998 resultados para attachment systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexao Sistemas de Protese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexao/O-ring; (ii) Conexao/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexao/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexao/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexao/Bar-Clip values were always significantly higher than those of Conexao/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexao/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the stress distribution in mandibular free-end removable partial dentures (RPD) associated with FPD in the abutment teeth considering different inclinations of the residual ridge: (1) horizontal and (2) distal descending ridges and two designs of free-end RPD with different attachment systems were tested: (1) clasp and (2) system ERA. Methods. Axial loads (100 N) were applied on the teeth of the RPD. The images were recorded and the stress distribution was evaluated through photoelastic fringes. Results. In general, the distal descending ridge presented more photoelastic fringes in the region of the roots of the abutment teeth while the horizontal ridge exhibited higher compression in the base of the prosthesis. In the horizontal ridge, the denture with clasp presented more favourable stress distribution than the denture with the system ERA. In the distal descending ridge, the denture with the system ERA relieved the region of the abutment teeth and overloaded the residual ridge. Conclusion: The horizontal ridge presented more favourable performance; the dentures with clasp exhibited better performance for both ridges evaluated; the denture with the system ERA presented better results in the distal descending ridge. © 2013 Informa Healthcare.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nano-fibrillar adhesives can adhere strongly to surfaces as a gecko does. The size of each fiber has significant effects on the adhesion enhancement, especially on rough surfaces. In the present study, we report the size effects on the normal and shear strength of adhesion for a single viscoelastic fiber. It is found that there exists a limited region of the critical sizes under which the interfacial normal or tangential tractions uniformly attain the theoretical adhesion strength. The region for a viscoelastic fiber under tension with similar material constants to a gecko's spatula is 135-255 nm and that under torque is 26.5-52 nm. This finding is significant for the development of artificial biomimetic attachment systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.