Australian manufacturers recently developed a new mono-symmetric cold-formed steel hollow flange channel section known as LiteSteel Beam. The innovative LSB sections with rectangular flanges are currently being used as floor joists and bearers in buildings. In order to assess their behaviour and section moment capacity including the presence of any inelastic reserve bending capacity, 20 section moment capacity tests were conducted in this study. Test results were compared with the section moment capacities predicted by the steel design codes. Although the current cold-formed steel design rules generally limit the section moment capacities to their first yield moments, test results showed that inelastic reserve bending capacity was present in the compact and non-compact LSB sections. The results have shown that suitable modifications to the current design rules are needed to allow the inclusion of available inelastic bending capacities of LSBs in design.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The LiteSteel Beam (LSB) is a new cold-formed hollow flange channel section developed by OneSteel Australian Tube Mills using their patented dual electric resistance welding and automated continuous roll-forming process. It has a unique geometry consisting of torsionally rigid rectangular hollow flanges and a relatively slender web. In addition to this unique geometry, the LSB sections also have unique characteristics relating to their stress-strain curves, residual stresses, initial geometric imperfections and hollow flanges that are not encountered in conventional hot-rolled and cold-formed steel channel sections. An experimental study including 20 section moment capacity tests was therefore conducted to investigate the behaviour and strength of LSB flexural members. The presence of inelastic reserve bending capacity in these beams was investigated in detail although the current design rules generally limit the section moment capacities of cold-formed steel members to their first yield moments. The ultimate moment capacities from the tests were compared with the section moment capacities predicted by the current cold-formed and hot-rolled steel design standards. It was found that compact and non-compact LSB sections have greater moment capacities than their first yield moments. The current cold-formed steel design standards were found to be conservative in predicting the section moment capacities of compact and non-compact LSB sections while the hot-rolled steel design standards were able to better predict them. This paper has shown that suitable modifications are needed to the current design rules to allow the inclusion of available inelastic bending capacities of LSBs in design.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The LiteSteel Beam (LSB) is a new hollow flange channel section developed by OneSteel Australian Tube Mills using a patented Dual Electric Resistance Welding technique. The LSB has a unique geometry consisting of torsionally rigid rectangular hollow flanges and a relatively slender web. It is commonly used as rafters, floor joists and bearers and roof beams in residential, industrial and commercial buildings. It is on average 40% lighter than traditional hot-rolled steel beams of equivalent performance. The LSB flexural members are subjected to a relatively new Lateral Distortional Buckling mode, which reduces the member moment capacity. Unlike the commonly observed lateral torsional buckling of steel beams, lateral distortional buckling of LSBs is characterised by simultaneous lateral deflection, twist and web distortion. Current member moment capacity design rules for lateral distortional buckling in AS/NZS 4600 (SA, 2005) do not include the effect of section geometry of hollow flange beams although its effect is considered to be important. Therefore detailed experimental and finite element analyses (FEA) were carried out to investigate the lateral distortional buckling behaviour of LSBs including the effect of section geometry. The results showed that the current design rules in AS/NZS 4600 (SA, 2005) are over-conservative in the inelastic lateral buckling region. New improved design rules were therefore developed for LSBs based on both FEA and experimental results. A geometrical parameter (K) defined as the ratio of the flange torsional rigidity to the major axis flexural rigidity of the web (GJf/EIxweb) was identified as the critical parameter affecting the lateral distortional buckling of hollow flange beams. The effect of section geometry was then included in the new design rules using the new parameter (K). The new design rule developed by including this parameter was found to be accurate in calculating the member moment capacities of not only LSBs, but also other types of hollow flange steel beams such as Hollow Flange Beams (HFBs), Monosymmetric Hollow Flange Beams (MHFBs) and Rectangular Hollow Flange Beams (RHFBs). The inelastic reserve bending capacity of LSBs has not been investigated