433 resultados para atrioventricular pacemaker


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the incidence of problems requiring reprogramming of atrioventricular pacemakers in a long-term follow-up, and also the causes for this procedure. METHODS: During the period from May '98 to December '99, 657 patients were retrospectively studied, An actuarial curve for the event reprogramming of the stimulation mode was drawn. RESULTS: The follow-up period ranged from 12 to 178 months (mean = 81 months). Eighty-two (12.4%) patients underwent reprogramming of the stimulation mode as follows: 63 (9.5%) changed to VVI,(R/C); 10 (1.5%) changed to DVI,C; 6 (0.9%) changed to VDD,C; and 3 (0.5%) changed to DOO. The causes for the reprogramming were as follows: arrhythmia conducted by the pacemaker in 39 (37.6%) patients; loss of atrial sensitivity or capture, or both, in 39 (38.6%) patients; and microfracture of atrial electrode in 5 (4.9%) patients. The stimulation mode reprogramming free probability after 15 years was 58%. CONCLUSION: In a long-term follow-up, the atrioventricular pacemaker provided a low incidence of complications, a high probability of permanence in the DDD,C mode, and the most common cause of reprogramming was arrhythmia conducted by the pacemaker.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background:Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation.Objectives:To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling.Methods:This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%.Results:A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)Conclusions:The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Congenital complete atrioventricular block (AVB) without cardiac malformation is a rare and potentially fatal condition. In most cases it is associated with maternal systemic lupus erythematosus through transplacental passage of antibodies anti-SSA/Ro and/or anti-SSB/La. Antenatal fluorinated-steroids have been successful in reversing first and second degree congenital AVB but inconsistent in third degree block. Case Report:The authors report a case of fetal bradycardia diagnosed at 24 weeks of gestation. The fetal echocardiogram revealed a second/third degree AVB without structural heart disease. Maternal anti-SSA/Ro antibodies were detected. There was no blockage improvement with maternal oral fluorinated-steroids. An elective cesarean section was performed at term with the delivery of a healthy girl that required an epicardical pacemaker on the 8th day of life. Conclusion: In this case, treatment with maternal fluorinated corticosteroids was not effective in preventing progression of the heart block.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59±13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR) between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%)heart transplant recipients required temporary pacing and 4 of 114 (3.5%) patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5%) and atrioventricular (AV) block in 3 patients (21.4%). The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75%) and atrioventricular (AV) block in 1 patient (25%). We observed rejection in 3 patients (21.4%) who required temporary pacing and in 2 patients (50%) who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4%) with temporary pacing. Seven of the 14 patients (50%) died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Isolated congenital atrioventricular block (CAVB) diagnosed in utero is associated with a high morbidity and mortality. Prognosis is especially poor when heart rate drops below 55 beats per minute (bpm) and when fetal hydrops develops. We describe the natural history and outcome of 24 infants with isolated CAVB diagnosed in utero, review the literature, and assess the risk factors that could predict outcome. METHODS: This was a retrospective multicenter study of 24 patients with isolated CAVB diagnosed in utero. RESULTS: CAVB was detected at a mean gestational age (GA) of 24.7 +/- 5.1 weeks. Ten fetuses initially presented with complete heart block. Low heart rate or incomplete heart block was the first documentation of bradyarrhythmia in the other 14 fetuses. In 11 of them, CAVB developed during pregnancy after a median time of 3 (range 1-16) weeks. Fetal hydrops developed in 10 of 24 (42%) fetuses at a mean GA of 27.6 +/- 5.1 weeks. Hydropic fetuses showed lower heart rates during pregnancy (47 +/- 10 bpm) than non-hydropic fetuses (57 +/- 10 bpm). There were three intrauterine deaths; all were hydropic and female. Nine viable females and 12 males were born at a mean GA of 37.1 +/- 6.1 weeks with an average birth weight of 3097 +/- 852 g. Fifteen CAVB patients required pacemaker (PM) intervention, 10 of them immediately after birth. Dilated cardiomyopathy (DCM) developed in three infants of whom two died of congestive heart failure, shortly after the diagnosis was made; one is still alive. Mortality before or after birth was 21%, and was associated with heart rates below 50 bpm and development of fetal hydrops. Poor outcome, defined as death, PM implantation, or development of DCM, occurred in 83% of cases and was associated with heart rates below 60 bpm during pregnancy. CONCLUSIONS: Isolated CAVB diagnosed in utero is associated with high morbidity and mortality. Patients who develop fetal hydrops show lower heart rates during pregnancy than patients who do not. A fetal heart rate below 50 bpm and development of fetal hydrops is associated with increased mortality. Rates below 60 bpm are associated with PM requirement and/or DCM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the clinical and electrophysiological characteristics of patients with paroxysmal palpitations and neck pounding during sinus rhythm. Methods Clinical, electrocardiographic, and electrophysiological characteristics of six patients with paroxysmal palpitations and neck pounding during sinus rhythm were studied in basal conditions and when symptomatic. Response to treatment was observed. Results Baseline ECGs were normal (four patients) or had first degree atrioventricular block with intermittent PR shortening. During symptoms, narrow QRS rhythms were seen without visible P waves (three patients) or with P waves partially hidden in the QRS complex (three patients). Dual atrioventricular nodal pathways were found in all five patients who had electrophysiological studies. In these patients the slow pathway conduction time was long enough (mean (SD), 425 (121)¿ms) for ventricular activation after slow pathway conduction during sinus rhythm to coincide with the next atrial depolarisation, causing neck pounding during exercise (four patients) or at rest (two patients). Tachycardia was not induced in any patient. Medical treatment aggravated symptoms in three patients. A pacemaker was successfully used in two. Conclusions Neck pounding during sinus rhythm is a clinical manifestation of dual atrioventricular nodal pathways. Medical treatment may aggravate symptoms but a pacemaker may offer definitive relief.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

