775 resultados para age, astigmatism, defocus, visual acuity
Resumo:
PURPOSE: To investigate how distance visual acuity in the presence of defocus and astigmatism is affected by age and whether aberration properties of young and older eyes can explain any differences. METHODS: Participants were 12 young adults (mean [±SD] age, 23 [±2] years) and 10 older adults (mean [±SD] age, 57 [±4] years). Cyclopleged right eyes were used with 4-mm effective pupil sizes. Thirteen blur conditions were used by adding five spherical lens conditions (-1.00 diopters [D], -0.50 D, plano/0.00 D, +0.50 D, and +1.00 D) and adding two cross-cylindrical lenses (+0.50 DS/-1.00 DC and +1.00 D/-2.00 DC, or 0.50 D and 1.00 D astigmatism) at four negative cylinder axes (45, 90, 135, and 180 degrees). Targets were single lines of high-contrast letters based on the Bailey-Lovie chart. Successively smaller lines were read until a participant could no longer read any of the letters correctly. Aberrations were measured with a COAS-HD Hartmann-Shack aberrometer. RESULTS: There were no significant differences between the two age groups. We estimated that 70 to 80 participants per group would be needed to show significant effects of the trend of greater visual acuity loss for the young group. Visual acuity loss for astigmatism was twice that for defocus of the same magnitude of blur strength (0.33 logMAR [logarithm of the minimum angle of resolution]/D compared with 0.18 logMAR/D), contrary to the geometric prediction of similar loss. CONCLUSIONS: Any age-related differences in visual acuity in the presence of defocus and astigmatism were swamped by interparticipant variation.
Resumo:
Abstract Purpose: To determine how high and low contrast visual acuities are affected by blur caused by crossed-cylinder lenses. Method: Crossed-cylinder lenses of power zero (no added lens), +0.12 DS/-0.25 DC, +0.25 DS/-0.50 DC and +0.37/-0.75 DC were placed over the correcting lenses of the right eyes of eight subjects. Negative cylinder axes used were 15-180 degrees in 15 degree step for the two higher crossed-cylinders and 30-180 degrees in 30 degree steps for the lowest crossed cylinder. Targets were single lines of letters based on the Bailey-Lovie chart. Successively smaller lines were read until the subject could not read any of the letters correctly. Two contrasts were used: high (100%) and low (10%). The screen luminance of 100 cd/m2, together with the room lighting, gave pupil sizes of 4.5 to 6 mm. Results: High contrast visual acuities were better than low contrast visual acuities by 0.1 to 0.2 log unit (1 to 2 chart lines) for the no added lens condition. Based on comparing the average of visual acuities for the 0.75 D crossed-cylinder with the best visual acuity for a given contrast and subject, the rates of change of visual acuity per unit blur strength were similar for high contrast (0.34± 0.05 logMAR/D) and low contrast (0.37± 0.09 logMAR/D). There were considerable asymmetry effects, with the average loss in visual acuity across the two contrasts and the 0.50D/0.75 D crossed-cylinders doubling between the 165± and 60± negative cylinder axes. The loss of visual acuity with 0.75 D crossed-cylinders was approximately twice times that occurring for defocus of the same blur strength. Conclusion: Small levels of crossed-cylinder blur (≤0.75D) produce losses in visual acuity that are dependent on the cylinder axis. 0.75 D crossed-cylinders produce losses in visual acuity that are twice those produced by defocus of the same blur strength.