yet although the section moment capacity tests of LSBs in the past revealed that inelastic reserve bending capacity is present in LSBs. However, the Australian and American cold-formed steel design codes limit them to the first yield moment. Therefore both experimental and FEA were carried out to investigate the section moment capacity behaviour of LSBs. A comparison of the section moment capacity results from FEA, experiments and current cold-formed steel design codes showed that compact and non-compact LSB sections classified based on AS 4100 (SA, 1998) have some inelastic reserve capacity while slender LSBs do not have any inelastic reserve capacity beyond their first yield moment. It was found that Shifferaw and Schafer’s (2008) proposed equations and Eurocode 3 Part 1.3 (ECS, 2006) design equations can be used to include the inelastic bending capacities of compact and non-compact LSBs in design. As a simple design approach, the section moment capacity of compact LSB sections can be taken as 1.10 times their first yield moment while it is the first yield moment for non-compact sections. For slender LSB sections, current cold-formed steel codes can be used to predict their section moment capacities. It was believed that the use of transverse web stiffeners could improve the lateral distortional buckling moment capacities of LSBs. However, currently there are no design equations to predict the elastic lateral distortional buckling and member moment capacities of LSBs with web stiffeners under uniform moment conditions. Therefore, a detailed study was conducted using FEA to simulate both experimental and ideal conditions of LSB flexural members. It was shown that the use of 3 to 5 mm steel plate stiffeners welded or screwed to the inner faces of the top and bottom flanges of LSBs at third span points and supports provided an optimum web stiffener arrangement. Suitable design rules were developed to calculate the improved elastic buckling and ultimate moment capacities of LSBs with these optimum web stiffeners. A design rule using the geometrical parameter K was also developed to improve the accuracy of ultimate moment capacity predictions. This thesis presents the details and results of the experimental and numerical studies of the section and member moment capacities of LSBs conducted in this research. It includes the recommendations made regarding the accuracy of current design rules as well as the new design rules for lateral distortional buckling. The new design rules include the effects of section geometry of hollow flange steel beams. This thesis also developed a method of using web stiffeners to reduce the lateral distortional buckling effects, and associated design rules to calculate the improved moment capacities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes an experimental investigation of the behaviour of corroded reinforced concrete beams. These have been stored in a chloride environment for a period of 26 years under service loading so as to be representative of real structural and environmental conditions. The configuration and the widths of the cracks in the two seriously corroded short-span beams were depicted carefully, and then the beams were tested until failure by a three-point loading system. Another two beams of the same age but without corrosion were also tested as control specimens. A short span arrangement was chosen to investigate any effect of a reduction in the area and bond strength of the reinforcement on shear capacity. The relationship of load and deflection was recorded so as to better understand the mechanical behaviour of the corroded beams, together with the slip of the tensile bars. The corrosion maps and the loss of area of the tensile bars were also described after having extracted the corroded bars from the concrete beams. Tensile tests of the main longitudinal bars were also carried out. The residual mechanical behaviour of the beams is discussed in terms of the experimental results and the cracking maps. The results show that the corrosion of the reinforcement in the beams induced by chloride has a very important effect on the mechanical behaviour of the short-span beams, as loss of cross-sectional area and bond strength have a very significant effect on the bending capacity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El refuerzo de estructuras existentes mediante el encolado exterior de láminas de polímeros reforzados con fibras (FRP) se ha convertido en la aplicación más común de los materiales compuestos avanzados en construcción. Estos materiales presentan muchas ventajas frente a los materiales convencionales (sin corrosión, ligeros, de fácil aplicación, etc.). Pero a pesar de las numerosas investigaciones realizadas, aún persisten ciertas dudas sobre algunos aspectos de su comportamiento y las aplicaciones prácticas se llevan a cabo sólo con la ayuda de guías, sin que haya una normativa oficial. El objetivo de este trabajo es incrementar el conocimiento sobre esta