954 resultados para advanced oxidation protein product


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the effect of aerobic training in the context of antioxidant supplementation on systemic oxidative stress and leukocytes heat shock protein (Hsp)72 expression in the elderly. DESIGN: Sixteen septuagenarians (8 males and 8 females, mean age 74.6) were supplemented with Vitamin C and E (respectively 500 and 100mg per day) and randomly assigned either to sedentary (AS) or individualized aerobically trained (AT) group for 8 weeks. METHODS: Plasma Vitamin C and E concentrations and aerobic fitness, as well as resting and post graded exercise (GXT) Hsp72 expression in leukocytes, plasma levels of thiobarbituric acid reactive substances (TBARS) and advanced oxidation protein product (AOPP) were measured pre and post training / supplementation. RESULTS: At the end of the intervention, the two groups showed a significant increase in resting plasma vitamin C and E (approximately 50 and 20% increase respectively) and a significant decrease in both resting and post GXT plasma TBARS and AOPP (approximately 25 and 20% decrease respectively). These changes were of similar magnitude in the two groups. The reduced oxidative stress was concomitant with a 15% decreased expression of Hsp72 in monocytes and granulocytes in both groups. CONCLUSION: This study provides evidence that in elderly, increased concentration of antioxidant vitamins C and E is associated with a reduction in oxidative stress and leukocytes Hsp72. In this context, 8 weeks of aerobic training has no impact on oxidative stress or leukocytes Hsp72 expression in elderly people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate nitric oxide levels, lipid peroxidation, protein oxidation and glutathione reductase activity in serum of dogs experimentally infected by Ehrlichia canis. Banked serum samples of dogs divided into two groups were used: negative control (n=5) and infected by E. canis (n=5). The concentration of nitrite/nitrate (NOx), lipid peroxidation (TBARS), advanced oxidation protein products (AOPP), and glutathione reductase (GR) activity in sera were evaluated. Samples were collected on days 0, 3, 6, 18 and 30 post-infection (PI). NOx and TBARS levels were significantly (P<0.05) higher in the infected group at 18 and 30 days PI, as well as AOPP levels at 30 days PI when compared to samples from control group. The GR activity was significant (P<0.05) increased in serum of dogs infected by E. canis on days 18 and 30 PI. Based on the increased levels of NOx, TBARS, AOPP and GR activity we concluded that dogs experimentally infected by E. canis develop a state of redox imbalance and that these changes might be involved in the pathophysiology of the disease. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gasoline oxygenates (MTBE, methyl tert-butyl ether; DIPE, di-isopropyl ether; ETBE, ethyl tert-butyl ether; TAME, tert-amyl ether) are added to gasoline to boost octane and enhance combustion. The combination of large scale use, high water solubility and only minor biodegradability has now resulted in a significant gasoline oxygenate contamination occurring in surface, ground, and drinking water systems. Combination of hydroxyl radical formation and the pyrolytic environment generated by ultrasonic irradiation (665 kHz) leads to the rapid degradation of MTBE and other gasoline oxygenates in aqueous media. ^ The presence of oxygen promotes the degradation processes by rapid reaction with carbon centered radicals indicating radical processes involving O 2 are significant pathways. A number of the oxidation products were identified. The formation of products (alcohols, ketones, aldehydes, esters, peroxides, etc) could be rationalized by mechanisms which involve hydrogen abstraction by OH radical and/or pyrolysis to form carboncentered radicals which react with oxygen and follow standard oxidation chain processes. ^ The reactions of N-substituted R-triazolinediones (RTAD; R = CH 3 or phenyl) have attracted considerable interest because they exhibit a number of unusual mechanistic characteristics that are analogous to the reactions of singlet oxygen (1O2) and offer an easy way to provide C-N bond(s) formation. The reactions of triazolinedione with olefins have been widely studied and aziridinium imides are generally accepted to be the reactive intermediates. ^ We observed the rapid formation of an unusual intermediate upon mixing tetracyclopropylethylene with 4-methyl-1,2,4-triazoline-3,5-dione in CDCl 3. Detailed characterization by NMR (proton, 13C, 2-D NMRs) indicates the intermediate is 5,5,6,6-tetracyclopropyl-3-methyl-5,6-dihydro-oxazolo[3,2- b][1,2,4]-triazolium-2-olate. Such products are extremely rare and have not been studied. Upon warming the intermediate is converted to 2 + 2 diazetidine (major) and ene product (minor). ^ To further explore the kinetics and dynamics of the reaction activation energies were obtained using Arrhenius plots. Activation energies for the formation of the intermediate from reactants, and 2+2 adduct from the intermediate were determined as 7.48 kcal moll and 19.8 kcal mol−1 with their pre-exponential values of 2.24 × 105 dm 3 mol−1 sec−1 and 2.75 × 108 sec−1, respectively, meaning net slow reactions because of low pre-exponential values caused by steric hindrance. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ingestion of arsenic from contaminated water is a serious problem and affects the health of more than 100 million people worldwide. Traditional water purification technologies are generally not effective or cost prohibitive for the removal of arsenic to acceptable levels (≤10 ppb). Current multi-step arsenic removal processes involve oxidation, precipitation and/or adsorption. Advanced Oxidation Technologies (AOTs) may be attractive alternatives to existing treatments. The reactions of inorganic and organic arsenic species with reactive oxygen species were studied to develop a fundamental mechanistic understanding of these reactions, which is critical in identifying an effective and economical technology for treatment of arsenic contaminated water. ^ Detailed studies on the conversion of arsenite in aqueous media by ultrasonic irradiation and TiO2 photocatalytic oxidation (PCO) were conducted, focusing on the roles of hydroxyl radical and superoxide anion radical formed during the irradiation. ·OH plays the key role, while O2 -· has little or no role in the conversion of arsenite during ultrasonic irradiation. The reaction of O2-· does not contribute in the rapid conversion of As(III) when compared to the reaction of As(III) with ·OH radical during TiO2 PCO. Monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA) are readily degraded upon TiO2 PCO. DMA is oxidized to MMA as the intermediate and arsenate as the final product. For dilute solutions, TiO2 also may be applicable as an adsorbent for direct removal of arsenic species, namely As(III), As(V), MMA and DMA, all of which are strongly adsorbed, thus eliminating the need for a multi-step treatment process. ^ Phenylarsonic acid (PA) was subjected to gamma radiolysis under hydroxyl radical generating conditions, which showed rapid degradation of PA. Product analysis and computational calculation both indicate the arsenate group is an ortho, para director. Our results indicate · OH radical mediated processes should be effective for the remediation of phenyl substituted arsonic acids. ^ While hydroxyl radical generating methods, specifically AOTs, appear to be promising methods for the treatment of a variety of arsenic compounds in aqueous media, pilot studies and careful economic analyses will be required to establish the feasibility of AOTs applications in the removal of arsenic. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe the status of oxidative stress and antioxidant biomarkers and their association with metabolic and body composition components of HIV-lipodystrophy syndrome. In a cross-sectional study of blood samples from HIV-infected men with lipodystrophy syndrome (HIV+LIPO+ = 10), HIV-infected men without lipodystrophy syndrome (HIV+LIPO- = 22), and healthy subjects (control = 12), the following oxidative stress biomarkers were analyzed: total hydroperoxide, thiobarbituric acid reactive substances (TBARS), and advanced oxidation protein products (AOPP). In addition, antioxidant biomarkers, including total glutathione, uric acid, alpha-tocopherol, and metabolic components were tested. Dual-energy x-ray absorciometry (DXA) was used to measure the fat mass. The duration of HIV infection and the duration and type of highly active antiretroviral therapy were similar between the two HIV-infected groups. Higher levels of total hydroperoxide were observed in the HIV+LIPO+ (50 +/- 33 H(2)O(2)/L) group compared to the HIV+LIPO-(19 +/- 13 H(2)O(2)/L) and control (5 +/- 5 H(2)O(2)/L) groups (p < 0.05). Similarly, higher levels of AOPP were observed in the HIV+LIPO+ (326 +/- 173 mu mol/L) group compared to the HIV+LIPO- (105 +/- 92 mu mol/L) and control groups (80 +/- 20 mu mol/L) (p < 0.05). Total hydroperoxide significantly correlated with insulin serum levels in the HIV+LIPO+ (r = 0.47, p < 0.05) and HIV+LIPO- groups (r = 0.29, p < 0.05), while AOPP significantly correlated with insulin serum levels in the HIV+LIPO+ (r = 0.73, p < 0.05) and HIV+LIPO- (r = 0.54, p < 0.05) groups. Therefore, higher lipid and protein oxidation were found in HIV-infected patients with lipodystrophy syndrome, and both were associated with insulin levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Química e Bioquímica pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxalic and oxamic acids are the ultimate and more persistent by-products of the degradation of N-aromatics by electrochemical advanced oxidation processes (EAOPs). In this paper, the kinetics and oxidative paths of these acids have been studied for several EAOPs using a boron-doped diamond (BDD) anode and a stainless steel or an air-diffusion cathode. Anodic oxidation (AO-BDD) in the presence of Fe2+ (AO-BDD-Fe2+) and under UVA irradiation (AO-BDD-Fe2+-UVA), along with electro-Fenton (EF-BDD), was tested. The oxidation of both acids and their iron complexes on BDD was clarified by cyclic voltammetry. AO-BDD allowed the overall mineralization of oxalic acid, but oxamic acid was removed much more slowly. Each acid underwent a similar decay in AO-BDD-Fe2+ and EFBDD, as expected if its iron complexes were not attacked by hydroxyl radicals in the bulk. The faster and total mineralization of both acids was achieved in AO-BDD-Fe2+-UVA due to the high photoactivity of their Fe(III) complexes that were continuously regenerated by oxidation of their Fe(II) complexes. Oxamic acid always released a larger proportion of NH4 + than NO3- ion, as well as volatile NOx species. Both acids were independently oxidized at the anode in AO-BDD, but in AO-BDD-Fe2+-UVA oxamic acid was more slowlydegraded as its content decreased, without significant effect on oxalic acid decay. The increase in current density enhanced the oxidation power of the latter method, with loss of efficiency. High Fe2+ contents inhibited the oxidation of Fe(II) complexes by the competitive oxidation of Fe2+ to Fe3+. Low current densities and Fe2+ contents are preferable to remove more efficiently these acids by the most potent AO-BDD-Fe2+-UVA method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advanced oxidation processes (AOPs) have been studied and developed to suffice the effective removal of refractory and toxic compounds in polluted water. The quality and cost of wastewater treatment need improvements, and electric discharge technology has a potential to make a significant difference compared to other established AOPs based on energy efficiency. The generation of active oxidant species such as ozone and hydroxyl radicals by high voltage discharge is a relatively new technology for water treatment. Gas-phase pulsed corona discharge (PCD), where a treated aqueous solution is dispersed between corona-producing electrodes free of the dielectric barriers, was developed as an alternative approach to the problem. The short living radicals and ozone formed in the gas phase and at the gas-liquid interface react with dissolved impurities. PCD equipment has a relatively simple configuration, and with the reactor in an enclosed compartment, it is insensitive towards gas humidity and does not need the gas transport. In this thesis, PCD was used to study and evaluate the energy efficiency for degrading various organic compounds, as well as the chemistry of the oxidation products formed. The experiments investigate the aqueous oxidation of phenol, humic substances, pharmaceutical compounds (paracetamol, ibuprofen, indomethacin, salicylic acids, -estradiol), as well as lignin degradation and transformation to aldehydes. The study aims to establish the influence of initial concentration of the target pollutant, the pulsed discharge parameters, gas phase composition and the pH on the oxidation kinetics and the efficiency. Analytical methods to measure the concentrations of the target compounds and their by-products include HPLC, spectrophotometry, TOC and capillary electrophoresis. The results of the research included in this summary are presented in the attached publications and manuscripts accepted for publication. Pulsed corona discharge proved to be highly effective in oxidizing each of the target compounds, surpassing the closest competitor, conventional ozonation. The increase in oxidation efficiencies for some compounds in oxygen media and at lower pulse repetition frequencies shows a significant role of ozone. The role of the ·OH radicals was established in the surface reactions. The main oxidation products, formation of nitrates, and the lignin transformation were quantified. A compound specific approach is suggested for optimization of the PCD parameters that have the most significant impact on the oxidation energy efficiency because of the different characteristics and responses of the target compound to the oxidants, as well as different admixtures that are present in the wastewater. Further studies in the method’s safety (nitration and nitrosation of organic compounds, nitrite and nitrate formation enhancement) are needed for promoting the method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pollution of water with pesticides has become a threat to the man, material and environment. The pesticides released to the environment reach the water bodies through run off. Industrial wastewater from pesticide manufacturing industries contains pesticides at higher concentration and hence a major source of water pollution. Pesticides create a lot of health and environmental hazards which include diseases like cancer, liver and kidney disorders, reproductive disorders, fatal death, birth defects etc. Conventional wastewater treatment plants based on biological treatment are not efficient to remove these compounds to the desired level. Most of the pesticides are phyto-toxic i.e., they kill the microorganism responsible for the degradation and are recalcitrant in nature. Advanced oxidation process (AOP) is a class of oxidation techniques where