First-degree atrio-ventricular (AV) block is defined as a PR interval longer than 200 ms. If too long, it can become clinically relevant and may mimic a pacemaker syndrome. We report the case of a young woman with a long PR interval, probably congenital, with episodes of syncope and dizziness since childhood. Pseudo-pacemaker syndrome is rare and is a Class IIa recommendation for a pacemaker implantation. A dual-chamber pacemaker was implanted and short AV delay was programmed, with rapid clinical improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The atrioventricular (AV) node is permanently damaged in approximately 3% of congenital heart surgery operations, requiring implantation of a permanent pacemaker. Improvements in pacemaker design and in alternative treatment modalities require an effective in vivo model of complete heart block (CHB) before testing can be performed in humans. Such a model should enable accurate, reliable, and detectable induction of the surgical pathology. Through our laboratory’s efforts in developing a tissue engineering therapy for CHB, we describe here an improved in vivo model for inducing chronic AV block. The method employs a right thoracotomy in the adult rabbit, from which the right atrial appendage may be retracted to expose an access channel for the AV node. A novel injection device was designed, which both physically restricts needle depth and provides electrical information via electrocardiogram interface. This combination of features provides real-time guidance to the researcher for confirming contact with the AV node, and documents its ablation upon formalin injection. While all animals tested could be induced to acute AV block, those with ECG guidance were more likely to maintain chronic heart block >12 h. Our model enables the researcher to reproduce both CHB and the associated peripheral fibrosis that would be present in an open congenital heart surgery, and which would inevitably impact the design and utility of a tissue engineered AV node replacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXTO: A síndrome de Alport é responsável por aproximadamente 5% dos pacientes com insuficiência renal crônica. Nessa doença, anormalidades no sistema de condução cardíaco são mais freqüentes que na população em geral. OBJETIVO: Relatar caso de síndrome de Alport que desenvolveu bloqueio atrioventricular total durante um transplante renal. RELATO DE CASO: Paciente masculino, 21 anos de idade, com insuficiência renal crônica secundária à síndrome de Alport, foi submetido a transplante renal sob anestesia peridural. Durante o procedimento anestésico-cirúrgico apresentou bloqueio atrioventricular total, que foi tratado rapidamente, e com sucesso, usando-se um marcapasso transcutâneo. O bloqueio simpático extenso pode contribuir para o desenvolvimento de distúrbios no sistema de condução cardíaco, particularmente em pacientes com insuficiência renal crônica em esquema de diálise. Mesmo em pacientes com eletrocardiograma pré-operatório normal e sem distúrbios de condução, graus variáveis de bloqueio atrioventricular, incluindo bloqueio atrioventricular total, podem ocorrer. Nesse caso, o uso de marcapasso transcutâneo é tratamento rápido e efetivo na sala de operação até o final da cirurgia, quando o tratamento definitivo pode ser planejado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Atrioventricular (AV) conduction disturbances requiring permanent pacemaker (PPM) implantation may complicate transcatheter aortic valve replacement (TAVR). Available evidence on predictors of PPM is sparse and derived from small studies. Objectives The objective of this study was to provide summary effect estimates for clinically useful predictors of PPM implantation after TAVR. Methods We performed a systematic search for studies that reported the incidence of PPM implantation after TAVR and that provided raw data for the predictors of interest. Data on study, patient, and procedural characteristics were abstracted. Crude risk ratios (RRs) and 95% confidence intervals for each predictor were calculated by use of random effects models. Stratified analyses by type of implanted valve were performed. Results We obtained data from 41 studies that included 11,210 TAVR patients, of whom 17% required PPM implantation after intervention. The rate of PPM ranged from 2% to 51% in individual studies (with a median of 28% for the Medtronic CoreValve Revalving System [MCRS] and 6% for the Edwards SAPIEN valve [ESV]). The summary estimates indicated increased risk of PPM after TAVR for men (RR: 1.23; p < 0.01); for patients with first-degree AV block (RR: 1.52; p < 0.01), left anterior hemiblock (RR: 1.62; p < 0.01), or right bundle branch block (RR: 2.89; p < 0.01) at baseline; and for patients with intraprocedural AV block (RR: 3.49; p < 0.01). These variables remained significant predictors when only patients treated with the MCRS bioprosthesis were considered. The data for ESV were limited. Unadjusted estimates indicated a 2.5-fold higher risk for PPM implantation for patients who received the MCRS than for those who received the ESV. Conclusions Male sex, baseline conduction disturbances, and intraprocedural AV block emerged as predictors of PPM implantation after TAVR. This study provides useful tools to identify high-risk patients and to guide clinical decision making before and after intervention.