816 resultados para blood cardioplegia
Resumo:
OBJECTIVE: Contact of blood with artificial surfaces and air as well as ischemia/reperfusion injury to the heart and lungs mediate systemic and local inflammation during cardiopulmonary bypass (CPB). Activation of complement and coagulation cascades leads to and accompanies endothelial cell damage. Therefore, endothelial-targeted cytoprotection with the complement inhibitor and endothelial protectant dextran sulfate (DXS, MW 5000) may attenuate CBP-associated myocardial and pulmonary injury. METHODS: Eighteen pigs (DXS, n=10; phosphate buffered saline [PBS], n=8) underwent standard cardiopulmonary bypass. After aortic cross-clamping, cardiac arrest was initiated with modified Buckberg blood cardioplegia (BCP), repeated after 30 and 60 min with BCP containing either DXS (300 mg/10 ml, equivalent to 5mg/kg) or 10 ml of PBS. Following 30 min reperfusion, pigs were weaned from CPB. During 2h of observation, cardiac function was monitored by echocardiography and invasive pressure measurements. Inflammatory and coagulation markers were assessed regularly. Animals were then sacrificed and heart and lungs analyzed. RESULTS: DXS significantly reduced CK-MB levels (43.4+/-14.8 ng/ml PBS, 35.9+/-11.1 ng/ml DXS, p=0.042) and significantly diminished cytokine release: TNFalpha (1507.6+/-269.2 pg/ml PBS, 222.1+/-125.6 pg/ml DXS, p=0.0071), IL1beta (1081.8+/-203.0 pg/ml PBS, 110.7+/-79.4 pg/ml DXS, p=0.0071), IL-6 (173.0+/-91.5 pg/ml PBS, 40.8+/-19.4 pg/ml DXS, p=0.002) and IL-8 (304.6+/-81.3 pg/ml PBS, 25.4+/-14.2 pg/ml DXS, p=0.0071). Tissue endothelin-1 levels were significantly reduced (6.29+/-1.90 pg/100mg PBS, 3.55+/-1.15 pg/100mg DXS p=0.030) as well as thrombin-anti-thrombin formation (20.7+/-1.0 microg/ml PBS, 12.8+/-4.1 microg/ml DXS, p=0.043). Also DXS reduced cardiac and pulmonary complement deposition, neutrophil infiltration, hemorrhage and pulmonary edema (measured as lung water content, 81+/-3% vs 78+/-3%, p=0.047), indicative of attenuated myocardial and pulmonary CPB-injury. Diastolic left ventricular function (measured as dp/dt(min)), pulmonary artery pressure (21+/-3 mmHg PBS, 19+/-3 mmHg DXS, p=0.002) and right ventricular pressure (21+/-1 mmHg PBS, 19+/-3 mmHg DXS p=0.021) were significantly improved with the use of DXS. CONCLUSIONS: Addition of DXS to the BCP solution ameliorates post-CPB injury and to a certain extent improves cardiopulmonary function. Endothelial protection in addition to myocyte protection may improve post-CPB outcome and recovery.
Resumo:
OBJETIVO: Estudar a eficácia e a segurança da cardioplegia sanguínea, aterógrada-retrógrada contínua, por meio da avaliação da função ventricular. MÉTODOS: Os coelhos foram divididos em quatro grupos: Controle-C(n=10); isquêmico e cardioplegia cristaloide-IC(n=10; isquêmico e cardioplegia sanguínea-IB(n=10; isquêmico sem cardioplegia-INC(n=10. Após o período isquêmico do protocolo a função ventricular foi analisada pela técnica do balão intra-ventricular. RESULTADOS: a pressão desenvolvida intra-ventricular (IVDP) foi: C(92,90± 6,86mmHg); IC(77,78± 6,15mmHg); IB(93,64 ±5,09mmHg); INC(39,46 ±8,91mmHg) p<0,005. a primeira derivada temporal da pressão ventricular na sua deflexão positiva: C(1137,50± 92,23mmHg/sec); IC(1130,62 ±43,78mmHg/sec); IB(1187,58± 88,38mmHg/sec); INC(620,02± 43,80mmHg/se) p<0,005. A primeira derivada da pressão ventricular na sua deflexão negativa: C(770,00± 73,41mmHg/sec); IC(610,03 ±47,43mmg/sec); IB(762,53 ±46,02mmHg/sec); INC(412,35 ±84,36mmHg/sec) p<0,005. A relação do coeficiente angular logarítmico foi: C(0,108± 0,02); IC(0,159± 0,038); IB(0,114 ±0,016); INC(0,175± 0,038) p<0,05. CONCLUSÃO: No modelo experimental estudado o grupo isquêmico protegido pela cardioplegia sanguínea apresentou melhor função ventricular que os grupos protegidos por cardioplegia cristalóide e não protegido.
Resumo:
The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber, and bellows type. The evaluation was performed by in vitro tests of parameters such as heat transfer, pressure drop, and hemolysis tendency. The result has shown that all four systems tested were able to achieve the heat performance, and to offer low resistance to flow, and safety, as well as have low tendency to hemolysis. However, we can emphasize that the bellows type heat exchanger has a significant difference with regard to the other three types.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
INTRODUCTION : L’utilisation de la circulation extracorporelle durant la chirurgie cardiaque est associée à des problèmes pulmonaires chez certains patients. L’utilisation d’une pression pulsatile induite par un ballon intra-aortique (BIA) pourrait diminuer la dysfonction endothéliale et la survenue de tels événements. MATÉRIEL ET MÉTHODE : 12 porcs Landrace-Yorkshire ont subi une circulation extracorporelle et ont été divisés en deux groupes et 4 porcs ont servi de contrôles sans CEC. Le premier groupe (n=6) a bénéficié d’un flot pulsatile créé par un BIA en mode interne à 80 battements par minute durant les 90 minutes de l’opération alors que le second groupe (n=6) a subi une CEC standard. Après 60 minutes de reperfusion suivant la CEC, les valeurs hémodynamiques ont été évaluées dont les pressions artérielles, les pressions pulmonaires, l’index cardiaque et la concentration de glucose et de lactate. Les artères pulmonaires sont ensuite montées en chambre d’organe pour évaluer la fonction endothéliale. RÉSULTATS : Les porcs avec pression pulsatile ont tendance à produire moins de lactate sanguin après 60 minutes de reperfusion. Les autres valeurs hémodynamiques sont semblables. Finalement, la relaxation à la bradykinine est significativement meilleure dans le groupe pression pulsatile alors que la relaxation à l’acétylcholine n’est pas significativement différente. CONCLUSION : Ces résultats démontrent que la perfusion pulsatile produite par un BIA protège l’endothélium pulmonaire lors d'une CEC. Cet effet pourrait être dû à une augmentation du flot bronchique qui diminuerait l’ischémie pulmonaire ou à une diminution de la libération de cytokines et de bradykinine qui réduirait les dommages de reperfusion.
Acute hyponatremia after cardioplegia by histidine-tryptophane-ketoglutarate - a retrospective study
Resumo:
Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.