11 resultados para acupoint


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presently, acupuncture is a technique considered to be capable of stimulating the regulatory systems of the organism, such as the central nervous system, the endocrine system and the immunological system. The median frequency of the upper trapezium muscle with 40% and 60% of maximal voluntary contraction (MVC) of 15 healthy volunteers, was analyzed after the individuals were submitted to the AA treatment. The non-parametric Friedman test was used to compare median frequency values. In this exploratory study, the level of significance of each comparison was set to p < 0.05. The intraclass analyses indicate a significant increase of the median frequency muscle at 60% of the MVC (Wicoxon test). Based on the results found, the AA peripheral stimulus can act as a modulator mechanism of muscle activity and was possible to verify correspondence of the auricular acupoint with the trapezius muscle. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years research explored different acupuncture stimulation techniques but interest has focused primarily on somatic acupuncture and on a limited number of acupoints. As regards ear Acupuncture (EA) there is still some criticism about the clinical specificity of auricular points/areas representing organs or structures of the body. The aim of this study was to verify through (Functional magnetic resonance imaging) fMRI the hypothesis of EA point specificity using two auricular points having different topographical locations and clinical significance. Six healthy volunteers underwent two experimental fMRI sessions: the first was dedicated to the stimulation of Thumb Auricular Acupoint (TAA) and the second to the stimulation of Brain Stem Auricular Acupoint (BSAA). The stimulation of the needle placed in the TAA of the left ear produced an increase in activation bilaterally in the parietal operculum, region of the secondary somatosensory area SII. Stimulation of the needle placed in the BSAA of the left ear showed a pattern that largely overlapped regions belonging to the pain matrix, as shown to be involved in previous somatic acupuncture studies but with local differences in the left amygdala, anterior cingulate cortex, and cerebellum. The differences in activation patterns between TAA and BSAA stimulation support the specificity of the two acupoints. Moreover, the peculiarity of the regions involved in BSAA stimulation compared to those involved in the pain matrix, is in accordance with the therapeutic indications of this acupoint that include head pain, dizziness and vertigo. Our results provide preliminary evidence on the specificity of two auricular acupoints; further research is warranted by means of fMRI both in healthy volunteers and in patients carrying neurological/psychiatric syndromes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the 20th century, the acupuncture has spread on occident as a complementary practice of heath care. This fact has motivated the international scientific community to invest in research that seek to understand why acupuncture works. In this work we compare statistically volt age fluctuation of bioelectric signals caught on the skin at an acupuncture point (IG 4) another nearby on acupuncture point. The acquisition of these signals was performed utilizing an electronic interface with a computer, which was based on an instrumentation amplifier designed with adequate specifications to this end. On the collected signals from a sample of 30 volunteers we have calculated major statistics and submitted them to pairing t-test with significance leveI a = O, 05. We have estimated to bioelectric signals the following parameters: standard deviation, asymmetry and curtose. Moreover, we have calculated the self-correlation function matched by on exponential curve we have observed that the signal decays more rapidly from a non-acupoint then from an acupoint. This fact is an indicative of the existence of information in the acupoint