técnica de refuerzo, y más concretamente, sobre el refuerzo a flexión de estructuras de fábrica. Con frecuencia el elemento reforzado es de hormigón armado y las láminas de FRP encoladas al exterior sirven para mejorar su resistencia a flexión, cortante o compresión (encamisados). Sin embargo su empleo en otros materiales como las estructuras de fábrica resulta muy prometedor. Las fábricas se caracterizan por soportar muy bien los esfuerzos de compresión pero bastante mal los de tracción. Adherir láminas de materiales compuestos puede servir para mejorar la capacidad resistente de elementos de fábrica sometidos a esfuerzos de flexión. Pero para ello, debe quedar garantizada una correcta adherencia entre el FRP y la fábrica, especialmente en edificios antiguos cuya superficie puede estar deteriorada por encontrarse a la intemperie o por el propio paso del tiempo. En el capítulo II se describen los objetivos fundamentales del trabajo y el método seguido. En el capítulo III se hace una amplia revisión del estado de conocimiento sobre el tema. En el apartado III.1 se detallan las principales características y propiedades mecánicas de fibras, matrices y materiales compuestos así como sus principales aplicaciones, haciendo especial hincapié en aspectos relativos a su durabilidad. En el apartado III.2 se incluye una revisión histórica de las líneas de investigación, tanto teóricas como empíricas, publicadas sobre estructuras de hormigón reforzadas a flexión encolando materiales compuestos. El apartado III.3 se centra en el aspecto fundamental de la adherencia refuerzo-soporte. Se hace un repaso a distintos modelos propuestos para prevenir el despegue distinguiendo si éste se inicia en la zona de anclaje o si está inducido por fisuras en la zona interior del elemento. Se observa falta de consenso en las propuestas. Además en este punto se relatan las campañas experimentales publicadas acerca de la adherencia entre materiales compuestos y fábricas. En el apartado III.4 se analizan las particularidades de las estructuras de fábrica. Además, se revisan algunas de las investigaciones relativas a la mejora de su comportamiento a flexión mediante láminas de FRP. El comportamiento mecánico de muros reforzados solicitados a flexión pura (sin compresión) ha sido documentado por varios autores, si bien es una situación poco frecuente en fábricas reales. Ni el comportamiento mecánico de muros reforzados solicitados a flexocompresión ni la incidencia que el nivel de compresión soportado por la fábrica tiene sobre la capacidad resistente del elemento reforzado han sido suficientemente tratados. En cuanto a los trabajos teóricos, las diferentes propuestas se basan en los métodos utilizados para hormigón armado y comparten los principios habituales de cálculo. Sin embargo, presentan diferencias relativas, sobre todo, a tres aspectos: 1) la forma de modelar el comportamiento de la fábrica, 2) el valor de deformación de cálculo del refuerzo, y 3) el modo de fallo que se considera recomendable buscar con el diseño. A pesar de ello, el ajuste con la parte experimental de cada trabajo suele ser bueno debido a una enorme disparidad en las variables consideradas. Cada campaña presenta un modo de fallo característico y la formulación que se propone resulta apropiada para él. Parece necesario desarrollar un método de cálculo para fábricas flexocomprimidas reforzadas con FRP que pueda ser utilizado para todos los posibles fallos, tanto atribuibles a la lámina como a la fábrica. En el apartado III.4 se repasan algunas lesiones habituales en fábricas solicitadas a flexión y se recogen ejemplos de refuerzos con FRP para reparar o prevenir estos daños. Para mejorar el conocimiento sobre el tema, se llevan a cabo dos pequeñas campañas experimentales realizadas en el Instituto de Ciencias de la Construcción Eduardo Torroja. La primera acerca de la adherencia de materiales compuestos encolados a fábricas deterioradas (apartado IV.1) y la segunda sobre el comportamiento estructural a flexocompresión de probetas de fábrica reforzadas con estos materiales (apartado IV.2). En el capítulo V se analizan algunos de los modelos de adherencia propuestos para prevenir el despegue del extremo del refuerzo. Se confirma que las predicciones obtenidas con ellos resultan muy dispares. Se recopila una base de datos con los resultados experimentales de campañas sobre adherencia de FRP a fábricas extraídas de la literatura y de los resultados propios de la campaña descrita en el punto IV.1. Esta base de datos permite conocer cual de los métodos analizados resulta más adecuado para dimensionar el anclaje de láminas de FRP adheridas a fábricas. En el capítulo VI se propone un método para la comprobación en agotamiento de secciones de fábrica reforzadas con materiales compuestos sometidas a esfuerzos combinados de flexión y compresión. Está basado en el procedimiento de cálculo de la capacidad resistente de secciones de hormigón armado pero adaptado a las fábricas reforzadas. Para ello, se