129 resultados para autofluorescence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the association between conjunctival ultraviolet autofluorescence (UVAF), a biomarker of ocular ultraviolet radiation (UVR) exposure, and prevalent pterygium. Methods: We conducted a cross-sectional study on Norfolk Island, South Pacific. All permanent residents aged ‡15 were invited to participate. Participants completed a sun exposure questionnaire and underwent autorefraction and slit lamp biomicroscope examination. Area of conjunctival UVAF (sum of temporal ⁄ nasal area in right and left eyes) was determined using computerized methods. Multivariate logistic and linear regression models were used to estimate the associations with pterygia and UVAF, respectively. Results: Of 641 participants, 70 people (10.9%) had pterygium in one or both eyes, and prevalence was higher in males (15.0% versus 7.7%, p = 0.003). Significant independent associations with pterygium in any eye were UVAF (per 10 mm2) [odds ratio (OR) 1.16, 95% confidence interval (CI) 1.16–1.28, p = 0.002], tanning skin phenotype (OR 2.17,1.20–3.92, p = 0.010) and spending more than three-quarters of the day outside (OR 2.22, 1.20–4.09, p = 0.011). Increasing quartile of UVAF was associated with increased risk of pterygium following adjustment of age, sex and time outdoors (pTrend = 0.002). Independent associations with increasing UVAF (per 10 mm2) were decreasing age, time outdoors, skin type and male gender (all p < 0.001). UVAF area correlated well with the duration of outdoor activity (pTrend < 0.001). Conclusion: Pterygium occurs in approximately one-tenth of Norfolk Islanders. Increasing conjunctival UVAF is associated with prevalent pterygia, confirming earlier epidemiological, laboratory and ray-tracing studies that pterygia are associated with UVR. Protection from the sun should be encouraged to reduce the prevalence of pterygium in the community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Conjunctival ultraviolet autofluorescence (UVAF) photography was developed to detect and characterise pre-clinical sunlight-induced UV damage. The reliability of this measurement and its relationship to outdoor activity are currently unknown. METHODS: 599 people aged 16-85 years in the cross-sectional Norfolk Island Eye Study were included in the validation study. 196 UVAF individual photographs (49 people) and 60 UVAF photographs (15 people) of Norfolk Island Eye Study participants were used for intra- and inter-observer reliability assessment, respectively. Conjunctival UVAF was measured using UV photography. UVAF area was calculated using computerised methods by one grader on two occasions (intra-observer analysis) or two graders (inter-observer analysis). Outdoor activity category, during summer and winter separately, was determined with a UV questionnaire. Total UVAF equalled the area measured in four conjunctival areas (nasal/temporal conjunctiva of right and left eyes). RESULTS: Intra-observer (ρ_c=0.988, 95% CI 0.967 to 0.996, p<0.001), and inter-observer concordance correlation coefficients (ρ_c=0.924, 95% CI 0.870 to 0.956, p<0.001) of total UVAF exceeded 0.900. When grouped according to 10 mm(2) total UVAF increments, intra- and inter-observer reliability was very good (κ=0.81) and good (κ=0.71), respectively. Increasing time outdoors was strongly with increasing total UVAF in summer and winter (p(trend) <0.001). CONCLUSION: Intra- and inter-observer reliability of conjunctival UVAF is high. In this population, UVAF correlates strongly with the authors' survey-based assessment of time spent outdoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To determine the sensitivity and specificity of the non-invasive imaging technique, fundus autofluorescence (AF), in the diagnosis of cystoid macular oedema (CMO), using fluorescein angiography as the reference standard. Design: Retrospective, consecutive, observational case series. Methods: Ninety-six consecutive patients with CMO suspected clinically were selected from the AF database of the Retina Unit, Ophthalmology Department, Grampian University Hospitals-NHS Trust, between August 2004 and June 2006. Only patients in whom CMO was secondary to (1) cataract extraction, (2) inherited retinopathies, (3) inflammatory eye disease or (4) idiopathic cases were included in this study. Only patients in whom AF images had been performed within 2 weeks of FFA and, when obtained following FFA, there was a minimum gap of 4 days ("washing out" period), were considered eligible for this study. A total of 34 eyes from 34 patients were eligible and were included in this study. FFA was used as the reference test to confirm the presence of CMO, and, based on fluorescein angiography (FFA), CMO was graded as either mild or florid. AF images were examined in a masked fashion for the presence or absence of CMO. The sensitivity and specificity of AF in detecting CMO were then calculated. Results: CMO was seen on AF imaging as round or oval areas at the fovea with an AF signal similar to that of background levels. At this site (fovea), the AF signal is usually reduced compared with background, due to the blockage caused by luteal pigment. The diagnosis of CMO based on AF imaging had 81% sensitivity and 69% specificity when compared with the reference standard FFA. Based on the