998 resultados para area array CCD


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In der vorliegenden Forschungsarbeit wird die Konkurrenz von Kristallisation und Verglasung in metastabilen kolloidalen Hart-Kugel(HK)-Modellsystemen mit dynamischer und zeitaufgelöster statischer Lichtstreuung untersucht. Durch gleichzeitige Messungen mit beiden Methoden an derselben Probe gelang es, mit hoher Genauigkeit und aussagekräftiger Statistik nachzuweisen, dass in beiden Systemklassen eine starke Korrelation der strukturellen und dynamischen Eigenschaften vorliegt und diese Korrelation zu quantifizieren. Ein zentraler Teil der Arbeit bestand in dem Aufbau einer geeigneten Lichtstreuanlage mit der erstmalig Messungen der Dynamik und der Struktur simultan an derselben nicht-ergodischen Probe durchgeführt werden konnten. Für die dynamische Lichtstreuung wurde ein Flächendetektor (CCD-Kamera) verwendet. In Kombination mit einer speziellen Detektionsoptik ermöglicht dies, die gleichzeitige Detektion von Streulicht aus unterschiedlichen Probenbereichen (Subensembles). Damit kann gleichzeitig die Dynamik in unterschiedlichen Subensembles mit einer Auflösung von 15,8x15,8µm2 untersucht werden. Die Lichtstreuanlage wurde ausführlich charakterisiert und ihre korrekte Funktionsweise mithilfe von Vergleichsmessungen an etablierten Lichtstreuanlagen bestätigt. Die zeitliche Entwicklung der Dynamik und der Struktur von metastabilen Proben wurde unterhalb, am und oberhalb des Glasübergangs quantifiziert. Dabei zeigte das untersuchte kolloidale HK-Modellsystem alle typischen Eigenschaften eines HK-Systems. Die kristallisierenden Proben zeigten das etablierte zweistufige Kristallisationsszenario mit entsprechender Kristallisationskinetik und die Glasproben zeigten das erwartete Alterungsverhalten. Bei dem zweistufigen Kristallisationsszenario kommt es zuerst zur Nukleation einer metastabilen Zwischenphase von sogenannten Precursorn. In einer zweiten Stufe bilden sich Kristallite innerhalb dieser Precursor. Durch Vergleich zwischen kristallisierenden und verglasenden Proben konnte auch während der Verglasung die Bildung von Precursorn beobachtet werden. Die Korrelation zwischen der Anzahl an Precursorn und der Partikeldynamik legt die Vermutung nahe, dass das immer noch unverstandene Phänomen der Alterung von Gläsern mit der Bildung von Precursorn zusammenhängt. Verhinderte Kristallisation führt zu einer starken Verlangsamung der Partikeldynamik. Die Partikeldynamik einer Probe am Glasübergang zeigt, dass die Probe vor Einsetzen der Kristallisation eine glasartige Dynamik aufwies. Dies legt die Vermutung nahe, dass einkomponentige kolloidale HK-Gläser den Gleichgewichtszustand (Kristall) auf langen Zeitskalen erreichen können. Durch die Untersuchung der Partikeldynamik von metastabilen Proben in einzelnen Subensembles konnte eine heterogene Verteilung der Partikeldynamik nachgewiesen werden. Es existieren Bereiche, in denen die Partikeldynamik schneller oder langsamer ist als in anderen Bereichen. Gleichzeitig zeigen die Messungen der strukturellen Eigenschaften, dass metastabile Proben auch heterogen bezüglich ihrer Struktur sind. Mithilfe dieser Messungen konnte die zeitliche Entwicklung des Anteils an langsamen Partikeln und des Anteils an Partikeln innerhalb von Objekten höherer Ordnung (Precursor/Kristallite) bestimmt werden. Es zeigte sich eine direkte Korrelation zwischen dem Anteil an langsamen Partikeln und dem Anteil an Partikeln in Objekten höherer Ordnung. Die Untersuchung der Dynamik und der Struktur in einzelnen Subensembles lieferte einen weiteren Hinweis darauf, dass Subensembles, in denen eine stärker ausgeprägte strukturelle Ordnung vorliegt, auch bevorzugt eine langsamere Partikeldynamik aufweisen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Optical fibre strain sensors using Fibre Bragg Gratings (FBGs) are poised to play a major role in structural health monitoring in a variety of application from aerospace to civil engineering. At the heart of technology is the optoelectronic instrumentation required to convert optical signals into measurands. Users are demanding compact, lightweight, rugged and low cost solutions. This paper describes development of a new device based on a blazed FBG and CCD array that can potentially meet the above demands. We have shown that this very low cost technique may be used to interrogate a WDM array of sensor gratings with highly accurate and highly repeatable results unaffected by the polarisation state of the radiation. In this paper, we present results showing that sensors may be interrogated with an RMS error of 1.7pm, drift below 0.12pm and dynamic range of up to 65nm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Optical