hydroxyl radicals are employed for oxidation of pollutants. AOPs have the ability to totally mineralise the organic pollutants to CO2 and water. Different methods are employed for the generation of hydroxyl radicals in AOP systems. Acetamiprid is a neonicotinoid insecticide widely used to control sucking type insects on crops such as leafy vegetables, citrus fruits, pome fruits, grapes, cotton, ornamental flowers. It is now recommended as a substitute for organophosphorous pesticides. Since its use is increasing, its presence is increasingly found in the environment. It has high water solubility and is not easily biodegradable. It has the potential to pollute surface and ground waters. Here, the use of AOPs for the removal of acetamiprid from wastewater has been investigated. Five methods were selected for the study based on literature survey and preliminary experiments conducted. Fenton process, UV treatment, UV/ H2O2 process, photo-Fenton and photocatalysis using TiO2 were selected for study. Undoped TiO2 and TiO2 doped with Cu and Fe were prepared by sol-gel method. Characterisation of the prepared catalysts was done by X-ray diffraction, scanning electron microscope, differential thermal analysis and thermogravimetric analysis. Influence of major operating parameters on the removal of acetamiprid has been investigated. All the experiments were designed using central compoiste design (CCD) of response surface methodology (RSM). Model equations were developed for Fenton, UV/ H2O2, photo-Fenton and photocatalysis for predicting acetamiprid removal and total organic carbon (TOC) removal for different operating conditions. Quality of the models were analysed by statistical methods. Experimental validations were also done to confirm the quality of the models. Optimum conditions obtained by experiment were verified with that obtained using response optimiser. Fenton Process is the simplest and oldest AOP where hydrogen peroxide and iron are employed for the generation of hydroxyl radicals. Influence of H2O2 and Fe2+ on the acetamiprid removal and TOC removal by Fenton process were investigated and it was found that removal increases with increase in H2O2 and Fe2+ concentration. At an initial concentration of 50 mg/L acetamiprid, 200 mg/L H2O2 and 20 mg/L Fe2+ at pH 3 was found to be optimum for acetamiprid removal. For UV treatment effect of pH was studied and it was found that pH has not much effect on the removal rate. Addition of H2O2 to UV process increased the removal rate because of the hydroxyl radical formation due to photolyis of H2O2. An H2O2 concentration of 110 mg/L at pH 6 was found to be optimum for acetamiprid removal. With photo-Fenton drastic reduction in the treatment time was observed with 10 times reduction in the amount of reagents required. H2O2 concentration of 20 mg/L and Fe2+ concentration of 2 mg/L was found to be optimum at pH 3. With TiO2 photocatalysis improvement in the removal rate was noticed compared to UV treatment. Effect of Cu and Fe doping on the photocatalytic activity under UV light was studied and it was observed that Cu doping enhanced the removal rate slightly while Fe doping has decreased the removal rate. Maximum acetamiprid removal was observed for an optimum catalyst loading of 1000 mg/L and Cu concentration of 1 wt%. It was noticed that mineralisation efficiency of the processes is low compared to acetamiprid removal efficiency. This may be due to the presence of stable intermediate compounds formed during degradation Kinetic studies were conducted for all the treatment processes and it was found that all processes follow pseudo-first order kinetics. Kinetic constants were found out from the experimental data for all the processes and half lives were calculated. The rate of reaction was in the order, photo- Fenton>UV/ H2O2>Fenton> TiO2 photocatalysis>UV. Operating cost was calculated for the processes and it was found that photo-Fenton removes the acetamiprid at lowest operating cost in lesser time. A kinetic model was developed for photo-Fenton process using the elementary reaction data and mass balance equations for the species involved in the process. Variation of acetamiprid concentration with time for different H2O2 and Fe2+ concentration at pH 3 can be found out using this model. The model was validated by comparing the simulated concentration profiles with that obtained from experiments. This study established the viability of the selected AOPs for the removal of acetamiprid from wastewater. Of the studied AOPs photo- Fenton gives the highest removal efficiency with lowest operating cost within shortest time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work studied the degradation of dipyrone, via electrochemical processes and via electro-Fenton reaction using a 4% CeO2/C gas diffusion electrode (GDE) prepared via modified polymeric precursor method. This material was used to electrochemically generate H2O2 through oxygen reduction. The mean crystallite sizes estimated by the Scherrer equation for 4% CeO2/C were 4 nm for CeO2-x (0 4 4) and 5 nm for