998 resultados para b scan
Resumo:
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
Resumo:
To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.
Resumo:
PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.
Resumo:
PURPOSE: To investigate six cases of annular cyclitis. METHODS: All patients with impairment of visual acuity underwent complete ophthalmologic examination, color fundus photography, laboratory tests and fluorescein angiography. Indocyanine green (ICG) angiography and B-scan ultrasonography were also performed in three cases in order to diagnose the disease. RESULTS: All patients presented a unilateral or bilateral granulomatous uveitis, associated with inflammatory annular cyclitis. They had a shallow anterior chamber, a mildly elevated intraocular pressure (under 25 mm Hg) and an annular serous retinal detachment. A resolution was observed after specific therapy associated with systemic prednisolone therapy and antiglaucomatous drops. CONCLUSION: This is the first description of an observational study of six patients with inflammatory annular cyclitis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Estudaram-se as alterações tonométricas, paquimétricas e de comprimento axial em cães com glaucoma submetidos à ablação uveal intravítrea. Foram avaliados 13 olhos irreversivelmente cegos de cães que apresentavam glaucoma crônico unilateral, nos quais realizou-se a ablação uveal intra-vítrea, por meio de injeção na câmara vítrea de 0,5ml de sulfato de gentamicina (40mg/ml) associado a 0,3ml de fosfato de dexametasona (4mg/ml). As mensurações da pressão intra-ocular (Po), espessura corneana e eixo axial com tonometria de aplanação, paquimetria ultra-sônica e ultra-sonografias modos A e B foram realizadas no dia da ablação (M0) e após uma (M1), quatro (M4), oito (M8), 12 (M12), 24 (M24) e 48 semanas (M48). A Po diminuiu significativamente em todos os momentos em relação ao M0, com aumento da espessura corneana ao longo do experimento. Nas avaliações ultra-sonográficas notou-se diminuição significativa do bulbo ocular a partir de M4, com medidas ultra-sonográficas modo A significativamente maiores que as do modo B. O procedimento foi efetivo na redução da Po e na diminuição do eixo axial, demonstrando ser viável no controle do glaucoma crônico em olhos irreversivelmente cegos, e ser uma alternativa à enucleação e inserção de prótese ocular.
Resumo:
Conhecer o aspecto e as dimensões de olhos de cabras facilita o uso da ultrassonografia na avaliação de doenças oculares. O objetivo do presente trabalho foi o de avaliar os achados ultrassonográficos e ecobiométricos em olhos de cabras adultas. Ultrassonogramas nos modos A e B foram realizados em 30 caprinos adultos (60 olhos) (n=15 fêmeas intactas e n=15 machos castrados). O exame ultrassonográfico foi realizado após a instilação de colírio anestésico. Gel a base de água foi utilizado sobre o transdutor de 20 MHz posicionado-o de forma longitudinasobre a córneal, até que imagens no modo B estivessem de acordo com os ecos gerados pelo modo A. Utilizou-se análise estatística para se comparar os achados ecobiométricos entre os sexos (p<0,05). As médias com seus respectivos desvios padrões das estruturas oculares em machos e fêmeas foram, respectivamente, 3,46±0,55, 3,33±0,46mm (profundidade da câmara anterior); 8,60±0,34, 8,65±0,39mm (espessura da lente); 11,34±0,61, 11,39±0,66mm (profundidade da câmara vítrea) e 23,43±0,92, 23,39±0.86mm (comprimento axial do bulbo ocular). Não foi observada diferença significativa entre os olhos direito e esquerdo, assim como entre machos e fêmeas (p>0,05). O aspecto ultrassonográfico de olhos de cabras se assemelha com o de outras espécies domésticas e silvestres.
Resumo:
This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples. © 2010 American Institute of Physics.
