The eco-epidemiology of T. cruzi infection was investigated in the Eastern border of the Panama Canal in Central Panama. Between 1999 and 2000, 1110 triatomines were collected: 1050 triatomines (94.6%) from palm trees, 27 (2.4%) from periurban habitats and 33 (3.0%) inside houses. All specimens were identified as R. pallescens. There was no evidence of vector domiciliation. Salivary glands from 380 R. pallescens revealed a trypanosome natural infection rate of 7.6%, while rectal ampoule content from 373 triatomines was 45%. Isoenzyme profiles on isolated trypanosomes demonstrated that 85.4% (n = 88) were T. cruzi and 14.6% (n = 15) were T. rangeli. Blood meal analysis from 829 R. pallescens demonstrated a zoophilic vector behavior, with opossums as the preferential blood source. Seroprevalence in human samples from both study sites was less than 2%. Our results demonstrate that T. cruzi survives in the area in balanced association with R. pallescens, and with several different species of mammals in their natural niches. However, the area is an imminent risk of infection for its population, consequently it is important to implement a community educational program regarding disease knowledge and control measures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite more than half a century of use in leishmaniasis, antimony therapy still presents serious problems concerning dosage and toxicity. Low and high doses have been shown to be equally effective. In this paper, the feasibility of injecting one ampoule of meglumine antimoniate intramuscularly every other day until clinical cure is demonstrated, while studying a series of 40 cutaneous leishmaniasis cases. Total dose used varied from 1,822.5 to 12,150mg of pentavalent antimony and total time of treatment varied from 3 to 10 weeks, with 86% efficacy. Thirty-six out of the 40 patients are still on follow-up with a mean time of 10.7 ± 7 months and a median of 9 months. No relapse or mucosal lesions have been noted so far. The schedule showed good tolerance and easy application and its efficacy was comparable to the officially recommended WHO schedule. Therefore, such a schedule represents a valuable alternative for the cases with high toxicicity to antimony or daily injections are an obstacle to the treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two mucocutaneous leishmaniasis cases resistant to therapy are reported here. After the failure of initial therapies (antimony, amphotericin B and/or pentamidine) patients received a low-dose schedule: one ampoule of meglumine antimoniate (405mg of pentavalent antimony [Sb v]) by intramuscular injection, three times a week until complete healing of the lesions. One patient was cured with a total of 30 ampoules in 10 weeks and the other received 36 ampoules in 12 weeks. Both remain clinically cured after one year of follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This study investigated the epidemiological and clinical profile of snakebite cases reported from 2007 to 2012 in the municipalities of the Curimataú region, State of Paraíba, in northeastern Brazil. Methods Data were collected from the Health Department of the State of Paraíba using the Injury Notification Information System data banks of the Health Ministry. Results A total of 304 snakebite cases were studied. The cases occurred most frequently from April to June. The genera Bothrops, Crotalus, and Micrurus were responsible for 74.6%, 6.2%, and 1.3% of cases, respectively. Snakebite cases predominated in males living in rural areas and between 10 and 19 years old. The highest incidence of bites occurred on the feet. The majority of the victims received medical assistance within 1 to 3h after being bitten. With regard to severity, 48% of the cases were classified as mild, 26% as moderate, and 2.6% as severe. Successful cures predominated, and no deaths were reported. The average antivenom ampoule dose used for the treatment in some snakebite cases was lower than that recommended by the Health Ministry. Conclusions Although our results show that Paraíba has a good level of medical care, there are serious deficiencies in recording snakebite information. These data indicate the need to improve the recording process for snakebite cases. Further training for health professionals seems to be necessary to optimize their skills in treating snakebite victims.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structure of the male reproductive tract was described in Uca uruguayensis Nobili, 1901, by using histological methods, scanning electron microscopy techniques, and stereoscopic observations of fresh material. The aim of this work was to establish the functional changes associated with sexual maturation. The morphology of the first (G1) and second (G2) pair of gonopods was described. The male reproductive tract consists of paired organs: testes, and tubular and convoluted vas deferens (VD) ending with a terminal ampoule (TA).The (VD) is composed of three parts: anterior (AVD), medial (MVD) and posterior (PVD). The AVD and MVD are lined by a single layer of cubical cells. The PVD epithelial cells are columnar with elongated nuclei. The terminal ampoule comprises four interconnecting chambers and is externally surrounded by connective tissue. The study of testes and vas deferens at different times along the year suggests that U. uruguayensis has a single and continuous reproductive season from December to March. The TA has not been described in other brachyurans and this structure is novel to Brachyura.