Resumo:
Aim: To evaluate the influence of socio-economic factors on visual acuity (VA) at presentation in exudative age- related macular degeneration (AMD). Methods: The medical records of all consecutive patients with newly diagnosed exudative AMD examined at the Ophthalmology Departments of Grampian University Hospitals-NHS Trust, Aberdeen, and Gartnavel General Hospital, Glasgow, between July 2004 and June 2005, were reviewed. Demographics, duration of symptoms, VA in study and fellow eye, exudative AMD characteristics, status of fellow eye and patient home address, used to determine the Scottish Index of Multiple Deprivation (SIMD) score, were recorded. The effect of these parameters on VA at presentation was investigated using general linear modelling. Results: Two-hundred and forty patients (median age 79 years) were included in this study; 44 (18.3%) belonged to the lowest 20% SIMD score (most deprived). Age and location and type of the choroidal neovascular- isation were statistically significantly associated with VA at presentation (p = 0.003, p
Resumo:
OBJECTIVE: To evaluate the impact of age, various forms of cataract, and visual acuity on whole-field scotopic sensitivity screening for glaucoma in a rural population. DESIGN: Clinic-based study with population-based recruitment. SETTING: Jin Shan Township near Taipei, Taiwan. SUBJECTS: Three hundred forty-six residents (ages, > or = 40 years) of Jin Shan Township. INTERVENTIONS: Whole-field scotopic testing, ophthalmoscopy with dilation of the pupils, cataract grading against photographic standards, and screening visual field testing in a random one-third subsample. MAIN OUTCOME MEASURES: Whole-field scotopic sensitivity (in decibels) and diagnostic status as a case of glaucoma, glaucoma suspect, or normal. RESULTS: Participants in Jin Shan Township did not differ significantly in the rate of blindness, low visual acuity, or family history of glaucoma from a random sample of nonrespondents. Scotopic sensitivity testing detected 100% (6/6) of subjects with open-angle glaucoma at a specificity of 80.2%. The mean +/- SE scotopic sensitivity for six subjects with open-angle glaucoma (32.78 +/- 1.51 dB) differed significantly from that of 315 normal individuals (38.51 +/- 0.22 dB), when adjusted for age and visual acuity (P = .05, t test). With linear regression modeling, factors that correlated significantly with scotopic sensitivity were intraocular pressure, screening visual field, best corrected visual acuity, presence of cortical cataract, and increasing age. CONCLUSIONS: Although cataract affects the whole-field scotopic threshold, it appears that scotopic testing may be of value in field-based screening for glaucoma.
Resumo:
Differences in treatment responses to ranibizumab injections observed within trials involving monthly (MARINA and ANCHOR studies) and quarterly (PIER study) treatment suggest that an individualized treatment regimen may be effective in neovascular age-related macular degeneration. In the present study, a drug and disease model was used to evaluate the impact of an individualized, flexible treatment regimen on disease progression.
Resumo:
We evaluated the near visual acuity of 40 dentists and its improvement by using different magnification devices. The acuity was tested with miniaturized E-optotype tests on a negatoscope under the following conditions: 1. natural visual acuity, 300 mm; 2. single lens loupe, 2×, 250 mm; 3. Galilean loupe, 2.5×, 380 mm; and 4. Keplerian loupe, 4.3×, 400 mm. In part 1, the influence of the magnification devices was investigated for all dentists. The Keplerian loupe obtained the highest visual acuity (4.64), followed by the Galilean loupe (2.43), the single lens loupe (1.42), and natural visual acuity (1.19). For part 2, the dentists were classified according to their age (?40 years). The younger dentists' group achieved a significantly higher visual acuity with all magnification devices (p<0.001). For part 3, the dentists were grouped according to their natural visual acuity. The group with the higher natural visual acuity achieved significantly higher visual acuity with all magnification devices than did the group of dentists with the lower natural visual acuity (p<0.01). It can be concluded that near visual acuity varies highly between individuals and decreases during the lifetime. Independent of age or natural vision, visual acuity can be significantly improved by using magnification devices.
Resumo:
Purpose To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. Methods The Northern Ireland Childhood Errors of Refraction (NICER) study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. Results Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. Conclusions Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.
Resumo:
Purpose.: To determine photopic and mesopic distance high-contrast visual acuity (HC-VA) and low-contrast visual acuity (LC-VA) in eyes with early age-related macular degeneration (AMD). Methods.: Measurements were made in 22 subjects with early AMD and 28 healthy control subjects. Inclusion criteria included a photopic HC-VA of 20/25 or better. Distance VA was measured using HC (96%) and LC (10%) Bailey-Lovie logMAR letter charts under photopic (85 cd/m2) and mesopic (0.1–0.2 cd/m2) luminance conditions. Results.: Mean mesopic distance HC-VA and LC-VA were significantly worse (0.1 logMAR and 0.28 logMAR, respectively) in the early AMD group than in the control group. Under mesopic conditions, the mean difference between LC-VA and HC-VA was significantly greater in the early AMD (0.45 logMAR) than the control group (0.27 logMAR). Mean differences between mesopic versus photopic HC-VA and mesopic versus photopic LC-VA were significantly greater in the early AMD than the control group (0.13 and 0.32 logMAR of difference between the means, respectively). Sensitivity and specificity were significantly greater for mesopic LC-VA than for mesopic HC-VA (Receiver Operating Characteristics, area under the curve [AUC], 0.94 ± 0.030 and 0.76 ± 0.067, respectively). AUC values for photopic HC-VA and LC-VA were below 0.70. Conclusions.: Visual acuity testing under low luminance conditions emerged as an optimal quantitative measure of retinal function in early AMD.
