The aim of this study is to determine what factors constitute a quality prosthesis and ascertain which factors affect prosthesis satisfaction. Sixty-four women who received full funding for their prosthesis and 38 women who received their hospital’s usual fundingwere recruited. Women rated the information provided about breast prostheses very highly, with 85% reporting that it was "very good" or "excellent." Satisfaction was significantly associatedwith how well the prosthesis fit (1 week,p=.001; 3 months,p=.01), level of comfort (3 months,p=.005), and appearance of the prosthesis when worn (6 months,p = .001). Quality was significantly associated with how well it fit (1 week,p = .001; 3months,p = .001), how natural it felt (1 week,p = .001; 6months,p=.01), the weight of the prosthesis (3 months,p=.003), and appearance when worn (6 months,p = .03). The results will be used to improve women’s access to a quality prosthesis.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

After mastectomy, the provision of an appropriate breast prosthesis can help to improve body image and quality of life and reduce associated emotional distress. Although up to 90% of women use an external breast prosthesis after mastectomy, little is known about their experiences and satisfaction with breast prosthesis use. Focus groups were conducted with women who had been fitted with an external breast prosthesis, breast care nurses, and prosthesis fitters to explore women's experiences of prosthesis use. Qualitative thematic content analysis of focus group transcripts indicated that whereas women's initial reaction to the prosthesis generally was negative, this improved over time. Provision of adequate information and support, characteristics of the fitter and the fitting experience, and relationships with breast care nurses and prosthesis fitters were important to women's acceptance and satisfaction with their prosthesis. The study results highlighted the key role that breast care nurses play and the underestimation of the prosthesis fitter's role. Common themes concerning the impact of prosthesis use included body image, appearance, and feminine identity. These findings have important implications for professionals involved in the delivery of breast prostheses services.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although up to 90% of women who have had a mastectomy use breast prostheses, significant gaps exist around current breast prosthesis services for Australian women. These gaps include the timeliness and quality of information provision, the disparity in financial assistance, and the lack of knowledge regarding the determinants of what constitutes a "quality" breast prosthesis. Revised policy initiatives are central to addressing these gaps to ensure equitable access to quality breast prosthesis services.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

For many women, the only alternative to breast reconstruction following a mastectomy is to use external prostheses, which need replacing regularly at a cost of up to $395 per prosthesis. Commonwealth and state governments across Australia have responded to this need by providing subsidies to assist in the purchase of breast prostheses. However, current arrangements have been highly variable and sometimes difficult to access. As part of a larger review of breast pros-thesis services in Victoria, Australia, the aim of this research was to evaluate client satisfaction among Victorian women who accessed funds through the State Government's Aids and Equipment Program, compare the responses of the program service providers with the experiences of clients accessing funding, and identify opportunities to improve service provision.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The laryngeal mask has been frequently used in Anesthesiology. Although the rate of complications with this technique is smaller than that of the endotracheal tube, it is not devoid of risks, especially in cases of difficult airways. The objective of this study was to report a case of unilateral lingual nerve damage after the use of the laryngeal mask airway. CASE REPORT: A female patient underwent a surgical procedure for removal of bilateral breast prosthesis under general, balanced anesthesia, with a size three laryngeal mask. The balloon was inflated with 30 mL of air. After the first postoperative hour, she developed decreased sensation and pain in the oropharynx and posterior two thirds of the tongue, which evolved for loss of taste in the next 24 hours. A tentative diagnosis of lingual nerve neuropraxis secondary to the use of the laryngeal mask was made. After three weeks, her symptoms subsided. CONCLUSION: Although complications after the use of the laryngeal mask airway are rare, they do occur, and neuropraxis of the lingual nerve is one of them. The diagnosis is clinical and it has a good outcome, with resolution of the symptoms within a few weeks or months. © Sociedade Brasileira de Anestesiologia, 2007.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Capsular fibrosis is a severe complication after breast implantation with an uncertain etiology. Microbial colonization of the prosthesis is hypothesized as a possible reason for the low-grade infection and subsequent capsular fibrosis. Current diagnostic tests consist of intraoperative swabs and tissue biopsies. Sonication of removed implants may improve the diagnosis of implant infection by detachment of biofilms from the implant surface. METHODS: Breast implants removed from patients with Baker grades 3 and 4 capsular contracture were analyzed by sonication, and the resulting sonication fluid was quantitatively cultured. RESULTS: This study investigated 22 breast implants (6 implants with Baker 3 and 16 implants with Baker 4 capsular fibrosis) from 13 patients. The mean age of the patients was 49 years (range, 31-76 years). The mean implant indwelling time was 10.4 years (range, 3 months to 30 years). Of the 22 implants, 12 were used for breast reconstruction and 10 for aesthetic procedures. The implants were located subglandularly (n = 12), submuscularly (n = 6), and subcutaneously (n = 4). Coagulase-negative staphylococci, Propionibacterium acnes, or both were detected in the sonication fluid cultures of nine implants (41%), eight of which grew significant numbers of microorganisms (>100 colonies/ml of sonication fluid). CONCLUSIONS: Sonication detected bacteria