971 resultados para bulk electrical resistivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical resistivity of bulk amorphous Al23T77 samples has been studied as a function of pressure (up to 80 kbar) and temperature (down to 77 K). At atmospheric pressure the temperature dependence of resistivity obeys the relation = π0 exp(δE/RT) with two activation energies. In the temperature range 300 K T > 234 K the activation energy is 0.58 eV and for 234 >T 185 K the value is δE = 0.30 ev. The activation energy has been measured as a function of pressure. The electrical resistivity decreases exponentially with the increase of pressure and at 70 kbar pressure the electrical behaviour of the sample shows a metallic nature with a positive temperature coefficient. The high pressure phase of the sample is found to be a crystalline hexagonal phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An irreversible pressure induced semiconductor-to-metal transition in bulk Ge20Te80 glass is observed at about 5 GPa pressure. The high pressure phase has a face centered cubic structure with a lattice constant 6.42 A° as deduced by X-ray diffraction studies on the pressure quenched samples. The temperature and pressure dependence of the electrical resistivity confirms the observed transition to be a semiconductor-to-metal transition. The temperature dependence of thermo electric power is also reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogeophysics is a growing discipline that holds significant promise to help elucidate details of dynamic processes in the near surface, built on the ability of geophysical methods to measure properties from which hydrological and geochemical variables can be derived. For example, bulk electrical conductivity is governed by, amongst others, interstitial water content, fluid salinity, and temperature, and can be measured using a range of geophysical methods. In many cases, electrical resistivity tomography (ERT) is well suited to characterize these properties in multiple dimensions and to monitor dynamic processes, such as water infiltration and solute transport. In recent years, ERT has been used increasingly for ecosystem research in a wide range of settings; in particular to characterize vegetation-driven changes in root-zone and near-surface water dynamics. This increased popularity is due to operational factors (e.g., improved equipment, low site impact), data considerations (e.g., excellent repeatability), and the fact that ERT operates at scales significantly larger than traditional point sensors. Current limitations to a more widespread use of the approach include the high equipment costs, and the need for site-specific petrophysical relationships between properties of interest. In this presentation we will discuss recent equipment advances and theoretical and methodological aspects involved in the accurate estimation of soil moisture from ERT results. Examples will be presented from two studies in a temperate climate (Michigan, USA) and one from a humid tropical location (Tapajos, Brazil).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seismic refraction and electrical resistivity geophysical techniques were used to reconstruct the internal architecture of a drumlin in Co. Down, Northern Ireland. Geophysical results were both validated and complemented by borehole drilling, ground water flow modelling, and geologic mapping. The geophysical anatomy of the drumlin consists of five successive layers with depth including; topsoil, partially saturated and saturated glacial tills, and weathered and more competent greywacke bedrock. There are numerous, often extensive inclusions of clay, sand, gravel, cobbles, and boulders within the topsoil and the till units. Together geophysical and geotechnical findings imply that the drumlin is part of the subglacial lodgement, melt-out, debris flow, sheet flow facies described by previous authors, and formed by re-sedimentation and streamlining of pre-existing sediments during deglaciation of the Late Devensian ice sheet. Seismic refraction imaging is particularly well suited to delineating layering within the drumlin, and is able to reconstruct depths to interfaces to within ± 0.5 m accuracy. Refraction imaging ascertained that the weathered bedrock layer is continuous and of substantial thickness, so that it acts as a basal aquifer which underdrains the bulk of the drumlin. Electrical resistivity imaging was found to be capable of delineating relative spatial changes in the moisture content of the till units, as well as mapping sedimentary inclusions within the till. The moisture content appeared to be elevated near the margins of the drumlin, which may infer a weakening of the drumlin slopes. Our findings advocate the use of seismic refraction and electrical resistivity methods in future sedimentological and geotechnical studies of internal drumlin architecture and drumlin formation, owing particularly to the superior, 3- D spatial coverage of these methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, considerable efforts have been made in the attempt to map quick clay areas using electrical resistivity measurements. However there is a lack of understanding regarding which soil parameters control the measured resistivity values. To address this issue, inverted resistivity values from 15 marine clay sites in Norway have been compared with basic geotechnical index properties. It was found that the resistivity value is strongly controlled by the salt content of the pore fluid. Resistivity decreases rapidly with increasing salt content. There is also a relatively clear trend of decreasing resistivity with increasing clay content and plasticity index. Resistivity values become very low (˜5 O·m) for high clay content (>50%), medium- to high-plasticity (Ip ˜ 20%) materials with salt content values greater than about 8 g/L (or corresponding remoulded shear strength values greater than 4 kPa). For the range of values studied, there is poor correlation between resistivity and bulk density and between resistivity and water content. The data studied suggest that the range of resistivity values corresponding to quick clay is 10 to 100 O·m, which is consistent with other published limits. A comparison is made between two-dimensional electrical resistivity tomography (ERT) and resistivity cone penetration test (RCPTU) data for two of the sites and the two sets of data show similar trends and values irrespective of scale effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magmatic fluids, heat fluxes, and fluid/rock interactions associated with hydrothermal systems along spreading centers and convergent margins have a significant impact on the genesis of major sulfide deposits and biological communities. Circulation of hydrothermal fluids is one of the most fundamental processes associated with localized mineralization and is controlled by inherent porous and permeable properties of the ocean crust. Heat from magmatic intrusions drives circulation of seawater through permeable portions of the oceanic crust and upper