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was conducted in order to verify the efficacy of lower doses and alternative routes of a prostaglandin F2 alpha analogue, luprostiol (PGF), for the induction of luteolysis and the precipitation of estrus in nonlactating Nelore cows (Bos taurus indicus). A conventional dose (15 mg) of PGF was compared to doses lower than the conventional dose, which ranges from 10 to 50%, that were administered intramuscularly (IM), intravulvosubmucosally (IVSM), or in the Bai-hui acupuncture site located within the lumbosacral area. The cows were administered PGF 8 day after estrus in the presence of a corpus luteum, and randomly assigned to the following groups: G1 (positive control), 15 mg, IM (n = 23); G2, 7.5 mg, IM (n = 23); G3, 3.75 mg, I M (n = 24); G4, 7.5 mg, IVSM (n = 25); G5, 3.75 mg, Bai-hui acupoint (n = 24); and G6, 1.5 mg, Bai-hui acupoint (n = 25). The results indicated that 50% of a conventional dose of PGF (7.5 mg) resulted in a complete luteal regression (plasma progesterone < 1 ng/ml) at Hour 48, and hastened estrus, regardless of whether or not PGF was administered IM or IVSM. Comparatively, 10 or 25% of the conventional dose, even when administered to the Bai-hui acupoint, resulted in an initial reduction in the concentration of progesterone at Hour 24, followed by an increase observed at Hour 48. In conclusion, 25% of a conventional PGF dose administered via the Bai-hui acupoint proved inadequate to induce a complete luteal regression, whereas 50% of a conventional dose administered IM or IVSM was found to be the minimal dose required to induce effectively a complete luteal regression, and to precipitate the onset of estrus in nonlactating Nelore cows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pharmacopuncture, the injection of subclinical doses of drugs into acupoints reduces drug undesirable side effects, residues in animal consumption products and treatment costs in large animals. Acepromazine (Acp) produces several undesirable effects, such as hypotension. Previous studies with the injection of 1/10 of Acp dose in dog acupoints showed its advantage for sedation, minimizing undesirable effects. Eight horses were randomly submitted to four different treatment protocols according to a Latin Square double-blind design: (i) 0.1 ml kg(1) of saline subcutaneously injected at the cervical region, (ii) 0.1 mg kg(1) of Acp injected subcutaneously at the cervical region, (iii) 0.01 ml kg(1) of saline injected into GV1 acupoint (aquapuncture) and (iv) 0.01 mg kg(1) of Acp injected into GV1 acupoint (pharmacopuncture). Heart rate, respiratory rate, head height and degree of sedation were measured before and at 30, 60 and 90 min after treatments. Signs of sedation were observed in all treated groups at 30 min and only in 1/10Acp-GV1 at 60 min after the treatments. Only the group treated with 0.1 mg kg(1) of Acp s.c. had significantly lower values of head height at 30 min. Respiratory rate tended to reduce in all groups but was significantly lower only in horses treated with 0.1 mg kg(1) of Acp s.c. Heart rate remained unchanged in all groups. Acp-pharmacopuncture on GV1 in horses produced a mild sedation when compared with the conventional dose of Acp. More investigations are necessary to determine the optimal dosage of Acp-pharmacopuncture for sedation in horses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Canine hip dysplasia (HD) is characterized by hip joint laxity and subluxation. It is the most common cause of osteoarthritis in dogs, especially in larger breeds. Its management includes nutritional supplements, nonsteroidal anti-inflammatory drugs, physical therapy, acupuncture or surgical procedures. Implantation of gold beads in acupuncture points and trigger points around a joint has been used in the treatment of osteoarthritis in dogs for at least 30 years. Gold bead implants(GBI) acts as continuous acupuncture stimulation and trigger point treatment in canine HD with long lasting results. Electrophysiological investigations of trigger points reveal dysfunctional muscle spindles which indicate that the electrical activity of active loci arises from extrafusal motor endplates.Case: This is a report on the use of acupuncture and GBI for bilateral HD in a nine year old female German Shepherd. The patient has a HD non-responsive to anti-inflammatory drugs and was unable to stand up or walk by its own. Radiographs showed marked dysplasia, significant subluxation with the femoral head partly out of a shallow acetabulum and massive secondary arthritic bone changes, mainly on the right side. The animal was submitted to eight acupuncture sessions with seven days interval. After the first acupuncture session the use of NSAID was interrupted. After eight weeks the dog was considered rehabilitated and underwent GBI in acupoints and trigger points as maintenance treatment. During the one-year follow-up period the improvement remained unchanged with no need of analgesics.Discussion: It has been suggested that acupuncture or GBI can treat the chronic pain resulting from osteoarthritis induced by HD. According to AP theory, GBI is permanent and long-lasting acupoint stimulation. Moreover, the method is inexpensive, quick