in 41% of removed breast implants. The identified bacteria belonged to normal skin flora. Further investigation is needed to determine any causal relation between biofilms and capsular fibrosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Systemic inflammation after augmentation mammaplasty with modern silicone implants is not currently recognized. In a prospective controlled study, C-reactive protein and other variables were monitored, aiming to test this hypothesis in a young cohort of patients. Females (18-30 years old, BMI = 18.5-30 kg/m(2), N = 52) were consecutively recruited for breast implant (n = 24, Group I) and for abdominal liposuction (n = 28, Group II/Controls). Patients were interviewed at baseline and followed until 6 months after operation. Variables included demographic and clinical information, surgical outcome, inflammatory markers and autoantibodies. Operations were well tolerated, without surgical or infectious complications. Mean prosthesis size was 258 +/- A 21 ml (range = 220-280) and mean aspirate of liposuction was 1972 +/- A 499 ml (range = 1200-3000). Preoperative, 2-month, and 6-month C-reactive protein concentrations for breast implant patients were 1.3 +/- A 1.2, 4.8 +/- A 3.0, and 4.3 +/- A 6.4 mg/l and for liposuction 3.5 +/- A 2.7, 3.5 +/- A 2.1, and 2.2 +/- A 2.2 mg/l, respectively. Change at 2 months was significant (p = 0.001). Autoantibody investigation failed to reveal remarkable aberrations, except for anticardiolipin elevation, which was nearly symmetrical in the two groups. C-reactive protein levels increased after operation and correlated with proinflammatory and procoagulatory indices. A mild increase in anticardiolipin IgM occurred but differences between populations were lacking. Despite excellent cosmetic outcomes and lack of complications, acute phase reaction could signal ongoing immunogenicity of silicone and long-term monitoring is recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although surgical techniques and the quality of mammary prostheses have been improved significantly in recent years, capsular contracture attendant on prosthetic mammary reconstruction remains a major flaw. Although rarely, some patients are confronted with recurrent and intractable capsular contractures with resultant breast deformity, even after multiple attempts at capsulectomies and implant exchange. Patients with recurrent capsular contracture often do not want replacement with a new prosthesis, but desire the maintenance of their breast volume with a safe alternative. In an attempt to maintain breast volume and to improve the aesthetic appearance, secondary breast reconstruction using bilateral deepithelialized free flaps from the lower abdomen was performed in a series of seven patients. Three bilateral muscle-sparing TRAM flaps, two bilateral DIEP flaps, one bilateral SIEA flap, one unilateral SIEA flap, and one unilateral DIEP flap (a total number of 14 flaps) were used following implant removal, total capsulectomy, and prophylactic subcutaneous mastectomy. The early postoperative course was uneventful, and all flaps survived completely with no complications. There were no donor-site problems, except in one patient (case 5), who had partial skin necrosis of the abdominal flap. The long-term results (mean follow-up: 4.8 years) demonstrated an aesthetically satisfactory appearance of the breasts, with no major donor-site problems. Several advantages, as well as drawbacks, are highlighted with this technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last years there has been a growing demand of plastic surgery for soft tissue reconstruction. In response to this, many biological and synthetic devices have been produced, aiming to allow wide and complex body reshapings. Acellular dermal matrices are one of these devices, and are made of human or animal tissues made acellular after their sampling. They are used for cervical, breast and abdominal wall reconstruction. Tutopatch®, generally used for face reconstruction or neurosurgery, is made of acellular bovine pericardium, and its high amount of collagen allows a fast tissue healing and a scaffold for the surrounding tissue rigeneration. In our case report Tutopatch® has been used in immediate breast reconstruction after mastectomy. This device has been used to close laterally the subpectoral pocket, allowing a bigger volume prosthesis to be placed We have not experienced particular postoperatory complications, and after 12 months of follow up we have found a valid functional and aesthetic result. We consider Tutopatch® as a valid alternative to other acellular dermal matrices specifically designed for breast reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background There is evidence that certain mutations in the double-strand break repair pathway ataxia-telangiectasia mutated gene act in a dominant-negative manner to increase the risk of breast cancer. There are also some reports to suggest that the amino acid substitution variants T2119C Ser707Pro and C3161G Pro1054Arg may be associated with breast cancer risk. We investigate the breast cancer risk associated with these two nonconservative amino acid substitution variants using a large Australian population-based case–control study. Methods The polymorphisms were genotyped in more than 1300 cases and 600 controls using 5' exonuclease assays. Case–control analyses and genotype distributions were compared by logistic regression. Results The 2119C variant was rare, occurring at frequencies of 1.4 and 1.3% in cases and controls, respectively (P = 0.8). There was no difference in genotype distribution between cases and controls (P = 0.8), and the TC genotype was not associated with increased risk of breast cancer (adjusted odds ratio = 1.08, 95% confidence interval = 0.59–1.97, P = 0.8). Similarly, the 3161G variant was no more common in cases than in controls (2.9% versus 2.2%, P = 0.2), there was no difference in genotype distribution between cases and controls (P = 0.1), and the CG genotype was not associated with an increased risk of breast cancer (adjusted odds ratio = 1.30, 95% confidence interval = 0.85–1.98, P = 0.2). This lack of evidence for an association persisted within groups defined by the family history of breast cancer or by age. Conclusion The 2119C and 3161G amino acid substitution variants are not associated with moderate or high risks of breast cancer in Australian women.