7 resultados para ammeter
Resumo:
Workplace aggression is a factor that shapes the interaction between individuals and their work environment and produces many undesirable outcomes, sometimes introducing heavy costs for organizations. Only through a comprehensive understanding of the genesis of workplace aggression is possible to develop strategies and interventions to minimize its nefarious effects. The existent body of knowledge has already identified several individual, situational and contextual antecedents of workplace aggression, although this is a research area where significant gaps occur and many issues were still not addressed Dupré and Barling (2006). According to Baron and Neuman (1998) one of these predictors is organizational change, since certain changes in the work environment (e.g., changes in management) can lead to increased aggression. This paper intends to contribute to workplace aggression research by studying its relationship with organizational change, considering a moderating role of political behaviors and organizational cynicism (Ammeter et al., 2002, Ferris et al., 2002). The literature review suggests that mediators and moderators that intervene in the relationships between workplace aggression and its antecedents are understudied topics. James (2005) sustains that organizational politics is related to cynicism and the empirical research of Miranda (2008) has identified leadership political behavior as an antecedent of cynicism but these two variables were not yet investigated regarding their relationship with workplace aggression. This investigation was operationalized using several scales including the Organizational Change Questionnaire-climate of change, processes, and readiness (Bouckenooghe, Devos and Broeck, 2009), a Workplace Aggression Scale (Vicente and D’Oliveira, 2008, 2009, 2010), an Organizational Cynicism Scale (Wanous, Reichers and Austin, 1994) and a Political Behavior Questionnaire (Yukl and Falbe, 1990). Participants representing a wide variety of jobs across many organizations were surveyed. The results of the study and its implications will be presented and discussed. This study contribution is also discussed in what concerns organizational change practices in organizations.
Resumo:
Workplace aggression is a factor that shapes the interaction between individuals and their work environment and produces many undesirable outcomes, sometimes introducing heavy costs for organizations. Only through a comprehensive understanding o f the genesis of workplace aggression is possible to develop strategies and interventions to minimize its nefarious effects. The existent body of knowledge has already identified several individual, situational and contextual antecedents of workplace aggr ession, although this is a research area where significant gaps occur and many issues were still not addressed (Dupré & Barling, 2006). According to Neuman and Baron (1998) one of these predictors is organizational change, since certain changes in the work environment (e.g., changes in management) can lead to increased aggression. This paper intends to contribute to workplace aggression research by studying its relationship with organizational change, considering the mediation role of political behaviors an d organizational cynicism (Ammeter, Douglas, Gardner, Hochwarter, & Ferris, 2002). The literature review suggests that mediators and moderators that intervene in the relationships between workplace aggression and its antecedents are understudied topics. Ja mes (2005) sustains that organizational politics is related to cynicism and the empirical research of Miranda (2008) has identified leadership political behavior as an antecedent of cynicism but these two variables were not yet investigated regarding their relationship with workplace aggression. This investigation was operationalized using several scales including the Organizational Change Questionnaire - climate of change, processes, and readiness (Bouckenooghe, Devos, & Broeck, 2009), a Workplace Aggressio n Scale (Vicente, 2008, 2009), an Organizational Cynicism Scale (Wanous, Reichers, & Austin, 1994) and a Political Behavior Questionnaire (Yukl & Falbe, 1990). Participants representing a wide variety of jobs across many organizations were surveyed. The r esults of the study and its implications will be presented and discussed. This study contribution is also discussed in what concerns organizational change practices in organizations.
Resumo:
Remote laboratories are an emergent technological and pedagogical tool at all education levels, and their widespread use is an important part of their own improvement and evolution. This paper describes several issues encountered on laboratorial classes, on higher education courses, when using remote laboratories based on PXI systems, either using the VISIR system or an alternate in-house solution. Three main issues are presented and explained, all reported by teachers, that gave support to students' use of remote laboratories. The first issue deals with the need to allow students to select the actual place where an ammeter is to be inserted on electric circuits, even incorrectly, therefore emulating real-world difficulties. The second one deals with problems with timing when several measurements are required at short intervals, as in the discharge cycle of a capacitor. In addition, the last issue deals with the use of a multimeter in dc mode when reading ac values, a use that collides with the lab settings. All scenarios are presented and discussed, including the solution found for each case. The conclusion derived from the described work is that the remote laboratories area is an expanding field, where practical use leads to improvement and evolution of the available solutions, requiring a strict cooperation and information-sharing between all actors, i.e., developers, teachers, and students.