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As part of a project to use the long-lived (T(1/2)=1200a) (166m)Ho as reference source in its reference ionisation chamber, IRA standardised a commercially acquired solution of this nuclide using the 4pibeta-gamma coincidence and 4pigamma (NaI) methods. The (166m)Ho solution supplied by Isotope Product Laboratories was measured to have about 5% Europium impurities (3% (154)Eu, 0.94% (152)Eu and 0.9% (155)Eu). Holmium had therefore to be separated from europium, and this was carried out by means of ion-exchange chromatography. The holmium fractions were collected without europium contamination: 162h long HPGe gamma measurements indicated no europium impurity (detection limits of 0.01% for (152)Eu and (154)Eu, and 0.03% for (155)Eu). The primary measurement of the purified (166m)Ho solution with the 4pi (PC) beta-gamma coincidence technique was carried out at three gamma energy settings: a window around the 184.4keV peak and gamma thresholds at 121.8 and 637.3keV. The results show very good self-consistency, and the activity concentration of the solution was evaluated to be 45.640+/-0.098kBq/g (0.21% with k=1). The activity concentration of this solution was also measured by integral counting with a well-type 5''x5'' NaI(Tl) detector and efficiencies computed by Monte Carlo simulations using the GEANT code. These measurements were mutually consistent, while the resulting weighted average of the 4pi NaI(Tl) method was found to agree within 0.15% with the result of the 4pibeta-gamma coincidence technique. An ampoule of this solution and the measured value of the concentration were submitted to the BIPM as a contribution to the Système International de Référence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seventeen patients proceeding from the municipality of Rio de Janeiro, Brazil presenting with the cutaneous ulcerative form of American leishmaniasis were treated with one ampoule of pentavalent antimony daily for 30 days. With this regimen the individuals doses varies greatly: from 3.8 mg/kg of body weight to 22.3 mg/kg. After five years, patients receiving either a smaller dose or a bigger one, showed the same therapeutic result: cutaneous scars and no mucosal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Local antibiotics may significantly improve the treatmentoutcome in bone infection without systemic toxicity. For impregnationof polymethylmethacrylate (PMMA), gentamicin, vancomycin and/orclindamycin are currently used. A new lipopeptid antibiotic,daptomycin, is a promising candidate for local treatment due to itsspectrum against staphylococci and enterococci (including multiresistantstrains), and concentration-dependent rapid bactericidalactivity. We investigated activity of antibiotic-loaded PMMA againstStaphylococcus epidermidis biofilms using an ultra-sensitive bacterialheat detection method (microcalorimetry).Methods: Staphylococcus epidermidis (strain RP62A, susceptibleto daptomycin, vancomycin and gentamicin) at concentration 106bacteria/ml was incubated with 2 g-PMMA block (Palacos, HeraeusMedical, Hanau, Germany) in 25 ml tryptic soy broth (TSB)supplemented with calcium. PMMA blocks were preloaded withdaptomycin, vancomycin and gentamicin each at 2 g/40 mg (= 100 mg/block) PMMA. After 72 h-incubation at 35 °C under static conditions,PMMA blocks were rinsed in phosphate-buffered solution (PBS) 5times and transferred in 4 ml-microcalorimetry ampoule filled with 1 mlTSB. Bacterial heat production, which is proportional to the quantityof biofilm on PMMA surface, was measured by isothermalmicrocalorimetry. The detection time was calculated as the time untilthe heat flow reached 20 microwatt.Results: Biomechanical properties did not differ between antibioticloadedand non-loaded PMMA blocks. The mean detection time (±standard deviation) of bacterial heat was 6.5 ± 0.4 h for PMMA withoutantibiotics (negative control), 13.5 ± 4.6 h for PMMA with daptomycin,14.0 ± 4.1 h for PMMA with vancomycin and 5.0 ± 0.4 h for PMMAwith gentamicin.Conclusion: Our data indicates that antibiotics at 2 g/40 mg PMMAdid not change the biomechanical properties of bone cement. Daptomycinand vancomycin were more active than gentamicin against S.epidermidis biofilms when all tested at 2 g/40 mg PMMA. In the nextstep, higher concentrations of daptomycin and their elution kineticneeds