CeO2 (1 1 1) while using transmission electron microscopy (TEM) the mean nanoparticle size was 5.4 nm. X-ray photoelectron spectroscopy (XPS) measurements revealed nearly equal concentrations of Ce(III) and Ce(IV) species on carbon, which contained high oxygenated acid species like CO and OCO. Electrochemical degradation using Vulcan XC 72R carbon showed that the dipyrone was not removed during the two hour electrolysis in all applied potentials by electro-degradation. Besides, when the Fenton process was employed the degradation was much similar when using cerium catalysts but the mineralization reaches just to 50% at -1.1 V. However, using the CeO2/C GDE, in 20 min all of the dipyrone was degraded with 26% mineralization at -1.3 V and when the Fenton process was employed, all of the dipyrone was removed after 5 min with 57% mineralization at -1.1 V. Relative to Vulcan XC72R, ceria acts as an oxygen buffer leading to an increase in the local oxygen concentration, facilitating H2O2 formation and consequently improving the dipyrone degradation © 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the application of an advanced oxidation process combining hydrogen peroxide with ultraviolet radiation (H2O2/UV) to remove recalcitrant compounds from Kraft bleaching effluent. Anaerobic pre-treatment was performed to remove easily degraded organics using a horizontal-flow anaerobic immobilized biomass (HAIB) reactor. Bleaching plant effluent was treated in the HAIB reactor processed over 19 h of hydraulic retention time (HRT), reaching the expected removal efficiencies for COD (61 +/- 3%), TOC (69 +/- 9%), BOD5 (90 +/- 5%) and AOX (55 +/- 14%). However, the anaerobic treatment did not achieve acceptable removal of UV254 compounds. Furthermore, there was an increase of lignin, measured as total phenols. The H2O2/UV post-treatment provided a wide range of removal efficiencies depending on the dosage of hydrogen peroxide and UV irradiation: COD ranged from 0 to 11%, UV254 from 16 to 35%, lignin from 0 to 29% and AOX from 23 to 54%. All peroxide dosages applied in this work promoted an increase in the BOD5/COD ratio of the wastewater. The experiments demonstrate the technical feasibility of using H2O2/UV for post-treatment of bleaching effluents submitted to anaerobic pre-treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecular modeling is growing as a research tool in Chemical Engineering studies, as can be seen by a simple research on the latest publications in the field. Molecular investigations retrieve information on properties often accessible only by expensive and time-consuming experimental techniques, such as those involved in the study of radical-based chain reactions. In this work, different quantum chemical techniques were used to study phenol oxidation by hydroxyl radicals in Advanced Oxidation Processes used for wastewater treatment. The results obtained by applying a DFT-based model showed good agreement with experimental values available, as well as qualitative insights into the mechanism of the overall reaction chain. Solvation models were also tried, but were found to be limited for this reaction system within the considered theoretical level without further parameterization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our aim was to investigate and determine the associations between oxidative stress (OS), dyslipidemia and inflammation in patients treated with continuous ambulatory peritoneal dialysis (CAPD) and hemodialysis (HD) using observational cross-sectional study. Twenty patients in CAPD and 48 in HD for at least 8 weeks and aged =18 years were included in the study. Individuals with malignant or acute inflammatory disease were excluded. A control group of 17 healthy individuals was also recruited. The biochemical parameter evaluations were analyzed using colorimetric kits for albumin, serum glucose, total cholesterol (TC) and lipid fractions. To determine the inflammatory status, CRP, IL-6 and TNF-a were analyzed by automated chemiluminescence kits. Plasma advanced oxidation protein products (AOPP) were determined by spectrophotometry. Mean AOPP levels were significantly higher for the HD group compared to the control, and there was no difference in AOPP concentrations between the control and CAPD groups. Dialysis patients had levels of inflammatory parameters higher than controls, and showed a high prevalence of patients with dyslipidemia, especially in CAPD. In the HD group, AOPP was positively correlated with triglycerides (TG) and inversely associated with HDL. Also the HD group was observed to have negative associations between TNF-a and HDL, LDL and TC. In the CAPD group, CRP was inversely correlated with HDL. Hemodialysis patients had increased protein OS and associations of inflammation and dyslipidemia were also observed in these dialysis groups. A more detailed characterization of the relations between oxidative stress and other more traditional risk factors has therapeutic importance, since cardiovascular diseases are the leading cause of death among dialysis patients.