utiliza un diagrama de cálculo tensión deformación de la fábrica de tipo bilineal (acorde con el CTE DB SE-F) cuya simplicidad facilita el desarrollo de toda la formulación al tiempo que resulta adecuado para predecir la capacidad resistente a flexión tanto para fallos debidos al refuerzo como a la fábrica. Además se limita la deformación de cálculo del refuerzo teniendo en consideración ciertos aspectos que provocan que la lámina adherida no pueda desarrollar toda su resistencia, como el desprendimiento inducido por fisuras en el interior del elemento o el deterioro medioambiental. En concreto, se propone un “coeficiente reductor por adherencia” que se determina a partir de una base de datos con 68 resultados experimentales procedentes de publicaciones de varios autores y de los ensayos propios de la campaña descrita en el punto IV.2. También se revisa la formulación propuesta con ayuda de la base de datos. En el capítulo VII se estudia la incidencia de las principales variables, como el axil, la deformación de cálculo del refuerzo o su rigidez, en la capacidad final del elemento. Las conclusiones del trabajo realizado y las posibles líneas futuras de investigación se exponen en el capítulo VIII. ABSTRACT Strengthening of existing structures with externally bonded fiber reinforced polymers (FRP) has become the most common application of advanced composite materials in construction. These materials exhibit many advantages in comparison with traditional ones (corrosion resistance, light weight, easy to apply, etc.). But despite countless researches have been done, there are still doubts about some aspects of their behaviour and applications are carried out only with the help of guidelines, without official regulations. The aim of this work is to improve the knowledge on this retrofitting technique, particularly in regard to flexural strengthening of masonry structures. Reinforced concrete is often the strengthened material and external glued FRP plates are used to improve its flexural, shear or compressive (by wrapping) capacity. However the use of this technique on other materials like masonry structures looks promising. Unreinforced masonry is characterized for being a good material to support compressive stresses but really bad to withstand tensile ones. Glue composite plates can improve the flexural capacity of masonry elements subject to bending. But a proper bond between FRP sheet and masonry must be ensured to do that, especially in old buildings whose surface can be damaged due to being outside or ageing. The main objectives of the work and the methodology carried out are described In Chapter II. An extensive overview of the state of art is done in Chapter III. In Section III.1 physical and mechanical properties of fibers, matrix and composites and their main applications are related. Durability aspects are especially emphasized. Section III.2 includes an historical overview of theoretical and empirical researches on concrete structures strengthened gluing FRP plates to improve their flexural behaviour. Section III.3 focuses on the critical point of bonding between FRP and substrate. Some theoretical models to prevent debonding of FRP laminate are reviewed, it has made a distinction between models for detachment at the end of the plate or debonding in the intermediate zones due to the effects of cracks. It is observed a lack of agreement in the proposals. Some experimental studies on bonding between masonry and FRP are also related in this chapter. The particular characteristics of masonry structures are analyzed in Section III.4. Besides some empirical and theoretical investigations relative to improve their flexural capacity with FRP sheets are reviewed. The mechanical behaviour of strengthened walls subject to pure bending (without compression) has been established by several authors, but this is an unusual situation for real masonry. Neither mechanical behaviour of walls subject to bending and compression nor influence of axial load in the final capacity of the strengthened element are adequately studied. In regard to theoretical studies, the different proposals are based on reinforced concrete analytical methods and share common design principles. However, they present differences, especially, about three aspects: 1) the constitutive law of masonry, 2) the value of ultimate FRP strain and 3) the desirable failure mode that must be looked for. In spite of them, a good agreement between each experimental program and its theoretical study is often exhibited due to enormous disparity in considered test parameters. Each experimental program usually presents a characteristic failure mode and the proposed formulation results appropriate for this one. It seems necessary to develop a method for FRP strengthened walls subject to bending and compression enable for all failure modes (due to FRP or masonry). Some common damages in masonry subject to bending are explained in Section III.4. Examples of FRP strengthening to repair