to be determined to optimize its antibiofilm activity before usingin the clinical setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The calorimetric experiments based on technique breaking ampoule were carried out by measuring of the heat of solution of alcohol in isotonic solution (NaCl 0.10 M) and alcohol in suspension of Sc at 298 K. From these data the enthalpy of interaction alcohol with suspension of Sc (DtrsH°) was calculate by Hess law. In this study, the results indicate that the enthalpy of interaction of aliphatic alcohol (C2-C8) with suspensions of Sc is a process exothermic and becomes more exothermic with increasing of -CH2 group of alcohol in range -1,14 to -4,0 kJ.mol-1. We concluded that enthalpy of interaction shows a linear relationship with increasing of alcohol's lipophilicity, in agreement with Traube's rule.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the decapods, the caridean Exhippolysmata oplophoroides has been described as a simultaneous protandric hermaphrodite, seeing that it presents a male initial stage followed by a hermaphrodite one in which it can function as male and as female. This work had the aims of characterizing the microscopical morphology of the male portion of the ovotestes gonads from E. oplophoroides, at the different development stages, identifying each cell from the germ lines during spermatogenesis, as well as describing the ultramorphology of spermatozoans in the terminal region of the vasa deferentia. Shrimps were collected in Ubatuba, north coast of São Paulo, and their male gonads and the ampoule were removed, fixed and processed according to histological routine and for scanning electron microscopy. The testicular portion is divided in lobes, inside which cells at the same stage of the spermatogenic cycle are observed, with prevalence of spermatogonia and spermatocytes at stages I, II and V of gonad development, whereas spermatids and spermatozoans are found at stages III and IV, respectively. Ultramorphology of the terminal portion of the vasa deferentia exhibits mature aflagellated spike-shaped spermatozoans, encased in secretion and between membrane foldings that will constitute the spermatophores. Despite presenting reproductive characteristics common to other decapods. E. oplophoroides shows spermatozoans as well as spermatophore with typical morphology, which is important for its identification and taxonomy. Further, this species showed polysaccharide secretions where the spermatozoa are immerse as far as the testicular portion, which could have a roe in their transport and nutrition as well as spermatophore constitution and/or fixation; differently, other caridean species begin spermatophore formation during the passage of the gametes through the vasa deferentia. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objectives: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. Contents: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. Conclusions: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important. © 2011 Elsevier Editora Ltda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 mu g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO2 into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO2 can be provided in four different ways to the versatile gas interface. As a primary method. CO2 is delivered in glass or quartz ampoules. In this case, the CO2 is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO2 is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO2 is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are many steps involved in developing a drug candidate into a formulated medicine and many involve analysis of chemical interaction or physical change. Calorimetry is particularly suited to such analyses as it offers the capacity to observe and quantify both chemical and physical changes in virtually any sample. Differential scanning calorimetry (DSC) is ubiquitous in pharmaceutical development, but the related technique of isothermal calorimetry (IC) is complementary and can be used to investigate a range of processes not amenable to analysis by DSC. Typically, IC is used for longer-term stability indicating or excipient compatibility assays because both the temperature and relative humidity (RH) in the sample ampoule can be controlled. However, instrument design and configuration, such as titration, gas perfusion or ampoule-breaking (solution) calorimetry, allow quantification of more specific values, such as binding enthalpies, heats of solution and quantification of amorphous content. As ever, instrument selection, experiment design and sample preparation are critical to ensuring the relevance of any data recorded. This article reviews the use of isothermal, titration, gas-perfusion and solution calorimetry in the context of pharmaceutical development, with a focus on instrument and experimental design factors, highlighted with examples from the recent literature. © 2011 Elsevier B.V.