959 resultados para bone cortical
Resumo:
NeuropeptideY-, Y2 receptor (Y2)-, and leptin-deficient mice show similar anabolic action in cancellous bone but have not been assessed in cortical bone. Cortical bone mass is elevated in Y2(-/-) mice through greater osteoblast activity. In contrast, leptin deficiency results in reduced bone mass. We show opposing central regulation of cortical bone.
Resumo:
Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.
Resumo:
There are two main types of bone in the human body, trabecular and cortical bone. Cortical bone is primarily found on the outer surface of most bones in the body while trabecular bone is found in vertebrae and at the end of long bones (Ross 2007). Osteoporosis is a condition that compromises the structural integrity of trabecular bone, greatly reducing the ability of the bone to absorb energy from falls. The current method for diagnosing osteoporosis and predicting fracture risk is measurement of bone mineral density. Limitations of this method include dependence on the bone density measurement device and dependence on type of test and measurement location (Rubin 2005). Each year there are approximately 250,000 hip fractures in the United States due to osteoporosis (Kleerekoper 2006). Currently, the most common method for repairing a hip fracture is a hip fixation surgery. During surgery, a temporary guide wire is inserted to guide the permanent screw into place and then removed. It is believed that directly measuring this screw pullout force may result in a better assessment of bone quality than current indirect measurement techniques (T. Bowen 2008-2010, pers. comm.). The objective of this project is to design a device that can measure the force required to extract this guide wire. It is believed that this would give the surgeon a direct, quantitative measurement of bone quality at the site of the fixation. A first generation device was designed by a Bucknell Biomedical Engineering Senior Design team during the 2008- 2009 Academic Year. The first step of this project was to examine the device, conduct a thorough design analysis, and brainstorm new concepts. The concept selected uses a translational screw to extract the guide wire. The device was fabricated and underwent validation testing to ensure that the device was functional and met the required engineering specifications. Two tests were conducted, one to test the functionality of the device by testing if the device gave repeatable results, and the other to test the sensitivity of the device to misalignment. Guide wires were extracted from 3 materials, low density polyethylene, ultra high molecular weight polyethylene, and polypropylene and the force of extraction was measured. During testing, it was discovered that the spring in the device did not have a high enough spring constant to reach the high forces necessary for extracting the wires without excessive deflection of the spring. The test procedure was modified slightly so the wires were not fully threaded into the material. The testing results indicate that there is significant variation in the screw pullout force, up to 30% of the average value. This significant variation was attributed to problems in the testing and data collection, and a revised set of tests was proposed to better evaluate the performance of the device. The fabricated device is a fully-functioning prototype and further refinements and testing of the device may lead to a 3rd generation version capable of measuring the screw pullout force during hip fixation surgery.
Resumo:
Despite the fact that bone mineral density (BMD) is an important fracture risk predictor in human medicine, studies in equine orthopedic research are still lacking. We hypothesized that BMD correlates with bone failure and fatigue fractures of this bone. Thus, the objectives of this study were to measure the structural and mechanical properties of the proximal phalanx with dual energy X-ray absorptiometry (DXA), to correlate the data obtained from DXA and computer tomography (CT) measurements to those obtained by loading pressure examination and to establish representative region of interest (ROI) for in vitro BMD measurements of the equine proximal phalanx for predicting bone failure force. DXA was used to measure the whole bone BMD and additional three ROI sites in 14 equine proximal phalanges. Following evaluation of the bone density, whole bone, cortical width and area in the mid-diaphyseal plane were measured on CT images. Bones were broken using a manually controlled universal bone crusher to measure bone failure force and reevaluated for the site of fractures on follow-up CT images. Compressive load was applied at a constant displacement rate of 2 mm/min until failure, defined as the first clear drop in the load measurement. The lowest BMD was measured at the trabecular region (mean +/- SD: 1.52 +/- 0.12 g/cm2; median: 1.48 g/cm2; range: 1.38-1.83 g/cm2). There was a significant positive linear correlation between trabelcular BMD and the breaking strength (P = 0.023, r = 0.62). The trabecular region of the proximal phalanx appears to be the only significant indicator of failure of strength in vitro. This finding should be reassessed to further reveal the prognostic value of trabecular BMD in an in vivo fracture risk model.