Resumo:
We propose in this work a model for describing visual acuity (VV) as a function of defocus and pupil diameter. Although the model is mainly based on geometrical optics, it also incorporates nongeometrical effects phenomenologically. Compared to similar visual acuity models, the proposed one considers the effect of astigmatism and the variability of best corrected VV among individuals; it also takes into account the accommodation and the “tolerance to defocus,” the latter through a phenomenological parameter. We have fitted the model to the VV data provided in the works of Holladay et al. and Peters, showing the ability of this model to accurately describe the variation of VV against blur and pupil diameter. We have also performed a comparison between the proposed model and others previously published in the literature. The model is mainly intended for use in the design of ophthalmic compensations, but it can also be useful in other fields such as visual ergonomics, design of visual tests, and optical instrumentation.
Resumo:
PURPOSE. To assess whether there are any advantages of binocular over monocular vision under blur conditions. METHODS. We measured the effect of defocus, induced by positive lenses, on the pattern reversal Visual Evoked Potential (VEP) and on visual acuity (VA). Monocular (dominant eye) and binocular VEPs were recorded from thirteen volunteers (average age: 28±5 years, average spherical equivalent: -0.25±0.73 D) for defocus up to 2.00 D using positive powered lenses. VEPs were elicited using reversing 10 arcmin checks at a rate of 4 reversals/second. The stimulus subtended a circular field of 7 degrees with 100% contrast and mean luminance 30 cd/m2. VA was measured under the same conditions using ETDRS charts. All measurements were performed at 1m viewing distance with best spectacle sphero-cylindrical correction and natural pupils. RESULTS. With binocular stimulation, amplitudes and implicit times of the P100 component of the VEPs were greater and shorter, respectively, in all cases than for monocular stimulation. Mean binocular enhancement ratio in the P100 amplitude was 2.1 in-focus, increasing linearly with defocus to be 3.1 at +2.00 D defocus. Mean peak latency was 2.9 ms shorter in-focus with binocular than for monocular stimulation, with the difference increasing with defocus to 8.8 ms at +2.00 D. As for the VEP amplitude, VA was always better with binocular than with monocular vision, with the difference being greater for higher retinal blur. CONCLUSIONS. Both subjective and electrophysiological results show that binocular vision ameliorates the effect of defocus. The increased binocular facilitation observed with retinal blur may be due to the activation of a larger population of neurons at close-to-threshold detection under binocular stimulation.
Resumo:
Visual acuities at the time of referral and on the day before surgery were compared in 124 patients operated on for cataract in Vaasa Central Hospital, Finland. Preoperative visual acuity and the occurrence of ocular and general disease were compared in samples of consecutive cataract extractions performed in 1982, 1985, 1990, 1995 and 2000 in two hospitals in the Vaasa region in Finland. The repeatability and standard deviation of random measurement error in visual acuity and refractive error determination in a clinical environment in cataractous, pseudophakic and healthy eyes were estimated by re-examining visual acuity and refractive error of patients referred to cataract surgery or consultation by ophthalmic professionals. Altogether 99 eyes of 99 persons (41 cataractous, 36 pseudophakic and 22 healthy eyes) with a visual acuity range of Snellen 0.3 to 1.3 (0.52 to -0.11 logMAR) were examined. During an average waiting time of 13 months, visual acuity in the study eye decreased from 0.68 logMAR to 0.96 logMAR (from 0.2 to 0.1 in Snellen decimal values). The average decrease in vision was 0.27 logMAR per year. In the fastest quartile, visual acuity change per year was 0.75 logMAR, and in the second fastest 0.29 logMAR, the third and fourth quartiles were virtually unaffected. From 1982 to 2000, the incidence of cataract surgery increased from 1.0 to 7.2 operations per 1000 inhabitants per year in the Vaasa region. The average preoperative visual acuity in the operated eye increased by 0.85 logMAR (in decimal values from 0.03to 0.2) and in the better eye 0.27 logMAR (in decimal values from 0.23 to 0.43) over this period. The proportion of patients profoundly visually handicapped (VA in the better eye <0.1) before the operation fell from 15% to 4%, and that of patients less profoundly visually handicapped (VA in the better eye 0.1 to <0.3) from 47% to 15%. The repeatability visual acuity measurement estimated as a coefficient of repeatability for all 99 eyes was ±0.18 logMAR, and the standard deviation of measurement error was 0.06 logMAR. Eyes with the lowest visual acuity (0.3-0.45) had the largest variability, the coefficient of repeatability values being ±0.24 logMAR and eyes with a visual acuity of 0.7 or better had the smallest, ±0.12 logMAR. The repeatability of refractive error measurement was studied in the same patient material as the repeatability of visual acuity. Differences between measurements 1 and 2 were calculated as three-dimensional vector values and spherical equivalents and expressed by coefficients of repeatability. Coefficients of repeatability for all eyes for vertical, torsional and horisontal vectors were ±0.74D, ±0.34D and ±0.93D, respectively, and for spherical equivalent for all eyes ±0.74D. Eyes with lower visual acuity (0.3-0.45) had larger variability in vector and spherical equivalent values (±1.14), but the difference between visual acuity groups was not statistically significant. The difference in the mean defocus equivalent between measurements 1 and 2 was, however, significantly greater in the lower visual acuity group. If a change of ±0.5D (measured in defocus equivalents) is accepted as a basis for change of spectacles for eyes with good vision, the basis for eyes in the visual acuity range of 0.3 - 0.65 would be ±1D. Differences in repeated visual acuity measurements are partly explained by errors in refractive error measurements.