FFA, there were 12 cases of florid CMO and eight of mild CMO. Of the former, CMO was detected with AF imaging in 100% (12/12 eyes), and of the latter, in 50% (4/8 eyes). Conclusions: AF imaging can be used as a rapid, non-invasive technique in the diagnosis of CMO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the distribution of fundus autofluorescence in patients with age-related macular degeneration and choroidal neovascularisation (CNV). Methods: Colour fundus photographs, fundus fluorescein angiograms (FFA) and fundus autofluorescence images were obtained from a group of 40 patients (43 eyes) with age-related macular degeneration and purely classic or occult CNV. Only patients with newly diagnosed CNV and in whom autofluorescence images were obtained within 2 weeks from FFA were included. The distribution of autofluorescence was qualitatively evaluated, and the findings compared with those from colour fundus photographs and FFA. Results: 29 (67%) eyes had classic CNV and 14 (33%) had occult CNV. In 26 (90%) eyes with classic CNV, a low autofluorescence signal was detected at the site of the CNV; in 7 (50%) eyes with occult CNV, multiple foci of low autofluorescence signal were detected. Outside the area affected by the lesion, homogeneous autofluorescence was observed in most of the cases (n = 33, 77%). Similarly, homogeneous autofluorescence was commonly observed in fellow eyes (62%). A pattern of focal increased autofluorescence was rarely seen in eyes with CNV (n = 4, 9%) or in fellow eyes (n = 4, 15%). In 11 of 43 (25%) eyes, areas of increased autofluorescence, other than a pattern of focal increased autofluorescence, were detected. In four patients, autofluorescence images had been obtained before the development of CNV; in none was any increased autofluorescence detected before the formation of CNV. Conclusions: Distinct patterns of autofluorescence were observed in eyes with pure classic and occult CNV. Increased autofluorescence was rarely seen in eyes with CNV and in fellow eyes, suggesting that increased autofluorescence, and thus, retinal pigment epithelium lipofuscin, may not play an essential part in the formation of CNV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To quantify autofluorescence (AF) levels in patients with Stargardt macular dystrophy-fundus flavimaculatus (STGD-FFM), and to identify patterns of AF. Design Observational, comparative study. Methods Prospective study. Settings Patients were recruited at Moorfields Eye Hospital. Study population Forty-three STGD-FFM patients aged 20 to 40 years and 35 age-matched normal volunteers. The right eye was chosen arbitrarily for measures of AF. Intervention The AF images were obtained using a confocal scanning laser ophthalmoscope. Levels of AF across the macula were measured. The distribution of AF was also evaluated. In 36 patients (84%) pattern electroretinogram (PERG) and full-field ERG were obtained and results were evaluated with respect to levels of AF. Main outcome measures Values of AF, AF distribution, PERG, and ERG. Results Normal or high AF at the center of the macula with high AF temporally or nasally or both was detected in 17 patients (39%). In nine (21%), low AF at the center of the macula with normal or low AF temporally or nasally or both was found. Levels of AF were normal throughout the macula in six patients (14%). In 11 (26%), high, normal, and low levels of AF were found. All patients tested with low AF at the center of the macula and normal or low AF temporally or nasally or both had peripheral cone/rod dysfunction. None of the patients tested that had normal or high AF at the fovea and high AF temporally or nasally, or normal AF throughout the macula, had peripheral cone/rod dysfunction. Conclusion AF is not universally high in STGD-FFM. Some patients have normal or low AF. Autofluorescence patterns appear to relate to functional abnormalities. © 2004 by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To describe and classify patterns of abnormal fundus autofluorescence (FAF) in eyes with early nonexudative age-related macular disease (AMD). METHODS. FAF images were recorded in eyes with early AMD by confocal scanning laser ophthalmoscopy (cSLO) with excitation at 488 nm (argon or OPSL laser) and emission above 500 or 521 nm (barrier filter). A standardized protocol for image acquisition and generation of mean images after automated alignment was applied, and routine fundus photographs were obtained. FAF images were classified by two independent observers. The ? statistic was applied to assess intra- and interobserver variability. RESULTS. Alterations in FAF were classified into eight phenotypic patterns including normal, minimal change, focal increased, patchy, linear, lacelike, reticular, and speckled. Areas with abnormal increased or decreased FAF signals may or may not have corresponded to funduscopically visible alterations. For intraobserver variability, ? of observer I was 0.80 (95% confidence interval [CI]0.71-0.89) and of observer II, 0.74. (95% CI, 0.64-0.84). For interobserver variability, ? was 0.77 (95% CI, 0.67-0.87). CONCLUSIONS. Various phenotypic patterns of abnormal FAF can be identified with cSLO imaging. Distinct patterns may reflect heterogeneity at a cellular and molecular level in contrast to a nonspecific aging process. The results indicate that the classification system yields a relatively high degree of intra- and interobserver agreement. It may be applicable for determination of novel prognostic determinants in longitudinal natural history studies, for identification of genetic risk factors, and for monitoring of future therapeutic interventions to slow the progression of early AMD. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe fundus autofluorescence (AF) patterns and their change over time in patients with age-related macular degeneration (AMD) and high risk of visual loss participating in the drusen laser study (DLS). DESIGN: Randomized clinical trial. METHODS: The study population consisted of 29 patients (35 eyes) participating in the DLS, which is a prospective, randomized, controlled clinical trial of prophylactic laser therapy in patients with AMD and high risk of neovascular complications. The intervention consisted of 16 eyes having prophylactic laser and 19 receiving no treatment. The main outcome measures were changes in the distribution of drusen and AF. Patients were reviewed for a median follow-up or 24 months (range 12-36 months). RESULTS: At baseline, four patterns of fundus AF were recognized: focal increased AF (n = 18), reticular AF (n = 3), combined focal and reticular AF (n = 2), and homogeneous AF (n = 12). At last follow-up, fundus AF remained unchanged in 15 untreated (78%) and in seven treated (43%) eyes. In only one untreated eye, focal areas of increased AF returned to background levels and were no longer detectable at last follow-up, compared with six treated eyes. This difference was statistically significant (P = .03). Only large foveal soft drusen (drusenoid pigment epithelium detachments) consistently corresponded with focal changes in AF, whereas no obvious correspondence was found between small soft drusen located elsewhere and changes in AF. CONCLUSION: The lack of obvious correspondence between the distribution of drusen and of AF found in this study appears to indicate that drusen and AF represent independent measures of aging in the posterior pole. © 2002 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - To evaluate the reproducibility of the background fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Methods - 10 normal volunteers and 10 patients with retinal disease were included in the study. One eye per subject was chosen randomly. Five images of the same eye of each individual were obtained, after pupillary dilatation, by two investigators using a confocal scanning laser ophthalmoscope. Background fundus autofluorescence was measured at 7 degrees temporal to the fovea in normal volunteers and between 7 and 15 degrees temporal to the fovea in patients. Within session reproducibility of the measurements obtained by each investigator and interobserver reproducibility were evaluated. Results - For investigator 1 the median values of fundus autofluorescence obtained were 31.9 units for normal volunteers and 27.3 units for patients. The median largest difference in readings in normal volunteers was 5.7 units (range 1.4-13.5 units) and in patients 4.2 units (1.5-15.1 units). For investigator 2 the median values of fundus autofluorescence obtained were 28.9 units for normal volunteers and 27.4 units for patients. The median largest difference in readings in normal volunteers was 3.6 units (2.7-11.7 units), and in patients 4.1 units (1.5-9.3 units). The median interobserver difference in readings in normal volunteers was 3.3 units and for patients 6.6 units. The median greatest interobserver difference in measurements obtained for normal volunteers was 8.8 units (8.4-23.0 units) and for patients 11.1 units (7.1-40.8 units). Conclusion - Within session reproducibility of the measurements of background fundus autofluorescence was satisfactory. Although interobserver reproducibility was moderate, the variability of the measurements of fundus autofluorescence between observers appears to be small when compared with variation in fundus autofluorescence with age and disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - To describe a new method of evaluating the topographic distribution of fundus autofluorescence in eyes with retinal disease. Methods - Images of fundus autofluorescence were obtained in five patients and 34 normal volunteers using a confocal scanning laser ophthalmoscope (cSLO). To evaluate the topographic distribution of fundus autofluorescence throughout the posterior pole a rectangular box, 10 x 750 pixels, was used as the area of analysis. The box was placed, horizontally, across the macular region. The intensity of fundus autofluorescence of each pixel within the rectangular box was plotted against its degree of eccentricity. Profiles of fundus autofluorescence from patients were compared with those obtained from the age matched control group and with cSLO images. Results - Profiles of fundus autofluorescence appeared to represent the topographic distribution of fundus autofluorescence throughout the posterior pole appreciated in the cSLO images, and allowed rapid identification and quantification of areas of increased or decreased fundus autofluorescence. Conclusions - Fundus autofluorescence profiles appear to be useful to study the spatial distribution of fundus autofluorescence in eyes with retinal disease.