Histologia da associação de membranas biológicas de origem bovina implantadas no subcutâneo de ratos
Resumo:
O trabalho teve por objetivo avaliar a capacidade de barreira da membrana de cortical óssea desmineralizada liofilizada bovina, testando sua permeabilidade e integridade, em associação com a membrana de pericárdio bovino liofilizado. em 15 ratos Wistar, machos, adultos, implantou-se no subcutâneo da região cérvico-torácica dorsal a combinação de duas membranas de cortical óssea desmineralizada tendo no interior a membrana de pericárdio bovino. Os animais (cinco ratos/grupo) foram submetidos à eutanásia aos 15, 30 e 60 dias de pós-operatório. A avaliação microscópica mostrou que, aos 15 dias de pós-cirúrgico, as membranas estavam íntegras, com exceção de pequenas áreas de reabsorção da membrana de cortical óssea junto aos locais referentes aos antigos canais nutritivos. Aos 30 dias, havia apenas restos da membrana de cortical óssea e, aos 60 dias, a sua total ausência. Baseados nos resultados aqui obtidos, é possível concluir que a membrana de cortical óssea bovina é rapidamente absorvida e não confere proteção à membrana de pericárdio bovino liofilizado.
Resumo:
Considering that alcohol has been identified, in the literature, as an evident risk factor for osteoporosis development, inducing loss of bone mass, the aim of this study was to evaluate the effect of the alcohol on the femur of male and female rats. For this purpose, 35 male and 35 female rats, divided into seven groups of five animals per genera were included. The groups were: control group that received food and water as much as they wished; alcohol group in the concentrations of 10, 20 and 30% and the isocalorie: groups corresponding to the concentration of alcohol. After 8 weeks, the animals were sacrificed and evaluated regarding to the body weight and nutritional conditions. Unilateral femurs were removed and analyzed in relation to the length, width, and thickness of the bone cortical, trabeculae percentage and optical density. Data obtained were analyzed by ANOVA (Tukey; p<0.05). Regarding to the weight, loss of weight was observed in the animals of the group alcohol 20% among females and 30% among the males. In relation to the nutritional conditions, the females with the dosages of 10, 20 and 30% of alcohol swallowed a mean of 25, 39 and 53% of Kcall and the males 22, 36 and 45 Kcal Jday coming from the alcohol. Alcohol reduced the length of the femur only in the group MG6. Mesio-distal width was higher in the group FG6 although the antero-posterior width was not modified. The cortical thickness among males and females was not altered however the percentage of trabeculae bone was reduced among females alcohol 30% and among males with the three alcoholic concentrations. Optical density was reduced in the concentration of 30% among the males and females. Under the experimental conditions, it could be concluded that the effect of alcohol was more evident among the males and in the trabeculae bone, and that the alcoholic concentration of 30% was the most harmful for the bone tissue, ....
Resumo:
The follow up after endodontic treatment is the most effective tool for evaluating the quality of treatments performed, as well as, it lets to examine the procedures used at different stages of endodontic therapy. Clinical and radiographic findings must be taken into consideration to determine the percentage of endodontic success. Clinical findings include: absence of pain or positive examinations for percussion and palpation, swelling, tooth mobility and fistula. Regarding the radiographic findings it is possible to report absence of periapical radiolucent areas suggestive of periapical lesions and presence of bone cortical. Thus the aim of this study was to perform a bibliographic revision and a discussion about the factors of endodontic treatment follow up.