Resumo:
Remote Laboratories are an emergent technological and pedagogical tool at all education levels, and their widespread use is an important part of their own improvement and evolution. This paper describes several issues encountered on laboratorial classes, on higher education courses, when using remote laboratories based on PXI systems, either using the VISIR system or an alternate in-house solution. Three main issues are presented and explained, all reported by teachers that gave support to students use of remote laboratories. The first issue deals with the need to allow students to select the actual place where an ammeter is to be inserted on electric circuits, even incorrectly, therefore emulating real world difficulties. The second one deals with problems with timing when several measurements are required at short intervals, as in the discharge cycle of a capacitor. And the last issue deals with the use of a multimeter in DC mode when reading AC values, a use that collides with the lab settings. All scenarios are presented and discussed including the solution found for each case. The conclusion derived from the described work is that the remote laboratories area is an expanding field, where practical use leads to improvement and evolution of the available solutions, requiring a strict cooperation and information sharing between all actors, i.e. developers, teachers and students.
Electrochemical noise analysis of bioleaching of bornite (Cu5FeS4) by Acidithiobacillus ferrooxidans
Resumo:
Electrochemical noise (EN) is a generic term describing the phenomenon of spontaneous fluctuations of potential or current noise of electrochemical systems. Since this technique provides a non-destructive condition for investigating corrosion processes, it can be useful to study the electrochemical oxidation of mineral sulfides by microorganisms, a process known as bacterial leaching of metals. This technique was utilized to investigate the dissolution of a bornite electrode in the absence (first 79 h) and after the addition of Acidithiobacillus ferrooxidans (next 113 h) in salts mineral medium at pH 1.8, without addition of the energy source (Fe2+ ions) for this chemolithotrophic bacterium. Potential and current noise data have been determined simultaneously with two identical working bornite electrodes which were linked by a zero resistance ammeter (ZRA). The mean potential, E-coup, coupling current, I-coup, standard deviations of potential and current noise fluctuations and noise resistance, R-n, have been obtained for coupled bornite electrodes. Noise measurements were recorded twice a day in an unstirred solution at 30 degrees C. Significant changes in these parameters were observed when the A. ferrooxidans suspension was added, related with bacterial activity on reduced species present in the sulfide moisture (Fe2+, S2-). ENA was a suitable tool for monitoring the changes of the corrosion behavior of bornite due to the presence of bacterium. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
In the treatment of copper ores by hydro-electro-metallurgical methods, not only is copper deposited, but other metals are also dissolved. In practice it has been found* that iron, under certain conditions, causes the copper to deposit on the cathode as a nonadherent precipitate and also that the iron in solution causes a great decrease in current efficiency, especially when the electrolysis is conducted by operating with a higher current density at the cathode than at the anode. The present investigation deals with the effects of the two valences of iron on the current efficiency and endeavors to determine whether or not there is a ratio of the two at which point the efficiency becomes zero or approaches it.
Resumo:
Instrument transformers serve an important role in the protection and isolation of AC electrical systems for measurements of different electrical parameters like voltage, current, power factor, frequency, and energy. As suggested by name these transformers are used in connection with suitable measuring instruments like an ammeter, wattmeter, voltmeter, and energy meters. We have seen how higher voltages and currents are transformed into lower magnitudes to provide isolation between power networks, relays, and other instruments. Reducing transient, suppressing electrical noises in sensitive devices, standardization of instruments and relays up to a few volts and current. Transformer performance directly affects the accuracy of power system measurements and the reliability of relay protection. We classified transformers in terms of purpose, insulating medium, Voltage ranges, temperature ranges, humidity or environmental effect, indoor and outdoor use, performance, Features, specification, efficiency, cost analysis, application, benefits, and limitations which enabled us to comprehend their correct use and selection criteria based on our desired requirements. We also discussed modern Low power instrument transformer products that are recently launched or offered by renowned companies like Schneider Electric, Siemens, ABB, ZIV, G&W etc. These new products are innovations and problem solvers in the domain of measurement, protection, digital communication, advance, and commercial energy metering. Since there is always some space for improvements to explore new advantages of Low power instrument transformers in the domain of their wide linearity, high-frequency range, miniaturization, structural and technological modification, integration, smart frequency modeling, and output prediction of low-power voltage transformers.