mantle, discharging at the seafloor as both focused high-temperature (250°-400°C) fluids and diffuse lower-temperature (<250°C) fluids. This complex interaction between the circulating hydrothermal fluids and the oceanic basement greatly influences the physical properties and the composition of the crust (Thompson, 1983; Jacobson, 1992, doi:10.1029/91RG02811; Johnson and Semyan, 1994, doi:10.1029/93JB00717). During Ocean Drilling Program (ODP) Leg 193, 13 holes were drilled in the PACMANUS hydrothermal system (Binns, Barriga, Miller, et al., 2002, doi:10.2973/odp.proc.ir.193.2002). The hydrothermal system consists of isolated hydrothermal deposits lined along the main crest of the Pual Ridge, a 500- to 700-m-high felsic neovolcanic ridge in the eastern Manus Basin. The principal drilling targets were the Snowcap (Site 1188) and Roman Ruins (Site 1189) active hydrothermal fields. Samples from these two sites were used for a series of permeability, electrical resistivity, and X-ray computed tomography measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crack is a significant influential factor in soil slope that could leads to rainfall-induced slope instability. Existence of cracks at soil surface will decrease the shear strength and increase the hydraulic conductivity of soil slope. Although previous research has shown the effect of surface-cracks in soil stability, the influence of deep-cracks on soil stability is still unknown. The limited availability of deep crack data due to the difficulty of effective investigate methods could be one of the obstacles. Current technology in electrical resistivity can be used to detect deep-cracks in soil. This paper discusses deep cracks in unsaturated residual soil slopes in Indonesia using electrical resistivity method. The field investigation such as bore hole and SPT tests was carried out at multiple locations in the area where the electrical resistivity testing have been conducted. Subsequently, the results from bore-hole and SPT test were used to verify the results of the electrical resistivity test. This study demonstrates the benefits and limitations of the electrical resistivity in detecting deep-cracks in a residual soil slopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thin films of expoxy nanocomposites modified by multiwall carbon nanotubes (MWCNTs) were prepared by shear mixing and spin casting. The electrical behaviour and its dependence with temperature between 243 and 353 degrees Kelvin were characterized by measuring the direct current (DC) conductivity. Depending on the fabrication process, both linear and non-linear relationships between conductivity and temperature were observed. In addition, the thermal history also played a role in dictating the conductivity. The implications of these observations for potential application of these files as strain sensors are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical resistivity of soils and sediments is strongly influenced by the presence of interstitial water. Taking advantage of this dependency, electrical-resistivity imaging (ERI) can be effectively utilized to estimate subsurface soil-moisture distributions. The ability to obtain spatially extensive data combined with time-lapse measurements provides further opportunities to understand links between land use and climate processes. In natural settings, spatial and temporal changes in temperature and porewater salinity influence the relationship between soil moisture and electrical resistivity. Apart from environmental factors, technical, theoretical, and methodological ambiguities may also interfere with accurate estimation of soil moisture from ERI data. We have examined several of these complicating factors using data from a two-year study at a forest-grassland ecotone, a boundary between neighboring but different plant communities.At this site, temperature variability accounts for approximately 20-45 of resistivity changes from cold winter to warm summer months. Temporal changes in groundwater conductivity (mean=650 S/cm =57.7) and a roughly 100-S/cm spatial difference between the forest and grassland had only a minor influence on the moisture estimates. Significant seasonal fluctuations in temperature and precipitation had negligible influence on the basic measurement errors in data sets. Extracting accurate temporal changes from ERI can be hindered by nonuniqueness of the inversion process and uncertainties related to time-lapse inversion schemes. The accuracy of soil moisture obtained from ERI depends on all of these factors, in addition to empirical parameters that define the petrophysical soil-moisture/resistivity relationship. Many of the complicating factors and modifying variables to accurately quantify soil moisture changes with ERI can be accounted for using field and theoretical principles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indium sulphide (INS) is a III-VI compound semiconductor and crystallizes in the orthorhombic structure with a space group D~(Pmnn). The lattice parameters at room temperature and atmospheric pressure are: a = 3.944 A, b = 4.447 A and c= 10.648#, [1, 2]. The crystal structure comprises an ethane-like SalnlnS3 atomic arrangement;the SalnInS3 groups are mutually linked by sharing S corners and form a three-dimensional network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ac susceptibility and electrical resistivity studies on polycrystalline Fe80-xNixCr20 (21 \leq x \leq 30) alloys, with x=21, 23, 26, and 30, between 4.2 and 80 K, are reported. A previous dc magnetization study indicated the presence of ferro-spin-glass mixed-phase behavior in x=23 and 26 alloys while the alloys with x=21 and 30 were found to be spin-glass and ferromagnetic, respectively. The present ac susceptibility results support the above picture. In the electrical resistivity study, a low-temperature minimum in the resistivity-temperature curve is observed in all the alloys except the ferromagnetic one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical resistance measurements are reported on the binary liquid mixtures CS2 + CH3CN and CS2 + CH3NO2 with special reference to the critical region. Impurity conduction seems to be the dominant mechanism for charge transport. For the liquid mixture filled at the critical composition, the resistance of the system aboveT c follows the relationR=R c−A(T−T c) b withb=0·6±0·1. BelowT c the conductivities of the two phases obey a relation σ2−σ1=B(T c−T)β with β=0·34±0·02, the exponent of the transport coefficient being the same as the exponent of the order parameter, an equilibrium property.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For five binary liquid systems CS2+CH3CN, CS2+CH3NO2, CS2+(CH3CO)2O, C6H12+(CH3CO)2O, n-C7H16+(CH3CO)2O, the electrical resistance has been measured near the critical solution temperatures. The behaviour is universal. Below Tc, the conductivities of the two phases follow σ1−σ2 β, where = T−Tc Tc with β≈0.35. In the one phase region with b≈0.35±0.1 and is positive in some cases and negative in others.