22 resultados para bioaerosol


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limited research has been conducted on the collection of bioaerosols and their health effects on individuals in the El Paso area. A year long study was conducted in the region to evaluate indoor bioaerosol concentrations (Mota et al., unpublished data). As part of the study, air samples were collected during each season for a year from 38 homes from the El Paso area. The main objective of the study was to assess seasonality differences in bioaerosol concentrations. The air samples were then cultured and analyzed for bacterial and fungal concentrations. As a supplement to that study, a health questionnaire was given during each seasonal air sampling to the participating resident to complete regarding their health status. The aim of this study was to evaluate the health questionnaire and assess any associations between the collected bioaerosol concentrations and the self-reported respiratory symptoms of the participating home residents. Symptom frequencies were tabulated and basic descriptive statistics, along with logistic regressions, were conducted on the relationship between “High” reporters of symptoms and bioaerosol concentrations and environmental factors. The most commonly reported symptoms by homeowners were nasal symptoms and allergies. In addition, there was evidence to support an association between indoor respirable bacteria concentrations and homeowners that report greater than or equal to 8 respiratory symptoms (OR=1.10, p=0.045). Smoking status, indoor humidity and season also displayed associations with homeowners that report greater than or equal to 8 respiratory symptoms (OR=3.3, p=0.045; OR=71.0, p=0.030; OR=7.2, 3.2, p=0.001, 0.008). With such a strong association, future assessment of symptoms, bioaerosol concentrations and environmental factors is needed to further establish their relationship. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concern regarding the health effects of indoor air quality has grown in recent years, due to the increased prevalence of many diseases, as well as the fact that many people now spend most of their time indoors. While numerous studies have reported on the dynamics of aerosols indoors, the dynamics of bioaerosols in indoor environments are still poorly understood and very few studies have focused on fungal spore dynamics in indoor environments. Consequently, this work investigated the dynamics of fungal spores in indoor air, including fungal spore release and deposition, as well as investigating the mechanisms involved in the fungal spore fragmentation process. In relation to the investigation of fungal spore dynamics, it was found that the deposition rates of the bioaerosols (fungal propagules) were in the same range as the deposition rates of nonbiological particles and that they were a function of their aerodynamic diameters. It was also found that fungal particle deposition rates increased with increasing ventilation rates. These results (which are reported for the first time) are important for developing an understanding of the dynamics of fungal spores in the air. In relation to the process of fungal spore fragmentation, important information was generated concerning the airborne dynamics of the spores, as well as the part/s of the fungi which undergo fragmentation. The results obtained from these investigations into the dynamics of fungal propagules in indoor air significantly advance knowledge about the fate of fungal propagules in indoor air, as well as their deposition in the respiratory tract. The need to develop an advanced, real-time method for monitoring bioaerosols has become increasingly important in recent years, particularly as a result of the increased threat from biological weapons and bioterrorism. However, to date, the Ultraviolet Aerodynamic Particle Sizer (UVAPS, Model 3312, TSI, St Paul, MN) is the only commercially available instrument capable of monitoring and measuring viable airborne micro-organisms in real-time. Therefore (for the first time), this work also investigated the ability of the UVAPS to measure and characterise fungal spores in indoor air. The UVAPS was found to be sufficiently sensitive for detecting and measuring fungal propagules. Based on fungal spore size distributions, together with fluorescent percentages and intensities, it was also found to be capable of discriminating between two fungal spore species, under controlled laboratory conditions. In the field, however, it would not be possible to use the UVAPS to differentiate between different fungal spore species because the different micro-organisms present in the air may not only vary in age, but may have also been subjected to different environmental conditions. In addition, while the real-time UVAPS was found to be a good tool for the investigation of fungal particles under controlled conditions, it was not found to be selective for bioaerosols only (as per design specifications). In conclusion, the UVAPS is not recommended for use in the direct measurement of airborne viable bioaerosols in the field, including fungal particles, and further investigations into the nature of the micro-organisms, the UVAPS itself and/or its use in conjunction with other conventional biosamplers, are necessary in order to obtain more realistic results. Overall, the results obtained from this work on airborne fungal particle dynamics will contribute towards improving the detection capabilities of the UVAPS, so that it is capable of selectively monitoring and measuring bioaerosols, for which it was originally designed. This work will assist in finding and/or improving other technologies capable of the real-time monitoring of bioaerosols. The knowledge obtained from this work will also be of benefit in various other bioaerosol applications, such as understanding the transport of bioaerosols indoors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vacuum cleaners can release large concentrations of particles, both in their exhaust air and from resuspension of settled dust. However, the size, variability and microbial diversity of these emissions are unknown, despite evidence to suggest they may contribute to allergic responses and infection transmission indoors. This study aimed to evaluate bioaerosol emission from various vacuum cleaners. We sampled the air in an experimental flow tunnel where vacuum cleaners were run and their airborne emissions sampled with closed-face cassettes. Dust samples were also 35 collected from the dust bag. Total bacteria, total archaea, Penicillium/Aspergillus and total Clostridium cluster 1 were quantified with specific qPCR protocols and emission rates were calculated. Clostridium botulinum, as well as antibiotic resistance genes were detected in each sample using endpoint PCR. Bacterial diversity was also analyzed using denaturing gel electrophoresis (DGGE), image analysis and band sequencing. We demonstrated that emission of bacteria and moulds (Pen/Asp) can reach values as high as 1E05/min and that those emissions are not related to each other. The bag dust bacterial and mould content was also consistently across the vacuums we assessed, reaching up to 1E07 bacteria or moulds equivalent/g. Antibiotic resistance genes were detected in several samples. No archaea or C. botulinum were detected in any air samples. Diversity analyses showed that most bacteria are from human sources, in keeping with other recent results. These results highlight the potential capability of vacuum cleaners to disseminate appreciable quantities of moulds and human-associated bacteria indoors and their role as a source of exposure to bioaerosols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In January 2011, Brisbane, Australia, experienced a major river flooding event. We aimed to investigate its effects on air quality and assess the role of prompt cleaning activities in reducing the airborne exposure risk. A comprehensive, multi-parameter indoor and outdoor measurement campaign was conducted in 41 residential houses, 2 and 6 months after the flood. The median indoor air concentrations of supermicrometer particle number (PN), PM10, fungi and bacteria 2 months after the flood were comparable to those previously measured in Brisbane. These were 2.88 p cm-3, 15 µg m-3, 804 cfu m-3 and 177 cfu m-3 for flood-affected houses (AFH), and 2.74 p cm-3, 15 µg m-3, 547 cfu m-3 and 167 cfu m-3 for non-affected houses (NFH), respectively. The I/O (indoor/outdoor) ratios of these pollutants were 1.08, 1.38, 0.74 and 1.76 for AFH and 1.03, 1.32, 0.83 and 2.17 for NFH, respectively. The average of total elements (together with transition metals) in indoor dust was 2296 ± 1328 µg m-2 for AFH and 1454 ± 678 µg m-2 for NFH, respectively. In general, the differences between AFH and NFH were not statistically significant, implying the absence of a measureable effect on air quality from the flood. We postulate that this was due to the very swift and effective cleaning of the flooded houses by 60,000 volunteers. Among the various cleaning methods, the use of both detergent and bleach was the most efficient at controlling indoor bacteria. All cleaning methods were equally effective for indoor fungi. This study provides quantitative evidence of the significant impact of immediate post-flood cleaning on mitigating the effects of flooding on indoor bioaerosol contamination and other pollutants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project developed and assessed a standard operating procedure for monitoring microbiological aerosol levels and dispersal from Australian industrial composting facilities. Development occurred via seasonal monitoring of such operations with evaluation of optimal microbial indicator organisms, sampling and analysis logistics. The resultant procedure allows practical end-user assessment of compost-associated bioaerosol levels, and potential health risks to proximal residential populations encroaching on such composting facilities and on-site industrial operations personnel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tem havido uma preocupação crescente com a qualidade do ar interior (QAI) nas escolas em muitos países. Muitos estudos epidemiológicos têm encontrado diferenças regionais entre ambientes interiores. Apesar da elevada incidência de asma e rinite na população infantil, praticamente nada se sabia sobre a QAI em escolas portuguesas. A percepção dos problemas de QAI é crucial para avaliar os riscos para a saúde e rendimento dos estudantes, e para sugerir meios de reduzir a exposição a poluentes indesejáveis. Neste estudo procurou-se obter as concentrações de poluentes de interesse em estabelecimentos de ensino do 1º ciclo de Lisboa e Aveiro, estimar o estado atual de casos de asma e rinite em escolas primárias da capital, avaliar a influência de diferentes materiais das salas de aula/construção e hábitos escolares na QAI, identificar potenciais fontes de poluentes nos interiores e exteriores das salas de aula e propor medidas mitigadoras. Catorze escolas de Lisboa foram visitadas para obter a caracterização física das construções em termos de estrutura, ventilação, materiais de acabamento, produtos de limpeza, densidade de ocupação e potenciais fontes interiores de poluição. Os estudantes foram questionados sobre os seus hábitos e sintomas respiratórios através de inquéritos do modelo ISAAC (International Study of Asthma and Allergies in Childhood). Durante a primavera, outono e inverno (2008-2010), nas salas de aula e pátios, foram monitorizados, por amostragem passiva, compostos orgânicos voláteis (COVs), carbonilos e dióxido de azoto (NO2). Foram também medidos parâmetros de conforto e níveis de microrganismos. Duas escolas localizadas, uma no centro da cidade e outra na região suburbana, em Aveiro foram estudadas em 2010. Parâmetros de conforto, microrganismos, COVs, NO2, material particulado (PM10) foram medidos no interior e no exterior de ambas escolas. Os iões solúveis, carbono orgânico e elementar (OC e EC), e compostos orgânicos presentes no material particulado foram subsequentemente analisados em laboratório. Uma medida mitigadora - fitoremediação - foi avaliada na escola do centro da cidade de Aveiro em 2011. Os resultados do estudo mostraram que a QAI é pior do que a do ar exterior. Em geral, os níveis de CO2 e dos bioaerosóis excederam os níveis máximos aceitáveis para o conforto dos ocupantes estipulado pelas regulamentações portuguesas. Quase todos os COVs e carbonilos identificados mostraram razões interior/exterior (I/E) maiores que uma unidade, o que demonstra a importante contribuição de fontes interiores em todas as escolas. As razões I/E das concentrações de NO2 nunca excederam a unidade. Os níveis interiores diários de PM10 foram sempre maiores que os exteriores, exceto nos fins de semana. Após a colocação de plantas numa das salas de aula, observou-se uma redução estatisticamente significativa nos níveis de CO2, COVs, carbonilos, PM10, OC, e dos iões nitrato, sulfato, amónia, cálcio e carbonato. A possível redução dos níveis de poluentes no interior após a colocação de plantas pode representar uma solução de baixo custo para reduzir a exposição a muitos compostos, melhorar o rendimento e aumentar o bem estar dos alunos e professores em sala de aula.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose here the hypothesis that all of United Kingdom (UK) is likely to be affected by Ganoderma sp. spores, an important plant pathogen. We suggest that the main sources of this pathogen, which acts as a bioaerosol, are the widely scattered woodlands in the country, although remote sources must not be neglected. The hypothesis is based on related studies on bioaerosols and supported by new observations from a non-forest site and model calculations to support our hypothesis. Hourly concentrations of Ganoderma sp. spores were measured from 2006 to 2010 using a 7-day volumetric spore trap at the city of Worcester. The concentrations peak during the night and early in the morning. This suggests that the main spore sources are located a few hours away with respect to air masses transport and reach urban areas thanks to air masses transport. The back-trajectory analysis was applied to determine the location of Ganoderma sp. spore sources. The analysis of back-trajectories demonstrated that 78% of the air masses reached Worcester from a 180° arc direction from the East to West. Three episodes were selected for detailed investigation and they revealed that during the episodes air masses always passed main UK woodlands before the arrival in Worcester, independently of their origin, but the long distance transport under certain conditions might be possible. Our studies suggest that the sources of UK Ganoderma sp. spores are mainly to be found in UK. Hence our studies suggest that research and mitigation strategies in UK should give their main attention to national sources, without neglecting the contribution from long distance transport.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An assessment of sewage workers' exposure to airborne cultivable bacteria, fungi and inhaled endotoxins was performed at 11 sewage treatment plants. We sampled the enclosed and unenclosed treatment areas in each plant and evaluated the influence of seasons (summer and winter) on bioaerosol levels. We also measured personal exposure to endotoxins of workers during special operation where a higher risk of bioaerosol inhalation was assumed. Results show that only fungi are present in significantly higher concentrations in summer than in winter (2331 +/- 858 versus 329 +/- 95 CFU m(-3)). We also found that there are significantly more bacteria in the enclosed area, near the particle grids for incoming water, than in the unenclosed area near the aeration basins (9455 +/- 2661 versus 2435 +/- 985 CFU m(-3) in summer and 11 081 +/- 2299 versus 2002 +/- 839 CFU m(-3) in winter). All bioaerosols were frequently above the recommended values of occupational exposure. Workers carrying out special tasks such as cleaning tanks were exposed to very high levels of endotoxins (up to 500 EU m(-3)) compared to routine work. The species composition and concentration of airborne Gram-negative bacteria were also studied. A broad spectrum of different species within the Pseudomonadaceae and the Enterobacteriaceae families were predominant in nearly all plants investigated. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From September 2000 to January 2001, airborne fungi were isolated from the building of the Clinical Analyses laboratories, including its didactic and research rooms, in Araraquara São Paulo State, Brazil, by using Andersen, MAS-100® (MERCK) machine, with Sabouraud chloramphenicol medium. After 5 days of incubation at 25°C, the colonies of the fungi were counted, resulting in the identification of 21 taxa. Cladophialophora spp. was the most isolated in internal and external environments as well, followed by Penicillium spp. and Mycelia spp. In accordance with the resolution n° 9, January 2003 (ANVISA), fungi considered unacceptable were found in nine internal environments and one of these presented the amount of fungi above of the acceptable limit. Among the obtained fungi, at least 16 taxa were reported as opportunistic, nine were related to plant diseases and seven were associated to allergy problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of masks is generally accepted as a means of protecting the individual against microbial pathogens that might be inhaled in unhealthy environments. The objective of this study was to evaluate the efficiency of disposable surgical masks sold in Brazil, against coliforms in aerosols emitted by the aerators of a sanitary sewage treatment station. The filtration efficiency varied from 50.9% to 99.9% for 6 masks from different sources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary biogenic aerosol (PBA) particles account for large proportions of air particulate matter, and they can influence the hydrological cycle and climate as nuclei for water droplets and ice crystals in clouds, fog, and precipitation. Moreover, they can cause or enhance human, animal, and plant diseases. The actual abundance and properties of PBA particles and components in the atmosphere are, however, still poorly understood and quantified. rnIn this study, the identity, diversity, and frequency of occurrence of PBA particles were investigated by DNA analysis. Methods for the extraction, amplification, and analysis of DNA from aerosol filter samples were developed and optimized for different types of organisms, including fungi, bacteria, and plants. The investigations were focused on fungal DNA, and over 2500 sequences were obtained from air samples collected at different locations and climatic zones around the world (tropical, mid-latitude, sub-polar; continental, marine). rnNearly all fungal DNA sequences could be attributed to the phyla of Ascomycota and Basidiomycota. With regard to species richness, the ratio of Basidiomycota to Ascomycota was much higher in continental air samples (~60:40) than in marine air samples (~30:70). Pronounced differences in the relative abundance and seasonal cycles of various groups of fungi were detected in coarse and fine particulate matter from continental air, with more plant pathogens in the coarse and more human pathogens and allergens in the respirable fine particle fraction (<3 µm). The results of this study provide new information and insights into the sources of PBA particles and the interactions of the biosphere with the atmosphere, climate, and public health. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aerosol particles are important actors in the Earth’s atmosphere and climate system. They scatter and absorb sunlight, serve as nuclei for water droplets and ice crystals in clouds and precipitation, and are a subject of concern for public health. Atmospheric aerosols originate from both natural and anthropogenic sources, and emissions resulting from human activities have the potential to influence the hydrological cycle and climate. An assessment of the extent and impacts of this human force requires a sound understanding of the natural aerosol background. This dissertation addresses the composition, properties, and atmospheric cycling of biogenic aerosol particles, which represent a major fraction of the natural aerosol burden. The main focal points are: (i) Studies of the autofluo-rescence of primary biological aerosol particles (PBAP) and its application in ambient measure-ments, and (ii) X-ray microscopic and spectroscopic investigations of biogenic secondary organic aerosols (SOA) from the Amazonian rainforest.rnAutofluorescence of biological material has received increasing attention in atmospheric science because it allows real-time monitoring of PBAP in ambient air, however it is associated with high uncertainty. This work aims at reducing the uncertainty through a comprehensive characterization of the autofluorescence properties of relevant biological materials. Fluorescence spectroscopy and microscopy were applied to analyze the fluorescence signatures of pure biological fluorophores, potential non-biological interferences, and various types of reference PBAP. Characteristic features and fingerprint patterns were found and provide support for the operation, interpretation, and further development of PBAP autofluorescence measurements. Online fluorescence detection and offline fluorescence microscopy were jointly applied in a comprehensive bioaerosol field measurement campaign that provided unprecedented insights into PBAP-linked biosphere-atmosphere interactions in a North-American semi-arid forest environment. Rain showers were found to trigger massive bursts of PBAP, including high concentrations of biological ice nucleators that may promote further precipitation and can be regarded as part of a bioprecipitation feedback cycle in the climate system. rnIn the pristine tropical rainforest air of the Amazon, most cloud and fog droplets form on bio-genic SOA particles, but the composition, morphology, mixing state and origin of these particles is hardly known. X-ray microscopy and spectroscopy (STXM-NEXAFS) revealed distinctly different types of secondary organic matter (carboxyl- vs. hydroxy-rich) with internal structures that indicate a strong influence of phase segregation, cloud and fog processing on SOA formation, and aging. In addition, nanometer-sized potassium-rich particles emitted by microorganisms and vegetation were found to act as seeds for the condensation of SOA. Thus, the influence of forest biota on the atmospheric abundance of cloud condensation nuclei appears to be more direct than previously assumed. Overall, the results of this dissertation suggest that biogenic aerosols, clouds and precipitation are indeed tightly coupled through a bioprecipitation cycle, and that advanced microscopic and spectroscopic techniques can provide detailed insights into these mechanisms.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sick Building Syndrome is a prevalent problem with patient complaints similar to typical allergy symptoms. Unlike most household allergens, the Asp f 1 allergen is conceivably ubiquitous in the work environment. This project examined levels of the Asp f 1 allergen in office and non-industrial occupational environments, and studied the bioaerosol and dust reservoirs of Aspergillus fumigatus responsible for those levels. ^ Culturable bioaerosols of total mesophilic fungi were sampled with Andersen N6 impactors. Aggressive airborne and bulk dust samples were concurrently collected and assayed for Asp f 1. Bulk dusts were selectively cultured for A. fumigatus. Samples were collected during both wet and dry climatological conditions to examine the possibility of Asp f 1 increases due to fungal growth blooms. ^ Only very low levels of Asp f 1 were detected in relatively few samples. Analysis of wet versus dry period samples showed no differences in Asp f 1 levels, although A. fumigatus counts from dusts did fluctuate significantly with exterior moisture events as did indoor prevalence of total colony forming units. These results indicate that even in the presence of elevated fungal concentrations, levels of Asp f 1 are extremely low. These levels do not correlate with climatological moisture events, despite distinct fungal blooms in the days immediately following those events. Non-industrial office buildings devoid of indoor air quality issues did not demonstrate significant levels or occurrence of Asp f 1 contamination in the geographical region of this study. ^