or prevent these damages are also written. Two small experimental programs are carried out in Eduardo Torroja Institute to improve the knowledge on this topic. The first one is concerned about the bond between FRP plates and damaged masonry (section IV.1) and the second one is related to the mechanical behaviour of the strengthened masonry specimens subject to out of plane bending combined with axial force (section IV.2). In the Chapter V some bond models to prevent the debonding at the FRP plate end are checked. It is confirmed that their predictions are so different. A pure-shear test database is compiled with results from the existing literature and others from the experimental program described in section IV.1. This database lets know which of the considered model is more suitable to design anchorage lengths of glued FRP to masonry. In the Chapter VI a method to check unreinforced masonry sections with external FRP strengthening subject to bending and compression to the ultimate limit state is proposed. This method is based on concrete reinforced one, but it is adapted to strengthened masonry. A bilinear constitutive law is used for masonry (according to CTE DB SE-F). Its simplicity helps to develop the model formulation and it has proven to be suitable to predict bending capacity either for FRP failures or masonry crushing. With regard to FRP, the design strain is limited. It is taken into account different aspects which cause the plate can’t reach its ultimate strength, like intermediate FRP debonding induced by opening cracking or environmental damage. A “bond factor” is proposed. It is obtained by means of an experimental bending test database that includes 68 results from the existing literature and from the experimental program described in section IV.2. The proposed formulation has also been checked with the help of bending database. The effects of the main parameters, like axial load, FRP design effective strain or FRP stiffness, on the bending capacity of the strengthened element are studied in Chapter VII. Finally, the main conclusions from the work carried out are summarized in Chapter VIII. Future lines of research to be explored are suggested as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently developed cold-formed LiteSteel beam (LSB) sections have found increasing popularity in residential, industrial and commercial buildings due to their light weight and cost-effectiveness. Currently, there is significant interest in the use of LSB sections as flexural members in floor joist systems, although they can be used as flexural and compression members in a range of building systems. The plastic bending behaviour and section moment capacity of LSB sections with web holes can be assumed to differ from those without, but have yet to be investigated. Hence, no appropriate design rules for determining the section moment capacity of LSB sections with web holes are yet available. This paper presents the results of an investigation of the plastic bending behaviour and section moment capacity of LSB sections with circular web holes. LSB sections with varying circular hole diameters and degrees of spacing were considered. The paper also describes the simplified finite element (FE) modelling technique employed in this study, which incorporates all of the significant behavioural effects that influence the plastic bending behaviour and section moment capacity of these sections. The numerical and experimental test results and associated findings are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the details of an experimental study of a cold-formed steel beam known as LiteSteel Beam (LSB) subject to combined shear and bending actions. The LSBs have the beneficial characteristics of torsionally rigid rectangular hollow flanges combined with economical fabrication processes from a single strip of high strength steel. They combine the stability of hot-rolled steel sections with the high strength to weight ratio of conventional cold-formed steel sections. The LSB sections are commonly used as flexural members in residential, industrial and commercial buildings. In order to ensure safe and efficient designs of LSBs, many research studies have been undertaken on the flexural and shear strengths of LSBs. To date, however, no investigation has been conducted into the strength of LSB sections under combined shear and bending actions. Hence a detailed experimental study involving 18 tests was undertaken to investigate the behaviour and strength of LSBs under combined shear and bending actions. Test results showed that AS/NZS 4600 design rules for unstiffened webs grossly underestimated the capacity of LSBs. Therefore improved design equations were proposed for the combined shear and bending capacities of LSBs based on experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The hollow flange beam (HFB) is a unique cold-formed steel section developed in Australia for use as a flexural member. Research has identified that the