Resumo:
Aim: To investigate the effect of implant-abutment angulation and crown material on stress distribution of central incisors. Finite element method was used to simulate the clinical situation of a maxillary right central incisor restored by two different implant-abutment angulations, 15° and 25°, using two different crown materials (IPS E-Max CAD and zirconia). Methods: Two 3D finite element models were specially prepared for this research simulating the abutment angulations. Commercial engineering CAD/CAM package was used to model crown, implant abutment complex and bone (cortical and spongy) in 3D. Linear static analysis was performed by applying a 178 N oblique load. The obtained results were compared with former experimental results. Results: Implant Von Mises stress level was negligibly changed with increasing abutment angulation. The abutment with higher angulation is mechanically weaker and expected to fail at lower loading in comparison with the steeper one. Similarly, screw used with abutment angulation of 25° will fail at lower (about one-third) load value the failure load of similar screw used with abutment angulated by 15°. Conclusions: Bone (cortical and spongy) is insensitive to crown material. Increasing abutment angulation from 15° to 25°, increases stress on cortical bone by about 20% and reduces it by about 12% on spongy bone. Crown fracture resistance is dramatically reduced by increasing abutment angulation. Zirconia crown showed better performance than E-Max one.
Resumo:
The aim of this study was to evaluate risk factors for low bone mineral density (BMD) and vertebral fractures, in juvenile systemic lupus (JSLE). Thirty-one consecutive patients with JSLE were compared with 31 gender- and age-matched healthy controls. BNID and body composition from all participants were measured using dual-energy X-ray absorptiometry. Vertebral fractures were defined as a reduction of >= 20% of the vertebral height for all patients. Lumbar spine and total femur BMD was significantly decreased in patients compared with controls (P = 0.021 and P = 0.023, respectively). A high frequency of vertebral fractures (22.58%) was found in patients with JSLE. Analysis of body composition revealed lower lean mass (P = 0.033) and higher fat mass percentage (P = 0.003) in patients than in controls. Interestingly, multiple linear regression using BMD as a dependent variable showed a significant association with lean mass in lumbar spine (R(2) = 0.262; P = 0.004) and total femur (R(2) = 0.419, P = 0.0001), whereas no association was observed with menarche age, SLE Disease Activity Index, Systemic Lupus International Collaborating Clinics/American College of Rheumatology, and glucocorticoid. This study indicates that low BMD and vertebral fractures are common in JSLE, and the former is associated with low lean mass, suggesting that muscle rehabilitation may be an additional target for bone therapeutic approach.
Resumo:
A role for gut hormone in bone physiology has been suspected. We evidenced alterations of microstructural morphology (trabecular and cortical) and bone strength (both at the whole-bone - and tissue-level) in double incretin receptor knock-out (DIRKO) mice as compared to wild-type littermates. These results support a role for gut hormones in bone physiology. INTRODUCTION: The two incretins, glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide-1 (GLP-1), have been shown to control bone remodeling and strength. However, lessons from single incretin receptor knock-out mice highlighted a compensatory mechanism induced by elevated sensitivity to the other gut hormone. As such, it is unclear whether the bone alterations observed in GIP or GLP-1 receptor deficient animals resulted from the lack of a functional gut hormone receptor, or by higher sensitivity for the other gut hormone. The aims of the present study were to investigate the bone microstructural morphology, as well as bone tissue properties, in double incretin receptor knock-out (DIRKO) mice. METHODS: Twenty-six-week-old DIRKO mice were age- and sex-matched with wild-type (WT) littermates. Bone microstructural morphology was assessed at the femur by microCT and quantitative X-ray imaging, while tissue properties were investigated by quantitative backscattered electron imaging and Fourier-transformed infrared microscopy. Bone mechanical response was assessed at the whole-bone- and tissue-level by 3-point bending and nanoindentation, respectively. RESULTS: As compared to WT animals, DIRKO mice presented significant augmentations in trabecular bone mass and trabecular number whereas bone outer diameter, cortical thickness, and cortical area were reduced. At the whole-bone-level, yield stress, ultimate stress, and post-yield work to fracture were significantly reduced in DIRKO animals. At the tissue-level, only collagen maturity was reduced by 9 % in DIRKO mice leading to reductions in maximum load, hardness, and dissipated energy. CONCLUSIONS: This study demonstrated the critical role of gut hormones in controlling bone microstructural morphology and tissue properties.
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes