992 resultados para adult hearing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The Any Qualified Provider framework in the National Health Service has changed the way adult audiology services are offered in England. Under the new rules, patients are being offered a choice in geographical location and audiology provider. This study aimed to explore how choices in treatment are presented and to identify what information patients need when they are seeking help with hearing loss. Design: This study adopted qualitative methods of ethnographic observations and focus group interviews to identify information needed prior to, and during, help-seeking. Observational data and focus group data were analysed using the constant comparison method of grounded theory. Study sample: Participants were recruited from a community Health and Social Care Trust in the west of England. This service incorporates both an Audiology and a Hearing Therapy service. Twenty seven participants were involved in focus groups or interviews. Results: Participants receive little information beyond the detail of hearing aids. Participants report little information that was not directly related to uptake of hearing aids. Conclusions: Participant preferences were not explored and limited information resulted in decisions that were clinician-led. The gaps in information reflect previous data on clinician communication and highlight the need for consistent information on a range of interventions to manage hearing loss.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present days it is critical to identify the factors that contribute to the quality of the audiologic care provided. The hearing aid fitting model proposed by the Brazilian Unified Health System (SUS) implies multidisciplinary care. This leads to some relevant and current questions. OBJECTIVE: To evaluate and compare the results of the hearing aid fitting model proposed by the SUS with a more compact and streamlined care. METHOD: We conducted a prospective longitudinal study with 174 participants randomly assigned to two groups: SUS Group and Streamline Group. For both groups we assessed key areas related to hearing aid fitting through the International Outcome Inventory for Hearing Aids (IOI-HA) questionnaire, in addition to evaluating the results of Speech Recognition Index (SRI) 3 and 9 months after fitting. RESULTS: Both groups had the same improvement related to the speech recognition after nine months of AASI use, and the IOI-HA didn't show any statically significant difference on three and nine months. CONCLUSION: The two strategies of care did not differ, from the clinical point of view, as regards the hearing aid fitting results obtained upon the evaluation of patients in the short and medium term, thus changes in the current model of care should be considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study investigated body position effects on transient evoked otoacoustic emission (TEOAE) recordings of clinical significance. Sixty adults (30 males, 30 females) were assessed using the Otodynamics ILO88 Analyzer in three positions (sitting, supine, and side-lying). Results indicated significant positional effects on the TEOAE parameters of A-B difference, noise, whole wave reproducibility, and response levels. These differences included higher noise levels in supine and side-lying positions in comparison to the upright sitting position. Lower whole wave reproducibility measurements, and higher response amplitudes, in the side-lying position compared with supine and seated positions were also observed. No significant effects were evident for signal-to-noise ratio or band reproducibility. Given the lack of significant body position effects on these latter parameters and the infrequent clinical use of the other parameters in isolation, there was no evidence to suggest the future need for major review of current pass/fail criteria or of the standard test protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Coping behaviour in adult hearing loss is still not well understood. Despite the high prevalence of hearing loss in those over 65, many people do not seek help for hearing loss. The common sense model of illness perceptions suggests that illness perceptions are a strong predictor of adapted coping behaviours, including help-seeking and take-up of treatments. This study aimed to determine the feasibility of using the brief illness perceptions questionnaire (bIPQ) to measure the impact of illness perception in predicting usage of NHS audiology services. Study design: Twenty-four volunteers were recruited from a standard NHS audiology outpatient clinic and illness perception was measured using the bIPQ. Two different recruitment strategies were explored and compared in terms of recruitment and retention rates. Comprehensibility of the questionnaire was assessed by Think Aloud Analysis in a subset of participants, while possible risks and burdens were monitored in structured telephone interviews. Results: The questionnaire is a comprehensive and quick tool to measure individual illness perception at minimal cost. We suggested minor adaptations of three questionnaire items to increase comprehension. Participants preferred to complete the questionnaire after their appointment at the clinic facilities rather than at home prior to their hearing assessment appointment. There were no identified risks or burdens to participants in this study. Conclusions: This approach met our criteria for feasibility. Understanding the impact of illness perception on patients’ coping behaviour in presbycusis could improve treatment outcomes and increase patient satisfaction, while promoting a more efficient and individualized audiology service.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the validity of the Wechsler-Bellevue Intelligence test for hearing impaired adolescents and adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Even though pediatric hearing aid (HA) users listen most often to female talkers, clinically-used speech tests primarily consist of adult male talkers' speech. Potential effects of age and/or gender of the talker on speech perception of pediatric HA users were examined using two speech tests, hVd-vowel identification and CNC word recognition, and using speech materials spoken by four talker types (adult males, adult females, 10-12 year old girls, and 5-7 year old girls). For the nine pediatric HA users tested, word scores for the male talker's speech were higher than those for the female talkers, indicating that talker type can affect word recognition scores and that clinical tests may over-estimate everyday speech communication abilities of pediatric HA users.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little is known about the way speech in noise is processed along the auditory pathway. The purpose of this study was to evaluate the relation between listening in noise using the R-Space system and the neurophysiologic response of the speech-evoked auditory brainstem when recorded in quiet and noise in adult participants with mild to moderate hearing loss and normal hearing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Hearing loss (HL) is defined as the complete or partial loss of hearing ability. Aims: To characterize (1) the degree of satisfaction among adult and elderly hearing aid (HA) users who were treated by a public hearing health service and (2) the relationship between satisfaction and the variables of gender, age, degree of HL, and type of HA. Method: The clinical and experimental study included the administration of the Satisfaction with Amplification in Daily Life (SADL) questionnaire to 110 patients who had used HAs for more than 3 months and were 18 years of age or older. Results: Test patients were sex-balanced (48% were women) and had a mean age of 67 years. A relatively high incidence of sensorineural moderate HL was detected in the study patients (66%) and device B was the most commonly used HA type (48%). No significant differences were evident between HA satisfaction and sex. The importance placed on services/costs and personal image varied between age groups. Correlation was evident at all levels between user satisfaction and amplification. Decreased satisfaction was observed in individuals with severe and/or profound HL. The type of HA used yielded statistically significant differences in the positive effects referring. Conclusion: No correlations were evident between the different factors proposed. HA users exhibited high levels of satisfaction in all SADL areas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.