HFB section's flexural capacity for intermediate span members is limited by lateral distortional buckling, which is characterized by simultaneous lateral deflection, twist, and web distortion. This buckling behaviour is mainly due to the unique geometry of the section, comprising two torsionally stiff triangular flanges connected by a slender web. This paper presents a finite element analytical model suitable for non-linear analysis of HFB flexural members. The model includes all significant effects that may influence the ultimate capacity of such members, including material inelasticity, local buckling, member instability, web distortion, residual stresses, and geometric imperfections. It was found to accurately predict both the elastic lateral distortional buckling moments and the ultimate capacities of HFB flexural members, and was therefore used in the development of design curves and suitable design procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the details of an experimental study of a cold-formed steel hollow flange channel beam known as LiteSteel Beam (LSB) subject to combined bending and shear actions. The LSB sections are produced by a patented manufacturing process involving simultaneous cold-forming and electric resistance welding. Due to the geometry of the LSB, as well as its unique residual stress characteristics and initial geometric imperfections resultant of manufacturing processes, much of the existing research for common cold-formed steel sections is not directly applicable to LSB. Experimental and numerical studies have been carried out to evaluate the behaviour and design of LSBs subject to pure bending actions and predominant shear actions. To date, however, no investigation has been conducted into the strength of LSB sections under combined bending and shear actions. Combined bending and shear is especially prevalent at the supports of continuous span and cantilever beams, where the interaction of high shear force and bending moment can reduce the capacity of a section to well below that for the same section subject only to pure shear or moment. Hence experimental studies were conducted to assess the combined bending and shear behaviour and strengths of LSBs. Eighteen tests were conducted and the results were compared with current AS/NZS 4600 and AS 4100 design rules. AS/NZS 4600 design rules were shown to grossly underestimate the combined bending and shear capacities of LSBs and hence two lower bound design equations were proposed based on experimental results. Use of these equations will significantly improve the confidence and cost-effectiveness of designing LSBs for combined bending and shear actions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ultimate bearing capacity of a circular footing, placed over a soil mass which is reinforced with horizontal layers of circular reinforcement sheets, has been determined by using the upper bound theorem of the limit analysis in conjunction with finite elements and linear optimization. For performing the analysis, three different soil media have been separately considered, namely, (i) fully granular, (ii) cohesive frictional, and (iii) fully cohesive with an additional provision to account for an increase of cohesion with depth. The reinforcement sheets are assumed to be structurally strong to resist axial tension but without having any resistance to bending; such an approximation usually holds good for geogrid sheets. The shear failure between the reinforcement sheet and adjoining soil mass has been considered. The increase in the magnitudes of the bearing capacity factors (N-c and N-gamma) with an inclusion of the reinforcement has been computed in terms of the efficiency factors eta(c) and eta(gamma). The results have been obtained (i) for different values of phi in case of fully granular (c=0) and c-phi soils, and (ii) for different rates (m) at which the cohesion increases with depth for a purely cohesive soil (phi=0 degrees). The critical positions and corresponding optimum diameter of the reinforcement sheets, for achieving the maximum bearing capacity, have also been established. The increase in the bearing capacity with an employment of the reinforcement increases continuously with an increase in phi. The improvement in the bearing capacity becomes quite extensive for two layers of the reinforcements as compared to the single layer of the reinforcement. The results obtained from the study are found to compare well with the available theoretical and experimental data reported in literature. (C) 2014 The Japanese Geotechnical Society. Production and hosting by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is presented for determining the ultimate bearing capacity of a circular footing reinforced with a horizontal circular sheet of reinforcement placed over granular and cohesive-frictional soils. It was assumed that the reinforcement sheet could bear axial tension but not the bending moment. The analysis was performed based on the