and easy to perform, with no postoperative pain or need of exercise restriction. Although gold is extremely corrosion-resistant, the surface of the gold implants stimulates a reaction from the immune system causing an oxidative liberation of gold ions with anti-inflammatory actions. It is well known that gold ions are effective inhibitors of the respiratory burst of neutrophils and monocytes and the proliferation of lymphocytes. These findings suggest that gold implantation, on a local scale, mimics the anti-inflammatory and pain-relieving effect of drugs with chemically bound gold ions. The relatively slow speed of the process results in a limited liberation of gold ions securing that they are taken up almost exclusively by cells close to the implant. The nine year old female German shepherd had a positive response to acupuncture with pain relieve and locomotor rehabilitation. For the nine year old female German shepherd previous acupuncture sessions to GBI resulted in no post-implant worsening period. Indeed, the association acupuncture/GBI does not have the anti-inflammatory drugs undesirable effects and brings long lasting results. In conclusion, GBI therefore should be considered for canine HD when conservative or medical treatments fail to give the desired effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since all analgesics currently available for use in dogs have been associated with some adverse effects, the search for an effective analgesic that does not cause harm is important. This study investigated the postoperative analgesic effects of ozone administered either intrarectally or into acupoints in bitches undergoing ovariohysterectomy (OH). Twenty-four healthy adult bitches were randomly assigned to one of the three treatments 10min after sedation, as follows: 0.2mg/kg of intramuscular (IM) meloxicam (M); rectal insufflation of 10mL of 30μg/mL ozone (OI), or acupoint injection of 0.5mL ozone (30μg/mL; OA). Following sedation with acetylpromazine, anaesthesia was induced with propofol and fentanyl and maintained with isoflurane/O2. Pain was assessed using the modified Glasgow pain scale (MGPS) and the visual analogue scale (VAS) on the day before surgery, before anaesthesia, and at 1, 2, 4, 6, 8, 12 and 24h after surgery. Rescue analgesia was performed using 0.5mg/kg of morphine IM if MGPS was >3.33 points.No statistically significant differences in pain scales were found among the three analgesic protocols or the time points in each group ( P>. 0.05). Two dogs treated with OA required rescue analgesia. Meloxicam, rectal insufflation of ozone and ozone injected into acupoints provided satisfactory analgesia for 24. h in bitches undergoing elective OH. Ozone had no measurable adverse effects and is an alternative option to promote pain relief. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the sedative and clinical effects of the pharmacopuncture with xylazine, compared to the conventional dose of a intramuscular injection in dogs.METHODS: Twelve dogs were randomly distributed in two groups of six animals and treated as follows: control group (X-IM): 1mg kg(-1) of xylazine given intramuscularly (IM); pharmacopuncture group (X-Yintang): 0.1mg kg(-1) of xylazine diluted to 0.5 mL of saline injected into the Yin Tang acupoint. Heart rate, cardiac rhythm (ECG), systolic arterial blood pressure (SABP), respiratory rate (RR), rectal temperature (RT), blood glucose concentration, degree of sedation and adverse effects were evaluated.RESULTS: Sedative effect was observed in both groups. The degree of sedation was greater in X-IM only at 15 min when compared with X-Yintang group. Cardiovascular established was observed in X-Yintang group, while marked reduction in the HR and increased incidence of ECG abnormalities were detected in X-IM. In both treatment groups, minimal changes were observed in relation to SABP, RR, RT and blood glucose. High incidence (66%) of vomiting was observed in X-IM, while this adverse effect was absent in X-Yintang.CONCLUSION: Pharmacopuncture with xylazine induced clinically relevant sedative effects in dogs, with the advantage of reduction of undesirable side effects associated with alpha(2)-agonists, including bradycardia, cardiac arrhythmias, and emesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background This study compares the immediate effects of local and adjacent acupuncture on the tibialis anterior muscle and the amount of force generated or strength in Kilogram Force (KGF) evaluated by a surface electromyography. Methods The study consisted of a single blinded trial of 30 subjects assigned to two groups: local acupoint (ST36) and adjacent acupoint (SP9). Bipolar surface electrodes were placed on the tibialis anterior muscle, while a force transducer was attached to the foot of the subject and to the floor. An electromyograph (EMG) connected to a computer registered the KGF and root mean square (RMS) before and after acupuncture at maximum isometric contraction. The RMS values and surface electrodes were analyzed with Student's t-test. Results Thirty subjects were selected from a total of 56 volunteers according to specific inclusion and exclusion criteria and were assigned to one of the two groups for acupuncture. A significant decrease in the RMS values was observed in both ST36 (t = -3.80, P = 0,001) and SP9 (t = 6.24, P = 0.001) groups after acupuncture. There was a decrease in force in the ST36 group after acupuncture (t = -2.98, P = 0.006). The RMS values did not have a significant difference (t = 0.36, P = 0.71); however, there was a significant decrease in strength after acupuncture in the ST36 group compared to the SP9 group (t = 2.51, P = 0.01). No adverse events were found. Conclusion Acupuncture at the local acupoint ST36 or adjacent acupoints SP9 reduced the tibialis anterior electromyography muscle activity. However, acupuncture at SP9 did not decrease muscle strength while acupuncture at ST36 did.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The stimulation of acupoints along the meridians, but not the non-acupoints outside of the meridians, produces analgesia. Although the acupoint is defined at the body surface, the exact location of the acupoints is not known. This study aims to examine whether the intensity and duration of the analgesic effect of electroacupuncture (EA) at the Zusanli (ST36) and Sanynjiao acupoints (SP6) change according to the depth of the stimulation. Methods Ninety-six male Wistar rats classified as responders were arbitrarily allocated into 16 groups of six rats each. Six groups received EA with uninsulated acupuncture needles (type I) or needles that were immersed in varnish and had the varnish circularly peeled 0.2 mm from the tip (type II), 0.2 mm at 3 mm (type III) or 5 mm (type IV) from the tip, or 0.2 mm at 5 and 1 mm from the tip (type V), or EA sham for 20 min. Five groups received injection of formalin into the acupoint bilaterally at 5 mm or 1 mm deep into ST36, 5 mm below ST36 but inserting the needle at 45° to the skin surface, or 5 mm deep into non-acupoints. The remaining groups received intraplantar injection of saline, 1% or 2.5% formalin. The analgesic effects were measured by the rat tail-flick test. Results The bilateral stimulation of ST36 and SP6 by uninsulated or insulated needles produced analgesia in the rat tail-flick test. The stronger and longer lasting effects occurred after EA with the types I and V needles, or injection of formalin 5 mm deep into ST36. The remaining needles produced weaker and shorter lasting effects. Slow analgesic effect also occurred after formalin injection at 1 mm or 5 mm below ST36 by inserting the needle at 45° to the skin surface. Conclusion The experimental results suggest that the efficacy of the EA stimulation depends on the spatial distribution of the current density under the needling surface rather than only the acupoint or the depth of needling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

So far, most research attempts to explain the mechanism of the action of acupuncture have focused mostly on mechanically-triggered active factors and have produced inconclusive findings. In this study, we investigate whether acupuncture might also involve nonmechanical, nonpsychological active factors originating in the therapist. In 30 individuals, an acupuncture needle was inserted in the acupoint PC6 using a special device without touching the needle. A second device was used to fix the needle rigidly in place, excluding any mechanical transmission of movement from the handle to the needle's tip. Each participant was exposed in random order to a control and a stimulation phase. During the stimulation phase, the free needle's end was held by the therapist to allow the transmission of Qi; during the control phase, it was left untouched. Participants' subjective sensations during the stimulation phase and the control phase were recorded using a questionnaire. Twenty-two of 28 (79%; p = 0.003) test participants believed that they had received stimulation when it had actually been performed, and 26 (93%; p < 0.001) sensed differences between the two experimental phases. Thus, participants were able to sense the transmission of therapeutic Qi in the absence of mechanical or psychological factors.