs. This thesis presents new method developments in this field. In a first part, the thesis describes development of identification methods. It shows the importance of protein enrichment methods to gain access to medium-to-low abundant proteins in a human milk sample. It uses repeated injection to increase protein coverage and confidence in identification and demonstrates the impact of new database releases on protein identification lists. In addition, it successfully uses mass spectrometry as an alternative to antibody-based assays to validate the presence of 34 different recombinant constructs of Staphylococcus aureus pathogenic proteins expressed in a Lactococcus lactis strain. In a second part, development of quantification methods is described. It shows new stable isotope labeling approaches based on N- and C-terminus labeling of proteins and describes the first method of labeling of carboxylic groups at the protein level using 13C stable isotopes. In addition, a new quantitative approach called ANIBAL is explained that labels all amino and carboxylic groups at the protein level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tässä työssä tutkittiin Stora Enso Oyj:n Heinolan Flutingtehtaan voimalaitos- ja jätevesien seuranta-analyysimenetelmien kehittämistä. Käytössä olevia menetelmiä vertailtiin vaihtoehtoisiin uusiin menetelmiin, jotka perustuvat erotustekniikoihin ja automaatioon. Flutingtehtaalla nykyisin käytössä olevat analyysimenetelmät perustuvat suurelta osin standardimäärityksiin, joissa käytetään pääasiassa titrausta. Määritykset vievät paljon aikaa, koska titraukset toteutetaan manuaalisesti. Titrausten päätepisteet tulkitaan esim. indikaattorin värinmuutoksella ja saostamalla, joten määritysten tarkkuus vaihtelee. Kokeellisessa osassa Flutingtehtaan puhtaista voimalaitosvesistä yhdistetty sekoitenäyte analysoitiin kahdella ionikromatografilla, liekkiatomiabsorptiospektrometrillä ja kapillaarielektroforeesilla. Yksittäisiä näytteitä ei tutkittu. Lisäksi vesilaboratoriossa määritettävistä jätevesistä yhdistettiin sekoitenäyte, joka analysoitiin kapillaarielektroforeesilla. Samat sekoitenäytteet analysoitiin myös nykyisillä menetelmillä tehtaan vesilaboratoriossa. Tulokset osoittivat, että kokeellisessa osassa tutkitut menetelmät soveltuvat sekoitenäytteen perusteella hyvin vesilaboratoriossa käytössä oleviin kuukausianalyyseihin. Automaattisella näytteensyötöllä varustettuna kaikki kolme kokeellisessa osassa tutkittua menetelmää ovat yksikertaisia käyttää ja ne nopeuttavat analyysejä. Päivittäisiä titrausanalyysejä voidaan tehostaa ja nopeuttaa automaation avulla. Erotustekniikoilla esimerkiksi typpi voidaan määrittää kokonaistyppenä, mutta myös komponentteinaan eli ammoniakkina, nitraattina ja nitriittinä. Lisäksi samalla erotuksella voidaan määrittää useita alkali- ja maa-alkalimetalleja sekä raskas-metalleja toistomittauksilla. Menetelmän käyttöalue on laajempi erotustekniikoilla kuin perinteisillä liuoskemian mittauksilla. Erotustekniikoilla tunnistetaan helposti määritysten oikeellisuus detektointimahdollisuuksien monipuolisuuden vuoksi.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Preparative liquid chromatography is one of the most selective separation techniques in the fine chemical, pharmaceutical, and food industries. Several process concepts have been developed and applied for improving the performance of classical batch chromatography. The most powerful approaches include various single-column recycling schemes, counter-current and cross-current multi-column setups, and hybrid processes where chromatography is coupled with other unit operations such as crystallization, chemical reactor, and/or solvent removal unit. To fully utilize the potential of stand-alone and integrated chromatographic processes, efficient methods for selecting the best process alternative as well as optimal operating conditions are needed. In this thesis, a unified method is developed for analysis and design of the following singlecolumn fixed bed processes and corresponding cross-current schemes: (1) batch chromatography, (2) batch chromatography with an integrated solvent removal unit, (3) mixed-recycle steady state recycling chromatography (SSR), and (4) mixed-recycle steady state recycling chromatography with solvent removal from fresh feed, recycle fraction, or column feed (SSR–SR). The method is based on the equilibrium theory of chromatography with an assumption of negligible mass transfer resistance and axial dispersion. The design criteria are given in general, dimensionless form that