lower-bound theorem of the limit analysis in combination with finite elements and linear optimization. The present research is an extension of recent work with strip foundations reinforced with different layers of reinforcement. To incorporate the effect of the reinforcement, the efficiency factors eta(gamma) and eta(c), which need to be multiplied by the bearing capacity factors N-gamma and N-c, were established. Results were obtained for different values of the soil internal friction angle (phi). The optimal positions of the reinforcements, which would lead to a maximum improvement in the bearing capacity, were also determined. The variations of the axial tensile force in the reinforcement sheet at different radial distances from the center were also studied. The results of the analysis were compared with those available from literature. (C) 2014 American Society of Civil Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bonded-in rod connections in timber possess many desirable attributes in terms of efficiency, manufacture, performance, aesthetics and cost. In recent years research has been conducted on such connections using fibre reinforced polymers (FRPs) as an alternative to steel. This research programme investigates the pull-out capacity of Basalt FRP rods bonded-in in low grade Irish Sitka Spruce. Embedded length is thought to be the most influential variable contributing to pull- out capacity of bonded-in rods after rod diameter. Previous work has established an optimum embedded length of 15 times the hole diameter. However, this work only considered the effects of axial stress on the bond using a pull-compression testing system which may have given an artificially high pull out capacity as bending effects were neglected. A hinge system was utilised that allows the effects of bending force to be taken in to consideration along with axial forces in a pull-out test. This paper describes an experimental programme where such pull-bending tests were carried out on samples constructed of 12mm diameter BFRP bars with a 2mm glueline thickness and embedded lengths between 80mm and 280mm bonded-in to low-grade timber with an epoxy resin. Nine repetitions of each were tested. A clear increase in pull-out strength was found with increasing embedded length.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eurocode 8 representing a new generation of structural design codes in Europe defines ‎requirements for the design of buildings against earthquake action. In Central and ‎Western Europe, the newly defined earthquake zones and corresponding design ground ‎acceleration values, will lead in many cases to earthquake actions which are remarkably ‎higher than those defined so far by the design codes used until now in Central Europe. ‎ In many cases, the weak points of masonry structures during an earthquake are the corner ‎regions of the walls. Loading of masonry walls by earthquake action leads in most cases ‎to high shear forces. The corresponding bending moment in such a wall typically causes a ‎significant increase of the eccentricity of the normal force in the critical wall cross ‎section. This in turn leads ultimately to a reduction of the size of the compression zone in ‎unreinforced walls and a high concentration of normal stresses and shear stresses in the ‎corner regions. ‎ Corner-Gap-Elements, consisting of a bearing beam located underneath the wall and ‎made of a sufficiently strong material (such as reinforced concrete), reduce the effect of ‎the eccentricity of the normal force and thus restricts the pinching effect of the ‎compression zone. In fact, the deformation can be concentrated in the joint below the ‎bearing beam. According to the principles of the Capacity Design philosophy, the ‎masonry itself is protected from high stresses as a potential cause of brittle failure. ‎ Shaking table tests at the NTU Athens Earthquake Engineering Laboratory have proven ‎the effectiveness of the Corner-Gap-Element. The following presentation will cover the ‎evaluation of various experimental results as well as a numerical modeling of the ‎observed phenomena.‎

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This present work examines the load carrying capacity, energy absorption and fracture characteristics of wrought magnesium and aluminium alloy tubes in three-point bending. Magnesium alloy AZ31, and aluminium alloys 6063 and 7075, were extruded into cylindrical tubes of both equivalent thickness and mass. A strong thickness effect was present meaning that the AZ31 tube had significantly higher load and energy absorption performance than an equivalent mass 6063 tube, albeit not as high as the 7075 tube. Hinge formation and maximum load was delayed for the magnesium alloy, meaning that a high energy absorption rate persisted to higher deformation displacements than the aluminium alloys. It was also found that fracture during deformation was dependent on the indenter diameter, tube thickness and lower support separation.