958 resultados para artifact catalog


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the influence of metallic dental artifacts on the accuracy of simulated mandibular lesion detection by using multislice technology. MATERIAL AND METHODS: Fifteen macerated mandibles were used. Perforations were done simulating bone lesions and the mandibles were subjected to axial 16 rows multislice CT images using 0.5 mm of slice thickness with 0.3 mm interval of reconstruction. Metallic dental restorations were done and the mandibles were subjected again to CT in the same protocol. The images were analyzed to detect simulated lesions in the mandibles, verifying the loci number and if there was any cortical perforation exposing medullar bone. The analysis was performed by two independent examiners using e-film software. RESULTS: The samples without artifacts presented better results compared to the gold standard (dried mandible with perforations). In the samples without artifacts, all cortical perforation were identified and 46 loci were detected (of 51) in loci number analysis. Among the samples with artifacts, 12 lesions out of 14 were recognized regarding medullar invasion, and 40 out of 51 concerning loci number. The sensitivity in samples without artifacts was 90% and 100% regarding loci number and medullar invasion, respectively. In samples with artifacts, these values dropped to 78% and 86%, respectively. The presence of metallic restorations affected the sensitivity values of the method, but the difference was not significant (p>0.05). CONCLUSIONS: Although there were differences in the results of samples with and without artifacts, the presence of metallic restoration did not lead to misinterpretation of the final diagnosis. However, the validity of multislice CT imaging in this study was established for detection of simulated mandibular bone lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first deep catalog of the H I Parkes All Sky Survey (HIPASS) is presented, covering the south celestial cap (SCC) region. The SCC area is similar to2400 deg(2) and covers delta < -62&DEG;. The average rms noise for the survey is 13 mJy beam(-1). Five hundred thirty-six galaxies have been cataloged according to their neutral hydrogen content, including 114 galaxies that have no previous cataloged optical counterpart. This is the largest sample of galaxies from a blind H I survey to date. Most galaxies in optically unobscured regions of sky have a visible optical counterpart; however, there is a small population of low-velocity H I clouds without visible optical counterparts whose origins and significance are unclear. The rms accuracy of the HIPASS positions is found to be 1.'9. The H I mass range of galaxies detected is from &SIM;10(6) to &SIM;10(11) M-.. There are a large number of late-type spiral galaxies in the SCC sample (66%), compared with 30% for optically selected galaxies from the same region in the NASA Extragalactic Database. The average ratio of H I mass to B luminosity of the sample increases according to optical type, from 1.8 M-./L-. for early types to 3.2 M-./L-. for late-type galaxies. The H I-detected galaxies tend to follow the large-scale structure traced by galaxies found in optical surveys. From the number of galaxies detected in this region of sky, we predict the full HIPASS catalog will contain &SIM;5000 galaxies, to a peak flux density limit of &SIM;39 mJy (3 σ), although this may be a conservative estimate as two large voids are present in the region. The H I mass function for this catalog is presented in a subsequent paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a catalog of smells in the context of interactive applications. These so-called usability smells are indicators of poor design on an application’s user interface, with the potential to hinder not only its usability but also its maintenance and evolution. To eliminate such usability smells we discuss a set of program/usability refactorings. In order to validate the presented usability smells catalog, and the associated refactorings, we present a preliminary empirical study with software developers in the context of a real open source hospital management application. Moreover, a tool that computes graphical user interface behavior models, giving the applications’ source code, is used to automatically detect usability smells at the model level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catastrophic tsunamis are described in historical sources for all regions around the Gulf of Cadiz, at least since 60 BC. Most of the known events are associated with moderate to large earthquakes and among them the better studied is 1 November 1755. We present here a review of the events which effects, on the coasts of the Portuguese mainland and Madeira Island, are well described in historical documents or have been measured by tide gauges since the installation of these instruments. For a few we include new relevant information for the assessment of the tsunami generation or effects, and we discard events that are included in existing compilations but are not supported by quality historical sources or instrumental records. We quote the most relevant quantitative descriptions of tsunami effects on the Portuguese coast, including in all pertinent cases a critical review of the coeval sources, to establish a homogenous event list. When available, instrumental information is presented. We complement all this information with a summary of the conclusions established by paleo-tsunami research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Realidade Aumentada veio alterar a percepção que o ser humano tem do mundo real. A expansão da nossa realidade à Realidade Virtual possibilita a criação de novas experiencias, cuja aplicabilidade é já tida como natural em diversas situações. No entanto, potenciar este tipo de interacção pode ser um processo complexo, quer por limitações tecnológicas, quer pela gestão dos recursos envolvidos. O desenvolvimento de projectos com realidade aumentada para fins comerciais passa assim muitas vezes pela optimização dos recursos utilizados tendo em consideração as limitações das tecnologias envolventes (sistemas de detecção de movimento e voz, detecção de padrões, GPS, análise de imagens, sensores biométricos, etc.). Com a vulgarização e aceitação das técnicas de Realidade Aumentada em muitas áreas (medicina, educação, lazer, etc.), torna-se também necessário que estas técnicas sejam transversais aos dispositivos que utilizamos diariamente (computadores, tablets, telemóveis etc.). Um dominador comum entre estes dispositivos é a internet uma vez que as aplicações online conseguem abarcar um maior número de pessoas. O objectivo deste projecto era o de criar uma aplicação web com técnicas de Realidade Aumentada e cujos conteúdos fossem geridos pelos utilizadores. O processo de investigação e desenvolvimento deste trabalho passou assim por uma fase fundamental de prototipagem para seleccionar as tecnologias que melhor se enquadravam no tipo de arquitectura pretendida para a aplicação e nas ferramentas de desenvolvimento utilizadas pela empresa onde o projecto foi desenvolvido. A aplicação final é composta por um FrontOffice, responsável por mostrar e interpretar as aplicações criadas e possibilitar a integração com outras aplicações, e um BackOffice que possibilita aos utilizadores, sem conhecimentos de programação, criar novas aplicações de realidade aumentada e gerir os conteúdos multimédia utilizados. A aplicação desenvolvida pode servir de base para outras aplicações e ser reutilizável noutros âmbitos, sempre com o objectivo de reduzir custos de desenvolvimento e de gestão de conteúdos, proporcionando assim a implementação de uma Framework que permite a gestão de conteúdos em diferentes áreas (medicina, educação, lazer, etc.), onde os utilizadores podem criar as suas próprias aplicações, jogos e ferramentas de trabalho. No decorrer do projecto, a aplicação foi validada por especialistas garantindo o cumprimento dos objectivos propostos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.