Resumo:
PURPOSE. We previously demonstrated that most eyes have regionally variable extensions of Bruch's membrane (BM) inside the clinically identified disc margin (DM) that are clinically and photographically invisible. We studied the impact of these findings on DM- and BM opening (BMO)-derived neuroretinal rim parameters. METHODS. Disc stereo-photography and spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) were performed on 30 glaucoma patients and 10 age-matched controls. Photographs were colocalized to SD-OCT data such that the DM and BMO could be visualized in each B-scan. Three parameters were computed: (1) DM-horizontal rim width (HRW), the distance between the DM and internal limiting membrane (ILM) along the DM reference plane; (2) BMO-HRW, the distance between BMO and ILM along the BMO reference plane; and (3) BMO-minimum rim width (MRW), the minimum distance between BMO and ILM. Rank-order correlations of sectors ranked by rim width and spatial concordance measured as angular distances between equivalently ranked sectors were derived. RESULTS. The average DM position was external to BMO in all quadrants, except inferotemporally. There were significant sectoral differences among all three rim parameters. DM- HRW and BMO-HRW sector ranks were better correlated (median rho = 0.84) than DM- HRW and BMO-MRW (median rho = 0.55), or BMO-HRW and BMO-MRW (median rho = 0.60) ranks. Sectors with the narrowest BMO-MRW were infrequently the same as those with the narrowest DM-HRW or BMO-HRW. CONCLUSIONS. BMO-MRW quantifies the neuroretinal rim from a true anatomical outer border and accounts for its variable trajectory at the point of measurement. (Invest Ophthalmol Vis Sci. 2012;53:1852-1860) DOI:10.1167/iovs.11-9309
Resumo:
Malignant melanomas (MMs) of the parotid gland are relatively uncommon. They occur almost invariably as metastases from a primary tumour located in the region of the scalp or the mucous membranes of the nose, paranasal sinuses, or throat. Primary MMs arising in the parotid gland are extremely rare. It is assumed that they originate in the glandular tissue or in intraglandular lymph nodes. We present a case report and review of the literature on the diagnosis, treatment, and prognosis of intraparotid malignant melanoma. Diagnosis is based primarily on B-scan ultrasonography and fine-needle aspiration cytology. Patients with a cytological diagnosis of MM are further evaluated by magnetic resonance imaging and positron emission tomography and receive a thorough ear-nose-throat and dermatological examination. The treatment of choice is total parotidectomy and selective neck dissection. The effectiveness of adjuvant treatments such as radiotherapy, chemotherapy, or immunotherapy remains controversial. Patients with primary MMs of the parotid gland appear to have a better prognosis than those with parotid metastases from melanomas of the skin or mucous membranes.
Resumo:
PURPOSE: To describe and follow cotton wool spots (CWS) in branch retinal vein occlusion (BRVO) using multimodal imaging. METHODS: In this prospective cohort study including 24 patients with new-onset BRVO, CWS were described and analyzed in color fundus photography (CF), spectral domain optical coherence tomography (SD-OCT), infrared (IR) and fluorescein angiography (FA) every 3 months for 3 years. The CWS area on SD-OCT and CF was evaluated using OCT-Tool-Kit software: CWS were marked in each single OCT B-scan and the software calculated the area by interpolation. RESULTS: 29 central CWS lesions were found. 100% of these CWS were visible on SD-OCT, 100% on FA and 86.2% on IR imaging, but only 65.5% on CF imaging. CWS were visible for 12.4 ± 7.5 months on SD-OCT, for 4.4 ± 3 months and 4.3 ± 3.4 months on CF and on IR, respectively, and for 17.5 ± 7.1 months on FA. The evaluated CWS area on SD-OCT was larger than on CF (0.26 ± 0.17 mm(2) vs. 0.13 ± 0.1 mm(2), p < 0.0001). The CWS area on SD-OCT and surrounding pathology such as intraretinal cysts, avascular zones and intraretinal hemorrhage were predictive for how long CWS remained visible (r(2) = 0.497, p < 0.002). CONCLUSIONS: The lifetime and presentation of CWS in BRVO seem comparable to other diseases. SD-OCT shows a higher sensitivity for detecting CWS compared to CF. The duration of visibility of CWS varies among different image modalities and depends on the surrounding pathology and the CWS size.
Resumo:
The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of modulators topologies, is intended to accelerate the design process and evaluation of modulators. This design tool is further developed to enable the design, analysis and evaluation of beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.
Resumo:
Background : In tropical countries, losses caused by bovine tick Rhipicephalus (Boophilus) microplus infestation have a tremendous economic impact on cattle production systems. Genetic variation between Bos taurus and Bos indicus to tick resistance and molecular biology tools might allow for the identification of molecular markers linked to resistance traits that could be used as an auxiliary tool in selection programs. The objective of this work was to identify QTL associated with tick resistance/susceptibility in a bovine F2 population derived from the Gyr (Bos indicus) x Holstein (Bos taurus) cross. Results: Through a whole genome scan with microsatellite markers, we were able to map six genomic regions associated with bovine tick resistance. For most QTL, we have found that depending on the tick evaluation season (dry and rainy) different sets of genes could be involved in the resistance mechanism. We identified dry season specific QTL on BTA 2 and 10, rainy season specific QTL on BTA 5, 11 and 27. We also found a highly significant genome wide QTL for both dry and rainy seasons in the central region of BTA 23. Conclusions: The experimental F2 population derived from Gyr x Holstein cross successfully allowed the identification of six highly significant QTL associated with tick resistance in cattle. QTL located on BTA 23 might be related with the bovine histocompatibility complex. Further investigation of these QTL will help to isolate candidate genes involved with tick resistance in cattle.
Resumo:
The Z-scan and thermal-lens techniques have been used to obtain the energy transfer upconversion parameter in Nd(3+)-doped materials. A comparison between these methods is done, showing that they are independent and provide similar results. Moreover, the advantages and applicability of each one are also discussed. The results point to these approaches as valuable alternative methods because of their sensitivity, which allows measurements to be performed in a pump-power regime without causing damage to the investigated material. (C) 2009 Optical Society of America