Resumo:
PURPOSE. To investigate the methods used in contemporary ophthalmic literature to designate visual acuity (VA). METHODS. Papers in all 2005 editions of five ophthalmic journals were considered. Papers were included if (1) VA, vision, or visual function was mentioned in the abstract and (2) if the study involved age-related macular degeneration, cataract, or refractive surgery. If a paper was selected on the basis of its abstract, the full text of the paper was examined for information on the method of refractive correction during VA testing, type of chart used to measure VA, specifics concerning chart features, testing protocols, and data analysis and means of expressing VA in results. RESULTS. One hundred twenty-eight papers were included. The most common type of charts used were described as logMAR-based. Although most (89.8%) of the studies reported on the method of refractive correction during VA testing, only 58.6% gave the chart design, and less than 12% gave any information whatsoever on chart features or measurement procedures used. CONCLUSIONS. The methods used and the approach to analysis were rarely described in sufficient detail to allow others to replicate the study being reported. Sufficient detail should be given on VA measurement to enable others to duplicate the research. The authors suggest that charts adhering to Bailey-Lovie design principles always be used to measure vision in prospective studies and their use encouraged in clinical settings. The distinction between the terms logMAR, an acuity notation, and Bailey-Lovie or ETDRS as chart types should be adhered to more strictly. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
BACKGROUND: The accuracy and impact on service uptake of early examination after cataract surgery is not known. DESIGN: Prospective cohort study. PARTICIPANTS: Cataract patients in rural Indonesia. METHODS: Visual acuity was measured preoperatively, 1day, 1-3, 4-6 and >12weeks after surgery, and 6-8months postoperatively at an outreach examination. Acceptance of second-eye surgery and spectacles was evaluated. MAIN OUTCOME MEASURE: Presenting visual acuity in the operated eye. RESULTS: Among 241 subjects (extracapsular surgery 84%), examinations at 1day, 1-3, 4-6 and >12weeks and 6-8months were completed for 100% (241), 90.9% (219), 67.6% (163), 22.0% (53) and 80.0% (193), respectively. Among subjects at the final examination (mean age 65.8±10.6years, 51.8% male), 73.6% had bilateral preoperative presenting visual acuity≤6/60. By 4-6weeks, the proportion with good (≥6/18) or poor (≤6/60) visual acuity did not differ significantly from the final examination. Among 49 persons accepting free second-eye surgery, 69.4% (34) and 16.3% (8) returned to clinic at 4-6 and >12weeks, respectively. Among 131 patients (67.9%) paying US$7 for glasses, 94 (71.8%) and 30 (22.9%) attended 4- to 6- and >12-week examinations, respectively. CONCLUSION: Even with large-incision surgery, early assessment of postoperative vision is representative of final vision, and may help deliver postoperative services to more of those needing them. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
OBJECTIVES This study examined the near visual acuity of dentists in relation to age and magnification under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were performed in posterior teeth of a dental phantom head in a simulated clinical setting (dental chair, operating lamp, dental mirror). The visual acuity of 40 dentists was measured under the following conditions: (1) natural visual acuity, distance of 300 mm; (2) natural visual acuity, free choice of distance; (3) Galilean loupes, magnification of ×2.5; (4) Keplerian loupes, ×4.3; (5) operating microscope, ×4, integrated light; (6) operating microscope, ×6.4, integrated light. RESULTS The visual acuity varied widely between individuals and was significantly lower in the group ≥40 years of age (p < 0.001). Significant differences were found between all tested conditions (p < 0.01). Furthermore, a correlation between visual acuity and age was found for all conditions. The performance with the microscope was better than with loupes even with comparable magnification factors. Some dentists had a better visual acuity without optical aids than others with Galilean loupes. CONCLUSIONS Near visual acuity under simulated clinical conditions varies widely between individuals and decreases throughout life. Visual deficiencies can be compensated for with optical aids. CLINICAL RELEVANCE Newly developed miniaturized vision tests have allowed, in a clinically relevant way, to evaluate the influence of magnification and age on the near visual acuity of dentists.