is formally analogous to that applied widely in the so called triangle theory of counter-current multi-column chromatography. Analytical design equations are derived for binary systems that follow competitive Langmuir adsorption isotherm model. For this purpose, the existing analytic solution of the ideal model of chromatography for binary Langmuir mixtures is completed by deriving missing explicit equations for the height and location of the pure first component shock in the case of a small feed pulse. It is thus shown that the entire chromatographic cycle at the column outlet can be expressed in closed-form. The developed design method allows predicting the feasible range of operating parameters that lead to desired product purities. It can be applied for the calculation of first estimates of optimal operating conditions, the analysis of process robustness, and the early-stage evaluation of different process alternatives. The design method is utilized to analyse the possibility to enhance the performance of conventional SSR chromatography by integrating it with a solvent removal unit. It is shown that the amount of fresh feed processed during a chromatographic cycle and thus the productivity of SSR process can be improved by removing solvent. The maximum solvent removal capacity depends on the location of the solvent removal unit and the physical solvent removal constraints, such as solubility, viscosity, and/or osmotic pressure limits. Usually, the most flexible option is to remove solvent from the column feed. Applicability of the equilibrium design for real, non-ideal separation problems is evaluated by means of numerical simulations. Due to assumption of infinite column efficiency, the developed design method is most applicable for high performance systems where thermodynamic effects are predominant, while significant deviations are observed under highly non-ideal conditions. The findings based on the equilibrium theory are applied to develop a shortcut approach for the design of chromatographic separation processes under strongly non-ideal conditions with significant dispersive effects. The method is based on a simple procedure applied to a single conventional chromatogram. Applicability of the approach for the design of batch and counter-current simulated moving bed processes is evaluated with case studies. It is shown that the shortcut approach works the better the higher the column efficiency and the lower the purity constraints are.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La cellulose et ses dérivés sont utilisés dans un vaste nombre d’applications incluant le domaine pharmaceutique pour la fabrication de médicaments en tant qu’excipient. Différents dérivés cellulosiques tels que le carboxyméthylcellulose (CMC) et l’hydroxyéthylcellulose (HEC) sont disponibles sur le commerce. Le degré de polymérisation et de modification diffèrent énormément d’un fournisseur à l’autre tout dépendamment de l’origine de la cellulose et de leur procédé de dérivation, leur conférant ainsi différentes propriétés physico-chimiques qui leurs sont propres, telles que la viscosité et la solubilité. Notre intérêt est de développer une méthode analytique permettant de distinguer la différence entre deux sources d’un produit CMC ou HEC. L’objectif spécifique de cette étude de maitrise était l’obtention d’un profil cartographique de ces biopolymères complexes et ce, par le développement d’une méthode de digestion enzymatique donnant les oligosaccharides de plus petites tailles et par la séparation de ces oligosaccharides par les méthodes chromatographiques simples. La digestion fut étudiée avec différents paramètres, tel que le milieu de l’hydrolyse, le pH, la température, le temps de digestion et le ratio substrat/enzyme. Une cellulase de Trichoderma reesei ATCC 26921 fut utilisée pour la digestion partielle de nos échantillons de cellulose. Les oligosaccharides ne possédant pas de groupements chromophores ou fluorophores, ils ne peuvent donc être détectés ni par absorbance UV-Vis, ni par fluorescence. Il a donc été question d’élaborer une méthode de marquage des oligosaccharides avec différents agents, tels que l’acide 8-aminopyrène-1,3,6-trisulfonique (APTS), le 3-acétylamino-6-aminoacridine (AA-Ac) et la phénylhydrazine (PHN). Enfin, l’utilisation de l’électrophorèse capillaire et la chromatographie liquide à haute performance a permis la séparation des produits de digestion enzymatique des dérivés de cellulose. Pour chacune de ces méthodes analytiques, plusieurs paramètres de séparation ont été étudiés.