fibre strain sensors using Fibre Bragg Gratings (FBGs) are poised to play a major role in structural health monitoring in a variety of application from aerospace to civil engineering. At the heart of technology is the optoelectronic instrumentation required to convert optical signals into measurands. Users are demanding compact, lightweight, rugged and low cost solutions. This paper describes development of a new device based on a blazed FBG and CCD array that can potentially meet the above demands. We have shown that this very low cost technique may be used to interrogate a WDM array of sensor gratings with highly accurate and highly repeatable results unaffected by the polarisation state of the radiation. In this paper, we present results showing that sensors may be interrogated with an RMS error of 1.7pm, drift below 0.12pm and dynamic range of up to 65nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medium-resolution satellite images have been widely used for the identification and quantification of irrigated areas by center pivot. These areas, which present predominantly circular forms, can be easily identified by visual analyses of these images. In addition to identifying and quantifying areas irrigated by center pivot, other information that is associated to these areas is fundamental for producing cadastral maps. The goal of this work was to generate cadastral mapping of areas irrigated by center pivots in the State of Minas Gerais, Brazil, with the purpose of supplying information on irrigated agriculture. Using the satellite CBERS2B/CCD, images were used to identify and quantify irrigated areas and then associate these areas with a database containing information about: irrigated area, perimeter, municipality, path row, basin in which the pivot is located, and the date of image acquisition.3,781 center pivots systems were identified. The smallest area irrigated was 4.6 hectares and the largest one was 192.6 hectares. The total estimated value of irrigated area was 254,875 hectares. The largest number of center pivots appeared in the municipalities of Unaí and Paracatu, with 495 and 459 systems, respectively. Cadastral mapping is a very useful tool to assist and enhance information on irrigated agriculture in the State of Minas Gerais.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors present a systolic design for a simple GA mechanism which provides high throughput and unidirectional pipelining by exploiting the inherent parallelism in the genetic operators. The design computes in O(N+G) time steps using O(N2) cells where N is the population size and G is the chromosome length. The area of the device is independent of the chromosome length and so can be easily scaled by replicating the arrays or by employing fine-grain migration. The array is generic in the sense that it does not rely on the fitness function and can be used as an accelerator for any GA application using uniform crossover between pairs of chromosomes. The design can also be used in hybrid systems as an add-on to complement existing designs and methods for fitness function acceleration and island-style population management

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work reported in this paper proposes Swarm-Array computing, a novel technique inspired by swarm robotics, and built on the foundations of autonomic and parallel computing. The approach aims to apply autonomic computing constructs to parallel computing systems and in effect achieve the self-ware objectives that describe self-managing systems. The constitution of swarm-array computing comprising four constituents, namely the computing system, the problem/task, the swarm and the landscape is considered. Approaches that bind these constituents together are proposed. Space applications employing FPGAs are identified as a potential area for applying swarm-array computing for building reliable systems. The feasibility of a proposed approach is validated on the SeSAm multi-agent simulator and landscapes are generated using the MATLAB toolkit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We are reporting on the fabrication and electrical characterization of a novel elastomer based micro-cuff neural interface. Electrodes are gold (Au) tracks of sub-100nm thickness and are thermally evaporated on a 0.5 mm thick polydimethylsiloxane (PDMS) substrate. We investigate how electrode area and immersion in phosphate buffered saline (PBS) at 37°C influence electrode impedance. A microfluidic channel is bonded to the electrode array to form the cuff. In an acute, in-vivo, proof-of-principle recording, the device is capable of detecting light stroking and pinch of a hind leg of an anaesthetized rat.